ARGO AR SERIES CONTROLS

Similar documents
AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

ARM SERIES Switching Relays With Priority

ARGO DPM-2 OUTDOOR TEMPERATURE SETBACK CONTROL

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road Dunkirk, NY ARH-1 ARH-2 ARH-3

ARGO ZONE VALVE CONTROLS AZ-4CP / AZ-6CP

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

USER'S INFORMATION MANUAL

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

L8151A Triple Aquastat Relay

USER'S INFORMATION MANUAL

R8888A,B Hydronic Circulator Zone Panels with Priority Control

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

USER'S INFORMATION MANUAL

Description / Applications

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Q7300L Series 2000 Commercial Thermostat Subbases

USER'S INFORMATION MANUAL

Q7300H Series 2000 Commercial Thermostat Subbases

L7224A,C; L7248A,C,L Oil and Electric Boiler Electronic Aquastat Controllers

Power Supply Display Module PSDM. Installation and Operation Manual

Erie WA300. Application. Features. Two Zone Hydro-Air Relay General Instructions

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

M6063A Compact Rotary Mixing Valve Actuator

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Description / Applications

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

Q7100A,C Thermostat Subbases

qualified heating installer/service technician

Installation, Operation & Service Manual

Q7100A,C,D Thermostat Subbases

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

Installation Guide for models:

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

MODEL Day Programmable 1 Heat / 1 Cool Electric / Gas

TAC Erie VL500. Application. Features. Zone Valve Control Center General Instructions

RA889A Switching Relay

Installation Instructions

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

RA889A Switching Relay

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

CAUTION: ELECTRICAL HAZARD

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Outdoor Reset IQ Option Card, p/n

USER'S INFORMATION MANUAL

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Q7800H Integrated Burner Control Subpanel

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Installation Requirements for Models:

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Outdoor Reset IQ Option Card, p/n

Indirect Fired Water Heater

USER'S INFORMATION MANUAL

Technical Specifications Installation & Maintenance Manual NOTICE

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Materials Housing plastic: Front display lights: Transformer voltage: Electrical switch rating, ZR/ZC, DHW, XX:

USER'S INFORMATION MANUAL

Installation Instructions

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation, Start-Up, and Operating Instructions

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

USER'S INFORMATION MANUAL

Model GPT 3 Freeze Protection Thermostat

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Transcription:

ARGO AR SERIES CONROLS AR822-II, AR861-2II, AR861-3II INSALLAION, OPERAION & MAINENANCE MANUAL AR861-2II AR822-II AR861-3II Information and specifications outlined in this manual in effect at the time of printing of this manual. ECR International, Inc. reserves the right to discontinue, change specifications or system design at any time without notice and without incurring any obligation, whatsoever. Manufactured by: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: www.ecrinternational.com www.argocontrols.com P/N 24005122 Rev. B [07/30/2016]

ABLE OF CONENS Safety Symbols...3 Introduction...3 Mounting Instructions...3 Electrical Specifications & Wiring...4 AR822-II Single Zone Relay AR822-II Control Features...4 AR822-II Sequence Of Operation...4 AR822-II Control Board...5 AR822-II Wiring Schematic...5 AR822-II Applications...6 AR822-II With Zone Valve...7 AR861-2II & AR 861-3II AR861-2II & AR 861-3II Control Features...8 AR861-2II & AR 861-3II Sequence of Operation...8 AR861-2II Control Board & Wiring Schematic...9 AR861-3II Control Board & Wiring Schematic...10 AR861-2II & AR 861-3II Applications... 11 AR861-2II & AR 861-3II Expansion Control... 15 AR Series With DPM-2 Outdoor Reset Control...16 Replacement Parts... 16 echnical Support... 16 DANIMPORAN: Read and understand the following instructions COMPLEELY before installing!! Keep this manual near boiler Retain for future reference 2 P/N 240005122, Rev. B [07/15/2016]

!!! WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious injury. Read this manual and understand all requirements before beginning installation. Become familiar with symbols identifying potential hazards. his is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death. DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Introduction his manual is intended to familiarize the installer and user of the Argo AR Series of controls with their installation and operation to assure normal trouble-free operation. Argo controls are designed and manufactured with quality components for maximum life and durability and require minimal service. o insure a satisfactory installation, it is imperative that the instructions be followed carefully before operating the control. Failure to do so may result in breach of warranty. Mounting Instructions Mount the Argo AR Series Control vertically on a solid wall or partition. For your convenience it is recommended that the control be mounted as close as possible to the device to be controlled. he control should never be mounted more than 75 feet away. Select a location that is easily accessible for installation and service. NOE: o reduce the possible transformer hum and relay noise that is sometimes amplified by mounting surfaces such as sheet metal, plasterboard, and similar materials, place rubber or felt washers between the case and the mounting surface.! CAUION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOICE Used to address practices not related to personal injury. 1. Position the control and mark the mounting holes. 2. Start screws (not provided) for the keyhole type mounting holes in the upper corner(s). ighten the screws down to about ⅛ (3mm) from the surface. he AR822-II will require a screw to be installed in the lower left hand corner after the control is hung and leveled. 3. Hang the control on the screw(s), position the case, and start the bottom screws. 4. ighten all screws. 3 P/N 240005122, Rev. B [07/15/2016]

