Greenstar oil-fired. heating and hot water solutions. Product Guide 2018

Similar documents
Product Guide Oil-fired and solar thermal. heating and hot water solutions. Includes ErP ratings

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Bosch EasyControl. Smart heating and hot water control made Easy

Bosch EasyControl. Smart heating and hot water control made Easy

Greenstar regular and system gas-fired condensing wall mounted boiler range

Technical and Specification Information. Greenstore SC Cylinder series Greenstore TC Cylinder series. Greenstore Cylinder series NEW

Greenspring gas-fired condensing wall mounted continuous flow water heater. Includes ErP ratings. Technical and Specification Information

Greenstore unvented cylinder series. Technical and Specification Information. Greenstore unvented cylinder series

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Greenstar CDi Classic Regular Series Greenstar Ri Series. Greenstar regular gas-fired condensing wall mounted boiler range. Includes ErP ratings

PROFESSIONAL INSTALLER OFFER ONLY. cash-back on a Worcester Greenstar boiler for your own home. BBT4577e Installers Cashback 8pp A5 Lft MAY17.

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

The Greenstar CDi gas-fired condensing combi boiler series. Technical and specification information

DOMESTIC BOILER RANGE & ACCESSORIES.

The Worcester CondenseSure. An innovative solution to prevent freezing condensate NEW

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

INSTALLATION INSTRUCTIONS FOR FLUE KIT

The Greenstar CDi gas-fired condensing regular & system boiler series. Technical and specification information

The Greenstar Camray oil-fired regular and system condensing boiler series

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Greenstar Heatslave II oil-fired condensing combi boiler range. Includes ErP ratings. Technical and Specification Information

Worcester Controls range. Includes ErP ratings. Technical and Specification Information

Sirius FS. Working towards a cleaner future

Your heating and hot water in safe hands. Oil-fired boilers

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

cash-back on a Worcester Greenstar boiler for your own home

Sirius WH. Working towards a cleaner future

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Greenstar System Filter

Greenstar combi gas-fired condensing wall mounted boiler range

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Ridge End. DA Cooks. Progressing Meeting No:2. Neptune Responses Mechanical. 2 nd November 2015

Greenstar 12i/24i System

Compact HRE Boiler Range. The smart choice for heating and hot water

NEW BUILD YOUR COMPLETE SOLUTION.

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Easicom. Quality, reliability, flexibility

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Greenstar regular and system

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar regular gas-fired condensing wall mounted boiler range. Technical and Specification Information

24CDi, 28CDi & 35CDi II COMBI

Easicom 2. Quality, Reliability, Flexibility

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Vote for your Installer of the year at HEATSLAVE

ecotec range High efficiency condensing boiler range

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Your heating and hot water in safe hands. Gas-fired boilers

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

Greenstar 12i system / 24i system

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

GREENSTAR HIGHFLOW 440/550CDi

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

water solar heating SOLAR

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

ecotec plus 937 Power store high efficiency combination boiler

Greenstar 24i junior / 28i junior

Domestic Product Guide

heat interface units A BOILER WITHOUT A FLAME

GREENSTAR HIGHFLOW 440/550CDi

The Main Heating Range Guide. The Main Heating range of affordable combi, system and heat only boilers, cylinders and water heaters.

Discover a new level of efficiency

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Energy. The power of connectivity

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

The new ecotec exclusive from Vaillant with Green iq technology

Duo-tec combi, Megaflo system and Solo heat only boilers. Range guide

Ultimate 2. Technical boiler guide

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit


Our Boiler Family Our Boiler Family

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Ultimate 3. Range Brochure

Domestic boiler range. Why Vaillant? because they are the choice of a professional. ecotec exclusive ecotec plus ecotec pro

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Domestic Gas Boiler Guide

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

SEDBUK Band A Gas Condensing Boilers. The Greenstar range of high efficiency gas condensing boilers from Worcester

Transcription:

Greenstar oil-fired heating and hot water solutions Product Guide 2018

Greenstar oil-fired product range Our market-leading Greenstar oil-fired boilers are part of the total system solutions package we offer to installers. With state-of-the-art training facilities and award-winning technical support, we offer everything required to meet your heating and hot water needs. This easy-to-use pocket guide is intended as a quick reference document focusing on essential technical information such as dimensions, outputs, flue options, accessories and product codes. Details of where to find more information, both online and in other literature, are included at relevant places throughout the guide. 2

Contents Flues Components Terminal positioning Domestic oil boilers Combi System Regular Controls Greenstar Comfort Intelligent weather & load compensation controls Compatibility matrix Accessories Worcester CondenseSure Greenstar System Filter Greenstar Low Loss Header 4-7 8-13 14-17 18-23 24-31 32-33 34 35 36 37 37 Greenstore cylinders Unvented 38-39 Solar compatible unvented 40-41 Extended guarantees 42-43 Bosch commercial products 44-45 Useful reference information Worcester training 46-47 Useful contacts 48 3

