Model RS72. Model RSCS280A. Model RSM2680

Similar documents
Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Model D24-1S. Model D24-2S

GERMICIDAL ULTRAVIOLET FIXTURES

GERMICIDAL ULTRAVIOLET IRRADIATORS

ULTRAVIOLET INDIRECT AIR DISINFECTION

ULTRAVIOLET PORTABLE AREA SANITIZER

ULTRAVIOLET SANITARY CONDIT IONERS

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Document No C Revised January Atlantic Ultraviolet Corporation

7-ASC / 8-ASC / 9-ASC

Models 2B-SC, 3B-SC, 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC, 6B-ASC. Models 2B-SC, 3B-SC. Models 6B-ASC. Installation, Operation & Maintenance

NO4G, NO4GS, NO6G, NO6GS

Document No B Revised June Atlantic Ultraviolet Corporation

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Document No A3 Revised February Atlantic Ultraviolet Corporation

Document No A9 Revised August Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Model G48HO Remote Controlled Sanitizer

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Document No A1 Revised September Atlantic Ultraviolet Corporation

Document No B1 February Atlantic Ultraviolet Corporation

Ultraviolet Air Disinfection Equipment

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

UVC in the Operating Room.

S17A, S23A, S37C & S50C

AMERICAN AIR & WATER, INC.

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

ULTRAVIOLET WATER PURIFIERS

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

ULTRAVIOLET WATER PURIFIERS

PCO/UV N-Duct Model. Owner s Guide

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

Liquid Storage Tank Conditioners

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Purifying air at the. Light. speed of. Carrier Corporation 2007 is a member of the United Technologies Corporation family, stock symbol UTX.

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

PURPOSE OF THE PROCEDURE

GRU-V Air Purifier. Product Manual

PURION UV plants for disinfection

or

1020 Industrial Drive, Orlinda, TN fax

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Ballast MIN A

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier

Add the Power of Indigo-Clean Disinfecting Technology to your Facility Lighting

254 Nanometer Germicidal UV Disinfection Systems

ULTRA-VIOLET STERILIZATION

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

Supplement 3: Engineering Controls

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

A measured step forward

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Biological Safety Cabinets. Biological Safety Cabinets

How to comply with CDC Guidelines

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Document No E1 Revised February Atlantic Ultraviolet Corporation

LEARNING SPECIAL HAZARD DETECTION TYPES

Installation and Operating Instructions. Rev. 3/24/17. Continuous Antimicrobial Air Cleaner

CA3500, BA3500, CH3500 New Comfort

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

Safe Operating Procedure (Revised 2/10)

Infrared Heaters For Controlled Concentrated Curing

Biological Safety Cabinets or Fume Hoods Which one to use?

HEALTHY CLIMATE PureAir Air Purification System

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

healthy comfort Indoor Air Quality Solutions

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Intensive UV light means not a chance for germs!

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Safety Manual Section 15 Radiation Safety

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

Prepared for. MRC National Tuberculosis Research Programme. and the. South African Centre for Essential Community Services

RS4 Whole House IAQ System

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Instruction Manual E4 ChamberIR Heater

UV measurements for medical applications using SiC photodiodes

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

UV I UNIT030W / UV I UNIT055W

Appendix C IBC Safe Use of Biosafety Cabinets SOP

Innovation in air purification unmatched air quality

Introducing the most technically advanced indoor air treatment system

ACCELERATE YOUR CURING TIME

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Loctite Zeta 7600 Ultraviolet Curing Conveyor Part Number EQUIPMENT Operation Manual

Perfect Air Purifiers

Model CWA200 Owner s Manual

Transcription:

RS72 RSCS280A RSM2680

ABOUT US GERMICIDAL ULTRAVIOLET Since 1963, Atlantic Ultraviolet Corporation has pioneered the discovery and development of beneficial uses of ultraviolet energy. Over the years these efforts have led to the development of valuable, cost effective and environmentally sound techniques and products now known and respected throughout the world. The UV Application Specialists at Atlantic Ultraviolet Corporation assist customers in the selection of germicidal lamps and equipment. Their specialized knowledge is a valuable resource in formulating effective and cost-conscious ultraviolet solutions. Ultraviolet is a unique and rapid method of disinfection. It utilizes germicidal ultraviolet lamps producing short-wave radiation at 254 nanometers (nm) a wavelength that is highly lethal to bacteria, virus, and other microorganisms. An ever growing range of industries and consumer applications have found ultraviolet to be the ideal solution for their air and surface treatment needs. Atlantic Ultraviolet Corporation equipment and systems are manufactured in the USA. Extensive inventories and a dedicated staff enable Atlantic Ultraviolet Corporation to fulfill its commitment to provide fast deliveries and responsive customer service. RS140 free standing, wall or ceiling mount in occupied areas RSCS280A recessed ceiling mount in occupied areas RSM2680 mobile, for use in occupied areas 2