Electrical Specifications & Wiring! General Wiring Notice WARNING Electrical shock hazard. Disconnect power before installing or servicing. Failure to follow these instructions could result in death or serious injury. All primary wiring must be 14 AWG minimum. orque terminal screws 6 to 7 inch pounds. U.S.A. - National Electric Code and any other national, state, or local code requirements. Wiring must be N.E.C. Class 1. CANADA - C.S.A. C22.1 Canadian Electrical Code Part 1 and any other national, provincial, or local code requirements. Wiring must be C.S.A. C22.1 C.E.C. Part 1. AR822-II Control Features Auto-Reset Electronic Fuse Protection Eliminates Nuisance Service Calls 15VA ransformer Robust Components Provide Years of rouble -Free Service Ice Cube echnology Plug-In Replacement Relays 5-Year Warranty AR822-II Sequence of Operation 1. When the thermostat connection to R/W calls for heat the circuit ON LED is illuminated. 2. he relay will then close. 3. he contacts between 3/4 NO and 5/6 NO will close. 4. he contacts between 3/4NC and 5/6NC will open. Part Number Model Number Electrical Specifications ransformer Voltage Relay Switching Action Contact/ Control Amp Draw (120VAC) Z140 AR822-II 120V/60Hz/40Va DPD 7.2 Z209 AR861-2II 120V/60Hz/75Va DPD 7.2 Z210 AR861-3II 120V/60Hz/75Va DPD 7.2 he following describes the function of each terminal. L1: Hot leg of 120VAC power input L2: Common leg of 120VAC power input 3: Input to one pole of relay contacts 4 NO: Normally open output, between 3 and 4 NO 4 NC: Normally closed output, between 3 and 4 NC 5: Input to one pole of relay contacts 6 NO: Normally open output, between 5 and 6NO 6 NC: Normally closed output, between 5 and 6NC /R and /W are thermostat connections. When hermostat calls completing the circuit the relay is activated. 4 P/N 240005122, Rev. B [07/15/2016]

AR822-II CONROL BOARD ARGO AR822- ELECRONIC FUSE R ORQUE ERMINAL SCREWS 6 O 7 INCH LBS W 24V NO C 5 6 NC 6 Class 2 erminals CIRCUI ON L2 4 4 Primary erminals 120 VAC NO NC Factory Installed Jumper Between L1 & 3 AR822-II WIRING SCHEMAICS 5 P/N 240005122, Rev. B [07/15/2016]

AR822-II APPLICAIONS AR822-II Single Zone Application with ankless Coil Boiler AR822-II Dual Zone Application without ankless Coiler Boiler O BURNER OR BURNER CONROL DO NO USE 6 P/N 240005122, Rev. B [07/15/2016]

AR822-II APPLICAIONS AR822-II Indirect ank with Zone Valve Control DOMESIC HO WAER AR822 ARGO R 24V W C NO NC 5 6 6 CIRCUI ON + L2 L1 120 VAC 3 4 4 NO NC JUMPER 120 VAC N L PRIORIY CIRC. SUPPLIED WIH AZ-5 SA SA SA SA SA 24 VAC COM X-X ON END SW 1 X1 X1 END SW 2 X2 X2 AZ-3 Zone Valve Controller ARGO AZ-5 ZONE 1 ZONE 2 ZONE 3 1 2 3 4 1 2 3 4 1 2 3 4 ZONE 4 ZONE 5 1 2 3 4 1 2 3 4 VALVE VALVE VALVE VALVE VALVE L 120 VAC N B1 1 B2 L8148 C1 2 C2 O BURNER OR BURNER CONROL DO NO USE HEAING ZONE PUMP L 120 VAC N NOE: hermostats must be mercury switch style or battery powered for this installation to function properly. 7 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II Control Features 2-Zone AR861-2II or 3-Zone AR861-3II Auto-Reset Electronic Fuse Protection Eliminates Nuisance Service Calls 15VA ransformer Robust Components Provide Years of rouble -Free Service Ice Cube echnology Plug-In Replacement Relays Function 5-Year Warranty AR861-2II & AR861-3II Sequence of Operation If the Switch is in the OFF Position: 1. When a zone calls for heat the corresponding zone LED is illuminated. 2. he relay for the corresponding zone will then close. 3. A/R terminals will close starting the boiler. 4. he corresponding GZ/HZ terminals will be energized with 120 Volts. If the Switch is in the ON Position: 1.Zone 1 becomes the priority zone. 2. When zone 1 calls for heat, the priority zone is activated and all other zones are deactivated (circulators for zones 2 and higher will not operate). Zone 1 LED is illuminated indicating a call for heat. 3. Zone 1 relay will close. 4. A/R terminals will close starting the boiler. 5. GZ 1/HZ 1 will be energized with 120 Volts. 8 P/N 240005122, Rev. B [07/15/2016]

