USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

Similar documents
Is your current safety system compliant to today's safety standard?

IEC PRODUCT APPROVALS VEERING OFF COURSE

New requirements for IEC best practice compliance

InstrumentationTools.com

INTERNATIONAL STANDARD

Functional Safety: the Next Edition of IEC 61511

BRIDGING THE SAFE AUTOMATION GAP PART 1

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Failure Modes, Effects and Diagnostic Analysis

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

PPA Michaël GROSSI - FSCE PR electronics

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Safety Instrumented Systems The Smart Approach

This document is a preview generated by EVS

INTERNATIONAL STANDARD

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

Fire and Gas Detection and Mitigation Systems

INTERNATIONAL STANDARD

IEC61511 Standard Overview

Options for Developing a Compliant PLC-based BMS

New Developments in the IEC61511 Edition 2

Why AC800M High Integrity is used in Burner Management System Applications?

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Safety Transmitter / Logic Solver Hybrids. Standards Certification Education & Training Publishing Conferences & Exhibits

Safety Instrumented Systems

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

INTERNATIONAL STANDARD

Digital EPIC 2 Safety manual

100 & 120 Series Pressure and Temperature Switches Safety Manual

Certification Report of the ST3000 Pressure Transmitter

Session Ten Achieving Compliance in Hardware Fault Tolerance

INTERNATIONAL STANDARD

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

The SIL Concept in the process industry International standards IEC 61508/ 61511

INTERNATIONAL STANDARD

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Failure Modes, Effects and Diagnostic Analysis

Integrated but separate

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. February Valves

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

Functional Safety: What It Is, Why It s Important And How to Comply

Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT. Presented by : Arunkumar A

Failure Modes, Effects and Diagnostic Analysis

INTERNATIONAL STANDARD

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

Safety lnstrumentation Simplified

United Electric Controls One Series Safety Transmitter Safety Manual

ADIPEC 2013 Technical Conference Manuscript

Functional Safety Manual June pointek CLS500/LC500

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK


Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511

Failure Modes, Effects and Diagnostic Analysis

Numerical Standards Listing

Numerical Standards Listing

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

High Integrity Pressure Protection System

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

Failure Modes, Effects and Diagnostic Analysis

Karl Watson, ABB Consulting Houston LOPA. A Storage Tank Case Study. ABB Inc. September 20, 2011 Slide 1

Failure Modes, Effects and Diagnostic Analysis

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

TECHNICAL SPECIFICATION

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

The evolution of level switches and detectors

Effective Alarm Management for Dynamic and Vessel Control Systems

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure!

ISO INTERNATIONAL STANDARD

Failure Modes, Effects and Diagnostic Analysis

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

Soliphant M with electronic insert FEM52

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Achieve Success with European Medical Device Commercialization. By Russ King

Alarm Management Services

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Failure Modes, Effects and Diagnostic Analysis

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Managing the Lifecycle of Independent Protection Layers

2012 Honeywell Pacific Users Group. Sus tain.ability.

SECTION Fluorescent Dissolved Oxygen Measuring System

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

Securing and Protecting Process Plants in the Digital Age Functional safety requires IT security

2015 Honeywell Users Group Europe, Middle East and Africa

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

TECHNICAL REPORT IEC TR 62987

ISO INTERNATIONAL STANDARD

Process Safety Workshop. Avoiding Major Accident Hazards the Key to Profitable Operations

TECHNICAL SPECIFICATION

Transcription:

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES Angela E. Summers, Ph.D., P.E, President Susan Wiley, Senior Consultant SIS-TECH Solutions, LP Process Plant Safety Symposium, 2006 Spring National Meeting, Orlando, Florida, April 26-27, 2006. Meet SIS User Approval Mandates, Chemical Processing, May 2006. Abstract User approval is a simple process that supports design, engineering, configuration management, and management of change. User approval assesses manufacturer information and installed performance data to justify that a device is suitable for use in a safety instrumented system (SIS) application. The process supports configuration management and management of change activities by providing a means to determine whether a new or revised device is acceptable. This paper explains the concept of user approval as documented in ANSI/ISA 84.00.01-2004, ANSI/ISA TR84.00.04, and the Center for Chemical Process Safety book, Guidelines for Safe and Reliable Instrumented Protective Systems. Introduction This paper is distributed as is. All warranties, either expressed or implied, are disclaimed as to quality, performance, or merchantability, whether expressed, implied or statutory, hidden defects, or fitness for any particular purpose. The author makes no representations about the suitability of the information in this paper for any purpose. Reader bears the entire risk relating to the use of this paper. A paragraph similar to the above is contained in many end-user license agreements accepted during the installation of user software and in the hardware manufacturer s terms and conditions. The underlying concept is that the user of the product bears the risk associated with determining whether a product is fit for a particular purpose. The manufacturer limits its liability associated with effects beyond its control, such as the operating environment. Other limitations are generally addressed in the installation and maintenance manual (or in the safety manual for safety instrumented system devices). Product manuals provide warnings concerning the installation, commissioning, maintenance, and testing requirements. These agreements, terms, and warnings establish the boundary for the manufacturer s claims. Deviation from the manufacturer s recommended practices generally invalidates all warranties, either expressed or implied. No manufacturer s claim, third-party analysis, or certification report reduces the user s responsibility for determining the product is fit for purpose. This user responsibility was acknowledged in 12621 Featherwood Drive Suite 120 Houston, Texas 77034 Tel: (281) 922-8324 Fax: (281) 922-4362 www.sis-tech.com

