TECHNICAL DATA OBSOLETE

Similar documents
TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

esfr pendent sprinkler vk510 (k25.2)

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

TECHNICAL DATA NOTICE

esfr pendent sprinkler vk510 (k25.2)

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

standard/quick response extended coverage light and ordinary hazard elo sprinklers

microfast and microfasthp quick conventional sprinklers

standard response dry horizontal sidewall sprinklers

esfr dry pendent sprinkler Vk501 (k14.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA. Page 1 of 6

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard response elo upright sprinkler

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

standard response dry horizontal sidewall sprinklers

quick response horizontal sidewall sprinkler vk360 (K8.0)

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

esfr dry pendent sprinkler Vk502 (k14.0)

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA OBSOLETE

standard response/ quick response extended coverage

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

microfast quick response extended coverage hsw sprinkler vk606

standard response large orifice dry

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

micromatic standard response stainless steel sprinklers

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

standard response Fusible Link Upright sprinkler VK204 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

standard response fusible link sidewall sprinkler VK112 (K5.6)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

Microfast quick response Fusible element hsw sprinkler

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

micromatic standard response Upright sprinkler VK100 (K5.6)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

microfast quick response Pendent sprinkler VK302 (K5.6)

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

microfast sr/qr extended coverage pendent sprinkler

Transcription:

November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high piled storage occupancies in accordance with NFPA 13 rules for Large Drop Sprinklers and FM Global criteria for Control Mode Specific Application (CMSA) and Large Drop Sprinklers. The sprinkler produces large water droplets through the use of an extra-large orifice and a special double deflector. The large water droplets provide the required mass to penetrate the fire plume of severe fires. This characteristic permits direct wetting of the burning fuel while cooling the atmosphere and can eliminate the requirement for in-rack sprinklers in certain cases. Viking VK540 Upright Large Drop Sprinklers are primarily intended to protect the following types of storage, which tend to produce severe-challenge fires: palletized and solid pile storage and single, double, multiple row, and portable open rack storage (no open-top containers or solid shelves). Viking High Challenge Upright Large-Drop Sprinkler VK540 provides protection of most common storage materials, including: --Class I, II, III, and IV commodities*. --Cartoned or exposed unexpanded plastics*. --Cartoned or exposed expanded plastics*. * Refer the Approval Chart on page 113c and Design Criteria on page 113d for culus and FM approval requirements that must be followed. In addition, some storage arrangements of idle wood pallets, rolled paper, aerosols, and rubber tires may be protected by Viking Upright Large Drop Sprinkler VK540. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2007 NYC Approved: MEA 89-92-E, Volume 19 NOTE: Other International approval certificates are available upon request. Refer the Approval Chart on page 113c and Design Criteria on page 113d for culus and FM approval requirements that must be followed. 3. Specifications: Available since 1996. Minimum Operating Pressure: Refer to Design Criteria on page 113d. Rated to 175 psi (12 bar) water working pressure. Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2 (15 mm) NPT or 3/4 (20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length: 3-5/16 (84 mm) Deflector Diameter: 3-5/8 (92 mm) Deflector: U.S.A. Patent No. 1,118,710 Material Standards: Frame Casting: Brass UNS-C84400 Screw: Brass UNS-C36000 Pip Cap: Leaded Bronze UNS-C31600 Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Form No. F_090595 Replaces page 113a-c dated April 21, 2006. (Reformatted.)

Sprinkler 113b November 2, 2007 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Deflector: Brass UNS-C26000 Ejector Spring: 17-7 Stainless Steel Bulb: Glass, nominal 5 mm diameter Ordering Information: (Also refer to the current Viking price list.) Order Standard Response High Challenge Upright Large-Drop Sprinkler VK540 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A Temperature Suffix ( F/ C): 155 /68 = B, 200 /93 = E, and 286 /141 = G For example, sprinkler VK540 with a 3/4 thread, a Brass finish, and a 155 F/68 C temperature rating = Part No. 13167AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Part No. 05118CW/B, fits both ½ NPT and ¾ NPT Sprinklers (available since 1981) Sprinkler Cabinet: Six-head capacity: Part No. 03985A (available since 1977) TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating 1 Ceiling Temperature 2 Frame Paint Color Bulb Color Ordinary 155 F (68 C) 100 F (38 C) None Red Intermediate 200 F (93 C) 150 F (65 C) White Green High 286 F (141 C) 225 F (107 C) Blue Blue Sprinkler Finish: Brass Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 2: Sprinkler VK540 Dimensions Figure 1: Sprinkler Wrench 05118CW/B

