Part#: 26B113 HEAVY DUTY CAST IRON ROTARY DRUM PUMP

Similar documents
Teflon Rotary Drum Pump

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

7165 Dust Collector Owner s Manual

5HP CYCLONE DUST COLLECTOR MANUAL

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

Flammable and Combustible Liquids

569, 570, 571, 572 Series

568X, 587X, 588X Series

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

569, 570, 571, 572 Series

IMPORTANT SAFETY RULES

OPERATING INSTRUCTIONS DUST EXTRACTOR FM300S

Action Electric Drum Pumps

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

55-Gallon Dispenser Package

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver

SuperKlean Washdown Products

Installation / Assembly

55-Gallon Dispenser Package

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

1350 & AMMCO Brake Washer Systems. Installation and Operating Instructions With Safety and Maintenance Instructions and Parts Identification

! WARNING. Before using product, read and understand instructions.

918 Clock Gauge Installation, Operation, and Maintenance Instructions

hp Dust Collector With Vacuum Attachment

! WARNING. Before using product, read and understand instructions.

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

Table Top Patio Heater

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

Mighty Venter Power Vent System

! WARNING. Before using product, read and understand instructions.

OWNER S OPERATING MANUAL DC-1200P DUST COLLECTOR

Element 14.7 Fire Prevention and Control 2018

STAINLESS STEEL UNITS

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

PORTABLE KEROSENE HEATER OPERATION AND MAINTENANCE INSTRUCTIONS. Model RCA-2800

Stillwater Area Community Services Center Inc.

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

Corn Flame Energy Corn Stove Model 3000

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

SPECIFICATIONS PART NAME

AeroVent 1 Product Manual

Fire Prevention Plan

LC Series - Light Commercial Pump Station Installation and Operation Manual

Models: GW/R-T GW/R-2-T GW/R-3-T

Installation Instructions Remote Blowers

Fire Prevention Plan

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Acrylic Claw Foot Tub

PRO 2000i LOW LEVEL DEPOSITOR

Assembly & User Instructions Mirage 38,200Btu Heat Focusing Patio Heater

Automatic Dryers. Installation. Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.

Oscillating Belt/Spindle Sander 230V

User s Information Manual

Page 1 of 18. Part# /5/2013

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

These instructions are for your safety. Please read them thoroughly before use and retain them for future reference

Models Series Series

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

CORALAIS BODYSPA BATH AND SHOWER FAUCET

CONSTANT SUCTION UNIT

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

Code UB-3300VECK Cyclone Extractor

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Model K 3000 G Part No

AeroVent 3X Product Manual

Thermal Stability Systems

AeroVent Standard Product Manual

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Flammable Liquids!!!!!

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

HI Industrial Utility Heater HI Soleus Air International

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

Pizza Oven with Stand

HydroFlux Welder Torch System T0-102 / T0-103

INSTRUCTION MANUAL PRODUCT VIEW

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Patio Heater Model No. GM and GM

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Please Read and Save These Instructions.

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

Panel Fan Series Operators Manual (Galvanized and Polymer)

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

Model HD 3501 Part No High Pressure Washer Operator Manual

Transcription:

Part#: 26B113 Part # 26B113 Description HEAVY DUTY CAST IRON ROTARY DRUM PUMP

Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Cast Iron Rotary Drum Pump 5 Description Cast iron rotary drum pump can dispense oils, antifreeze, transmission fluid, etc. Not for use with water. This self priming drum pump is used for pumping applications on farms, construction sites, manufacturing plants Specifications Flow Rate...10GPM Inlet...1 1/4"OD Outlet...1"OD Bung Adapter...2"NPT Suction Tube... 40 1/4" Steel Packing Gland...Viton Wetted Parts...Cast iron, Steel & Viton Maximum Centipoise...1000 CPS Maximum Discharge Head...3' (1 PSI) Maximum Temperature...140 F General Safety Information It is the responsibility of the user to operate the pump in conformance with OSHA rules for dispensing liquids. Pump containers should be grounded when using with flammable liquids to avoid static electricity. Pump should be washed out before usage since processing lubricants could contaminate the fluids. 1. When using a hand pump (especially when pumping flammable, combustible or hazardous liquids) follow all electrical and safety codes, as well as the United States Occupational Safety and Health Act (OSHA), most recent National Electrical Code (NEC), National Fire Protection, Inc. * (NFPA) Code 30 (Flammable and Combustible Code), NFPA 56A (Standard for use of Inhalation Anesthetics), NFPA 77 (Static Electricity), NFPA 78 (Lightning Protection Code), NFPA 80 (Standard for Fire Doors and Windows), NFPA 251 (Standard Method of fire Test of Building Construction), NFPA 704 (Identification of the Fire Hazards of Materials), other NFPA codes, local codes and ordinances, as needed in a particular application 2. Know the pump application, limitations, and potential hazards. The "" statements indicate potential hazardous conditions for the operator or equipment. TAKE NECESSARY STEPS TO PROTECT PERSONNEL AND EQUIPMENT. NOTE: Pump should only be used with liquids compatible with pump component materials. Consult PUMP CHEMICAL COMPATIBILITY CHART and PUMP SPECIFICATIONS. Also, the chemical supplier should be consulted regarding any questions of chemical compatibility, proper and safe use and handling of chemical. Misapplication of pump or use of noncompatible liquids will void warranty. In order to properly use this product, familiarize yourself with this pump and also with the liquid (chemical, etc.) that is going to be pumped through the unit. Although this pump is suited for many liquids, it is NOT suitable for all liquids! (*) Any of the NFPA Codes can be obtained from : National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 0269, telephone 1-800-344-3555. Write or call for listing and prices. 3. Pumping hazardous, flammable, or combustible liquids should only be done in buildings, rooms, or areas suited for this purpose. (See NFPA 30, NFPA 78, NFPA 80, NFPA 251, NFPA 704, other suitable NFPA codes, OSHA, insurance companies, local codes and ordinances.) 1