Floor standing internal boilers flue components Components Part no. Description 125mm diameter 7 716 190 064 7 716 190 062 Standard telescopic flue kit (460-670mm) Short telescopic flue kit (360-460mm) 7 716 190 103 Vertical flue kit (1,080mm) 7 716 190 033 1,000mm extension (960mm) 7 716 190 097 600mm extension 7 716 190 034 90 flue bend Conventional flue 7 716 190 035 45 flue bend (pair) 7 716 190 105 7 716 190 101 Flue damper Infill plate kit (for high level horizontal flues) 7 716 191 090 Flashing flat roof 7 716 191 091 Flashing pitched roof Min. 7 716 190 050 Flue terminal guard 120mm 7 716 190 092 Plume management kit Min. 120mm 7 716 190 104 Conventional flue 80/100mm and 100/103mm adaptor kit* 7 716 190 065 130mm adaptor** * Must be used on 12/18 & 18/25 models when using third party conventional flue **Only required when using third party conventional flue on the 25/32 model and must be used with a conventional flue 80/100mm and 100/103mm adaptor kit (7 716 190 104) Min. 120mm Pitch roof Pitc roof T Min. 120mm 4

Greenstar Utility flue components suitable for 32/50 & 50/70 models Components Part no. Description 150mm diameter 7 716 190 043 Standard horizontal flue kit (880mm) 7 716 190 044 Vertical BF kit (1,290mm) 7 716 190 045 Flue extension (960mm) 7 716 190 046 90 flue bend 7 716 190 047 45 flue bend (pair) 7 716 190 051 Stainless steel flue terminal guard 7 716 191 101 Flat roof flashing 7 716 191 100 Pitched roof flashing Pitch roof Pitc roof Conventional flue Min. 7 716 190 049 Conventional 120mm flue adaptor kit Min. 120mm Floor standing external boilers flue components Min. 120mm Min. Components Part no. 120mm Description 125mm T diameter 7 716 190 034 Internal 90 flue bend (used inside boiler when fluing to side) 7 716 190 050 Flue terminal guard 5

Plume management Condensfit II plume management system Part numbers 80mm dia. plume management kit Comprises: 1 x terminal bend 1 x extension 500mm 1 x outlet assembly 1 x clamp pack 7 716 190 092 Accessories Components Part no. Description 80mm diameter 7 716 190 092 Plume management kit 7 716 190 093 1,000mm extension 7 716 190 095 90 bend 7 716 190 094 45 bend (pair) 8 718 687 007 Plume clamp For every 90º plume management kit bend deduct 1,000mm and 500mm for every 45º plume management kit bend. 6

Flexible flue system Oilfit flexible flue system for internal models only Components Part no. Description 100mm diameter 7 716 190 076 Oilfit flexi flue kit (8m)* 7 716 190 077 Oilfit flexi flue kit (12m)* 7 716 190 068 Telescopic extension 7 716 190 066 1,000mm extension kit 7 716 190 067 500mm extension kit 7 716 190 069 45º bend 7 716 190 074 Wall cover plate kit *Must be used with a conventional flue 80/100mm and 100/103mm adaptor kit (7 716 190 104) Pitched roof Pitc roof Components Part no. Min. Description 120mm Min. 130mm diameter 120mm 7 716 190 079 Oilfit flexi flue kit (8m) 7 716 190 080 Oilfit flexi flue kit (12m) 7 716 190 081 Oilfit flexi flue kit (15m) 7 716 190 072 Telescopic extension 7 716 190 070 1,000mm extension kit 7 716 190 071 500mm extension kit 7 716 190 073 45º bend Min. 120mm 7 716 190 075 Wall cover plate kit Min. 120mm Pitched roof Pitc roof Min. 120mm Min. 120mm 7

Flue terminal positioning 1. Where a flue is terminated less than 600mm away from a projection above it and the projection consists of plastics or has a combustible or painted surface, then a heat shield of at least 750mm wide should be fitted. 2. If the lowest part of the terminal is less than 2m above the ground, balcony, flat roof or other place to which any person has access, the terminal should be protected by a guard. 3. Notwithstanding the dimensions given above, a terminal should not be sited closer than 300mm to combustible material. In the case of a thatched roof, double this separation distance should be provided. It is also advisable to treat the thatch with a fire retardant material and close wire in the vicinity of the flue. 4. It is essential that a flue or chimney does not pass through the roof within the shaded area delineated by dimensions Q and R. 5. Where protection is provided for plastic components, such as guttering, it is essential that this is to the standard specified by the manufacturer of the plastic components. 8 Peel back page to reveal Flue Terminal Positioning Diagram

