Use. Functions. Key function. Other functions

Similar documents
RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL470. Heating Controller. Use. Functions. Series B

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVP310. Heating Controller. Building Technologies HVAC Products

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

G a

RVL480. Heating Controller

RVL481. Heating Controller. including d.h.w. heating

RVL479. Heating Controller. for use with a partner unit

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

PRELIMINARY EDITION

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

Heating and D.h.w. Controller RVL482 Basic Documentation

District heating controller

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

RVL47. Heating Controller. Installations Instructions. Installation

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

District heating controller

Self-learning Room Temperature Controller

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Self-learning Room Temperature Controller

District Heating Controller

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Self-learning Room Temperature Controller

QAW70. Room Unit. Building Technologies. for use with heating controllers

REA22 Room Temperature Controller

Room Temperature Controller

Room Temperature Controller

Immersion Temperature Controller

Heating Controller. Building Technologies HVAC Products. Synco 700

RVA Cascade Controller for modulating gas-fired Boilers Basic Documentation

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Operating Instructions

RVA Heating Circuit or Primary Controller Basic Documentation. Siemens Building Technologies Landis & Staefa Division

Room Temperature Controller

Room Temperature Controllers

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

for relative humidity and temperature

Self-learning Room Temperature Controller

Room Unit. Building Technologies SYNERGYR

Heating controller with optimisation functions

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Boiler Sequence Controller

UV Flame Supervision System

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room Temperature Controller with LCD

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Heating Controller. Synco 700

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

ECL Comfort 110, application 116

Self-learning Room Temperature Controller

Weather compensated flow temperature control of heating and boiler systems

LAE10 LFE10. Use. Series 02

Control solutions Biofloor

Semi flush-mount room thermostats

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

ECL Comfort 110, application 130

Duct Temperature Sensors

for relative humidity and temperature

Local Process Bus LPB

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Central apartment unit

Room thermostat with 24-hour time switch and large LCD

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

BLC1.A Boiler Load Compensator

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Infrared Flame Detectors

Duct Temperature Sensors

Preliminary Release. Room Temperature

for relative humidity and temperature with calibration certificates

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Operating Instructions

for central air handling with single- or two-speed fans

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Frost Protection Thermostat

ECL Comfort V a.c. and 24 V a.c.

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Digital Room Thermostat for Heating Applications with 7-Day Time Program

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

INSTRUCTION FOR THE USER THC V E OIL BLU

prestige Control Application Supplement WARNING

Modulating clock thermostat

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Transcription:

2 466 Heating Control System RVP102/SET Heating control system for use in smaller plants. Control of boiler temperature through direct burner control, pump control, weather-compensated setpoint (with or without room temperature influence), or room temperature compensation. Analog setting elements, operating voltage AC 230 V, in conformance with CE directives. Use Types of houses: Single family houses and holiday houses Types of plant: Heating zones with direct burner control Types of heating systems: Radiator, convector and underfloor heating systems Functions Key function Other functions Operating modes Key function is the control of the boiler temperature by a single-stage burner. The following modes of control are available: Weather-compensated Weather-compensated with room temperature influence Room temperature-compensated Pump control Room temperature-dependent quick setback and boost heating Automatic heating limit switch for demand-dependent switching of the heating system, based on the outside temperature Frost protection, ensured in all operating modes The required operating mode is selected on the room unit QAW70 (not possible on the controller). Automatic operation Automatic changeover between normal and reduced temperature according to the 24-hour or weekly program, with ECO automatic energy saver Manual changeover between normal temperature (no ECO automatic energy saver) and reduced temperature (with ECO) by means of presence button Standby Siemens Building Technologies CE2N2466E / 18.12.1998 Landis & Staefa Division 1/8

Room unit QAW70 with room detector, time switch, setpoint adjustment, presence button, and setting knob for room temperature readjustment Ordering When ordering the complete heating control system, please give type reference RVP102/SET. This set will be comprised of the following units: Heating controller RVP102 Room unit QAW70 Outside detector QAC32 Clamp-on temperature detector QAD22 Equipment combinations Suitable detectors and room units: Flow temperature: all detectors with sensing element LG Ni 1000 Ω at 0 C (contained in the set: QAD22) Room temperature: digital room unit QAW70 (part of the set) Outside temperature (the controller identifies the type of detector used): outside detector QAC32 (part of the set) outside detector QAC22 Technical design Compensating variables Weather-compensated: the setpoint of the boiler temperature is continuously shifted in function of the outside temperature (outside detector). Assignment of the flow temperature to the actual outside temperature is made via the heating curve. Its slope is adjustable. Room temperature authority = 0 % Weather-compensated with room temperature influence: the setpoint of the boiler temperature is shifted in function of the outside temperature (outside detector) and, in addition, in function of the setpoint / actual value deviation of the room temperature. Room temperature authority = 1 99 % (adjustable, guide value is 50 %) Room temperature-compensated: the setpoint of the boiler temperature is shifted in function of the setpoint / actual value deviation of the room temperature. Room temperature authority = 100 % The compensating variable used for weather compensation is the composite outside temperature. It is generated from the actual and the attenuated outside temperature. The attenuated outside temperature is calculated. It is strongly attenuated and delayed when compared with the actual outside temperature. With weather-compensated control, the compensating variable can be changed in function of the operational level, independent of the selected room temperature authority: Without changeover: weather-compensated control with or without room temperature influence when heating to the normal and to the reduced temperature With changeover: weather-compensated control with or without room temperature influence when heating to the normal temperature, and room temperature compensated control when heating to the reduced temperature In addition, the RVP102 allows the base point (tilting point) of the heating curve to be changed: Base point at 20 C flow temperature: suitable for radiators and underfloor or ceiling heating systems Base point at 35 C flow temperature: suitable for convectors CE2N2466E / 18.12.1998 Siemens Building Technologies 2/8 Landis & Staefa Division

