HSI Fire and Safety Group, LLC 107 Garlisch Drive Elk Grove Village, IL 60007 www.homesafeguard.com expert@homesafeguard.com Revision: 1/1/2012 25S PreparedFor: HSIFire&SafetyGroup,LLC P: 1 (847) 427-8340 F: 1 (847) 427-8343 SECTION 1 PRODUCT AND COMPANY IDENTIFICATION Product number: 25S Company name: HSIFire&SafetyGroup,LLC Product name: SmokeCheck TM, SmokeDetectorTester, ModelNo.25S,2.5oz. Product class: AerosolProduct Manufacturer's name: ChicagoAerosol,LLC Address: 8407S.77thAvenueBridgeview,IL60455 Information phone: 1-800-424-9300 Domestic emergency phone: 1-800-424-9300 International emergency phone: 1-703-527-3887 SECTION 2 HAZARDOUS INGREDIENTS Ingredient % Occupational Exposure Limits Vapor Pressure TLV TWA mm Hg Hydrocarbon Blend 64.0psig@70ºF Propane, 45% 1000ppm 108psig@70ºF (CAS74-98-6) Butane, 55% 600ppm 17psig@70ºF (CAS106-97-8) **=Componentsmarkedwithadoubleasteriskarepresentabovethedeminimuscutofflevelandsubjecttothe reportingrequirementsofsection313oftitleiiiofthesuperfundamendmentsandreauthorizationactof1986and 40CFRPart372.N/A=Notavailable SECTION 3 PHYSICAL DATA Appearance: Clear,colorlessliquid Odor: SweetPetroleum Boiling Range (Aerosol): -25.1to+32ºF Evaporation Rate (Aerosol): Immediate@Tabove-25.1ºF Vapor Density (Aerosol): Heavierthanair % Volatile by Weight (Aerosol): <100% Weight per Gallon (Aerosol): 4.5#/Gal Page 1 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340
SECTION 4 FIRE AND EXPLOSION HAZARD DATA Flammability Rating (Aerosol): 140(Health=1,Flammability=4,Reactivity=0) ExtremelyFlammable(R12) Flashpoint (dispensed liquid): (TestMethod)138ºFTOC(TestMethod)445ºF(229ºC) ASTMMethodD93,Pensky-MartensClosedTester. Auto Ignition Temperature: 875ºF Extinguishing Media: Foam,CO2orDryChemical Unusual Fire and Explosion Hazards: Aerosolsmayburstifheatedtotemperaturesover 120ºF.Productisextremelyflammable. Fire Fighting Procedures: Keepaerosolscooledwithwaterandremovethemfromdangerassoonaspossible.Ifaerosolsarebursting, stayclear,untilburstingiscompleted.aerosolscanbeprojectileswhenbursting.thisproductistoxictofish. Donotallowrunoffintolakes,streams,tidalmarshes,orestuaries.Isolatefromoxidizers,heat,sparks,electric equipmentandopenflame. SECTION 5 HEALTH HAZARD DATA Effects of Overexposure Eyes: Maycausestinging,tearing,redness,swelling,blurredvisionandpossiblefreezeburns. Skin: Liquidcancauseseverefreezeburnssimilartofrostbite. Inhalation: Inhalationofvapormayproduceanestheticeffectsandfeelingeuphoria.Prolongedover-exposurecancause rapidbreathing,headache,dizziness,narcosis,unconsciousness,anddeathfromasphyxiation,dependingon concentrationandtimeofexposure.sustaineddeliberateinhalationoftheconcentratedproductmayleadto braindamageordeath. Ingestion: Aspirationhazard! Primary Routes of Entry: Inhalation. Emergency and First Aid Procedures Eyes: Flushwithplentyofwaterfor15minutes,getmedicalattention. Skin: Flushwithplentyofwaterfor15minutes.Ifanyirritationpersists,getmedicalattentionifthereisevidence oftissuedamage. Inhalation: HarmfulbyInhalation(R20).Removevictimtofreshairandprovideoxygenifbreathingisdifficult.Giveartificial respirationifvictimisnotbreathing.keeppersonwarmandquiet.getmedicalattention. Ingestion: DONOTinducevomiting!GetmedicalattentionIMMEDIATELY! Page 2 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340
SECTION 6 REACTIVITY DATA Stability: Stable Hazardous Polymerization: Willnotoccur Hazardous Decomposition Products: Thermaldecompositionmayyield:CarbonMonoxideorVolatileHydrocarbonVapors. Conditions to Avoid: Openflame,heat,sparks,electricalequipmentoranymeanswhichcancausehightemperaturesatorabove 120ºF. Materials to Avoid: Strongoxidizingagentsorreducingagents,strongacidsandbases. SECTION 7 SPILLS OR LEAKS PROCEDURES Steps to be taken Smallleakscanbemoppedorwipedimmediately.Removematerialstoout-of-doorsortoasourceofadequate ventilationandstorage.largeleaksshouldbehandledasfollows:evacuatearea.containliquid;transferto closedmetalcontainers.avoidopenflames,sparksandheatsources.keepoutofwatersupplies.donotapply