August 22, 2008 Page 2 of 8 ISA 84.01-1996, which used the term user approved as hardware, software, procedures, etc., that the user has evaluated and determined to be acceptable for the application. The User Approval Process A user approval process should be established to examine evidence of the suitability of devices for the application and operating environment. A device can be user approved and considered suitable for use when it can be demonstrated that the device meets the core attributes associated with its protection layer. The device boundary includes the hardware and software elements necessary for the device to perform its design intent. The user approval process examines the device using analysis and testing and demonstrated performance in the operating environment. The outputs of the process should be an approved manufacturer s list and an installation, commissioning, and maintenance plan (e.g., the safety manual for the SIS) that outlines how the approved devices should be implemented. User approval requires a close relationship between the manufacturer and the owner/operator as a product moves from early development through obsolescence. Technology evolution results in some devices moving rapidly toward obsolescence. For example, the lifespan of some programmable devices is less than 10 years due to the rapid development of computer technology, the increasing demand for interconnectivity, and a desire for uniform configuration tools. Such rapid evolution results in the manufacturer selling products that have some of the desired hardware and software features with a migration path for future upgrades. In some cases, significant changes in the product may be required to correct problems or to provide requested functionality. The owner/operator should have a process to control the replacement of components in any way other than like for like. When the manufacturer offers a new version of an approved component or recommends a replacement, these new components should go through the user approval process. For new versions of approved products, this process can be simplified when the manufacturer provides documentation explaining changes to the products and highlights any configuration changes. Configuration management can be challenging, but is essential to achieve the core attributes. Success requires that SIS product specialists serve as an information resource for the owner/operator. These SIS specialists should be highly familiar with SIS requirements, receive and review advisory notices and product information from the manufacturer, and make decisions regarding the addition or removal of devices from the approved manufacturer s list. It is recommended that the SIS product specialist be independent of the project team seeking approval of the device. Field performance and lessons learned in applying a device should be shared with the manufacturer to assist in future product development and in the dissemination of information regarding critical failures. Monitoring field performance and sharing failure reports with project and plant personnel is important for performance improvement. 12621 Featherwood Drive, Suite 120 Houston, Texas 77034

Operating Environment The operating environment can be identified by drawing an imaginary bubble around the device as installed in the process. The bubble establishes the boundary of the device. The operating environment may include a variety of items that affect device operation: External environmental conditions, Process operational conditions, Communications and interconnectivity, Human interfaces, Access security, Support systems, e.g. instrument air and electricity. For Programmable Electronic (PE) logic solvers, the operating environment also covers the embedded software, the hardware architecture, application software, I/O configuration, communication to other systems, operator and engineering interfaces, and access security. Analysis and Testing Devices should be subjected to analysis and testing to evaluate the device s design, manufacture, and validation procedures, as well as the manufacturer s quality and change management systems. The rigor of the analysis and testing is related to the complexity of the device and the maturity of its technology. When completed, there should be a better understanding of how the device functions and fails. This analysis should consider the device boundary and should result in the following: Description of the analysis boundary. Identification of potential dangerous failures. Identification of means to detect dangerous failures by diagnostics or testing. Description of assumed diagnostic coverage factor and any user requirements necessary to achieve the diagnostic coverage, e.g., configuration requirements and the need for external diagnostics. Statement of the probability of safe and dangerous failures with any assumptions regarding maintenance activities and testing intervals. Analysis and testing should also include evaluation of the device s conformance to applicable codes, standards, and practices. Meeting the area classification (e.g., hazardous environments) and following applicable electrical codes is important for all instrumented system applications. Devices that do not meet the area classification can become ignition sources should a loss of containment occur. For SIS, the requirements of IEC 61511 Clause 11.5 should be met. Guidance on complying with this clause is also provided in ANSI/ISA TR84.00.04 Annex L. Manufacturers, who wish to advertise their products as safety products, analyze and test their devices for compliance with the intent of IEC 61508. An IEC 61508 evaluation may yield a certification if 12621 Featherwood Drive Suite 120 Houston, Texas 77034 Tel: (281) 922-8324 Fax: (281) 922-4362 www.sis-tech.com