AR861-2II CONROL BOARD & WIRING SCHEMAIC Class 2 erminals Primary erminals 9 P/N 240005122, Rev. B [07/15/2016]

AR861-3II CONROL BOARD & WIRING SCHEMAIC Class 2 erminals Primary erminals 10 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II APPLICAIONS he diagrams on the following pages represent the AR861-3II. he AR861-2II is wired in a similar fashion. erminals A and R Isolated End Switch Each of the low voltage controllers (SPS hermostats) will actuate a circulator and start the burner when used in conjunction with an isolated switch aquastat. Jumper: o be placed between terminals L and W. In this position A and R become the isolated end switch. (Jumper is factory installed in this position) AR861-3II 1 1 2 2 3 3 Class 2 Wiring Jumper L2 G 120 VAC L1 Hot G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 L4006A Milli Volt Gas Valve 11 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II APPLICAIONS AR861-3II 1 1 2 2 3 3 Class 2 Wiring Jumper G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 L2 G 120 VAC L1 Hot B1 1 B2 L8148 C1 2 C2 Do Not Use o Burner or Burner Control AR861-3II 1 1 2 2 3 3 Class 2 Wiring Jumper L2 G 120 VAC L1 Hot ransformer G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 24V L4006A Milli Volt Gas Valve 12 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II APPLICAIONS! WARNING AR relays will not work properly if 120 VAC polarity is not the same at 120 VAC L and N terminals on both AR control and boiler aquastat. he neutral and hot wires must not be reversed. Reversing the L and N wires could result in a secondary source of power that may activate the boiler under certain circumstances which could result in death or serious injury. erminals W and R to Aquastat ( W to ZC and R to ZR) Each of the low voltage controllers (SPS hermostats) will actuate a circulator and start the burner when used in conjunction with a boiler aquastat control. If the boiler temperature drops below the low limit (circulator) setting, all circulating will cease until the temperature of the boiler water is increased. Jumper: o be placed between terminals L and A. In this position a line voltage message is sent out R to ZR terminal on the aqustst and returns to W from the ZC terminal on the aqustst.! WARNING When using ZC-ZR attention must be paid to keep the polarity of the wiring consistent between the Argo control and boiler aquastat. Failure to do so could result in a secondary source of power activating the boiler under certain circumstances which could result in serious injury or death. Always disconnect power to both the Argo control and boiler when installing or servicing this product. 13 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II APPLICAIONS L8124 A or C Cad Cell Burner ZC ZR B1 AR861-3II 1 1 2 2 3 3 B2 Class 2 Wiring C1 C2 L1 L2 Jumper G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 L2 G 120 VAC L1 Hot L8124 A or C Burner ZC ZR B1 AR861-3II 1 1 2 2 3 3 B2 Class 2 Wiring C1 C2 L1 L2 Jumper G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 L2 G 120 VAC L1 Hot 14 P/N 240005122, Rev. B [07/15/2016]

AR861-2II & AR861-3II EXPANSION ECHNIQUE he two controls on this page are capable of running six zones. When they are installed as shown below, only one priority and four standard zones (for a total of five zones) are available. SA SA DOMESIC HO WAER ARGO RIPLE AR861-3 II PRIORIY 1 1 HERMOSAS 2 2 3 3 1.0 K 1.0 K 1.0 K 15VA PRIORIY ON PRIORIY OFF 2.7 K G W L A R GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 120VAC PRIORIY 120 V CIRCULAOR 2.7 K 2.7 K Important: Both left-hand 1 terminals must be connected together and both right-hand 1 terminals must be connected together. Reversing the wiring will result in the transformers being out of phase. N 120 VAC L JUMPER O BOILER - CIRC CIRC CIRC SA SA ARGO RIPLE AR861-3 II PRIORIY HERMOSAS 1 1 2 2 3 3 15VA PRIORIY ON PRIORIY OFF G W L A R 120VAC GZ1 HZ1 GZ2 HZ2 GZ3 HZ3 PRIORIY 120 V CIRCULAOR N 120 VAC L JUMPER O BOILER - DO NO USE CIRC CIRC 15 P/N 240005122, Rev. B [07/15/2016]

AR SERIES WIH DPM-2 OUDOOR RESE CONROL he DPM-2 Outdoor Reset Control is designed to raise or lower the temperature of the boiler supply water based upon a proportionate drop or rise in temperature at the outside sensor. his control plugs into Argo control equipment with a data port or as a stand alone device that can be easily wired into almost any system. See the separate DPM-2 Installation Manual for more information. Replacement Part Part Description Argo Part Number Replacement Control Relay R35C echnical Support For technical support on this and all Argo products, please contact ECR International echnical Service at 1-800-325-5479. Please have your model number available when calling. Model Number Installation Date Information Needed When Calling Installer ECR International 2201 Dwyer Avenue Utica, NY 13501 www.ecrinternational.com www.argocontrols.com P/N 240005122, Rev. B [07/15/2016]