Key to illustration 1. 1,500mm vertically between terminals and the same wall. 2. 1,000mm below eaves, gutters, pipes and drains. External flue joints must be sealed with suitable silicon sealant. 3. 1,500mm measured horizontally between a vertical flue terminal and a window, dormer window or opening. 4. 1,200mm between terminals facing each other. 5. Vertical flue clearance, 300mm adjacent to a boundary line unless it will cause a nuisance. BS 5410: Part 1 2014 recommends that care is taken when siting terminal in relation to boundary lines. 6. 2,500mm to a boundary line, unless it will cause a nuisance. It is recommended that care is taken when siting terminal in relation to boundary lines. 7. 300mm minimum clearance from a non opening skylight to a vertical flue. 8. Vertical flue clearance, 750mm to non-combustible building material, and 1,500mm clearance to combustible building material. 9. 1,000mm above, below and either side of an opening door, air vent or opening window. These clearances are required by BS 5410 Part 1:2014 to reduce a possible pluming nuisance, this could be reduced to 600mm if there was no pluming nuisance, seek guidance from the local authority building control. 10. 600mm diagonally to an opening door, air vent or opening window. 11. 300mm to an internal or external corner. 12. 1,000mm below a Velux window for a vertical flue (1,000mm for horizontal flue terminal exhaust) 300mm above or to either side of the Velux window. The terminal must be at least 1,000mm from the Velux when measured horizontally. 13. The flue must extend at least 600 mm above the roof and 400mm horizontally from a pitched roof or 500mm in regions with heavy snow fall. 14. 1,500mm clearance to any vertical structure on a roof or room sealed flue that has a height difference of more than 300mm. Flue terminal positioning All measurements in millimetres 9 1000 1000 14 17 1 1000 1500 2 1500 600 300 17 3 2 750 * 1200 BOUNDARY LINE 1500 2000 13 1000 52 104 300 400 4 14 600 RIDGE FLUE 1000 300 1000 9 1000 1000 5 600 RIDGE VENT 14 4 1200 2500 6 1800 18 15 750 7 300 1500 750 1000 1000 9 8 15 1000 3 10 600 300 1500 11 300 12 300 15 3 13 400 600 1/2 1/2 19 14 1500 300 BOUNDARIES 300 300 1000 300 300 300 1000 16 300 300 19 17 12 300 12 2500 15. 1,000mm below eaves and gutters and sanitary pipe and 300mm from vertical sanitary pipes and drains. 16. Flue clearance must be at least 300mm from the ground. Terminal guards must be fitted if the flue is less than 2 metres from the ground or if a person could come into contact with the flue terminal. 17. 2,500mm to a surface facing a terminal, but must not be installed where it will cause a nuisance. 18. Terminals must be at least 1,800mm from an oil storage tank unless a wall with of at least 30 minutes fire resistance and extending 300mm wider and higher than the tank is between the tank and the terminal. 19. For the purpose of determining suitable flue terminal positions for the appliances, the boundary can be considered to extend to the centre line of any adjacent routes or waterways e.g. paths, streets, rights of way, canals, rivers or railways. * If there is more than 300mm height difference, then the distance between the vertical outlet should be 1,500mm. 9 10 11 12

Plume management Plume management kits are available for 125mm horizontally terminated flues. Please refer to the installation instructions supplied with the plume management kits. For more information on Worcester s plume management options, including reduced flue terminal clearances, please read the relevant boiler technical and specification brochure. 13

Floor standing condensing combi boilers Greenstar Heatslave II series Dimensions Width Height Depth Clearances Above Left Right Front 520mm 855mm 600mm 300mm* 5mm 5mm 600mm *Note: Although clearance above the Heatslave range is stated to be 300mm, a removable worktop may be placed directly above the boiler, allowing 10mm clearance. Models and outputs Boiler output (kw) Flow rate (l/min)* Part no. Greenstar Heatslave II 12/18 12 to 18 15 7 731 600 047 Greenstar Heatslave II 18/25 18 to 25 18 7 731 600 048 Greenstar Heatslave II 25/32 25 to 32 22 7 731 600 049 *Maximum flow rate to produce a 40 C temperature rise over a 90l draw off. Restricted DHW flow rate. DID YOU K N O W Each boiler that leaves our factory goes through more than 20 product tests. 14

Flue lengths Maximum flue lengths (mm) Diameter Direction 12/18 18/25 25/32 High level horizontal 5,000mm 5,000mm 5,000mm 125mm Rear exit horizontal 6,000mm 6,000mm 6,000mm Side exit horizontal 5,000mm 5,000mm 5,000mm Vertical 8,000mm 8,000mm* 8,000mm* 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. *Flue damper (7 716 190 101) required when vertical flue length exceeds 6m. For details of flue components see page 4. Model weights and efficiencies Weight lift ErP space heating efficiency class ErP water heating efficiency class SAP efficiency SAP comparative hot water efficiency Greenstar Heatslave II 12/18 124kg A / 91% B 89.4% 61.8 Greenstar Heatslave II 18/25 126kg A / 90% B 89.2% 61.6 Greenstar Heatslave II 25/32 128kg A / 91% B 89.0% 61.5 For details of compatible controls see page 35. See page 36 for relevant accessories. www Learn how to connect both Worcester and third party controls to a Heatslave II. Visit youtube.com/ WorcesterBoschGroup to see this and many other videos. 15

