VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

Similar documents
VM-15 SERIES MONITOR. Model VM-15U1 VELOCITY MONITOR INSTRUCTION MANUAL

VM-15 SERIES MONITOR INSTRUCTION MANUAL

VM-5 SERIES MONITOR MODEL VM-55 VIBRATION MONITOR INSTRUCTION MANUAL

DTM Distributed Transmitter-Monitor

MODEL MP-1S OVERSPEED UNIT

VM-5 SERIES MONITOR INSTRUCTION MANUAL

VM-5 SERIES MONITOR. MODEL VM-5P3 Phase Marker Unit INSTRUCTION MANUAL

Pioneer-R16 Gas Monitor Operator s Manual

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor

Temperature Controllers

3500/61E & 3500/67E Temperature Monitor

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

I/A Series 716C 1/16 DIN Temperature Controller

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

VM-704B & VM-704 Temperature Monitor Module Manual

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

4 & 8-POINT ANNUNCIATORS Instruction Manual

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Advanced Ultraviolet Burner Controller

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

DIGITAL METERS Large Display Temperature Meters Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Oxygen (O2) Single-Point Gas Detection System

INSTALLATION INSTRUCTIONS

02/11/2015

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Water Detection Controllers

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

02/11/2015

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Installation Manual Tracker 221

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Dryer Master DM510 Commissioning Guide

Pump-Down Controller MODEL 4052

vibration switch

Model 4880 Status Output Display Module Manual

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

IVA7008 LEVEL METER - FFT ANALYZER - Auto Range

AUR300C. Advanced Ultraviolet Burner Controller

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Table of Contents SECTION PAGE

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

PumpSaver ISS-105 IS Super Cell Installation Guide

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Instruction Manual Model L2 RF Switch

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Beacon 800 Gas Monitor Operator s Manual

AO Annunciator Module

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Model 144H. Product Data Sheet , Rev DB February Content

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Specification , July 2015

Tri-Stack Smart System

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Pump-Up Controller MODEL 4062

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

VAMP 120 & 121. Arc flash detection units. Product picture

Model 1062 Environment Monitor

Touchpoint Plus. A whole new control experience

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

PHOTOELECTRIC AMPLIFIER SERIES

I/O ZONE 560/583 AND OPERATION MANUAL

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

D A R A - 4. Data Aire Relay Auto-Changeover

ESSEX ENGINEERING CORPORATION

S304 and S305 Dust Emission Monitors. User Manual. Distributor

EasyTronic III MANUAL SERVICE

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Standard Specifications

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

MODEL WIND TRACKER

Analog Room Pressure Monitor RPC Series

VQCM4 Colour Quad Installation & Instruction Manual

Hygro/hygrothermal transducers (hygrometric)

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

203RE ph v 1.0 Instructions

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Instruction Manual WARNING

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

Digital Heater Element Burnout Detector K8AC-H

Ultrasonic Proximity Sensor

Transcription:

Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis Function Tropical spec. I/O terminal block for 1 Class I Division 2 CSA Custom setup Custom setup 1 VM-761B instrument rack (When /ALY is requested) 2 VM-762B instrument rack *1 In future Specification INPUT Input system : 2systems Input system Channel combination : A: Ch1, Ch2 B: Ch3, Ch4 Input impedance : Approx. 50kΩ INPUT TRANSDUCER Ch1 : VK-202A or FK-202F Ch2 : CV-86 or CV-88 Ch3 : VK-202A or FK-202F Ch4 : CV-86 or CV-88 Indicators : OK LED (Green) When channel is normal : ON, When alarming : Flashing Monitor output : Location : BNC (Front) and connector (Back) Ch1 or Ch3 : BUFF* 2 Ch2 or Ch4 : BUFF, SEIS, ABS can be selected.* 2 Output impedance : 100Ω Output current : Max 5mA Measurement value : Combination Measurement value Ch1, Ch3 Ch2, Ch4 1 REL *2 ABS *2 2 REL *2 SEIS *2 3 SEIS *2 ABS *2 *2 BUFF : Buffer signal Input signal from a transducer is output via buffer amplifier. REL : Relative vibration SEIS : Seismic vibration The signal is converted from velocity signal to displacement signal. (787mV/100µm) ABS : Absolute vibration The signal is subtracted SEIS (Seismic vibration) on Ch2 or Ch4 from the input signal on Ch1 or Ch3 (Relative vibration). (787mV/100µm) Recorder output : Voltage or current output proportional to measurement value. Measurement value of each channel can be assigned to any output channel of its own module. Number of output points Output range : 4 points : 1 to 5V, 4 to 20mA, 0 to 5V, 0 to 10V I/O conversion accuracy : ±3% of F.S. at 25 C * 3 ±5% of F.S. at 0 C to 65 C * 3 Max. load resistance : 600Ω (current mode) Output impedance : Approx. 500Ω (voltage mode) Insulation resistance : 10MΩ at 100VDC Burnout function : Downscale 0% Downscale 0mA / 0mV Transducer power supply Proximity transducer : -24VDC/25mA Max. Piezoelectric transducer : +24VDC/4mA (constant current) Alarm contact : Number of relay : 6points (logic changeable) Contact type : Dry contact (SPDT) Contact capacity : 250VAC/5A, 30VDC/5A Output to analysis software (When /ALY is requested) Dynamic data : Synchronous waveform, Asynchronous waveform Static data : Amplitude (0.5X, 1X, 2X, nx(n=0.01 to 8.00), Not-1X, S (p-p) max ) Phase (0.5X, 1X, 2X, nx(n=0.01 to 8.00)) *3 At calibrate frequency. Rotation speed Refer to the specification sheet of VM-773B infisys ANALYSIS VIEW. ALARM Alarm set point Alarm set accuracy : Vibration monitoring 2 points (DANGER, ALERT), from 0 to 100% of monitor range, field changeable : Vibration ±(0.2% of F.S.+1digit) or less at 25 C Alarm set repeatability : ±1digit or less at 25 C Alarm delay time : 0 to 99sec (0.1 sec step, field changeable) Alarm reset : AUTO-RESET or SELF-HOLD field changeable. Alarm contact mode : Normally de-energized / Normally energized Alarm bypass function : Block off alarm output (DANGER) VIBRATION (OVER ALL) MONITORING Recommend monitoring range : 100 to 1000µm Accuracy : ±2% of F.S. at 25 C * 4 ±3% of F.S. at 0 C to 65 C * 4 HPF : 10Hz to 100Hz (-3dB), field changeable. * 5 (4 pole) 9.5Hz to 100Hz (-3dB), field changeable. * 5 (10 pole) LPF : 200Hz to 1kHz (-3dB), field changeable. * 5 (4 pole) Note) *4 At calibrate frequency. *5 There is un-match combination. (See Vibration (Over All) Monitoring (Selection Table for Filter Set Value P.5.) Sequence function : Used to prevent alarm output that is caused by excessive vibration during machine startup. Block off the DANGER/ALERT alarm, or switch the alarm setup value to another number magnified by setup number. Sequence Setup : Block off 1 to 10 (0.1 step, field changeable)! WARNING In case the SEQ. magnification number is setup from 2 to 10, the alarm setup value magnified by setup number while the SEQ. circuit is in progress should stay at or lower than 110% of the maximum monitor range. If the number is more than 110% of the monitor range the alarm may not output. Suppression function : If the vibration value is less than the setup value, this function is forced to suppress the measured vibration value and recorder output. *6 Suppression Setup Value: 0 to 5% ( 0.1% step, field changeable) 100(%) DISPLAY 0 *6 0 5 Input 100(%) Input/Output characteristic ANALYSIS FUNCTION (When /ALY is requested) Amplitude accuracy : Overall 0.5X, 1X, 2X, nx(n=0.01 to 10.00), Not-1X : ±3% of F.S. at 25 C ±5% of F.S. at 0 C to 65 C (for machine speed less than 30000r/min) S (p-p) max : ±5% of F.S. at 25 C ±7% of F.S. at 0 C to 65 C Phase accuracy : 0.5X, 1X, 2X : ±3 deg. of of F.S. at 25 C ±6 deg. of F.S. at 0 C to 65 C

