Similar documents
UL YELLOW CARD FOR PLASTICS ADD MORE PROPERTIES, WIN NEW CUSTOMERS

Lexan* Resin 3412R Europe-Africa-Middle East: COMMERCIAL

Lexan* Resin 121 Europe-Africa-Middle East: COMMERCIAL

Supporting Product Innovation

HIGHTECH THERMOPLASTICS ENERGIZED BY

MN-3600H. Panlite. Technical note. Non-halogen PC high-resistant grade. (Comparison of MN-3600H with an company s heat resistant grade:a

D U R ETHAN AND POCAN F OR THE ELECTRI CAL IN D U STRY N EW HALOGE N-FRE E FLAME-RETARDANT

This is a preview - click here to buy the full publication ICS ISBN

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

EU flammability standards and ENFIRO

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The Appendix is an integral part of Certificate of Accreditation No. 104/2015 of

INTERNATIONAL STANDARD

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Certificate of Compliance

Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito. Matteo Paleari Senior Project Engineer

Drying your polymer. Why? Surface Moisture Hygroscopic: Hygroscopic: tending to absorb moisture from the air W I T H DRYING TECHNOLOGIES

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

UL 94 Flammability Ratings: Introduction

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

TOYOLAC PC//ABS Alloy PX10

INTERNATIONAL STANDARD

Fires, fire safety and trends.

Technical information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

SVENSK STANDARD SS-EN ISO

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Fire Test Methods ASTM NFPA UL ISO IEC

Performance of household electrical appliances-refrigerating. EN Domestic cooking appliances burning gas - Part 1-1: Safety - General

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Market-Leading Non-Metallic Enclosure Brands

PRINTED CIRCUIT BOARDS

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES

Fire Risks and Safety Standards

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

ANSI-ASQ National Accreditation Board/ACLASS

Submittal Packages Detailed with Items and Reviewers

Fiber Optic Distribution Cables (6-144 Fibers)

PLASTICS WORKSHOP ENGINEERED. Learn About Thermoplastics Connect with Experts WESTBOROUGH / MASSACHUSETTS (BOSTON AREA)

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Flame Retardant Polyethylene Tubing

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Product Information Motor and machine protection

Two Circuit Heavy Duty Burner Connector

Section Specification for Geotextile Used in Permanent Erosion Control Application

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Q1000 Series exit Devices

Jan05 Rev A EC

FIRE SAFETY OF ELECTRICAL AND ELECTRONIC EQUIPMENT ICL-IP SOLUTIONS

System Management Certifications. Testing processes Control quality laboratory ottobre 2018 P 2

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Automatic Waste Water Lifting Unit

Suppression of Class C Fires

2017 INDUSTRIAL FAN CATALOG

Flexible Heaters. of Silicone Rubber & Kapton

SECTION AIR DOORS

CERAMIC FIBER HEATERS

Pneumatic Tubing POLYTUBING O.D. 5/32"

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014

This document is a preview generated by EVS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Brasch Hazardous Location Unit Heaters

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Twin radial blower DRG 1200

The Laboratory is qualified to update standards identifying the test procedures.

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

Ceramic Fiber Heaters. Table Of Contents

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

INTERNATIONAL STANDARD

Twin radial blower DRG 730

SolderSleeve Insulated Electrical Termination Devices

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Twin-Agent Fire Fighting/Securing Systems Specifications

Type approval qualification of Photovoltaic Modules Procedures and test experiences

HOOK-UP AND LEAD WIRE. UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2. AWG Size. Number of Strands. Note: AWG 20 is available upon request.

PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS

Transcription:

UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E56070 CHI MEI CORPORATION 59-1 SAN CHIA, JEN TE, TAINAN HSIEN 717 TW PA-765A(+) Acrylonitrile Butadiene Styrene (ABS), "Polylac", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL 1.5 V-1 - - 85 80 85 2.1 V-0, 5VB 3 0 85 80 85 2.5 V-0, 5VA 3 0 85 80 85 3.0 V-0, 5VA 0 0 85 80 85 Comparative Tracking Index (CTI): 1 Dimensional Stability (%): - High-Voltage Arc Tracking Rate (HVTR): 2 High Volt, Low Current Arc Resis (D495): 7 Dielectric Strength (kv/mm): - Volume Resistivity (10 x ohm-cm) : - (+) - Optional prefix or suffix; may be used to denote usage of 0-0.5 percent acid scavengers. ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: 1983-06-23 Last Revised: 2007-11-29 Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC 60695-11-10, IEC 60695-11-20 Class (color) 1.5 V-1 (ALL) 2.1 V-0, 5VB (ALL) 2.5 V-0, 5VA (ALL) 3.0 V-0, 5VA (ALL) Glow-Wire Flammability (GWFI) IEC 60695-2-12 C - - Glow-Wire Ignition (GWIT) IEC 60695-2-13 C - - IEC Comparative Tracking Index IEC 60112 Volts (Max) - - IEC Ball Pressure IEC 60695-10-2 C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO 527-2 MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m 2 - - ISO Izod Impact ISO 180 kj/m 2 - - ISO Charpy Impact ISO 179-2 kj/m 2 - - Underwriters Laboratories Inc http://iq.ul.com/iq/newiq/list.aspx?ulid=565074 2010/6/9

UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E56070 CHI MEI CORPORATION 59-1 SAN CHIA, JEN TE, TAINAN HSIEN 717 TW PA-777D Acrylonitrile Butadiene Styrene/Phenyl Maleimide (ABS/PMI), "Polylac", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL 1.5-1.7 HB 4 0 50 50 50 Comparative Tracking Index (CTI): 1 Dimensional Stability (%): - High-Voltage Arc Tracking Rate (HVTR): 0 High Volt, Low Current Arc Resis (D495): 7 Dielectric Strength (kv/mm): - Volume Resistivity (10 x ohm-cm) : - ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 smallscale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: 1993-03-10 Last Revised: 2007-11-27 Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC 60695-11-10 Class (color) 1.5-1.7 HB75 (ALL) Glow-Wire Flammability (GWFI) IEC 60695-2-12 C - - Glow-Wire Ignition (GWIT) IEC 60695-2-13 C - - IEC Comparative Tracking Index IEC 60112 Volts (Max) - - IEC Ball Pressure IEC 60695-10-2 C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO 527-2 MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m 2 - - ISO Izod Impact ISO 180 kj/m 2 - - ISO Charpy Impact ISO 179-2 kj/m 2 - - Underwriters Laboratories Inc http://iq.ul.com/iq/newiq/list.aspx?ulid=245749 2010/4/9

UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E41938 E I DUPONT DE NEMOURS & CO INC ENGINEERING POLYMERS, CHESTNUT RUN PLAZA, PO BOX 80713, WILMINGTON DE 19880 70G33L(+) Polyamide 66 (PA66), glass reinforced, "Zytel", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL 0.71 HB 4 0 130 120 130 1.5 HB 4 0 130 120 130 3.0 HB 4 0 130 120 130 Comparative Tracking Index (CTI): 0 Dimensional Stability (%): 1.1 High-Voltage Arc Tracking Rate (HVTR): 1 High Volt, Low Current Arc Resis (D495): 5 Dielectric Strength (kv/mm): 23 Volume Resistivity (10 x ohm-cm) : 13 (+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics. NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "ZEN" for Zenite or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "THX" for Thermx or "ETPV" for ETPV grades. ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 smallscale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: 1996-08-06 Last Revised: 2005-01-10 Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC 60695-11-10 Class (color) 0.71 HB75 (ALL) 1.5 HB75 (ALL) 3.0 HB40 (ALL) Glow-Wire Flammability (GWFI) IEC 60695-2-12 C - - Glow-Wire Ignition (GWIT) IEC 60695-2-13 C - - IEC Comparative Tracking Index IEC 60112 Volts (Max) - - IEC Ball Pressure IEC 60695-10-2 C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO 527-2 MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m 2 - - ISO Izod Impact ISO 180 kj/m 2 - - ISO Charpy Impact ISO 179-2 kj/m 2 - - Underwriters Laboratories Inc http://iq.ul.com/iq/newiq/list.aspx?ulid=234410 2010/4/13