directlytolakes,streams,tidalmarshes,orestuaries.donotapplywhenweatherconditionsfavordriftfrom areastreated.donotcontaminatewaterbycleaningofequipmentordisposalwastes. Waste Disposal Disposeinaccordancewithlocal,stateandfederalregulations. Do not puncture or incinerate containers. SECTION 8 SAFE HANDLING AND USE INFORMATION Respiratory Protection: Useonlywithadequateventilation.UseofprotectiveequipmentisnecessaryifPELandTLVlevelsare exceeded.inenclosedspacesuseanioshapprovedorganicvapor/mistcartridgerespiratororpositivepressureself-containedbreathingapparatus. Ventilation: Largeopenedareasorsufficientmechanical(Generaland/orLocalExhaust)ventilationtomaintainexposure belowpelandtlvlevels. Protective Equipment: Gloves,SafetyGlasses,respiratoryprotection,long-sleeveshirtdependingonlevelsandlengthofexposure. Hygienic Practices: Observenormalhygienicpractices.Washhandsafteruse.Washclothingbeforereuse. SECTION 9 SPECIAL PRECAUTIONS Handling and Storage: Productshouldbekeptattemperaturesbelow120ºFinadry,coolarea.Productisextremelyflammable.Keep awayfromheat,sparks,andflame.useonlywithadequateventilation.avoidbreathingofvaporormist.wear OSHAstandardgogglesorfaceshield.Weargloves,apronandfootwearimpervioustothismaterial. Keepoutofthereachofchildren(S2) Level3Aerosol Page 3 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340
SECTION 10 SHIPPING INFORMATION 1. DOT: Carton marked with: ShippingName: ConsumerCommodity HazardClass: ORM-D 2. IMDG (by water overseas) Proper Shipping Name: UN1950,Aerosols,2.1,Ltd.Qty Label: None 3. By Air (IATA) Proper Shipping Name: ID8000,ConsumerCommodity,9 Label: MiscellaneousDangerousGoods Packaging Instruction: 910 SECTION 11 TOXICOLOGICAL INFORMATION Acute Toxicity Whenusedasdirectedthisproductshouldposeessentiallynorisktousers.Donotspraydirectlyupontheskin oreyes,orfrostbitemayresultfromtherapidevaporationofthepropellant. Donotinhale.Useonlywithadequatenaturalorforcedairventilation. SeeSection8forothersafehandlingprecautions. Intheunlikelyeventofawarehouseorotherfire,leavetheareaimmediately.Combustionofthisproductwill producecarbondioxide,watervapor,tracesofcarbonmonoxide,andtracesofotherpyrogensandoxides. Smokeproductionshouldbeminimal. Chronic Toxicity Thecomponentsofthisproducthavenotbeenidentifiedasmutagens,carcinogensorthosecontributingto birthdefects. Repeatedexcessiveuseinnon-ventilatedareasmayresultinrespiratoryproblems. SECTION 12 ECOLOGICAL INFORMATION Ecological Dissipation Thegreatpreponderanceofthisproductisgaseous,underordinaryatmosphericconditions.Itwillrapidly dissipatevianaturalorartificialventilationsystems.thesegaseousingredientshavehalf-livesofabout5to12 daysinambientair,duringwhichtheyareconvertedtocarbondioxideandwatervapor. Environmental Compatibility Emissionsoftheverylargeproportionofhydrocarbonpropellantsarequicklybrokendownchemicallyintheair, forminginnocuouscompounds.the(proprietary)activeingredientisalsodecomposed,butmoreslowly,withthe formationofoxygencompounds.itisinsolubleinwater.it sactiononaquaticlifeforms,ifany,isunknown.this productcontainsnocfc s. SECTION 13 DISPOSAL CONSIDERATIONS Waste Disposal Donotpunctureorincinerateanyaerosolcontainer. Considercity,county,stateornationalregulations.TheU.S.EPAhasdeterminedthatcommerciallyemptied aerosolcansmayberecycled,wheresuchfacilitiesexist.mostgovernmentalentitiessupportthisposition. Alternatively,emptiedcansmaybeconsignedtoapprovedsanitarywasterlandfills. Aerosolsarenon-refillable U.S.DOT(Section193) Thisproducthasaverylongservicelife.Cansshouldnotbereplacedduetoage.Itisunsafetodispenselarge amountsofproduct,simplytoemptyacanfordisposal,unlessdoneintheopenairandbysprayingdownwindto preventexcessiveinhalation. Page 4 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340