Floor standing condensing external combi boilers Greenstar Heatslave II External series Dimensions Width Height Depth Clearances Above RH/LH flue outlet on opposite side RH flue outlet on rear LH flue outlet on rear Rear = flue outlet on side Rear = rear flue outlet Front 640mm 950mm 770mm 600mm 10mm 85mm 10mm 150mm 2,500mm 600mm It is strongly recommended that the flue terminal faces away from walls to reduce the possibility of wetting occurring. Models and outputs Boiler output (kw) Flow rate (l/min)* Part no. Greenstar Heatslave II External 12/18 12 to 18 15 7 731 600 050 Greenstar Heatslave II External 18/25 18 to 25 18 7 731 600 051 Greenstar Heatslave II External 25/32 25 to 32 22 7 731 600 052 *Maximum flow rate to produce a 40 C temperature rise over a 90l draw off. Restricted DHW flow rate. DID YOU K N O W Our tech support team offers video calling on your smart device via Bosch Insight. 16

Flue lengths Maximum flue lengths (mm) Diameter External kit 12/18 18/25 25/32 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. Boiler comes with standard horizontal flue kit. A 90º bend is required when fluing to the side. For details of flue components see page 5. Model weights and efficiencies Weight lift ErP space heating efficiency class ErP water heating efficiency class SAP efficiency SAP comparative hot water efficiency Greenstar Heatslave II External 12/18 151kg A / 91% B 89.4% 61.8 Greenstar Heatslave II External 18/25 154kg A / 90% B 89.2% 61.6 Greenstar Heatslave II External 25/32 158kg A / 91% B 89.0% 61.5 For details of compatible controls see page 35. See page 36 for relevant accessories. www Download our MyWorcester install app for simple boiler registration, hints, tips and more. Visit worcester-bosch.co.uk/my 17

Floor standing condensing system boilers Greenstar Danesmoor System series Dimensions Width 370mm Height 855mm Depth 600mm Clearances Above (annual service) 10mm Above (maintenance & repair) 300mm Left 5mm Right 5mm Front 600mm The appliance is suitable for an under-worktop installation providing that the worktop above the boiler (min. 10mm clearance) is removable for maintenance and repair. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor System 12/18 12 to 18 7 731 600 062 Greenstar Danesmoor System 18/25 18 to 25 7 731 600 063 Greenstar Danesmoor System 25/32 25 to 32 7 731 600 064 DID YOU K N O W Sign up to Greenstar Rewards and collect points each time you install our award-winning products. 18

Flue lengths Maximum flue lengths (mm) Diameter Direction 12/18 18/25 25/32 High level horizontal 5,000mm 5,000mm 5,000mm 125mm Rear exit horizontal 6,000mm 6,000mm 6,000mm Side exit horizontal 5,000mm 5,000mm 5,000mm Vertical 8,000mm 8,000mm* 8,000mm* 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. *Flue damper (7 716 190 101) required when vertical flue length exceeds 6m. For details of flue components see page 4. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor System 12/18 111kg A / 91% 91.1% Greenstar Danesmoor System 18/25 112kg A / 90% 90.9% Greenstar Danesmoor System 25/32 121kg A / 91% 90.7% For details of compatible controls see page 35. See page 36 for relevant accessories. www Follow us on social media for all the latest news and views. 19

Floor standing condensing utility system boilers Greenstar Danesmoor System Utility series Dimensions Width 370mm Height 855mm Depth 600mm Clearances Above (annual service) 10mm Above (maintenance & repair) 300mm Left 5mm Right 5mm Front 600mm The appliance is suitable for an under-worktop installation providing that the worktop above the boiler (min. 10mm clearance) is removable for maintenance and repair. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor System Utility 12/18 12 to 18 7 731 600 065 Greenstar Danesmoor System Utility 18/25 18 to 25 7 731 600 066 Greenstar Danesmoor System Utility 25/32 25 to 32 7 731 600 067 DID YOU K N O W Working with Worcester, Bosch Commercial and Industrial offers outputs from 50kW to 38,000kW, as well as VRF and RAC offerings. 20