Heating curve chart T V35 115 105 95 T V20 110 100 90 80 4 3,5 3 2,75 2,5 2,25 2466D01 2 1,75 1,5 85 70 1,25 75 60 1 65 50 0,75 55 45 35 40 30 20 20 10 0-10 -20-30 0,5 0,25 T A T A T V20 T V35 Outside temperature [ C] Flow temperature with a base point at 20 C Flow temperature with a base point at 35 C Boiler temperature control Frost protection for the boiler Frost protection for the plant Frost protection for the building Pump control Boost heating The boiler temperature is controlled via a single-stage burner which is switched depending on demand. The burner's minimum on time is two minutes. The switching differential is adjustable in the range 1 20 K (factory-setting 6 K). The boiler will be shut down: After quick setback When there is no demand for heat This means that it will not be necessary to maintain a minimum boiler temperature. If the boiler temperature falls below 5 C, the burner will be switched on. After it has risen above this level by the amount of the switching differential, the burner will be switched off again. Frost protection for the plant protects the heating plant against freeze-ups by activating the circulating pump. It can be provided with or without an outside detector: With outside detector: Outside temperature 1.5 C: the circulating pump will be switched on for 10 minutes at 6-hour intervals Outside temperature 10 C: the circulating pump will run continuously Without outside detector: Flow temperature 10 C: the circulating pump will be switched on for 10 minutes at 6-hour intervals Flow temperature 5 C: the circulating pump will run continuously Frost protection for the plant can be deactivated, if required. Frost protection for the building acts as minimum room temperature limitation and protects the rooms from too low temperatures. It can be achieved with or without room unit, provided the heating curve slope is correctly set. Without room unit: Attenuated outside temperature 5 C: the control is switched on and the flow temperature is controlled such that a room temperature of 5 C will be maintained Attenuated outside temperature >6 C: the control is switched off With room unit and with quick setback active: Room temperature 5 C: the control is switched on and the flow temperature is controlled such that a room temperature of 5 C will be maintained Room temperature >6 C: the control is switched off With room unit, but without quick setback: Same as without room unit can be deactivated, if required. Frost protection for the building can be deactivated, if required. Control functions of the circulating pump: Pump overrun of six minutes (function can be deactivated) Pump kick; the circulating pump is switched on for one minute at 36-hour intervals When changing from the reduced temperature to the normal temperature, the controller will initiate boost heating, in which case the room temperature setpoint is raised by 5 K. Siemens Building Technologies CE2N2466E / 18.12.1998 Landis & Staefa Division 3/8

When the room temperature reaches a level which lies 0.25 K below the setpoint of the normal temperature, boost heating will be switched off. Boost heating necessitates a room unit. This function can be deactivated if required. Quick setback ECO automatic energy saver ECO function 1 ECO function 2 Room temperature influence Remote operation When changing from the normal temperature to the reduced temperature or standby mode, the heating will be shut down until the respective room temperature setpoint is reached. Quick setback necessitates a room unit. This function can be deactivated if required. The ECO automatic energy saver switches the heating off if permitted by outside temperature conditions while considering the outside temperature and an adjustable heating limit. In the RVP102, the ECO automatic energy saver is subdivided into two part functions. ECO function 1 is primarily active during the summer months while ECO function 2 is mainly used during the intermediate seasons and responds to short-time temperature variations. The thermal inertia of the house is taken into consideration by making use of the attenuated outside temperature. The ECO temperature can be adjusted in the range 10 K...+8 K. It refers to the room temperature setpoint. The ECO automatic energy saver requires an outside detector. It can be switched off, if required. This function operates as an automatic summer / winter function. It switches the heating off when the attenuated outside temperature crosses the heating limit. The heating limit is determined as follows: Heating limit = normal room temperature setpoint + ECO temperature Example: A normal room temperature setpoint of 20 C and an ECO temperature of 5 K give a heating limit of 15 C. This function operates as an automatic 24-hour heating limit switch. It switches the heating off when the actual or the composite outside temperature crosses the heating limit. The heating limit is determined as follows: Heating limit = current room temperature setpoint + ECO temperature Example: A current room temperature setpoint of 18 C and an ECO temperature of 5 K give a heating limit of 13 C. The current room temperature setpoint depends on the weekly heating program. This function takes into account when heating to a reduced level is provided - in contrast to ECO function 1. The heating will be switched on again when both the actual and the composite temperature have fallen below the limit by 1 K. The room temperature influence is dependent on: The setpoint / actual value deviation of the room temperature The slope of the heating curve The selected authority (0...100 %) With boiler temperature control, the room temperature influence ensures that there will be no control offset. In addition, the room temperature influence controls boost heating and quick setback. The room unit QAW70 is required for: Acquiring the room temperature Selecting the operating mode Entering the weekly heating program (changeover times and setpoints of normal and reduced room temperature) Selecting the operational level with the presence button Entering the holiday period CE2N2466E / 18.12.1998 Siemens Building Technologies 4/8 Landis & Staefa Division

