Electric water heaters

Similar documents
Electrical central storage heaters

Individual heat storage units

National Radon Action Plan and Radon Database

ESSENTIAL REQUIREMENTS CHECK LIST

IH 025 VOLCANO. Portable Induction Heater. smart mounting

Presto instant water heater. up to. less than. 5.7 kw. 0.5 kg.

SAR Technical Requirement

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Radon, a public health priority The concept of national radon programs in the WHO Radon Handbook

Hot Plate HPS / HPL. Bedienungsanleitung Instructions for use Mode d emploi Manuale d istruzioni Manual de instrucciones

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Dr. Daniel T. Gottuk Joshua B. Dinabug SUPDET 2014

Use and maintenance Manual Longitudinal profile welding Model: LRW-130

WHO International EMF Project 10th International Advisory Committee

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

INTERNATIONAL STANDARD

Specs for endconsumers. communication

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Installer: (Name, address, telephone number)

Electromagnetic Locking Devices

The New EMC Directive 2004/108/EC

EU Declaration of Conformity

Equipment Information

Where gas is not an option,

SCESm Directory Accreditation number: SCESm 0047

EMC Emissions in the Machine Industry

EC - RADON Latest strategies and draft regulations

Desktop Dual-band Radio Controlled Clock with Melody Alarm and Backlight Model: RM926 User Manual

EU Declaration of Conformity Lampenwerk Wipperfürth

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

The New EMC Directive 2004/108/EC

EU eclaration of Conformity

Important Safety Notice

EU Declaration of Conformity

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Wake-up Vibration Alarm Model : VR101. User Manual

Declaration of Conformity no. 56/2012

Hardware for Sliding Doors & Folding Doors

DOWNLOAD OR READ : ON THE FIELDS OF GLORY THE BATTLEFIELDS OF THE 1815 CAMPAIGN PDF EBOOK EPUB MOBI

OPERATING AND SAFETY INSTRUCTIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

Parkring Garching Germany. OSRAM Double-capped LED Lamp SubstiTUBE T8 ADVANCED HF El See attached list

Safety Data Sheet (in compliance with Regulation (EC) 1907/2006, Regulation (EC) 1272/2008 and Regulation (EC) 453/2010)

EU Declaration of Conformity Annex

30 VIENNARAIL DESIGN RADIATORS & TOWEL WARMERS VIENNARAIL.

White Paper. Effective and Energy Efficient Access Control in Commercial Buildings. The global leader in door opening solutions

CEN standardization work on refrigerating systems, especially standard EN 378

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

Installer: (Name, address, telephone number)

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Lawnmowers, pedestrian controlled (combustion engine powered)

Energy Efficiency in New Housing

COMMISSION DELEGATED REGULATION (EU) /... of XXX. on the classification of the frost resistance performance for clay tiles under EN 1304

Stationary and Portable Spas Important Safety Information

INTERNATIONAL STANDARD

Hazard Communication Self Inspection Checklist

EC-Declaration of Conformity

1. COOL ROOFS. What is a Cool Roof

INTERNATIONAL STANDARD

BEYOND COOKING: SMOKE ALARM NUISANCE SOURCES EVALUATED. Joshua B. Dinaburg, P.E. Dr. Daniel T. Gottuk, P.E. SUPDET 2016 March 4, 2016

This translation is for your convenience. It is not legally binding

This document is a preview generated by EVS

OPERATING INSTRUCTION MAGNETIC POLISHING MACHINE TYPE PM-200

Safety Manual Section 15 Radiation Safety

WATER TEMPERATURE MANAGEMENT POLICY

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

QAW70. Room Unit. Building Technologies. for use with heating controllers

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

BUSINESS PLAN CEN/TC 231 MECHANICAL VIBRATION AND SHOCK EXECUTIVE SUMMARY

Camping tents (ISO 5912:2011)

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Licensed Copy: Akin Koksal, Bechtel Ltd, 10 December 2002, Uncontrolled Copy, (c) BSI

BUSINESS PLAN CEN/TC 194 USTENSILE IN CONTACT WITH FOOD EXECUTIVE SUMMARY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

The results of the impact assessment and of the workshop will be considered in the final proposal of the new directive.