Flue lengths Maximum flue lengths (mm) Diameter Direction 12/18 18/25 25/32 High level horizontal 5,000mm 5,000mm 5,000mm 125mm Rear exit horizontal 6,000mm 6,000mm 6,000mm Side exit horizontal 5,000mm 5,000mm 5,000mm Vertical 8,000mm 8,000mm* 8,000mm* 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. *Flue damper (7 716 190 101) required when vertical flue length exceeds 6m. For details of flue components see page 4. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor System Utility 12/18 111kg A / 91% 91.1% Greenstar Danesmoor System Utility 18/25 112kg A / 90% 90.9% Greenstar Danesmoor System Utility 25/32 121kg A / 91% 90.7% See page 36 for relevant accessories. www For information on higher output boilers for small commercial projects, visit bosch-industrial.co.uk 21

Floor standing condensing external system boilers Greenstar Danesmoor System External series Dimensions Width 565mm Height 950mm Depth 780mm Clearances (Flue orientation from front) Right Left Rear Left 10mm 2,500mm* 85mm Right 2,500mm 10mm 45mm Rear 50mm** 50mm** 2,500mm* Above 600mm 600mm 600mm Front 600mm 600mm 600mm *From end of flue terminal allow 2,500mm clearance. **200mm if using a high level terminal exiting through the rear panel. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor System External 12/18 12 to 18 7 731 600 068 Greenstar Danesmoor System External 18/25 18 to 25 7 731 600 069 Greenstar Danesmoor System External 25/32 25 to 32 7 731 600 070 DID YOU K N O W Greenstar regular and system boilers can be installed in a cascade using the Low Loss Header accessory see page 37. 22

Flue lengths Maximum flue lengths (mm) Diameter External kit 12/18 18/25 25/32 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. For details of flue components see page 5. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor System External 12/18 119kg A / 91% 91.1% Greenstar Danesmoor System External 18/25 121kg A / 90% 90.9% Greenstar Danesmoor System External 25/32 131kg A / 91% 90.7% See page 36 for relevant accessories. www In partnership with local colleges we offer a range of training courses find your nearest here worcester-bosch.co.uk/colleges 23

Floor standing condensing regular boilers Greenstar Danesmoor regular series Dimensions Width 370mm Height 855mm Depth 600mm Clearances Above (annual service) 10mm Above (maintenance & repair) 300mm Left 5mm Right 5mm Front 600mm The appliance is suitable for an under-worktop installation providing that the worktop above the boiler (min. 10mm clearance) is removable for maintenance and repair. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor 12/18 12 to 18 7 731 600 053 Greenstar Danesmoor 18/25 18 to 25 7 731 600 054 Greenstar Danesmoor 25/32 25 to 32 7 731 600 055 DID YOU K N O W A dedicated spares team and a network of profile spares stockists across the UK means we offer 98% availability. 24

Flue lengths Maximum flue lengths (mm) Diameter Direction 12/18 18/25 25/32 High level horizontal 5,000mm 5,000mm 5,000mm 125mm Rear exit horizontal 6,000mm 6,000mm 6,000mm Side exit horizontal 5,000mm 5,000mm 5,000mm Vertical 8,000mm 8,000mm* 8,000mm* 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. *Flue damper (7 716 190 101) required when vertical flue length exceeds 6m. For details of flue components see page 4. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor 12/18 104kg A / 91% 91.1% Greenstar Danesmoor 18/25 108kg A / 90% 90.9% Greenstar Danesmoor 25/32 114kg A / 91% 90.7% For details of compatible controls see page 35. See page 36 for relevant accessories. www Keep updated with product installation news and tips by subscribing to our Technical Bulletins at worcester-bosch.co.uk/tb 25

Floor standing condensing regular utility boilers Greenstar Danesmoor Utility regular series Dimensions Width 370mm Height 855mm Depth 600mm Clearances Above (annual service) 10mm Above (maintenance & repair) 300mm Left 5mm Right 5mm Front 600mm The appliance is suitable for an under-worktop installation providing that the worktop above the boiler (min. 10mm clearance) is removable for maintenance and repair. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor Utility 12/18 12 to 18 7 731 600 056 Greenstar Danesmoor Utility 18/25 18 to 25 7 731 600 057 Greenstar Danesmoor Utility 25/32 25 to 32 7 731 600 058 DID YOU K N O W Our oil-fired boiler training courses are extensive. Visit worcester-bosch.co.uk/training or call 0330 123 0166 to find out more. 26

Flue lengths Maximum flue lengths (mm) Diameter Direction 12/18 18/25 25/32 High level horizontal 5,000mm 5,000mm 5,000mm 125mm Rear exit horizontal 6,000mm 6,000mm 6,000mm Side exit horizontal 5,000mm 5,000mm 5,000mm Vertical 8,000mm 8,000mm 8,000mm* 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. *Flue damper (7 716 190 101) required when vertical flue length exceeds 6m. For details of flue components see page 4. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor Utility 12/18 104kg A / 91% 91.1% Greenstar Danesmoor Utility 18/25 108kg A / 90% 90.9% Greenstar Danesmoor Utility 25/32 108kg A / 91% 90.7% See page 36 for relevant accessories. www When you install Worcester products in your own home, you can claim cash-back! Go to worcesterpromotions.co.uk for details. 27