Page 2 of 5 Specification ENVIRONMENTAL CONDITION Operating temperature : 0 to +65 C Storage temperature : -30 to +85 C Relative humidity : 20 to 95%RH (non-condensing) Power Consumption Module : Less than 15W MATERIAL AND FINISH Face plate : ABS (Black) Sheet : Polyester tough top (Gray) Base plate : Alminium alloy (Silver) MASS Body : Max. 1.0kg (2.2lb) ACCESSORY SPECIFICATION CODE / IDENTIFIED BY TB Code /TB1 /TB2 Accessory Transducer input terminal block plug(15pin) FRONT-MC-1.5/15-STF-3.81 (PHOENIX CONTACT) Recorder output terminal block plug(6pin) FRONT-MC-1.5/6-STF-3.81 (PHOENIX CONTACT) Contact output terminal block plug(18pin) FRONT-MC-1.5/18-STF-3.81 (PHOENIX CONTACT) Contact output terminal block plug(18pin) FRONT-MC-1.5/18-STF-3.81 (PHOENIX CONTACT) Note) *7 D-sub plugs and hoods are not included in this code. Please make necessary arrangement separately, if required. *8 When individually ordering specify the parts code, it is require to arrange for a necessary amount. Quantity (Part Code) 2pieces * 8 (7072NAB) 2pieces * 8 (7072NAC) 1piece (7072NAA) 1piece (7072NAA) Default Value! WARNING Some functions may not be available with old version. For details, please refer to "infisys Family Improvement Information" (no. : 11205E). INPUT Monitor range Input transducer Input system Input impedance : Ch1 0 to 200µm pk-pk (REL) Ch2 0 to 200µm pk-pk (ABS) Ch3 0 to 200µm pk-pk (REL) Ch4 0 to 200µm pk-pk (ABS) : VK-202A (non-intrinsic safety) CV-86 (non-intrinsic safety) : 2systems : 50kΩ FILTERING Low cut-off frequency : 10Hz (4 pole) High cut-off frequency : 1kHz Recorder output Monitor output : 4 to 20mA (4mA at the burnout) : Ch1 BUFF Ch2 BUFF Ch3 BUFF Ch4 BUFF ALARM DANGER set point : 160µm ALERT set point : 120µm OK set point : Ch1 and Ch3-1.4V (Low), -18.8V (High) Ch2 and Ch4 2.1V (Low), 22.0V (High) Alarm delay time : 3sec (DANGER, ALERT) Alarm reset : AUTO-RESET CONTACT Contact (RELAY1) : DANGER-1 Contact (RELAY2) : ALERT-1 Contact (RELAY3) : OR logic (NOT-OK-1 / NOT-OK-2) Contact (RELAY4) : DANGER-3 Contact (RELAY5) : ALERT-3 Contact (RELAY6) : OR logic (NOT-OK-3 / NOT-OK-4) Contact Mode : Nomally de-energized OTHERS Sequnce set value : 1 Suppression set value : 0% First out : OFF Timed OK channel defeat : ON Burnout : Downscale 0% Alarm Contact Operation Monitor alarm relay mode Monitor power OFF Monitor power ON Normal state Alarm state NO contact (NORMALLY DE-ENERGIZED) OPEN OPEN CLOSE NO contact (NORMALLY ENERGIZED) OPEN CLOSE OPEN NC contact (NORMALLY DE-ENERGIZED) CLOSE CLOSE OPEN NC contact (NORMALLY ENERGIZED) CLOSE OPEN CLOSE