August 22, 2008 Page 4 of 8 the product is evaluated by a recognized certification body. A certified device can be labeled with an SIL (Safety Integrity Level) Claim Limit. In the United States, certification to IEC 61508 is issued by Nationally Recognized Testing Laboratories (NRTL), such as those listed on the US-OSHA website (www.osha.gov). The OSHA website has a complete listing of NRTLs. Other countries establish certification requirements by policy or regulation acceptable certification bodies. When a device is certified according to IEC 61508, the manufacturer supplies a safety manual providing the criteria for its implementation. Successful implementation of SIS devices often requires a specific configuration, the addition of external diagnostics, the provision for inspection and maintenance, mandated proof test intervals, and specific installation details. Deviation from the safety manual may invalidate the SIL Claim Limit. It is important to note that IEC 61508 is a generic functional safety standard that applies to safetyrelated systems used in many different industry sectors, including process, rail, machinery, and medical. Since this standard applies to many sectors, there are devices that meet the requirements of IEC 61508, but are not sufficiently robust for the operating environment in many process industry facilities. A device developed for use on a manufacturing floor may not be appropriate for use in a refinery SIS. Manufacturers sometimes provide field performance reports based on an installed base at other owner/operator sites. More often, manufacturers supply analysis and testing results and documented predictive calculations of their product s probability to fail on demand and spurious trip rate based on the product s shelf-state design and manufacture. For any new technology, the analysis and testing is generally based on very limited field operating experience. Thus, the manufacturer evaluation represents the highest performance that can be expected from the device when it is implemented in accordance with its safety manual. Field device and non-pe logic solver performance is generally dictated by the operating environment and the owner/operator s inspection and maintenance practices. For example, a sampling of data for pressure transmitters from various manufacturers show 600 to 800 year mean time to failure dangerous (MTTFD), however, owner/operator prior use data show a range of 75 to 200 year MTTFD. Many important failure modes are excluded from the manufacturer s boundary. This includes the process connections, manner of installation, power supplies, and communication interfaces. Failures due to the operating environment can be significantly greater than failures due to device manufacture. Failures in the interfaces between the device, the process, and other protective systems should be considered when determining its suitability for addition to the approved manufacturer s list. Some owner/operators develop installation details for each type of technology. These owner/operators then analyze the installation itself to ensure that the core attributes of a protective system are achieved, e.g., independence, functionality, integrity, reliability, auditability, access security, and management of change. This provides a consistent operator and maintenance interface and allows the analysis and testing for device approvals to be limited to the device and its ability to work within the existing approved installations. For PE logic solvers, performance is generally dictated by how well the safety manual is followed, how recommended upgrades are executed, and whether the manufacturer s recommended operating environment is maintained. When implemented according to manufacturer s recommendations, PE logic 12621 Featherwood Drive, Suite 120 Houston, Texas 77034

solvers tend to achieve the reported level of safety. This does not necessarily mean that the PE logic solver has the robustness to provide the trouble free service that may be desired. In general, PE logic solvers tend to fail-safe more frequently than reported by analysis. This is largely due to violation of the operating environment requirements or human error. Prior Use History In general, manufacturer failure rate data is 3 to 10 times better for programmable devices than the actual performance observed in the process industry. For mechanical devices, the ratio is 30 to 100 times better. Programmable electronic systems are not immune, with some certifications assuming diagnostics coverage factors that are simply not achievable using current practices. Because of the discrepancy between manufacturer and owner/operator environments, devices should be selected based on demonstrated history in a similar operating environment. The intent of prior use is to gain an understanding of the device s failure modes so that the design and operating basis can take them into account. Previous operating experience provides valuable information for the selection of field devices, because it identifies how the operating environment degrades the theoretical performance claimed by the manufacturer. For some devices, especially field devices, evidence of successful operating experience in similar process applications is very important. In IEC 61508, this is called proven-in-use; while in IEC 61511, it is called prior use. There are specific requirements and limitations regarding the prior use evaluation in IEC 61511 Clauses 11.4 and 11.53 through 11.5.6. The requirements vary depending on the device type (sensor, logic solver, final element) and whether the device uses programmable elements. If the device is programmable, the requirements also vary dependent on whether fixed programmable language or limited variability language is used to configure the device. These requirements are further discussed in ISA TR84.00.04 Annex L. For SIS, IEC 61511 requires devices be selected based on their expected performance in the operating environment. Maintenance records are a valuable information source. The plant maintenance tracking system can be used to flag devices that have repeatedly failed so that more detailed analysis can be performed. In general, it takes approximately three years of operating time to gain sufficient understanding of the failure modes of a field device. This operational time can be obtained in the actual or similar operating environment in process control, other non-sis applications, or at other owner/operator sites. Operational time can be gathered during alpha and beta testing where owner/operators work in close association with the manufacturer. Alpha testing is conducted to demonstrate the basic functionality of the device and general compatibility with the service. A successful alpha test leads to beta testing, which is usually conducted using multiple installations to gather information on the device failure modes in 12621 Featherwood Drive Suite 120 Houston, Texas 77034 Tel: (281) 922-8324 Fax: (281) 922-4362 www.sis-tech.com

