EN Motion detectors theluxa P0 WH 0 theluxa P0 BK 0 theluxa P00 WH theluxa P00 BK. Basic safety information WARNING anger of death through electric shock or fire! ¾Installation should only be carried out by a qualified electrician! 8 0 The device conforms with EN 09-- if correctly installed IP / according to EN 09 (depending on type of installation). Connection WARNING anger of death through electric shock or fire! ¾Installation should only be carried out by a qualified electrician! ¾isconnect power source! ¾Ensure device cannot be switched on! ¾Check absence of voltage! ¾Earth and bypass! ¾Cover or shield any adjacent live components. ¾, : Suited for switching FELV or a voltage of the same phases as L. Proper use etc. Motion detector for automatic lighting control dependent on presence and brightness Suitable for external wall or ceiling installation Suitable for entrances, garages, gardens, corridors, parks, Only intended for installation outside of arm's reach isposal ¾ispose of device in environmentally sound manner.. escription The device can be manually activated with a circuit breaker. After releasing the button (return of power) the device switches on (for at least secs or for the time set on the device).. Installation IP (category II) IP (category II) Motion detector with sensor head potentiometers for setting time (), brightness (lux) and sensitivity (metres) ¾ If applicable, use optional corner bracket (90090, 90090) or spacer frame (900908, 900909) for flexible installation as well as cable entry from side or top/bottom.
0V 0V 0FF Cut out here Knob out hole isconnect power source. Cut out here Knob out hole Make marks for the holes on the wall (with enclosed drill template/base). rill holes. Ø mm 0mm Feed cable through the seal of the base. Fasten base (and spacer frame) to the wall. φ mm φ mm or or L N Phase brown Neutral Earthing green/yellow, Relay contact 8 N 9 Tighten the screws. Neutral Earthing blue brown blue green/yellow Connect the individual wires to the appropriate teral. Tighten screws. Plug motion detector onto base and engage.
0 0 0 0 0 0 recommended installation height: m detector) Transverse detection area: m (transversal to the Frontal detection area: m (directly approaching the detector) etection angle: 0 or 00 ¾Connect motion detector to power supply. ismounting. Walking and alignment The walking is used to the detection area and to restrict it if necessary. Push ¾Using the screwdriver, carefully loosen the upper and lower snap-fits and pull the device away in a forward direction. Installation instructions As the detector reacts to variations in temperature, avoid the following situations: ¾o not direct motion detectors at objects with highlyreflective surfaces such as mirrors, etc. ¾o not install the motion detector near heat sources, such as heating outlets, air conditioning systems, lamps, etc. ¾o not direct the motion detector at objects that move in the wind, such as curtains, large plants, etc. ¾Pay attention to the direction of motion during the run. ¾Set the potentiometer time () to. The motion detector now only reacts to movements (independent of brightness). ¾Walk through the detection area at a right angle. After the motion detector has detected a movement, it switches on for s. ¾Pay attention to the direction of motion during the. s Align motion detector with sensor head The sensor head can be turned by downwards, upwards, and to the left and right. Left Right 0 m,0 m m 00 m m m
. Using cover clips If you want to change the preset time ( default) ¾Set the potentiometer to the desired time ( s - 0 ). s 0 s s 0 ¾Use the supplied clips, to adjust the motion detector to the desired detection area. ¾Remove the required section of the clips by using pliers or the like. ¾Then place on the lens and screw it in. ¾When required, use the provided double sided adhesive tape for fastening the cover clips. 8. Setting The motion detector has potentiometers for setting time (.), brightness (lux) and sensitivity (metres), etc. If you want to use the pulse function (e.g. for a staircase light timer switch) ¾Set the potentiometer to. The motion detector is switched on for < s, then off for 9 s. If it detects a movement again, it switches on again for s. Setting "twilight switch" function ¾Set potentiometer to position. Motion detector only reacts to brightness and is always on when the set brightness value has not been reached. Setting the sensitivity (meters) You can reduce the sensitivity; this also reduces the detection area. ¾Set potentiometer metres to the desired sensitivity. mtr Max. sensitivity s 00 Setting the brightness (lux) You can set different brightness values (lux) with the potentiometer. If you want to change the preset brightness ( lux default) lux ¾Set the potentiometer to the desired brightness ( 00 lux). 00 lux lux teach-in Lux Lux 0 Lux mtr Lux 0 Lux Lux 00 Lux or want a specific brightness value to be learned using the teach-in function ¾At the desired brightness, set the potentiometer to. The new value will be learned after s. ¾Leave the potentiometer at position. Setting the time () 00 Lux If the motion detector detects no further movement, it switches off after the set time. 9. Settings with remote control You can also enter the settings with remote controls thesenda P and thesenda S. Settings using thesenda P (9009) The following parameters or functions can be set with the- Senda P: 0 8 8 9 Test Test mode, ends after Auto return to Automatic mode On Switch on light (8 hrs) Range + Increase sensitivity 8 lux Brightness setpoint value lux
9 lux Brightness setpoint value lux Lux On eactivation of brightness measurement 800 lux Brightness setpoint value 800 lux 0 s Lighting time delay 0 s 0 s Lighting time delay 0 s max. time max. lighting time delay, 0 0 Lighting time delay 0 Lighting time delay Lighting time delay 8. time. lighting time delay, s 0 00 lux Brightness setpoint value 00 lux 00 lux Brightness setpoint value 00 lux lux Brightness setpoint value lux. lux. brightness setpoint value, lux Range Reduce sensitivity Teach-in Teaching in the brightness setpoint value Off Switch off light mode Twilight switch (motion detector deactivated) Settings by using thesenda S (9009) Creep under protection: yes Brightness setting range: 00/ lux uty cycle range: s 0 Permissible ambient temperature: C to + C Protection class: II Protection rating: IP (wall mounting) and IP (ceiling installation) (category II) according to EN 09 Switching capacity: A (cos ϕ = ) AX (cos ϕ = 0.) Min. switching capacity: V/0 ma Switching contact: μ-contact 0 V AC LE lamps < W 0 W LE lamps > W < 8 W 80 W LE lamps > 8 W 00 W Incandescent and halogen lamp load: 00 W Low-voltage halogen lights: 00 VA Fluorescent lamps VVG: uncorrected: 00 VA series-corrected: 00 VA parallel-corrected: 00 VA ( µf) Fluorescent lamps EB: 00 W Compact fluorescent lamps EB: 00 W. Contact Theben AG Hohenbergstr. Haigerloch GERMANY Phone +9 9-0 Fax +9 9-0 Hotline Phone +9 9-9 Fax +9 9-0 hotline@theben.de Addresses, telephone numbers, etc. www.theben.de mode Twilight switch (motion detector deactivated) Off short button push -> switches off the light On short button push -> switches on the light Auto return to Automatic mode Holiday mode Presence simulation Holiday mode The holiday mode is a presence simulation, which is intended to prevent burglary during temporary absence.. Technical data Frequency: Standby output: 0. Installation height: Operating voltage: 0 V AC, + % % 0 Hz W etection angle: 0, 00 etection area: transverse: max. m, frontal: max. m m