November 2, 2007 Sprinker 113c Base Part Number 1 SIN NPT Thread Size Approval Chart Standard Response High Challenge Upright Large Drop Sprinklers (Control Mode Specific Application) Maximum 175 PSI (12 bar) WWP Nominal K-Factor Overall Length Listings and Approvals 3 (Refer also to Design Criteria on page 113d.) Inches mm U.S. metric 2 Inches mm culus 4 FM NYC 5 VdS LPCB 13166 VK540 1/2 15 mm 11.2 161.3 2-5/16 84 A1 6 A1 6 A1 6 -- -- -- -- 13167 VK540 3/4 20 mm 11.2 161.3 2-5/16 84 A1 A1 A1 -- -- -- -- Approved Temperature Ratings A - 155 F (68 C), 200 F (93 C) and 286 F (141 C) Footnotes 1 Base part number shown. For complete part number, refer to the price list. Approved Finish 1 - Brass 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 19. 6 The ½ NPT Extra-Large Orifice Sprinkler is Listed and Approved for retrofit use only. 4. INSTALLATION WARNING: Viking sprinklers are manufactured and tested to meet rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. Viking High Challenge Sprinkler VK540 must be installed in accordance with NFPA 13 Large Drop Sprinkler rules and FM Global criteria for Control Mode Specific Application (CMSA) and Large Drop Sprinklers. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. A. Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped or damaged in any way or exposed to temperatures exceeding the maximum ambient temperature allowed (refer to Table 1). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb should be destroyed immediately. B. Wet pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to freezing must be listed dry sprinklers, or upright or horizontal sidewall sprinklers installed so that water is not trapped. C. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. D. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. E. With the sprinkler contained in the plastic protective shield, apply a small amount of pipe-joint compound or tape to the male threads only, while taking care not to allow a build-up of compound in the sprinkler orifice. F. Install the sprinkler on the piping using special sprinkler wrench 05118CW/B only, while taking care not to damage the sprinkler operating parts. (Any other type of wrench may damage the unit.) DO NOT use the sprinkler deflector to start or thread the sprinkler into a fitting. G. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Immediately replace any damaged units, using the special sprinkler wrench only.