ADVANTAGES PRINCIPLE OF OPERATION Economical System requires very little power to operate. Safe No risk of over-exposure. Fast Disinfects air in seconds. The SANITAIRE design has been carefully conceived to provide adequate germicidal ultraviolet exposure for air disinfection in occupied areas. The dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air is exposed. Our UV application specialists would be happy to perform the necessary calculations to ensure the model we provide is appropriate for your particular application. Air Drawn In RS435 wall or ceiling mount in occupied areas Easy Some models require no installation. Automatic Continuous disinfection without special attention. Durable Polished Stainless Steel and Aluminum. Versatile Numerous models available to handle various configurations, some models are relatively portable and can be applied to different occupied areas as needed. Low Maintenance Annual Lamp replacement and periodic cleaning is required. The operation of the SANITAIRE is as follows: Air Drawn In Air Flow Observation Port(s) Louvered Exhaust Panel Air is drawn into SANITAIRE model through the washable electrostatic particulate filters (except RSM2680 which utilizes disposable filters). The air is forced into the ultraviolet exposure chamber where it is irradiated by germicidal ultraviolet light (lamp quantity varies per model). Observation Port/Sight Glass provides positive indication of germicidal lamp operation. The purified air exits the sanitizer, through the louvered exhaust panel, located at the opposite end of the sanitizer. In the case of the SANITAIRE RSA760, once through the louvered exhaust panel, air is forced through a.3 micron HEPA filter and finally through an electrostatic particulate filter before exiting the sanitizer into occupied areas. ultraviolet.com buyultraviolet.com 3

SPECIAL FEATURES SANITAIRE RS72, RS140, RS435, and RSA760 Free Standing, Wall, or Ceiling Mount Sanitizer Utilize SANITAIRE Room Air Sanitizers to protect occupants including but not limited to personnel, clients and patients from infection due to airborne microbes, particularly in crowded or poorly ventilated areas, and in situations where the risk of cross infection is high. SANITAIRE Room Air Sanitizers are germicidal ultraviolet fixtures that effectively destroy airborne microbes including bacteria, mold and virus in enclosed occupied spaces and are available in a number of different configurations to adapt to any setting. SANITAIRE Room Air Sanitizers utilize STER-L-RAY Germicidal Ultraviolet Lamps which are completely enclosed within a stainless steel and reflective aluminum exposure chamber and are safe for use in most applications. STER-L-RAY Germicidal Ultraviolet Lamp(s) Lamp(s) are instant starting and provide the utmost in quality, sustained output, and longevity. (See page 11 for more information.) Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the model when the access panel is unhinged for lamp or filter replacement (located under the cover). Surelite Ballast(s) State-of-the-art electronic ballast specifically developed for the operation of ultraviolet lamps. Versatile ballast provides high lamp output; is lightweight, efficient, and operates cool for longer life. Steadfast Lampholders Set includes a stationary and a springloaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Louvered Exhaust Panel Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. Polished Reflector Interior surface is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. Stainless Steel Enclosure Manufactured in Type 304 stainless steel for unparalleled strength, durability, and an attractive finish. RS435 (See page 10 for Optional Accessories) Promate Observation Port/ Sight Glass Assembly A Sight Glass Assembly allows for visual inspection of the lamp(s). Promate Particulate Filter(s) Washable Electrostatic Filter (on all models) Absolute Filter - HEPA Type (on RSA760) Promate Standard Wall Mount Kit Consists of (2) pre-drilled stainless steel brackets. Brackets enable model to be mounted to wall in either the vertical or horizontal position (included). 4

