STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Similar documents
TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD/quick. Sprinkler 42o. August 8, 2011

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

mirage standard response concealed pendent sprinkler vk492 (K5.6)

microfast quick response Pendent sprinkler VK302 (K5.6)

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

standard response elo upright sprinkler

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

micromatic standard response Upright sprinkler VK100 (K5.6)

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

standard response Fusible Link Upright sprinkler VK204 (K8.0)

TECHNICAL DATA OBSOLETE

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

standard response/ quick response extended coverage

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

standard response large orifice dry

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

Standard Spray concealed horizontal sidewall sprinkler VK481

quick response horizontal sidewall sprinkler vk360 (K8.0)

microfast sr/qr extended coverage pendent sprinkler

micromatic Standard response Horizontal Sidewall sprinkler

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

freedom residential concealed pendent sprinkler vk474 (K5.8)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

standard response fusible link sidewall sprinkler VK112 (K5.6)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

Quick response concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

microfast quick response extended coverage hsw sprinkler vk606

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

sprinkler vk538 (K11.2)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

standard response elo upright and pendent sprinklers (storage-density/area)

freedom residential concealed pendent sprinkler VK488 (K3.0)

standard response dry horizontal sidewall sprinklers

freedom residential pendent sprinkler vk466 (K5.2)

Transcription:

Page of 5. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinkler VK5 is a thermosensitive glass bulb spray sprinkler pre-assembled with a threaded adapter for installation with a domed cover that provides up to ½ (.7 mm) of vertical adjustment. The cover plate is available with several decorative finishes to meet design requirements. The Electroless Nickel PTFE (ENT) finish has been investigated for installation in corrosive atmospheres and is listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant.) The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler.. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 05 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart and Design Criteria for culus Listing requirements, and refer to Approval Chart and Design Criteria for FM Approval requirements that must be followed.. Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 75 psi ( bar). Factory tested hydrostatically to 500 psi (4.5 bar). Thread sizes: /4 (0 mm) NPT Nominal K-Factor: 8.0 U.S. (5. metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length (sprinkler body): -5/6 (59 mm) Material Standards: Frame Casting: Brass UNS-C84400 VK5. Deflector: Phosphor Bronze UNS-C5000 or Copper UNS-C9500 Bulb: Glass, nominal mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Ejector Spring: 7-7 Stainless Steel Compression Screw: Brass UNS-C6000 Pip Cap and Insert Assembly: Copper UNS-C000 and Stainless Steel UNS-S0400 Cover Adapter: Cold Rolled Steel UNS-G0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Plate Assembly: Copper UNS-C000 and Brass UNS-C6800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) NOTE: Viking Standard/Quick Response Concealed Pendent Sprinkler VK5 and Cover Plate Assembly must be ordered separately. Sprinkler: Order Viking Standard/Quick Response Concealed Pendent Sprinkler VK5 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffixes: A = Brass, JN = ENT Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 55 F (68 C) = B, 75 F (79 C) = D, 00 F (9 C) = E For example, concealed sprinkler VK5 with a 55 F (68 C) temperature rating = 858ABX. NOTE: When ordering this sprinkler using the SIN, add suffix -D. For example, concealed sprinkler VK5 = VK5-D. Replaces Form No. F_0 Rev 7. (Added P65 Warning.)

Page of 5 Cover Plate Assembly: Base Part No. 8 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 5 F (57 C) = A (for use with 55 F (68 C) rated sprinklers only), 65 F (74 C) = C (for use with 75 F (79 C) or 00 F (9 C) rated sprinklers). For example, cover 8 with a Polished Chrome finish and a 5 F (57 C) temperature rating = 8FA. Available Finishes And Temperature Ratings: Refer to Table. Accessories: (Also refer to the Viking website) Sprinkler Wrench: Part No. 577W/B** (available since 006) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinet: Part No. 07A (available since 97) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 5 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Concealed Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE : AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Bulb Color Ordinary 55 F (68 C) 00 F (8 C) Red Intermediate 75 F (79 C) 50 F (65 C) Yellow Intermediate 00 F (9 C) 50 F (65 C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass or ENT (See Ordering Information section page ) Corrosion-Resistant Coatings : ENT The sprinkler temperature rating is stamped on the deflector. Based on NFPA-. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure : Concealed Sprinkler VK5 and Cover 8 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers the belleville spring is exposed.

