G.M. Advanced Fencing & Security Technologies Ltd

Similar documents
Fiber Optic Cable Fence Disturbance Sensor

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Introducing the innovative ipids Indoor Outdoor Detection System MANUFACTURING SECURITY SOLUTIONS

Section PERIMETER SECURITY SYSTEMS

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

ACTIVE INFRARED BARRIER

FenceSecure. Perimeter Intrusion Detection System

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Secure the other corner. bracket using the remaining screw,

PIDS Sensor Installation & Maintenance. 15/03/13/Rev1/PIDS Sensor Installation & Maintenance 1

Intrusion. Outdoor protection perimeter

SMARTWALK DEMENTIA WANDERING SYSTEM

Fiber SenSys. Fiber Optic Perimeter Detection Systems. Substation Physical Security Best Practices Baltimore 2017

Home Intrusion Detection System

Microphonic Cable Fence Disturbance Sensor (multiplex version)

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

VIDEO VISITATION APPLICATION: FUNCTIONS AVAILABLE:

TOTAL PERIMETER SOLUTION

TW-8000 TAUT WIRE FENCE

INTREPID Perimeter Intrusion Detection System

Protecting Station Platform & Rail Perimeters. TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems

TRINITY DUO IP HARDWIRED AND WIRELESS ALL-IN- ONE

LiteFENCE Lite with SV Lite Sensor

Intelli-FLEX Perimeter Protection System-Relay Output Processor. product guide. (DC/DC relay version)

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

Perimeter Intrusion Detection System

TOTAL PERIMETER SOLUTION

PTE0705 Electric Fence Monitor

TriSecure. Complete Perimeter Security System

Taut Wire intrusion detection sensor (TWIDS)

Professional Perimeter Security Solutions

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

FiberSensor Fiber Optic Intrusion Detection System (IDS)

1.1 Ensure the room is in the ACCESS state. Workstation indicates zone is in ACCESS state.

WG Buried Cable Perimeter Detection System

5000 INSTALLATION GUIDE

Presented By. BEI Security

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

HDCVI PIR Camera User s Manual

Safety Function: Single-beam Area Access Control (AAC)

Carbon Monoxide Transmitter

WG Buried Fibre Cable Long Perimeter Detection System

Integrated Security Solutions

PERIMETER FIBRE OPTIC PERIMETER PROTECTION SNAKE

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

INSTALLATION INSTRUCTIONS

Masthead Repeater Installation Handbook

Anti-climbing perimeter security in plastic fiber. Chain-link fencing

USER MANUAL FOR OPERATING SYSTEM

How to use the BTRM in Remote Enclosures

CARD ACCESS CONTROL SYSTEM

IRONCLAD Product Information

600 Range Dialer Installation Manual. Version 1.0

Networked Access Control Panel. Installation Guide

Committed to security

STEALTHFLEX Perimeter Protection System

Manufacturer of perimeter protection systems. Perimeter first line of protection. Microwave Bistatic Detectors. Microwave Monostatic Detectors

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

Control System. Mk2 WiFi Version Installation and setup manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

USER MANUAL QSDL506W Wireless Alarm System

PIR-100B User Manual

Access Control. Total Perimeter Protection Solutions from one Source

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

LPI Lightning Warning System (LWS) MKIII

EASY-WAVE Trash & Linen Chute System Installation

Consultant Specification AGILE Wireless Fire Detection System

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

English. Italiano. Português. Françias. Español

DeLaval activity meter system Instruction Book

Installation Instructions for W2H Series Signals

Combi B Alarm box. Mounting instructions

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

CV-350 TCP/IP Access Control System. System Overview

A Beginners Guide to Inner Range Systems

LPI Lightning Warning System (LWS) MKIII

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

OWNERS INSTRUCTION MANUAL

ESD Product Information

VIBRA-series: VIBRA, VIBRA +

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

-Tag. BodyGuard. Driver Awareness System SAFETY SOLUTIONS. Installation Guide. BodyGuard Safety Solutions A division of Orbit Communications Pty Ltd

JVA Electric Security Fence System. perimeter intruder detection system

Product Specifications

Infinity 2020 Perimeter Security System Overview & Advantages

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

Engineering Specification

Transcription:

GM Advanced Fencing & Security Technologies Ltd V-ALERT Perimeter Security Intrusion Detection System INSTALLATION MANUAL V2 GM Advanced Fencing & Security Technologies Ltd 14 Taas St PO Box 2327 Industrial Area Kfar Saba 44425 Israel Tel: 972-9-7662965 Fax: 972-9-7662964 E-mail: info@gmsecuritycom Website: wwwgmsecuritycom

