MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Similar documents
2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Pump - Owner s Manual

INSTALLATION & OPERATING INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

CHAMPION PUMP OWNER S MANUAL

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

LC Series - Light Commercial Pump Station Installation and Operation Manual

QUIETFLO OWNER S MANUAL

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

OWNERS GUIDE TO INSTALLATION AND OPERATION

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

Elite Primer Baldor Series External Pond Pump

SAVE THIS INSTRUCTION MANUAL

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

INSTALLATION OPERATION MAINTENANCE LANCASTER MODELS X99M33 & X99M50

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

CHALLENGER CENTRIFUGAL PUMP

SuperFlo High Performance Pump

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

VL Series Pump. Owner s Manual. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

INSTALLATION INSTRUCTIONS

HIGH PERFORMANCE 3-PHASE PUMPS

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

AQUA-FLO A SERIES. The Bronze Pump designed exclusively for any swimming pool or spa application.

BACK WASH INSIDE THE SPA

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

PRO-230 PRO-350 PRO-400 PRO-500 PRO-500DS ECO-PRO

Pool Weasel Vacuum Users Guide

SUBMERSIBLE WATER PUMPS

Installation instructions for the T 9820 Gas Dryer

HIGH PERFORMANCE PUMP

Dishwasher Installation Manual

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

HIGH PERFORMANCE PUMPS

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

HAYWARD POOL PRODUCTS, INC. 620 DIVISION STREET ELIZABETH, NJ (908) OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

WINTERIZATION INDUSTRY BEST PRACTICE

Model K 520 M Part No

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Next Generation Corona Discharge Installation & Operation Manual

K 3.97 M. Specifications or visit our website: In USA call: Part No

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Jacuzzi J-D300 Pool Cleaning System

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

Fully Automatic Water Softeners

ASSEMBLY INSTRUCTIONS

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

BEFORE OPERATING THE MACHINE: WARNING

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Owner s Manual. Models SP32950VSP Variable Speed Pump SAVE THIS INSTRUCTION MANUAL

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

SERIES ABG SWIMMING POOL PUMP

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

KREEPY KRAULY PROWLER 910 ROBOTIC ABOVEGROUND POOL CLEANER

owner s manual & parts list

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Models Series Series

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

INSTALLATION GUIDE NZ AU C

Models Series Series

AquaReef Cube. Inspiring Excellence in Fish Keeping!

This label warns for risk of electrical shock when failing to observe.

Ozone Generator Systems

Maxflo VS. Owner s Manual. MaxFlo VS Variable Speed Pump

Two Tier Illumifalls Patio Pond

SUPPLEMENTARY INSTRUCTIONS

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

DYNA-PRO TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Room Air Conditioner Service and Parts Manual

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Transcription:

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104

MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135 NEP2136 NEP2198 NEP2199 NEP2200 NEP2201 NEP2202 NEP6370 NEP2204 NEP2205 NEP2206 NEP2207 NEP2149 NEP2150 NEP2238 NEP2242 Manf. # AC 81361 AC 81396 AC 81434 AC 81744 AC 81760 AC 81779 AC 81795 AC 81817 AC 81876 AC 81884 AC 81892 AC 81914 AC 81922 AC 81590 AC 81620 AC 83429 AC 50520 De scri ption PUMP LID PUMP LID O-RING PUMP BASKET STRAINER CLIP STRAINER HOUSING PUMP COVER IMPELLER 1 HP IMPELLER 1.5 HP SEAL SET PUMP HOUSING PUMP HOUSING O-RING PUMP SCREWS PUMP COVER O-RING DRAIN PLUG O-RING DRAIN PLUG MOTOR FLANGE POWER CORD STANDARD

IMPORTANT SAFETY INSTRUCTIONS NOTE All wiring should be done by a qualified electrician in accordance to the National Electric Code and all Local Codes and ordinances. When installing and using this electrical equipment, basic safety precautions should ALWAYS be followed. READ AND FOLLOW ALL INSTRUCTIONS WARNING 1. To reduce the risk of injury, do not allow children to use this equipment 2. Connect only to a grounding type receptacle that is protected by a ground fault circuit interrupter (GFCI). 3. Do not bury the cord. Locate cord so it would come in contact with lawn mowers, trimmers or other equipment. 4. Do not connect this equipment to an extension cord. To reduce the risk of electric shock, only connect the electric cord to a properly located outlet. 5. To reduce the risk of shock, replace damaged cords immediately. Do not use this equipment if cord appears damaged. 6. To reduce the risk of shock, connect ground wires to the grounding screw located in the motor. 7. To reduce the risk of shock, a bonding connector is provided for bonding to any metal within 5 feet of the swimming pool. All local points should be bonded with #8AWG (8.4mm2) wire. NOTE To installer and/or operator of the Maxi- Force swimming pool pump: the manufacturer s warranty will be void if the pump is improperly installed and/or operated. 3