August 22, 2008 Page 6 of 8 a variety of operating environments. However, alpha and beta testing results are not sufficient for approving devices for SIS service. Manufactures often provide references to other owner/operators who use their product. These references can often provide valuable insight into product application and use. In addition, the manufacturer user s group can provide valuable networking opportunities to gather information concerning product performance. The owner/operator may choose to rely on the manufacturer and other owner/operator s field experience or may choose to supplement this evidence with more direct experience. This may include bench testing and field trials in process control or low hazard services. Generally, the more unfamiliar or complex the technology is, the more time should be spent understanding how it works and how it fails. Proven performance takes on special significance for SIS, because most operate as dormant systems that only take action when a process demand occurs. In contrast, control system devices are expected to operate frequently, if not continuously, so failures in control system are rapidly detected. If these failures cannot be managed by the control system or operator, an independent SIS is often implemented to mitigate any unacceptable process risk. One of the strongest arguments for separation of the SIS and the control system is the common practice of using the latest technology in control applications. Many owner/operators who strive to use the newest control technology often find that the products are not as well developed as originally thought. New control system implementation can turn into an unplanned product development project. While necessary for production or quality reasons, this can be a hazardous practice for SIS. Proven operating history cannot be underestimated. Summary User approval is an important aspect of complying with ANSI/ISA 84.00.01-2004. User approval relies of predictive evidence, such as analysis and testing reports, balanced with field operating history. While some manufacturers are now providing devices that are certified for use in safety instrumented systems (SIS), these devices are relatively limited in their range of application and technology. Many are not field proven and some are not demonstrating the robustness necessary to survive a chemical plant environment. Within an IEC 61508 analysis, an unreal operating environment is often assumed: one that does not include the process impact, ambient conditions, stress, manufacturing defects, software errors, installation issues, electrical disturbances, instrument air or other support system quality problems, etc. Consequently, owner/operators in the process sector should rely heavily upon operating experience for selection of devices for SIS, especially for those devices installed in the process environment. User approval seeks to get the proper balance of analysis/testing information and field experience. The amount of information or experience required and the degree of rigor associated with their evaluation may vary, depending on the nature of the device and the required safety integrity level. The key point to the user approval process is to establish sufficient evidence to justify that the device can and does achieve the required performance in the intended operating environment. 12621 Featherwood Drive, Suite 120 Houston, Texas 77034

References Instrumentation, Systems, and Automation Society (ISA), ANSI/ISA S84.01-1996, Application of Safety Instrumented Systems (SIS) for the Process Industry, Research Triangle Park, NC (1996) Occupational, Safety and Health Administration (OSHA), Process Safety Management of Highly Hazardous Chemicals; Explosives and Blasting Agents, 29 CFR Part 1910. Federal Register 57,36, Washington, DC (1992). International Electrotechnical Commission (IEC), IEC 61508, Functional Safety of Electrical/Electronic/Programmable Electronic Safety Related Systems, Parts 1-7, Geneva, Switzerland (1999-2001). International Electrotechnical Commission (IEC), IEC 61511, Functional Safety: Safety Instrumented Systems for the Process Sector, Geneva, Switzerland (2003). 12621 Featherwood Drive Suite 120 Houston, Texas 77034 Tel: (281) 922-8324 Fax: (281) 922-4362 www.sis-tech.com

August 22, 2008 Page 8 of 8 12621 Featherwood Drive, Suite 120 Houston, Texas 77034