2 Table of Contents 1 INTRODUCTION 3 2 SYSTEM ADVANTAGES3 21 The Major Advantages of GM s V-Alert Intrusion Detection System are:3 3 SYSTEM DESCRIPTION3 31 V-Alert Sensors and Cable (Part No VAF3)3 32 Zone Processor Card (Part No VAPC) and Cabinet (Part NoVAC)4 4 TYPICAL SYSTEM CONFIGURATION4 41 DUAL COMM Communication System4 42 SecurCOMM Central Control System Software5 5 V-ALERT PRINCIPLE OF OPERATION 5 6 INSTALLATION 5 61 SITE PLANNING and SITE SURVEY TYPICAL QUESTIONS 5 62 ZONE CONFIGURATION 6 63 PLACE OF ATTACHMENT OF THE SENSOR LINE 7 64 V-ALERT SENSOR FOR 2 FENCE PANELS 7 65 ATTACHMENT OF THE SENSOR LINE9 66 LIGHTNING PROTECTION - IMPORTANT 10

3 V-Alert Perimeter Security System 1 INTRODUCTION 11 GM s latest technological development is the V-Alert Vibration Detection System This system detects intrusion attempts caused by cutting or climbing the fencing barrier, breaking through walls or movement or vibrations on any other barrier or object on which it is installed 22 This installation manual describes the V-Alert System, its technology and the recommended methods of installation of the system 2 SYSTEM ADVANTAGES 21 The Major Advantages of GM s V-Alert Intrusion Detection System are: 211 No moving parts parts will not wear out 212 Higher detection resolution detection to the level of each individual sensor 213 Easier installation procedure 214 The ability to suit a wide range of applications due to the systems technological capabilities 215 Each sensor is programmable using the V-AlertComm Setting Manager Application 3 SYSTEM DESCRIPTION 31 V-Alert Sensors and Cable (Part No VAF3) 311 The system consists of 2 pairs of twisted pair cable connecting V-Alert sensors spaced 3 m apart 312 One pair of twisted pair cable carries power to each sensor whilst the other pair of twisted pair cable carries data from each sensor to the zone processing card 313 The V-Alert sensor line is typically 150 m in length, consisting of 50 sensors 314 The V-Alert sensors are typically supplied with 4 meters of cable between each sensor to allow for flexibility in the position of installation on the existing fence 315 The V-Alert sensors are supplied in sensor lines consisting of 10 sensors with a connection box used to connect adjacent 10 sensor lines 316 V-Alert sensor spacing for wall applications may vary between 5 to 15 meters depending on the type of wall installation 317 The V-Alert sensors are connected to the existing fence on site approximately 120 170 cm above the ground level, depending on the nature and height of the existing fence barrier 318 The V-Alert technology enables the installation on almost any fencing barrier without having to upgrade the existing fencing barrier 319 Typical fencing barriers on which the V-Alert system can be installed include: Chain Link fencing, welded mesh fencing, other metal fabric fences, walls and window bars 3110 The unique V-Alert Technology enables the installation on Barbed Wire fencing wires as well as on Electric Security Fencing wires 3111 The system can also be installed on walls where it will detect any attempt at breaking through the wall 3112 The system will detect an alarm as a result of CUTTING or CLIMBING of the fence structure

4 3113 The V-Alert System is designed in such a way so that an intrusion attempt will be detected to an alarm detection resolution of 3 m or to the level of each individual sensor 32 Zone Processor Card (Part No VAPC) and Cabinet (Part NoVAC) 321 The V-Alert Zone Processing Card is installed in an outdoor cabinet containing the V-Alert Zone Processor Card next to or in close proximity to the perimeter fence 322 The V-Alert Zone Processing Card can be used to connect 2 V-Alert sensor cable lines, each line consisting of 50 sensors, or 150 m of sensor cable The cabinets are therefore typically installed every 300 meters 323 The outdoor cabinet will contain a power supply unit and 12V battery to ensure that the system continues to operate in the event of a power supply failure The size of the battery is to be determined depending on the amount of back-up time required 324 The V-Alert Zone Processor Card is designed to work with the DUAL COMM Communication Card (see explanation below) for the transmission of the alarm indications to the Central Control Panel/Receiver 325 Alternately the V-Alert Relay Card (Part No VAR) has 5 relays for every sensor line 4 Relays are used for groups of sensors and the remaining relay is used to provide a CUT in the sensor line This is explained in more detail in the Cabinet Manual 326 110/220 V Mains Electricity points must be provided for electricity supply to each outdoor cabinet If it is not possible to supply 110/220V power supply to the cabinets then other methods of electricity supply can be considered 327 The cabinets can be heated if the winter weather temperatures are very low 328 The parameters of each individual sensor are programmed using GM's V-AlertComm Setting Manager Application 329 The sensor parameters are programmed by connecting the software application to the USB port on the V-Alert Processing Card in order to set the parameters of the sensor lines connected to the Processing Card 3210 The V-AlertComm Setting Manager Application is provided free of charge to the installer 3211 The V-AlertComm Setting Manager Manual is supplied separate to the V-Alert Installation Manual 4 TYPICAL SYSTEM CONFIGURATION 41 DUAL COMM Communication System 411 The alarm indications from the V-Alert Sensor line will be integrated with GM s DUAL COMM Communication system 412 The DUAL COMM system operates as a wireless and/or hardwired communication system 413 The DUAL COMM communication system consists of a communication card that transmits via wireless or hardwired communication to the DUAL COMM Control Panel/Receiver 414 The DUAL COMM Communication Card will be installed inside the outdoor cabinets that hold the V-Alert zone-processing card 415 For customers not wishing to use the DUAL COMM System, it is possible to use the V- Alert Relay Card referred to above 416 The operation of the DUAL COMM Communication System is explained in-depth in a separate operation and instruction manual (See DUAL COMM Manual)