Mechanical design 1 2 2466Z04 1 Setting knob for heating curve slope 2 Heating curve chart Controller Mounting The RVP102 is comprised of controller insert, which houses the electronics, the power section, the output relays and the operating elements, and the base, which carries the connection terminals. The controller insert is secured to the base by means of two screws. The operating elements for the heating engineer can be accessed after removal of a cover. The setting knob for selecting the heating curve slope is located on the front and can be accessed by the end-user. The RVP102 can be fitted in three different ways: Wall mounting (on a wall, in a control panel, etc.) Rail mounting (on a standard DIN mounting rail) Flush panel mounting (control panel door, etc.) Notes Engineering The cables of the measuring circuits carry extra low voltage The cables to the burner and the pump carry AC 24...230 V The local regulations on electrical installations must be complied with Detector cables must not be run parallel to mains carrying cable for loads like pump, burner, etc. Commissioning Settings on the controller RVP102 Settings on the room unit QAW70 Instructions The following settings and inputs must be made on the controller: Slope of heating curve Switching differential for burner control ECO heating limit Room temperature influence (authority of room temperature deviation on the control) Base point of heating curve (20 C or 35 C flow temperature) Changeover of compensating variable in function of the operational level (always weather-compensated control or changeover to room temperature-compensated control in case of the reduced level) Frost protection for the plant duser or deactivated Pump overrun of 6 minutes or 0 minutes (off) On the RVP102, the end-user can only change the slope of the heating curve. All other settings must be made by the heating engineer. The following settings and inputs must be made on the room unit: Operating mode Setpoints of normal and reduced room temperature Room temperature readjustments Heating program Time of day The controller is supplied with installation and commissioning instructions. Siemens Building Technologies CE2N2466E / 18.12.1998 Landis & Staefa Division 5/8

Technical data conformance to EMC directive 89/336/EEC Immunity EN 50082-2 Emissions EN 50081-1 Low voltage directive 73/23/EEC Safety EN 60730-1 Rated operating voltage AC 230 V Frequency 50 Hz Power consumption 7 VA Degree of protection IP40 D EN 60529 Safety class II EN 60730 Output relays Test class II Rated voltage AC 230 V Rated current 2 (2) A Contact current at AC 24...90 V 0.1...2 A, cos ϕ >0.5 Contact current at AC 90...250 V 0.02...2 A, cos ϕ >0.5 Rated current of ignition transformer 1 A max. (30 s max.) Switch-on current of ignition transformer 10 A max. (10 ms max.) Perm. ambient temperature Transportation and storage 5...+55 C Operation 0...55 C Permissible cable lengths to the detectors and the room unit Copper cable 0.6 mm dia 30 m Copper cable 0.5 mm 2 50 m Copper cable 1.0 mm 2 80 m Copper cable 1.5 mm 2 120 m Weight (net) 0.68 kg CE2N2466E / 18.12.1998 Siemens Building Technologies 6/8 Landis & Staefa Division

Connection diagrams Basic connections, low voltage side Basic connections, mains voltage side 2466A02 D1 D2 AC 230 V B9 AC 230 V F4 K4 F3 2466A01 F1 F2 E1 A6 B1 B9 E1 Room unit QAW70 (connections are interchangeable) Boiler temperature detector QAD22 Outside detector QAC32 Burner F1 F2 M1 N1 Thermal reset limit thermostat Manual reset safety limit thermostat Circulating pump Controller RVP102 Application example B9 A6 T 2466S01 A6 Room unit QAW70 E2 Load (space) B1 Boiler temperature detector QAD22 M1 Circulating pump B9 Outside detector QAC32 N1 Controller RVP102 E1 Boiler Siemens Building Technologies CE2N2466E / 18.12.1998 Landis & Staefa Division 7/8

Dimensions 96 19 26 26 26 26 15 144 114,7 19,7 14 138 +1 0 60,4 4,5 92 +0,8 0 56 112 2466M01 1997 Siemens Building Technologies Ltd. Subject to modification CE2N2466E / 18.12.1998 Siemens Building Technologies 8/8 Landis & Staefa Division