Operating Instructions and Parts Manual Cast Iron Rotary Drum Pump General Safety Information (Continued) When filling cans, drums, etc. with combustible or flammable liquids, both container pumping from and container pumping to, should be bonded and grounded to dissipate possible accumulations of static electricity, and minimize sparks caused by static electricity (refer to NFPA 77 for specific details). Removal of outer garments in work areas where there may be flammable or explosive liquids, which are ignitable with low electrical energy, can be fatal and/or cause property damage (refer to NFPA 56A, and NFPA 77, for further details). 4 The "" and instructions for gasoline below pertain not only to gasoline, but to any flammable, combustible or hazardous fluid. Gasoline is a highly flammable fuel. The improper use, handling or storage of gasoline can be dangerous. Prevent accidents by following these safety rules: a. Use gasoline only as a fuel, never as a cleaning fluid. b. Use only an approved container to hold or store gasoline. Never store gasoline in familiar containers such as milk containers or soda pop bottles. c. Store gasoline in a cool location, out of the reach of children. Never store gasoline near heat or an open flame. d. Provide a fire extinguisher nearby when working with gasoline. Be sure extinguisher is in operating condition - check the pressure gauge or indicator. Be familiar with its proper use. Consult local fire department for the correct type of extinguisher for your application. Extinguishers rated ABC by the National Fire Protection Association are appropriate for most applications. e. Provide positive shut-off valves on all permanent fuel supplies. Fuel lines must be of steel piping, adequately secured, and free from leaks. f. Provide adequate ventilation, and clean up any spills when handling or pumping flammable liquids. g. POSITIVELY NO SMOKING! 5. Do not use torches or apply fire or flame to this pump for any reason. 6. Secure the discharge line before starting the pump. An unsecured discharge line will slip, possibly causing personal injury and/or property damage. 7. Do not over tighten nonmetallic threaded fittings. One full turn past hand tight is usually enough to prevent leakage. Teflon sealant tape should be used on all threaded joints, including the spout. 8. Check hoses for weak or worn condition before each use, making certain that all connections are secure. 9. Periodically inspect pump and system components. Perform routine maintenance as required. 10. Drain all liquids from the system before servicing. Any pump used to transfer flammable liquids must be stored in a well ventilated area after use. 11.Personal Safety a. Wear safety glasses at all times when working with pump. b. Wear a face shield, proper apparel and suitable respiratory equipment, when pumping hazardous chemicals. c. Keep work area clean, uncluttered, and properly lighted, replace all unused tools and equipment. d. Keep visitors at a safe distance from the work area. e. Make workshop childproof, with padlocks, master switches, and by removing starter keys. Failure to follow all general safety information can result in a fatality, personal injury and/or property damage! Assembly & Installation 1. Screw bung adapter (Ref. No. 14) into drum with threaded end down. 2. Screw spout (Ref. No.1) into casing (Ref. No. 3). Use Teflon sealant tape provided. Do not over tighten. 3. Screw suction tube (Ref. No. 22) into tail pipe (Ref. No. 20) and suction tube (Ref. No. 21). Use Teflon sealant tape provided. 4. Screw suction tube assembly into casing (Ref. No. 3). Use Teflon sealant tape provided. Do not overtighten. 5. Insert handle shaft (Ref. No. 17) through handle (Ref. No. 12). Thread hex nut (Ref. No. 18) onto handle shaft until handle rotates freely. 6. Screw handle assembly into crank arm (Ref. No. 11). Prevent handle shaft from turning, then tighten hex nut against crank arm. Insert crank arm assembly onto motor shaft and tighten in the rotor shaft. 7. Insert pump assembly into drum through the bung adapter and tighten the thumb screw (Ref. No. 15) by hand. Do not use a wrench or tool to tighten the thumb screw. 2

Operating Instructions and Parts Manual Cast Iron Rotary Drum Pump Operation 1. Rotate handle clockwise several times. If unit does not pick up prime in a few turns, pour some fluid into pump discharge to aid priming 2. For siphoning, set handle straight down. 3. To stop siphoning, rotate handle 1/4 turn. 4. After using pump, set handle straight down. Liquid will drain back to container. 5. If pump is removed from drum, rinse thoroughly in liquid that is compatible with both the pump and fluid. For questions about chemical compatibility contact your chemical supplier. Maintenance IMPORTANT: Periodically inspect the pump assembly and suction tubes for weak or worn condition. Make certain that all connections and fasteners are tight and secure. Perform routine maintenance as required. 90-Day Limited Warranty 3

Action Operating Instructions and Parts Manual 10 1 11 16 3 2 12 18 16 17 4 14 10 9 8 15 22 21 20 5 Replacement Parts List Reference Part Number Description Number Quantity 1 Discharge spout -01 1 2 Rear Cover -02 1 3 Casing -03 1 4 Rotor assembly -04 1 5 Vane kit (2 Vanes, 1 spring, 1rod) -RK 1 8 Lip Seal -08 1 9 Front Cover -09 1 10 5/16-18 x 1" Cap Screw -10 4 11 Crank Arm -11 1 12 Handle -12 1 14 Bung Adapter -14 1 15 Thumb screw -15 1 16 5/16-18 x 3/4" Cap Screw -16 7 17 Handle shaft -17 1 18 3/8-16" Hex nut -18 1 20 Tail Pipe -13 1 21 Suction Tube -22 1 22 Suction Tube - 1 5/16" Flat Washer -21 10 4