5 42 SecurCOMM Central Control System Software 411 The DUAL COMM Communication system supplied can be integrated with a computercontrolled system that will consist of GM s SecurCOMM Central Control System Software 412 This software will centralize all the alarm signals from the perimeter security fence (V-Alert System and other systems such as the Electric Security Fence), show the site in the form of a synoptic map, and maintain and store an events log of all the events occurring in the site 5 V-ALERT PRINCIPLE OF OPERATION 51 The V-Alert sensor consists of a small printed circuit board containing electronic components that is encased in an epoxy weatherproof housing Electronic components in the sensor detect movement on the fence and convert these movements into electronic signals 52 There are no moving parts in the sensor that are a common source of false alarms in other vibration detection systems The sensor PCB consists of solid state electronics 53 Each individual sensor processes data resulting from movements on the fence line and transmits this data to the Zone Processor Card 54 Each individual sensor has its own ID 55 The continuous data flow from individual sensors is processed by the sensor itself and in turn analysed by the Zone Processor Card 56 The Zone Processor Card continuously compares the data from each individual sensor in order to detect whether the movement on the fence line is an intrusion attempt or not 57 Advanced algorithm technology enables the system to detect a REAL intrusion attempt that is usually caused by climbing or cutting of the fence or fence wires 58 The system is monitoring changes in the data flow from each individual sensor resulting in an alarm detection resolution of 3m or an alarm detection resolution to each individual sensor 59 An example of the operation of the system in operation can be described as follows: Strong wind on the sensor line causes an entire group of sensors to move Each individual sensor will detect movement, and the electronic signals or data will flow from each individual sensor to the zone-processing card If all the data received by sensors in that group of sensors show similar changes, then no alarm will be activated The Zone Processor Card will only alarm when an individual sensor or number of sensors transmits data that is different to data received by the larger group of sensors at that given moment The system adapts to the constantly changing conditions on the fence 6 INSTALLATION 61 SITE PLANNING and SITE SURVEY TYPICAL QUESTIONS 611 Examine the type of fence or wall on which the sensor line is to be installed 612 Record the following: - Fence Height - Distance between fence posts - Type of fence chain link, welded mesh, metal bars, palisade, wires etc - General condition and description of the fence taking into account outriggers, barbed wires on the top of the fence, concertina coil on the top of the fence, any other elements installed on the fence fabric such as signs or loose elements installed on the fence - Photograph the fence if possible

6 613 Look for the optimal position to install the sensor line on the fence or wall 614 Look for the optimal installation position of the electronic cabinet taking into account the zone configuration, position of gates and security personnel and source of 220/110 volts or alternative energy source 615 Look for or identify the optimal position of central control room or place in which the alarm indications are to be received Typically each site will have a pre-designated control or guard room 616 Decide what type of communication is to be used wired or wireless communication 617 More detailed explanation of the site planning considerations can be provided by GM's technicians in the framework of project installation training or training seminars held on site, at the distributor or at GM's Israel offices 62 ZONE CONFIGURATION 621 It is essential to plan the zone configuration logically The objective is to make the reaction to the times of the security personnel quick and effective The security personnel should be able to react immediately to an alarm so has to be able to go directly to the place or position of the intrusion attempt 622 The diagram below shows a typical way of configuring the zones and numbering of the sensor line 623 The site should be divided up into zones each zone will consist of up to 50 sensors In the diagram below the site has been divided into Zones 1,2,3 and 4 624 Numbers 1,2,3 49,50 represent the number of sensors in each Zone 625 Typically one should assign the sensor number 1 at the start of the Zone 1,2,3 and 4 as seen in the diagram below 626 It should be decided to configure the zones either clockwise or anti-clockwise and to continue to use the same direction for that specific project or installation 627 The sensor number 1 to 50 should always be in the same direction for all the zones This enables the security personnel to go to the exact sensor or place of the intrusion attempt As an example, sensor number 35 will be in the same relative position within each of zones 1,2,3 and 4 Zone 3 1 2 3 48 49 50 CABINET B Zone 4 50,49,48 3,2,1 1,2,3 48,49,50 Zone 2 CABINET A 50 49 48 3 2 1 Zone 1