INSTALLATION Figure 1 - SANITAIRE RS140 (shown) For maximum efficiency the SANITAIRE should be located as centrally as possible, preferably not close to the floor or the corners of the occupied area to be treated. The louvered exhaust panel, of the SANITAIRE Room Air Sanitizer, restricts ultraviolet radiation from passing into the room, protecting the room s occupants from ultraviolet exposure. RS72, RS140, RS435 and RSA760 are commonly installed utilizing wall mounting brackets included with purchase. See page 10 for optional mounting brackets. Promate Observation Port / Sight Glass Assembly A Sight Glass Assembly allows for visual inspection of the lamp(s). SPECIFICATIONS SANITAIRE RS72, RS140, RS435, AND RSA760 SANITIZER Nominal Capacity (cubic feet / minute) Dimensions Length Width Height Electrical Requirements* (amps) Max. Room Size Treated at 3 Room Air Changes/Hour (cubic feet) Max. Room Size Treated at 6 Room Air Changes/Hour (cubic feet) Max. Treament Capacity (cubic feet / hour) RS72 54 34-1/2 7-3/4 7-3/4 1.25 1,080 540 3,240 RS140 105 34-1/2 7-3/4 7-3/4 2.30 2,100 1,050 6,300 RS435 326 47-5/16 14 12 4.52 6,525 3,263 19,575 RSA760 380 61 14 12 5.65 7,600 3,800 22,800 capacity incorporates an estimated allowance for airflow friction loss across filter and model. Information listed refers to 120 Volt 60 Hz models. Contact factory for specifics on other voltages. * Consult factory with specific power requirements. GENUINE STER-L-RAY GERMICIDAL LAMP DATA Lamp No. (Quantity) Lamp Length Lamp Length (including lampholders) Power Consumption Ultraviolet Output (per lamp) Rated Average Effective Life RS72 05-1348-R (1) 21-7/8 (556 mm) 24 30.7 Watts 8.5 Watts 10,000 Hours RS140 05-1348-R (2) 21-7/8 (556 mm) 24 61.4 Watts 8.5 Watts 10,000 Hours RS435 05-1352-R (4) 27-7/8 (708 mm) 30 153.6 Watts 11.2 Watts 10,000 Hours RSA760 05-1352-R (4) 27-7/8 (708 mm) 30 153.6 Watts 11.2 Watts 10,000 Hours Wattage is Lamp Watts and ballast loss (approximate). Output at 254 nanometers at 100 hours and 80 F (approximate). ultraviolet.com buyultraviolet.com 5

SPECIAL FEATURES SANITAIRE RSCS280A Recessed Ceiling Mount Sanitizer Utilize SANITAIRE Room Air Sanitizers to protect occupants including but not limited to personnel, clients and patients from infection due to airborne microbes, particularly in crowded or poorly ventilated areas, and in situations where the risk of cross infection is high. SANITAIRE Room Air Sanitizers are germicidal ultraviolet fixtures that effectively destroy airborne microbes including bacteria, mold and virus in enclosed spaces and are available in a number of different configurations to adapt to any setting. SANITAIRE Room Air Sanitizers utilize STER-L-RAY Germicidal Ultraviolet Lamps which are completely enclosed within a stainless steel and reflective aluminum exposure chamber and are safe for use in every application. STER-L-RAY Germicidal Ultraviolet Lamps Lamps are instant starting and provide the utmost in quality, sustained output, and longevity. (See page 11 for more information.) Steadfast Lampholders Set includes a stationary holder that holds a four pin lamp securely. Surelite Ballasts State-of-the-art electronic ballasts specifically developed for the operation of ultraviolet lamps. Versatile ballasts provide high lamp output; are lightweight, efficient, and operate cool for longer life. Louvered Exhaust Panel Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. Lamp Operation Indicators (LEDs) Provide positive indication of each germicidal lamp operation. Polished Reflector Interior surface is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. Stainless Steel Enclosure Manufactured in Type 304 stainless steel for unparalleled strength, durability, and an attractive finish. RSCS280A (See page 10 for Optional Accessories) Promate Particulate Filter Washable Electrostatic Filter Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the model when the access panel is unhinged for lamp or filter replacement (located under the cover). 6

INSTALLATION Figure 2 - The SANITAIRE RSCS280A (shown) is recommended for use in rooms with suspended T-Bar ceilings. Professional installation recommended. SPECIFICATIONS SANITAIRE RSCS280A RECESSED CEILING MOUNT SANITIZER Dimensions Nominal Electrical Requirements* Max. Room Size Treated at 3 Room Air Changes/Hour (cubic feet) Max. Room Size Treated at 6 Room Air Changes/Hour (cubic feet) Max. Treament Capacity (cubic feet / hour) 4,200 2,100 12,600 Capacity (cubic feet / minute) Length Width Height (amps) RSCS280A 210 46-5/8 22-1/8 9-7/16 4.2 capacity incorporates an estimated allowance for airflow friction loss across filter and model. Information listed refers to 120 Volt 60 Hz models. Contact factory for specifics on other voltages. * Consult factory with specific power requirements. GENUINE STER-L-RAY GERMICIDAL LAMP DATA Lamp No. (Quantity) Lamp Length (including lampholders) Lamp Length Power Consumption Ultraviolet Output Rated Average Effective Life RSCS280A 05-0497 (4) 27-7/8 (708 mm) 30 153.6 Watts 11.2 Watts 10,000 Hours (per lamp) Wattage is Lamp Watts and ballast loss (approximate). Output at 254 nanometers at 100 hours and 80 F (approximate). ultraviolet.com buyultraviolet.com 7