Floor standing condensing external regular boilers Greenstar Danesmoor External regular series Dimensions Width 565mm Height 950mm Depth 780mm Clearances (Flue orientation from front) Right Left Rear Left 10mm 2,500mm* 85mm Right 2,500mm 10mm 45mm Rear 50mm** 50mm** 2,500mm* Above 600mm 600mm 600mm Front 600mm 600mm 600mm *From end of flue terminal allow 2,500mm clearance. **200mm if using a high level terminal exiting through the rear panel. Models and outputs Boiler output (kw) Part no. Greenstar Danesmoor External 12/18 12 to 18 7 731 600 059 Greenstar Danesmoor External 18/25 18 to 25 7 731 600 060 Greenstar Danesmoor External 25/32 25 to 32 7 731 600 061 DID YOU K N O W Each boiler that leaves our factory goes through more than 20 product tests. 28

Flue lengths Maximum flue lengths (mm) Diameter External kit 12/18 18/25 25/32 80mm Plume management 5,000mm 5,000mm 4,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend. For details of flue components see page 5. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Danesmoor External 12/18 99kg A / 91% 91.1% Greenstar Danesmoor External 18/25 102kg A / 90% 90.9% Greenstar Danesmoor External 25/32 106kg A / 91% 90.7% See page 36 for relevant accessories. www Come and watch Greenstar gas-fired boilers being manufactured. Book your factory tour here worcester-bosch.co.uk/factory 29

Floor standing condensing regular utility boilers Greenstar Utility regular series Dimensions Width Height Depth Clearances Above Left Right Front 520mm 1,012mm 815mm 300mm* 10mm 10mm 600mm *Note: Although clearance above the Greenstar Utility range is stated to be 300mm, a removable worktop may be placed directly above the boiler, allowing 10mm clearance. Models and outputs Boiler output (kw) Part no. Greenstar Utility 32/50 32 to 50 7 731 600 073 Greenstar Utility 50/70 50 to 70 7 731 600 074 DID YOU K N O W Our Greenstar System Filter is available in 22mm and 28mm variants. 30

Flue lengths Maximum flue lengths (mm) Diameter Direction 32/50 50/70 High level horizontal 2,000mm 2,000mm 150mm Rear exit horizontal 3,000mm 3,000mm Side exit horizontal 3,000mm 3,000mm Vertical 6,000mm 6,000mm Note: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend. For details of flue components see page 5. Model weights and efficiencies Weight lift ErP space heating efficiency class SAP efficiency Greenstar Utility 32/50 271kg B / 89% 90.7% Greenstar Utility 50/70 281kg B / 89% 90.5% See page 36 for relevant accessories. 31

Controls To find out which Greenstar boilers are compatible with our range of optional plug-in controls, see page 35. Greenstar Comfort controls Greenstar Comfort plug-in twin channel programmer (for use with internal and external models) Part no. 7 733 600 003 Simple menu navigation Heating programme visualisation bar 7-day time control for heating and hot water. EFFICIENCY +1% Greenstar Comfort I RF wireless room thermostat and plug-in twin channel programmer (for use with internal models) Part no. 7 733 600 001 All the features of Comfort PLUS Enhanced load compensation for increased efficiency. Quick installation no wiring required Extremely reliable RF signal. DID YOU K N O W Any Worcester control purchased with a Greenstar oil boiler will acquire the same guarantee as the boiler. 32

EFFICIENCY +1% Greenstar Comfort II RF wireless programmable room thermostat and plug-in RF receiver (for use with internal models) Part no. 7 733 600 002 All the features of Comfort & Comfort I PLUS 6 adjustable heating temperatures per day Set programme at the room thermostat Remote access to boiler diagnostic codes Optional wall plate available, 7 733 600 039. Comfort Wall Plate Kit Part no. 7 733 600 039 Allows remote mounting of a Comfort plug-in unit which is then wired to the boiler. Ideal for use with external boilers. The Greenstar Comfort I RF and Greenstar Comfort II RF can be used with external boilers if they are hard wired and used with the Comfort Wall Plate Kit. 33

Digital plug-in 7 day twin channel programmer Part no. 7 716 192 033 Plugs into the boiler fascia panel and offers 3 separate time periods for both heating and hot water. Intelligent weather and load compensation controls EFFICIENCY +1.5% Outdoor weather sensor (for use with internal and external models) Part no. 7 716 192 764 Monitors external temperatures to offer weather compensation in combination with the in-built heat curves of the Greenstar Heatslave II. For use with 230V controls. Not compatible with Worcester Comfort controls. To be used with a 230V programmer and room thermostat. 34