1. Terms defined in the Construction Products Regulation (CPR)

Controlled Door Closing Devices

INTERNATIONAL STANDARD

EU Declaration of Conformity Annex

Sergey Kiselev. SRC Federal Medical Biophysical Center

INTERNATIONAL STANDARD

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

Australian/New Zealand Standard

EUROPUMP ATEX Guideline Part II

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

ST 53.1 User s manual

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Electromagnetic Locking Devices Performance Requirements

smart mounting Induction Heater IH 070/090 Bedienungsanleitung Instructions for use Mode d emploi Manuale d istruzioni Manual de instrucciones

This document is a preview generated by EVS

Self-Luminous EXIT Signs Installation at EEO

Transcription:

Electric water heaters Date: 27 October 2016 Electric water heaters are fixed appliances for hot water production. When in operation, i.e. during the heat-up phase, they are the source of low-frequency magnetic fields. These fields occur in immediate proximity to the appliance and diminish rapidly with increasing distance. It is not known whether the long-term impact of low-frequency magnetic fields presents a health risk. No effects are expected from short-term exposure to low-frequency emissions from electric water heaters. Nevertheless, the following precautions will help to minimise exposure to the magnetic fields generated by electric water heaters: A minimum distance of 50 cm should be maintained between the electric water heater and sleeping places or spaces occupied for longer periods. NB Adjust the heater such that the water is heated up to a temperature of 60 C at least once a day in order to prevent the formation of pathogens (Legionella). In this regard take note of the FOPH recommendations Particular cantonal specifications may exist for electric heaters. Before installing a new individual heat storage unit enquire about them with the relevant cantonal energy departments Information to Legionella Cantonal energy departements Schwarzenburgstrasse 157, CH-3003 Bern

1 Technical data Voltage: Output: Frequency: 230 V / 400 V up to approx. 10 kw 50 Hz Electric water heaters comprise an insulated water cylinder, made from steel, austenitic stainless steel or copper alloy sheet, with an integrated electric heating system. Depending on the size of the cylinder, the heating system may incorporate one or more heating elements. Heat is generated by the flow of electric current through heating wires in the heating elements. This current generates a low-frequency magnetic field around the heating wires. The water temperature can be manually set to up to around 80 C, the recommended setting being 60 C. Higher temperatures promote scaling, corrosion and heat loss [1]. The water should be heated up to a temperature of 60 C at least once a day to prevent the proliferation of pathogenic agents (Legionella bacteria). Further information on Legionella bacteria (German only) is provided on the following FOPH webpage: Legionellose To minimise heat loss from pipe runs, electric water heaters tend to be placed near the hot-water draw-off points (kitchen and bathrooms), i.e. within the living environment. Depending on their storage capacity and the electricity provider's tariff system, the heaters may be run only on nighttime off-peak electricity or may need topping up during the daytime with on-peak or flat-tariff energy. The heat-up times, which depend on the water temperature, water quantity and heat output, can last up to several hours. 2 Exposure to low-frequency magnetic fields A survey commissioned by the FOPH (Federal Office of Public Health) set out to measure the magnetic fields generated by five different electric water heaters. The magnetic fields were observed to diminish rapidly with increasing distance from the appliance and, at 50 cm, are negligible. (Figure 1) 27. October 2016 Seite 2 von 5