7 63 PLACE OF ATTACHMENT OF THE SENSOR LINE 631 It is essential that the sensor's are installed in the optimal position on the fence, wall or barrier, so as to ensure that the V-Alert System will operate at its maximum performance level The table below shows the typical and recommended places on the barrier where the sensors should be attached 632 Please take into account that although there are many types of standard fences such as chain link, welded mesh fencing etc, each fence or barrier should be examined independently in order to ensure that the sensor is installed in the optimal position on the fence or barrier If the installer is unsure of the optimal attachment position GM's technical support should be contacted Type of Fence Typical position of V-Alert Sensor marked by Welded Mesh Fence 25m Welded Mesh Fence with outrigger Chain Link Fence 25 m Wall Position and distance between sensors depends on the type of wall 64 V-ALERT SENSOR FOR 2 FENCE PANELS 641 It is possible to use one V-Alert Sensor for two fence panel One V-Alert Sensor will therefore detect attempts to cut the fence fabric or climb the fence from two adjacent fence panels 642 The use of this configuration should only be used by authorized installers who are familiar with the type of fence on which the V-Alert Sensor is to be installed 643 The ability to adjust the sensitivity and adjust the detection capability of the V-Alert Sensor makes the use of this option possible 644 In order to use this application a metal bracket must be installed that makes a mechanical connection between the adjacent fence panels as seen in the schematic diagram below

8 Schematic Diagram 641 Side View Schematic Diagram 641 Top View Fence Post Fence Fabric Metal Bracket V-Alert Sensor

9 65 ATTACHMENT OF THE SENSOR LINE 651 After having decided where to install the sensor line, the following procedure should be undertaken: a Bring the sensor line (consisting of ten sensors or 30 meters of sensor line) to the fence or barrier b Place the sensor line on the ground near the fence c Attach the sensors to the fence using the back plate and screws supplied with the sensor line PLEASE SEE THE PHOTOGRAPH BELOW SHOWING THE METHOD OF ATTACHMENT OF THE SENSOR d Attach the sensor cable to the fence fabric using cable ties The cable ties should be used to attach the sensor cable every 20-25 cm Do not over tighten the fence ties The cable should have enough slack so that it is not stressed, but tight enough so that it will not move in the wind e As the sensor line is typically supplied with 4 meters of cable between sensors there are many cases in which there will be extra cable remaining after attaching the sensors in their final position In this case the extra cable should be rolled up and connected securely to the fence fabric f Connect every group of ten sensors to the next group of 10 sensors using the cable connection box supplied with each 10 sensor line Attaching sensor lines to each other is a simple matter of connecting LIKE wires to each other:

10 Sensors 1-10 (First 10 sensors) GND +12 A B BLACK RED WHITE BLUE Sensors 11-20 (Second 10 sensors) GND +12 A B BLACK RED WHITE BLUE Next 10 sensors g The system will be supplied with an end of line resistor installed in a termination connection box The last sensor in any sensor line is to be attached to this termination box 2 termination boxes will be supplied for every zone processor card supplied h After attaching the entire sensor line to the fence connect the sensor cable line wires (COLOUR CODE: BLACK GND RED-WHITE- BLUE to the zone-processing card as follows: GND +12 A B BLACK RED WHITE BLUE i Having completed the attachment of the V-Alert sensor line to the fence, the installer can proceed to program the V-Alert Sensors using the V-Alert Set-up Application 66 LIGHTNING PROTECTION - IMPORTANT 661 The V-Alert Sensor and V-Alert 2 Zone Processor Card have lightning protection components on the respective PCB's 662 IT IS ESSENTIAL THAT EACH ELECTRONIC CABINET INSTALLED ON SITE BE FITTED WITH PROPER GROUNDING PROTECTION INSTALLED BY AN AUTHORIZED ELECTRICIAN THE GROUNDING REQUIREMENT WILL DIFFER ACCORDING TO THE CONDITIONS ON SITE GM WILL NOT TAKE ANY RESPONSIBILITY FOR DAMAGE TO THE V-ALERT ELECTRONIC SYSTEMS CAUSED BY DIRECT LIGHTNING STRIKES ON CABINETS THAT HAVE NOT BEEN CORRECTLY GROUNDED PLEASE NOTE: The objective of this manual is to provide initial installation guidelines in the mechanical installation of the V-Alert Intrusion Detection System GM recommend on site training, training in the Israel or training in the distributors offices in order to receive complete training in the use of the V-Alert System