Page of 5 Sprinkler Base Part Number SIN Thread Size Approval Chart (UL) Standard/Quick Response Concealed Pendent Sprinklers Maximum 75 PSI ( bar) WWP Nominal K-Factor Overall Length (Sprinkler Body) Listings and Approvals (Refer also to Design Criteria below.) NPT BSP U.S. metric Inches mm culus 4 NYC VdS LPCB Quick Response Applications 858A - X VK5 /4 0 8.0 5. -5/6 59 AW, BX -- -- -- -- 858JN - X 7 VK5 /4 0 8.0 5. -5/6 59 AW, BX -- -- -- -- 9784A - X VK5 /4 -- 8.0 5. -5/6 59 -- -- -- -- AW 57A - X VK5 -- 0 8.0 5. -5/6 59 -- -- -- -- AW Sprinkler Temperature Ratings A - 55 F (68 C) B - 75 F (79 C) and 00 F (9 C) C - 00 F (9 C) Cover Plate Assembly Temperature Ratings 5 W - 5 F (57 C) cover 8 X - 65 F (74 C) cover 8 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Finishes of the Cover Plate Assembly 6 - Polished Chrome, Painted White, Painted Ivory, or Painted Black Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 5 The 5 F (57 C) cover has an orange label. The 65 F (74 C) cover has a white label. 6 Standard painted finishes consist of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 7 culus Listed as corrosion-resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure. culus Listing Requirements: DESIGN CRITERIA - UL (Also refer to Approval Chart above.) Viking Concealed Pendent Sprinklers and VK5 is culus Listed quick response as indicated in Approval Chart for installation in accordance with the latest edition of NFPA for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA. Maximum spacing allowed is 5 ft. (4.6 m). Minimum spacing allowed is 6 ft. (.8 m) unless baffles are installed in accordance with NFPA. Minimum distance from walls is 4 in. (0 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA for standard coverage pendent spray sprinklers must be followed. DEFLECTOR POSITION: Install Concealed Pendent Sprinklers VK5 with the deflector /8 (9.5 mm) to 7/8 (. mm) below the ceiling. Refer to Figures 4 and 5. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_08064 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 4 of 5 Sprinkler Base Part Number SIN NPT Thread Size Approval Chart (FM) Standard Response Concealed Pendent Sprinklers Maximum 75 PSI ( bar) WWP Nominal K-Factor Inch mm U.S. metric Inches mm Overall Length (Sprinkler Body) FM Approvals (Refer also to Design Criteria below.) 858A-X VK5 /4 0 8.0 5. -5/6 59 AW, BX 858JN-X 6 VK5 /4 0 8.0 5. -5/6 59 AW, BX Sprinkler Temperature Ratings A - 55 F (68 C) B - 75 F (79 C) and 00 F (9 C) Cover Plate Assembly Temp. Ratings 4 W - 5 F (57 C) cover 8 X - 65 F (74 C) cover 8 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Finishes of the Cover Plate Assembly 5 - Polished Chrome, Painted White, Painted Ivory, or Painted Black Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 The 5 F (57 C) cover has an orange label. The 65 F (74 C) cover has a white label. 5 Standard painted finishes consist of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and Approvals apply for any paint manufacturer. Contact Viking for additional information. 6 FM approved as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure. FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart above.) Viking Concealed Pendent Sprinkler VK5 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet -0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_08064 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 5 of 5 Figure : Sprinkler Installation and Correct Use of Wrench Figure : Identification of Custom Paint Color for Concealed Covers Figure 4: Concealed Sprinkler VK5 Dimensions and Cover Installation Replaces Form No. F_0 Rev 7. (Added P65 Warning.)