OPERATION AND MAINTENANCE PUMP LOCATION 1. Locate the pump on a level surface as close to the pool as practical. Consult local codes for minimum distances between pool and pump if applicable. 2. The connection plumbing (hose or rigid pipe) should be direct and as free from turns and bends as possible. Take care not to kink flexible hose. Elbows and other fittings greatly increase friction losses. 3. Place pump on a solid foundation / base which provides a rigid and vibration free support. 4. Protect the pump against flooding and excess moisture. Protect the motor from foreign objects clogging the air circulation around the motor. 5. NEVER use gasoline or other flammable liquids or vapors in the vicinity of this pump. NOTE DO NOT store pool chemicals near this pump. DO NOT remove any safety labels such as CAUTION / DANGER / WARNING from this pump. Keep labels in good condition and replace any damaged labels. WARNING Keep labels in good condition and replace any damaged labels 4

PUMP INSTALLATION 1. When connecting plumbing fittings to the pumps threaded ports, it is recommended that thread seal tape (Teflon tape) be used. If the suction (intake) connection is not sealed correctly the pump will not prime properly and will pump only small volumes of water or no water at all. 2. When installing the pump the suction line (hose or pipe) must be below the swimming pool water level to a point immediately beneath the pump to ensure priming via a flooded suction line. The height between the water line and pump should never be more than 5 feet. 3. Suction and discharge lines should be independently supported at a point near the pump to avoid strains being placed on the pump. 4. It is advisable to install a gate valve or union in both the suction and discharge lines in the event the pump needs servicing or removal. 5. Before starting the pump for the first time remove the clear lid at the front of the pump. Turn the lid counterclockwise to remove. Fill the pump strainer with water until it is level with the suction port opening. Replace the lid making sure the lid is tight and O-Ring is not damaged. Hand tighten only. 6. BONDING: as required by the National Electrical Code Article 680-26 the pump must be electrically bonded to the pool structure by a solid copper conductor no smaller than #8 AWG via the external copper bonding lug on the motor. 7. GROUNDING: Permanently ground the pump motor using a conductor of appropriate size. Connect to the green headed screw provided inside the motor terminal box. NOTE DO NOT CONNECT MOTOR TO THE ELECTRIC POWER SUPPLY UNTIL IT IS PERMANENTLY GROUNDED. 5

PUMP MAINTENANCE The pump requires little to no maintenance other than reasonable care and cleaning of the strainer basket on a regular basis. The pump is equipped with a mechanical seal. This seal may eventually come loose of a period of time, depending on running time and water quality. If water continually leaks out, a new mechanical seal should be installed. See parts diagram for seal location. The pump is equipped with a rubber O-Ring that seals the strainer basket lid. This O-Ring should be lubricated with water proof lubricant (O-RING LUBE) to ensure proper seal and extend O-Ring life. If O-Ring becomes cracked or worn (flattened) is will become necessary to replace. WINTERIZATION In areas subject to freezing temperatures, it is recommended that the pump be disconnected and stored indoors in a warm and dry location. Remove the drain plugs from the pump housing and place them in the strainer basket for storage. 6

DO NO BLOCK SUCTION 1. Pump suction is dangerous and can trap and drown or disembowel bathers. 2. Blocking suction with body may cause severe and/or fatal injury 3. Do not operate swimming pools, spas or hot tubs if a suction outlet cover is missing, broken or loose 4. Suction outlet must be replaced if cracked, broken or missing. 5. All suction outlets must have correctly installed screw fastened covers in place. WARNING RISK OF ELECTRICAL SHOCK 1. To avoid dangerous or fatal electrical shock, TURN OFF power to motor BEFORE working on electrical connections. 2. To reduce the risk of electrical shock, unplug motor before working on pump or motor. 7

TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE Pump will not Prime Motor Does Not Run Low Flow Suction Air Leak Make sure see thru lid and O-Ring are clean, lubed and tightened. Tighten all hoses and pipes on the suction side of the pump. Be sure water level in the swimming pool is high enough to flow through skimmer. Be sure skimmer port is not plugged or blocked. No Water in Pump Make sure strainer tank is full of water Closed Valves or Blocked Lines Open all valves in system. Clean skimmer and strainer basket. Check for blockage in impeller Low Voltage to Motor Check voltage at motor. If low, pump will not come up to speed No Power to Motor Check that all power switches are on. Be sure fuse or circuit breaker is properly set. Timer set correctly? Check moor wiring at terminals Pump Jammed With power off, turn motor shaft. It should spin freely. If not disassemble and repair Dirty Filter Backwash filter. When pressure is high you must backwash or clean filter Clean skimmer basket. Clean pump basket Suction Air Leak See above See above Closed Valve Motor Runs Hot 8 SOLUTION Motor is designed to run hot to the touch, this is normal. They are equipped with a thermal overload protector which will turn the motor off if there is an overload or high temperature problem. Excessive heat can be caused by: Poor Ventilation Do not enclose motor, be sure to have a proper air space around motor Installed in direct sun Shield motor from sun s rays