Sprinkler 113d November 2, 2007 General Guidelines: Maximum Roof or Ceiling Slope: 2 in 12 (167 mm/m or 9.5 degrees). DESIGN CRITERIA (Also refer to the Approval Chart on page 113c.) Sprinkler Position: Approved for use only in the upright position. Align the deflector parallel with the ceiling or roof. System Type: Wet systems, dry systems, or preaction systems. NOTE: The use of internally galvanized steel pipe or copper pipe for dry systems and preaction systems using Large Drop Sprinklers is required by some Installation Standards. Deflector Distance from Walls: At least 4 (102 mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Clearance from Deflector to Top of Storage: At least 36 (914 mm). Minimum area of coverage allowed per sprinkler: 80 ft 2 (7.4 m 2 ). Minimum distance between sprinklers: 8 ft. (2.4 m). Hydraulic Calculation Note: To determine the number of sprinklers to calculate per branch line: Determine sprinkler spacing. (Refer to the appropriate Installation Standard and the Authority Having Jurisdiction.) Determine size of the remote area by multiplying the area of coverage per sprinkler by the number of sprinklers to be calculated (refer to the appropriate Installation Standard and the Authority Having Jurisdiction). Multiply the square root of the remote area determined in the step above by at least 1.2 and divide the product by the distance between sprinklers on the branch lines. The quotient determines the number of sprinklers to calculate per branch line. Any fractional sprinkler shall be carried to the next higher whole sprinkler. NOTE: If the ceiling is beam and girder or panel construction, locate sprinklers in the bays rather than under the beams. culus Listing Requirements: Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is culus Listed as indicated in the Approval Chart for installation in accordance with the latest appropriate NFPA standards (including NFPA 13) for Large Drop Sprinklers. Deflector Position: Under Unobstructed Construction: Position the deflector between 6 and 8 (152 mm to 203 mm) below the ceiling. Under Obstructed Construction, locate in accordance with one of the following: 1) Position the deflectors between of 6 and 8 (152 mm to 203 mm) below the ceiling. 2) Install with the deflectors within the horizontal planes 1 to 6 (25.4 mm to 152 mm) below wood joist or composite wood joist construction, to a maximum distance of 22 (559 mm) below the ceiling/roof or deck. 3) Install with the deflectors of sprinklers under concrete tee construction with stems spaces less than 7-1/2 ft. (2.3 m) but more than 3 ft. (0.9 m) on centers, regardless of the depth of the tee, located at or above a horizontal plane 1 (25.4 mm) below the bottom of the stems of the tees and shall comply with the obstruction rules in NFPA 13 for avoiding obstructions to discharge (Table 8.11.5.1.2 in the 2007 edition of NFPA 13). Maximum Distance Between Sprinklers: Under unobstructed and obstructed noncombustible construction and unobstructed combustible construction, the distance between sprinklers shall be limited to not more than 12 ft. (3.7 m) between sprinklers, with the area of coverage per sprinkler limited to 130 ft 2 (12.1 m 2 ). Under obstructed combustible construction and in rack storage applications, the distance between sprinklers shall be limited to not more than 10 ft. (3.1 m) between sprinklers, with the area of coverage per sprinkler limited to 100 ft 2 (9.3 m 2 ). The sprinkler installation and obstruction rules contained in NFPA 13 for Large Drop sprinklers must be followed. FM Approval Requirements: Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is FM Approved as indicated in the Approval Chart for installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-7, 2-8N, and 8-9) and Technical Advisory Bulletins for Control Mode Specific Application (CMSA) and Large Drop Sprinklers. Deflector Position: Position the top of the deflector 3-1/2 (89 mm) below the bottom of joists in wood joist construction, and 7 (178 mm) below the ceiling in all other types of construction. Refer to FM Loss Prevention Data Sheet 2-7 and 2-8N for exceptions. Maximum Distance Between Sprinklers: Limit the distance between branch lines and between sprinklers on branch lines to not more than 12 ft. (3.7 m). For open wood joist construction, limit the maximum distance to 10 ft. (3.0 m). The maximum area of coverage per sprinkler should not exceed 100 ft 2 (9.3 m 2 ). Refer to FM Loss Prevention Data Sheet 2-7 and 2-8N for guidelines. The sprinkler installation and obstruction rules contained in the FM Loss Prevention Data Sheets must be followed. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria.

November 2, 2007 Sprinkler 113e IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking High Challenge Upright Large-Drop Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest applicable Factory Mutual Loss Prevention Data Sheets (including 2-7, 2-8N, and 8-9), the latest standards of NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. H. After installation and testing and repairing of all leaks, remove the protective shields from the sprinklers. To remove the shield, simply pull the ends of the shield apart where it is snapped together. THE SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the NFPA standard that describes care and maintenance of sprinkler systems. In addition, the Authorities Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. The sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. The frequency of inspections may vary due to corrosive atmosphere, water supplies, and activity around the device. B. Sprinklers that have been painted or mechanically damaged must be replaced immediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. Refer to the Installation Standards (e.g., NFPA 25) and the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. 2. Using the special sprinkler wrench 05118CW/B, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response characteristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. 3. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. E. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY The Viking Model VK540 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_090595 Replaces page 113a-c dated April 21, 2006. (Reformatted.)