Page 3 of 5 / Terminal Block (Connector) Pin Assignment VM-761B Instrument Rack (Back) 1 Monitor Output Connector 2 Transducer Input Terminal Block 3 Recorder Output Terminal Block 4 Contact Output Terminal Block Back of Instrument Rack / Terminal Block (Connector) Pin Assignment Fitting Part Code 1 1 CH1 MON 6 CH3 MON 2 CH1 COM 7 CH3 COM 3 CH2 MON 8 CH4 MON 4 CH2 COM 9 CH4 COM 5 N/A 7072NAD 7072NAG 2 A B A1 CH1 SIG B1 CH4 SIG A2 CH1 COM B2 CH4 COM A3 N/A B3 N/A A4 CH1 POW B4 N/A A5 CH1 SHIELD B5 CH4 SHIELD A6 CH2 SIG B6 N/A A7 CH2 COM B7 N/A A8 N/A B8 N/A A9 N/A B9 N/A A10 CH2 SHIELD B10 N/A A11 CH3 SIG B11 N/A A12 CH3 COM B12 N/A A13 N/A B13 N/A A14 CH3 POW B14 N/A A15 CH3 SHIELD B15 N/A Note2) 7072NAB 3 C D C1 REC1 + D1 REC4 + C2 REC1 - D2 REC4 - C3 REC2 + D3 N/A C4 REC2 - D4 N/A C5 REC3 + D5 N/A C6 REC3 - D6 N/A Note2) 7072NAC 4 E E1 RL1 N.O. E10 RL4 N.O. E2 RL1 COM E11 RL4 COM E3 RL1 N.C. E12 RL4 N.C. E4 RL2 N.O. E13 RL5 N.O. E5 RL2 COM E14 RL5 COM E6 RL2 N.C. E15 RL5 N.C. E7 RL3 N.O. E16 RL6 N.O. E8 RL3 COM E17 RL6 COM E9 RL3 N.C. E18 RL6 N.C. 7072NAA Note1) For the accessory specification code /TB1, the fitting terminal block plugs 2 3 4 are included. For the accessory specification code /TB1, the D-sub plug and hood 1 are not included. If required, please make necessary arrangement separately referring to the part code above. Note2) When individually ordering specify the parts code, it is require to arrange for a necessary amount.

Page 4 of 5 / Terminal Block (Connector) Pin Assignment VM-762B Instrument Rack (Back) 1 Monitor Output Connector 2 Transducer Input Connector 3 Recorder Output Connector 4 Contact Output Terminal Block Back of Instrument Rack / Terminal Block (Connector) Pin Assignment Fitting Part Code 1 1 CH1 MON 6 CH3 MON 2 CH1 COM 7 CH3 COM 3 CH2 MON 8 CH4 MON 4 CH2 COM 9 CH4 COM 5 N/A 7072NAD 7072NAG 2 A A1 CH1 IN A20 CH4 IN A2 CH1 COM A21 CH4 COM A3 N/A A22 N/A A4 CH1 POW A23 N/A A5 CH1 SLD A24 CH4 SLD A6 CH2 IN A25 N/A A7 CH2 COM A26 N/A A8 N/A A27 N/A A9 N/A A28 N/A A10 CH2 SLD A29 N/A A11 CH3 IN A30 N/A A12 CH3 COM A31 N/A A13 N/A A32 N/A A14 CH3 POW A33 N/A A15 CH3 SLD A34 N/A A16 N/A A35 N/A A17 N/A A36 N/A A18 N/A A37 N/A A19 N/A 7072NAF 7072NAJ 3 C C1 REC1 + C9 REC4 + C2 REC1 - C10 REC4 - C3 REC2 + C11 N/A C4 REC2 - C12 N/A C5 REC3 + C13 N/A C6 REC3 - C14 N/A C7 N/A C15 N/A C8 N/A 7072NAE 7072NAH 4 E E1 RL1 N.O. E10 RL4 N.O. E2 RL1 COM E11 RL4 COM E3 RL1 N.C. E12 RL4 N.C. E4 RL2 N.O. E13 RL5 N.O. E5 RL2 COM E14 RL5 COM E6 RL2 N.C. E15 RL5 N.C. E7 RL3 N.O. E16 RL6 N.O. E8 RL3 COM E17 RL6 COM E9 RL3 N.C. E18 RL6 N.C. 7072NAA Note) For the accessory specification code /TB2, the fitting terminal block plug 4 is included. For the accessory specification code /TB2, the D-sub plugs and hoods 1 2 3 are not included. If required, please make necessary arrangement separately referring to the part code above.

Page 5 of 5 Vibration (Over All) Monitoring (Selection Table for Filter Set Value) ( :YES :NO) LPF HPF <4 pole> 10Hz 20Hz 25Hz 30Hz 40Hz 50Hz 60Hz 100Hz 200Hz 300Hz 400Hz 500Hz 600Hz 800Hz 1000Hz LPF HPF <10 pole> 9.5Hz 12Hz 14Hz 15Hz 40Hz 60Hz 100Hz 200Hz 300Hz 400Hz 500Hz 600Hz 800Hz 1000Hz OTHERS