Controls compatibility Control Part no. Greenstar Heatslave II Comfort 7 733 600 003 Comfort I RF 7 733 600 001 Comfort II RF 7 733 600 002 Outdoor weather sensor* 7 716 192 764 Greenstar Heatslave II External Comfort 7 733 600 003 Comfort I RF 7 733 600 001 Outdoor weather sensor* 7 716 192 764 Greenstar Danesmoor Digital plug-in 7 day twin channel programmer 7 716 192 033 *Not compatible with Comfort controls. Use with Comfort Wall Plate Kit 7 733 600 039. 35

Accessories Worcester CondenseSure (Suitable for internal oil boilers only) Part no. 7 716 192 746 No electrical supply needed Zero running costs and no wiring connection, so no need for an electrician to install. Compatible with all boilers Can be installed on new or existing installations and is suitable for any gas- or oil-fired condensing boilers. Uses free energy By attaching the CondenseSure to the 22mm heating flow pipework the energy from the pipe is used to heat the condensate. Installation flexibility Can be installed under the boiler or remotely. 36

Greenstar System Filter Part no. 7 733 600 236 (22mm), 7 733 600 237 (28mm) Over-tightening prevention feature The removable lid has been designed to prevent overtightening and damage to the O-ring seal, eliminating the risk of leaks. Isolation valve indicators The isolation valves can be opened using a single 90º turn, with red and green indicators showing when the filter is in operation. Bi-directional flow Engineered to allow a bi-directional flow, enabling it to be installed anywhere along the return circulation pipework between the last radiator and the boiler. System Filters should be installed internally within the property and not within the boiler cabinet. Greenstar Low Loss Header (Suitable for Utility and Danesmoor internal boilers only) Part no. 7 716 192 614 Ready-made solution for the connection of two Greenstar system or regular boilers on a sealed heating system with a combined output of up to 70kW. 37

Greenstore unvented cylinder series Compliant with Building Regulation G3 Manufactured within the Bosch Group. Stainless steel cylinder (providing a 25 year guarantee*) Unvented, providing mains pressure hot water For use with Worcester system and regular boilers Comprehensive accessory and fittings pack WRAS and WRC-NSF approved 65mm of factory-fitted insulation producing low stand-by heat loss Multiple sensor/thermostat pockets allowing flexible and easy system integration with control solutions. 38 *Terms and conditions apply.

Dimensions and dry weights Diameter (mm) Height (mm) Weight dry (kg) Part no. Greenstore SC-90 Cylinder 570 835 26 7 716 842 027 Greenstore SC-120 Cylinder 570 1,035 31 7 716 842 028 Greenstore SC-150 Cylinder 570 1,285 36 7 716 842 029 Greenstore SC-180 Cylinder 570 1,490 40 7 716 842 030 Greenstore SC-210 Cylinder 570 1,665 44 7 716 842 031 Greenstore SC-250 Cylinder 570 1,860 48 7 716 842 032 Greenstore SC-300 Cylinder 570 2,155 54 7 716 842 033 Volumes and efficiencies Volume domestic hot water (litres) Greenstore SC-90 Cylinder Standing heat loss 24hr (kwh/24hrs) ErP energy efficiency class/ standing heat loss (W) 93 1.008 B / 42 Greenstore SC-120 Cylinder 123 1.296 C / 54 Greenstore SC-150 Cylinder 161 1.632 C / 68 Greenstore SC-180 Cylinder 191 1.824 C / 76 Greenstore SC-210 Cylinder 216 1.944 C / 81 Greenstore SC-250 Cylinder 246 2.136 C / 89 Greenstore SC-300 Cylinder 292 2.304 C / 96 39

Greenstore solar compatible unvented cylinder series Compliant with Building Regulation G3 Manufactured within the Bosch Group. Stainless steel cylinder (providing a 25 year guarantee*) Unvented, providing mains pressure hot water Twin-coil for use with two fossil fuel appliances or one fossil fuel appliance and one solar installation Comprehensive accessory and fittings pack WRAS and WRC-NSF approved 65mm of factory-fitted insulation producing low stand-by heat loss Multiple sensor/thermostat pockets allowing flexible and easy system integration with control solutions Dedicated solar volume in accordance with MCS scheme. 40 *Terms and conditions apply.