SPECIAL FEATURES SANITAIRE RSM2680 Mobile Air Sanitizer Utilize SANITAIRE Room Air Sanitizers to protect occupants including but not limited to personnel, clients and patients from infection due to airborne microbes, particularly in crowded or poorly ventilated areas, and in situations where the risk of cross infection is high. SANITAIRE Room Air Sanitizers are germicidal ultraviolet fixtures that effectively destroy airborne microbes including bacteria, mold and virus in enclosed occupied spaces and are available in a number of different configurations to adapt to any setting. SANITAIRE Room Air Sanitizers utilize STER-L-RAY Germicidal Ultraviolet Lamps which are completely enclosed within a stainless steel exposure chamber and are safe for use in every application. STER-L-RAY Germicidal Ultraviolet Lamps Lamps are instant starting and provide the utmost in quality, sustained output, and longevity. (See page 11 for more information.) Surelite Ballasts State-of-the-art electronic ballasts specifically developed for the operation of ultraviolet lamps. Versatile ballasts provide high lamp output; are lightweight, efficient, and operate cool for longer life. Steadfast Lampholders Set includes a stationary and a springloaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the model when the access panel is unhinged for lamp or filter replacement (located under the cover). Polished Reflector Interior surface is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. RSM2680 (See page 10 for Optional Accessories) Louvered Exhaust Panel Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. Lamp Operation Indicators (LEDs) Provide positive indication of each germicidal lamp s operation. Stainless Steel Enclosure Manufactured in Type 304 stainless steel for unparalleled strength, durability, and an attractive finish. Promate Disposable Filters Cost effective, disposable filters for frequent filter changes. Differential Air Pressure Gauge Used to measure filter resistance by measuring the pressure differential between outside (the fixture) air and the pressure in the blower compartment helping to indicate when filter replacement is required. 3-Position Power Switch Power to the fixture is controlled by a three position key switch. In the BLOWER ONLY position, power is supplied to just the blower and no power is supplied to the germicidal lamps. In the LAMPS & BLOWER position, power is supplied to both the blower and the germicidal lamps. 8

INSTALLATION Figure 3 - SANITAIRE RSM2680 (shown) The RSM2680 Room Air Sanitizer is mobile, and requires no professional installation. Simply roll the fixture into the occupied area to be treated, and plug into an appropriate power source. When in operation, air is drawn into the fixture through the four louvered Filter Panels, located around the base of the fixture. The air passes into the exposure chamber, where it is irradiated by twelve (12) STER-L-RAY Germicidal Ultraviolet Lamps. The air then passes out of the fixture, through the louvered Exhaust Panel, located on the top of the fixture. The Louvered Exhaust Panel of the fixture protects the room s occupants from ultraviolet exposure, by restricting ultraviolet radiation from passing into the occupied room. SPECIFICATIONS SANITAIRE MOBILE AIR SANITIZER RSM2680 Nominal Capacity (cubic feet / minute) Dimensions Length Width Height Electrical Requirements* (amps) Max. Room Size Treated at 3 Room Air Changes/Hour (cubic feet) Max. Room Size Treated at 6 Room Air Changes/Hour (cubic feet) Max. Treament Capacity (cubic feet / hour) RSM2680 2000 32 30 78-3/4 11.00 40,000 20,000 120,000 capacity incorporates an estimated allowance for airflow friction loss across filter and model. Information listed refers to 120 Volt 60 Hz models. Contact factory for specifics on other voltages. * Consult factory with specific power requirements. GENUINE STER-L-RAY GERMICIDAL LAMP DATA Lamp No. (Quantity) RSM2680 05-1334-R (12) Lamp Length 45-7/8 (1165 mm) Lamp Length (including lampholders) Power Consumption Ultraviolet Output (per lamp) Rated Average Effective Life 48 792 Watts 21.0 Watts 10,000 Hours Wattage is Lamp Watts and ballast loss (approximate). Output at 254 nanometers at 100 hours and 80 F (approximate). ultraviolet.com buyultraviolet.com 9