Figure 1: Magnetic fields generated by water heaters as a function of distance from the appliance: Measurements taken in front of four floor-mounted models (capacity: 200-300 ltr, power: 2.7-5 kw) and one wall-mounted model (capacity: 150 ltr, power: 2 kw) 3 Impact on health Low-frequency magnetic fields can penetrate and induce electric current within the human body. When these currents exceed a certain value the central nervous system can be directly excited. The European threshold values for magnetic fields have therefore been set such that the current flowing in the body is at most one-fiftieth of the excitation threshold [2]. The magnetic fields (maximum 1.2 µt) from electric water heaters are much smaller than the threshold value of 100 µt. No effects are expected from short-term exposure as the present threshold values preclude acute damage. In 2002 the International Agency for Research on Cancer (IARC) classified static and low-frequency magnetic fields as possibly carcinogenic (Group 2B) [3]. This was based on epidemiological studies that suggest that long-term and durable exposure to magnetic fields in the low-dosage area of 1 μt or even lower (< 0.4 μt) could increase the risk of Alzheimer's disease [4,5] or of childhood leukaemia [6,7]. Magnetic fields of 0.4 μt or more occur at a distance of up to 30 cm around electric water heaters. The possible risk can be eliminated by keeping 50 cm away from the appliance. 27. October 2016 Seite 3 von 5

4 Regulation in law Electrical central storage heaters are classed as low-voltage products and governed, in Switzerland, by the Ordinance on Low-Voltage Electrical Products [8]. This ordinance requires that low-voltage products - both when used properly and, wherever possible, in predictable cases of misuse or in the event of foreseeable malfunctions - pose no danger to either persons or property. Only low-voltage products that meet the essential health and safety requirements specified by the European Low-Voltage Directive (2006/95/EC) may be brought into circulation. At the time any such a product is brought into circulation, the relevant manufacturer is required to issue a Declaration of Conformity confirming that the product complies with the essential requirements. The essential requirements for specific products are detailed in technical standards; electromagnetic fields produced by household appliances are covered by standard SN EN 62233 [9]. The conformity criteria set out here reflect the thresholds recommended by the EU [2] The manufacturers themselves are responsible for ensuring that their products comply with the conformity criteria. While Switzerland has no comprehensive system of market controls, the Swiss Inspectorate for High Current Installations (www.esti.admin.ch) carries out random conformity checks on marketed products. 27. October 2016 Seite 4 von 5

5 Literature 1. Borstelmann P, Rohne P. Handbuch der elektrischen Raumheizung. Heidelberg: Hüthig, 1993 2. RECOMMENDATION OF THE COUNCIL of 12 July 1999 on limiting the exposure of the population to electromagnetic fields (0 Hz - 300 GHz) (1999/519/EC)(1999/519/EC) 3. IARC. 2002. Non-ionizing radiation, Part 1: Static and extremely low-frequency (ELF) electric and magnetic fields. IARC Monographs on the evaluation of carcinogenic risks to humans, Volume 80. Lyon, France: International Agency for Research on Cancer. 4. Huss et al. Residence near power lines and mortality from neurodegenerative diseases: longitudinal study of the Swiss population. American Journal of Epidemiology. 169(2):167-75. 2009 5. Kheifets et al. Future needs of occupational epidemiology of extremely low frequency electric and magnetic fields: review and recommendations. Occupational and Environmental Medicine. 66(2):72-80. 2009 6. Kheifets et al. Pooled analysis of recent studies on magnetic fields and childhood leukaemia. British Journal of Cancer. 103(7):1128-35. 2010 7. Ahlbom et al. Review of the epidemiologic literature on EMF and Health; ICNIRP (International Commission for Non-Ionizing Radiation Protection) Standing Committee on Epidemiology. Environ Health Perspect. 109 Suppl 6:911-33. Review. 20011] 8. SR 734.26: Ordinance of 9 April 1997 on low-voltage electrical equipment (LVEO). 9. EN SN 62233 "Household and similar electrical appliances - Electromagnetic fields - Methods for evaluation and measurement" Specialist staff Federal Office of Public Health FOPH emf@bag.admin.ch 27. October 2016 Seite 5 von 5