SECTION 14 TRANSPORT INFORMATION General SeeSection10forbasicdetails. Designation of Product Aerosols,flammable. Shipinoutsidecartonsmarkedwith ORM-D,andweighingnotmorethan65poundseach.Noteas ConsumerCommodity. Shipperstobemarkedas LEVEL3,onanyoneverticalpanel. ProperShippingName:UN1950,Aerosols,2.1,Ltd.Qty. Ground Transportation USA Approvedforrail,truck,USPSandUPSwhenproperlymarked.anddocumented. Europe-ADR/RID Class2.1gases compressed,dissolvedorliquefiedunderpressure. Air Transportation USA&Europe ICAO/IATAClassification2.1 ProperShippingName:ID8000,ConsumerCommodity,9. Labelas:MiscellaneousDangerousGoods. PackagingInstruction910. Note:SomeairlineshaveAmericanPilotsAssociation(APA)requirements. International Maritime Transportation. MustcomplywithIMDGregulations.(Issue2000,Volume2,page93.ForUN-1950aerosols). SECTION 15 REGULATORY REQUIREMENTS Classification and Labeling USA ProductcomplieswithCPSC(ConsumerProductSafetyCommission)regulations. USA ProductcomplieswithOSHA(OccupationalHealthandSafetyAdministration)requirementsinthis MSDS,undertheirHazardCommunicationRule,29CFC1910.1200. EC LabelsforproductdistributedinEuropecomplywithECguidelines,ECDirectivesandnationallaws. Risk phases Danger(Signalword) Contentsunderpressure. ExtremelyFlammable withflameicon. Safety phrases Donotpunctureorincinerate. Donotusenearfire,heatorsparks. Donotpunctureorincineratecontainer,evenwhenempty. Storeattemperaturesbelow120ºF(48ºC.). Useandstoreonlyinwellventilatedareas Intentionalmisusebydeliberatelyconcentratingandinhalingcanbeharmfulorfatal. Keepoutofthereachofchildren Contentsofthiscontainercanigniteundercertaincircumstances. U.S. Superfund and Reauthorization Act (SARA) Title III (1986) NoneoftheingredientsinthisproductarerequiredtobereportedundertheComprehensiveEnvironmental Response,CompensationandLiabilityAct(CERCLA)reference40CFR117,302andtable40CFR117.3. orin the ExtremelyHazardousSubstances category,40cfr355. UnderMSDSRequirements(40-CFR-370) EPAHazards maybereportableas: Extremelyflammable. Acutehealthhazard irritant Immediatereleaseofpressure compressedgas. Under40-CFR372(ToxicChemicalReleaseReporting)theproductdoesnotcontainanychemicalinthe officiallisting. Proposition 65 (California) NoneoftheingredientsofthisproductareontheProposition65listoftoxicchemicals. Page 5 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340
Federal Water Pollution Control Act (40 CFR 401.15). Noneoftheingredientofthisproductareonthelistoftoxicwaterpollutants. Toxic Substances Control Act (TSCA) Alltheingredientsofthisproductareontheofficiallisting. Global Warming Substances Control Act; AB-32 (California) Noneoftheingredientsofthisproductarelistedasglobalwarmingagents. Federal Clean Air Act Amendments (1990) Thisproductcategoryisnotlistedasasourceofvolatileorganiccompounds,tobecontrolledviaState ImplementationPrograms(SIPs) Air Resources Board (ARB) of California Thisproductcategoryisnotcurrentlylistedasasourceofvolatileorganiccompounds. SECTION 16 MISCELLANEOUS INFORMATION National Fire Prevention Association (NFPA) Hazard Rating Fire (4) Health (1) Reactivity (1) Nuclear (1) National Fire Prevention Association (NFPA Code 30-B) Storage Fire Hazard Rating. LEVEL3 (Outsideshipperonly) Additional Safety Data 100%OzoneSafe.(Stratosphericozone) EnvironmentallySafe. Containsnotchlorinatedorganiccompounds. Containsnophosphatesorpreservatives. Containsnoheavymetalcompounds Anhydrousformulation. NOTE: Thisrevision,dated8/15/08,replacesthosedated3/07/08and7/20/07Itissubjecttochanges withoutnotice,asnewregulationsorinformationbecomesavailable. The information contained in this Material Safety Data Sheet (MSDS) is furnished without warranty of any kind, expressed or implied. Information in this Data Sheet has been assembled by the manufacturer based on its own studies and on the work of others, and is believed to be correct as of the date issued. However, no warranty of any kind is expressed or implied as to the accuracy, completeness, or adequacy of the information obtained herein. The Manufacturer shall not be liable, regardless of fault, to the vendee, the vendee s employees, or anyone for any direct, special or consequential damages arising out of or in connection with the accuracy, completeness, or adequacy of the information obtained herein. It is intended to assist in the normal safe usage of product. Page 6 of 6 HSI Fire & Safety Group, LLC 1 (847) 427-8340