OPTIONAL ACCESSORIES APPLICATIONS SENTINEL Remote Lamp Indicator* The SENTINEL Remote Lamp Indicator monitors lamp operation of one, two, or four lamp ultraviolet fixtures and is available with a 25, 50 or 100 foot cable. (Available for ALL SANITAIRE models except for RSM2680, at the time of purchase, SENTINEL output connector needs to be installed for easy plug-in and operation.) Zenith Ultraviolet Meter A sensitive, hand-held, ultraviolet meter that can be used to Survey installations to ensure that the germicidal ultraviolet radiant exposure, of personnel within the treated area, is within acceptable limits. The Zenith Ultraviolet Meter provides accurate and easy-to-read levels of intensity that may be interpreted by anyone not just engineers. Check the intensity of aging ultraviolet lamps. (Available for ALL SANITAIRE models.) ArmorLite Safety Shield Protective coating applied to STER-L-RAY Germicidal Lamps ensures protection for employees, products and work environments by eliminating the dangers associated with fragments of broken lamps and mercury contamination. (Available for STER-L-RAY Lamps used in ALL SANITAIRE models.) Promate Disposable Filters Cost effective, filters for use when frequent filter changes are necessary. (Available for ALL SANITAIRE models.) Promate Optional Wall Mount Kit Consists of (2) pre-drilled stainless steel brackets. Brackets are designed to provide a more aesthetic look for the installation while allowing model to be mounted to the wall in a horizontal position. (Available for SANITAIRE RS72, RS140, RS435 and RSA760.) Promate Ceiling Mount Kit Consists of (4) eye bolts used to suspend model from ceiling. (Available for SANITAIRE RS72, RS140, RS435 and RSA760.) Promate Integral Elapsed Time Indicator* The Elapsed Time Indicator is a real-time, non-resettable display of accumulated operating time. Useful for scheduling and recording maintenance and lamp replacement. (Available for ALL SANITAIRE models.) Promate Integral Key Lock Switch* The Key Lock Switch will ensure tamper proof operation in either ON or OFF position. (Available for ALL SANITAIRE models.) * Item must be ordered at same time as SANITAIRE Room Air Sanitizer (installed at factory). office buildings waiting rooms laboratories hospitals clinics maternity areas labor & delivery areas pathology labs kidney dialysis labs operating rooms methadone clinics burn centers TB clinics homeless shelters prisons and jails detention centers nursing homes universities schools veterinary clinics animal husbandry kennels food industry food processing dairy processing bakeries auditorium conference rooms ballrooms gymnasiums clean rooms pharmaceutical mfg. electronic production cosmetic production plus countless other facilities 10

GENUINE STER-L-RAY GERMICIDAL LAMPS Relative Spectral Energy Distribution (Typical) Germicidal Effectiveness As Related to Wavelength 100 100 INTENSITY 80 60 40 20 RELATIVE EFFECTIVENESS 80 60 40 20 0 100 200 300 400 500 600 0 200 225 250 275 300 WAVELENGTH (NANOMETERS) WAVELENGTH (NANOMETERS) STER-L-RAY Germicidal Lamps are shortwave, low pressure tubes that produce ultraviolet wavelengths lethal to microorganisms. Approximately 95% of the ultraviolet energy emitted from STER-L-RAY germicidal lamps is at 254 nanometers, the region of germicidal effectiveness most destructive to bacteria, mold and virus. STER-L-RAY and the STER-L-RAY logo are trademarks of Atlantic Ultraviolet Corporation. CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: LampRecycle.org. ULTRAVIOLET DOSAGE Germicidal lamps provide effective protection against microorganisms. A small cross-section is shown below. ORGANISM ALTERNATE NAME TYPE DISEASE DOSE* Corynebacterium diphtheriae C. diphtheriae Bacteria Diptheria 6.50 Legionella pneumophila L. pneumophila Bacteria Legionnaire s Disease 2.70 Mycobacterium tuberculosis M. tuberculosis Bacteria Tuberculosis (TB) 10.00 Pseudomonas aeruginosa P. aeruginosa Bacteria 3.90 Serratia Marcescens S. marcescens Bacteria 6.160 Staphlylococcus aureus S. aureus Bacteria 6.60 Staphlylococcus epidermidis S. epidermidis Bacteria 5.80 Adeno Virus Type III Virus 4.50 Coxsackie A2 Virus 6.30 Influenza Virus Flu 3.40 * Nominal Ultraviolet dosage (mj/s 2 ) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing. ultraviolet.com buyultraviolet.com 11

The Standard of Excellence In Ultraviolet Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment & Lamps 375 Marcus Boulevard Hauppauge, NY 11788 631.273.0500 Fax: 631.273.0771 E-mail: Sales@AtlanticUV.com Ultraviolet.com BuyUltraviolet.com The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice. Document No. 98-1096 August 2018 2018 by Atlantic Ultraviolet Corporation