Dimensions and dry weights Diameter (mm) Height (mm) Weight dry (kg) Part no. Greenstore TC-150 Cylinder 570 1,285 41 7 716 842 040 Greenstore TC-180 Cylinder 570 1,490 45 7 716 842 041 Greenstore TC-210 Cylinder 570 1,665 50 7 716 842 042 Greenstore TC-250 Cylinder 570 1,860 54 7 716 842 043 Greenstore TC-300 Cylinder 570 2,155 60 7 716 842 044 Volumes and efficiencies Volume domestic hot water (litres) Dedicated solar volume (litres) Greenstore TC-150 Cylinder Standing heat loss performance (kwh/24hrs) ErP energy efficiency class/standing heat loss (W) 157 65 1.632 C / 68 Greenstore TC-180 Cylinder 187 65 1.824 C / 76 Greenstore TC-210 Cylinder 211 105 1.944 C / 81 Greenstore TC-250 Cylinder 241 115 2.136 C / 89 Greenstore TC-300 Cylinder 287 115 2.304 C / 96 41

Extended guarantees OIL-FIRED BOILER RANGE 2 year guarantee* comes as standard on: Any Greenstar oil-fired boiler. The Greenstar System Filter The Greenstar System Filter available in 22mm and 28mm versions delivers powerful system protection and is the key to an increased guarantee. For a 5 year guarantee*, install: Any Greenstar oil-fired boiler Greenstar System Filter. 42 For more details visit our website at worcester-bosch.co.uk

GAS-FIRED BOILER RANGE 5 year guarantee* comes as standard on: Any Greenstar gas-fired boiler. For a 6 year guarantee*, install: Any Greenstar i, Si or Ri gas-fired boiler Greenstar System Filter. For a 7 year guarantee*, install: Greenstar CDi gas-fired boiler Greenstar System Filter. *Terms and conditions apply. 43

Bosch Commercial and Industrial Offering a broad portfolio that covers all heating and cooling requirements Expand your business with Bosch Commercial and Industrial The products and support services you can access gives you the chance to expand your business offering and provide installations for: Large domestic properties Hotels, guest houses and holiday parks Sports and leisure centres Education and healthcare facilities Mini district heating schemes And many more. Heating and hot water solutions Gas- or oil-fired boilers with individual outputs from 50kW to 38,000kW and standard efficiencies of up to 109%. Compact condensing multi-boiler cascade systems of wall-mounted boilers (400kW in just 1m²). Compact condensing multi-water heater cascade systems of wall-mounted water heaters (up to 600kW) Heat Interface Units with hot water flow rates of 14 l/min and 21/l/min Combined heat and power (CHP) modules with outputs ranging from 12kWe to 2MWe. 44

Air conditioning solutions Air conditioning solutions with a comprehensive Variable Refrigeration Flow (VRF) range. Bosch Climate RAC Split range. All VRF products are compatible with a complete range of intelligent controls and accessories. For more information please call 0330 123 3004 or visit bosch-industrial.co.uk Bosch Commercial and Industrial UK @BoschHeating_UK 45

Industry training courses For more details on classroom, industry and online courses visit our website at worcester-bosch.co.uk/training or call 0330 123 0166. Industry focused courses Hot water systems and safety Chemical water treatment WRAS water regulations Domestic ACS LPG changeover 46

Product training courses Oil boiler courses Advanced Oil Fault Finding Training Course www Greenstar Oil Training Course Gas boiler courses Gas Overview Training Course www www Greenstar CDi & Si Compact Training Course Greenstar CDi Classic Combi Training Course Greenstar Floor standing Gas Combi Training Course Greenstar Gas System & Regular Training Course www Greenstar i Combi Training Course Greenstar i Junior Training Course Worcester Controls Training Course Solar thermal courses Greenskies Solar Hot Water System Training Course Heat pump courses Greensource Air to Air Heat Pump Training Course www Greenstore LECP Ground Source Heat Pump Training Course Introduction to Heat Pumps Training Course Commercial courses www GB162 Training Course Greenspring CWi47 Continuous Flow Water Heater Training Course Heat Interface Unit (HIU) Training Course www Product has online training course available. 47

Useful contacts Worcester Service Enquiries Tel: 0330 123 9559 Email: service.mailbox@uk.bosch.com Sales Tel: 0330 123 9669 Spare Parts Tel: 0330 123 9779 Technical Helpline (Pre & Post Sales) Tel: 0330 123 3366 Email: technical-advice@uk.bosch.com Controls Helpline Tel: 0330 123 3641 Training Tel: 0330 123 0166 Literature Email: brochure-request@uk.bosch.com or download instantly from our website or telephone 0330 123 9119. Follow us! Send us pictures of your installations and stay up to date with the latest news, views and installation tips. @WorcesterBosch Worcester Bosch Professional @WorcesterBoschProfessional Worcester Bosch Worcester Bosch Group Calls to and from Bosch Thermotechnology Ltd may be recorded for training and quality assurance purposes. Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. This brochure is accurate at the date of printing, but may be superseded and should be disregarded if specification and/or appearances are changed in the interest of continued improvement. The statutory rights of the consumer are not affected. Worcester, Bosch Group, Cotswold Way, Warndon, Worcester, WR4 9SW Part No. 8 716 116 678 0 Issue H 01/18