ADAPT Parasol EX a. Installation - Commissioning - Maintenance ADAPT Parasol EX a - m A1, B1

Similar documents
ADAPT PARASOL a. Installation - Commissioning - Maintenance ADAPT Parasol - m

ADAPT Parasol EXb. Installation. Installation Commissioning Maintenance A1, B1

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

PARASOL EX. Suspended comfort modules QUICK FACTS

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

21-light Remote Annunciator. Owner s Manual

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

PARAGON. Compact comfort module. Key figures

System technology. Demand controlled ventilation WISE.

Natural Ventilation Controller with 24vDC drive NVC-1204

DAP III Zone Master User s Guide

Digital Marine Exhaust Temperature Alarm

prestige Control Application Supplement - ACVMax

P2267 NETWORK INTERFACE

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

Control Application. Supplement - ACVMax

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Natural Ventilation Controller with 24vDC drive NVC-1204

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

FCCP 200: Fume-cupboard indicator and monitor

OVEN INDUSTRIES, INC.

OJ Waterline control system

User Guide: *IG1605EW*

Security Escort Central Console Software SE2000 Series

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

Super WISE. System product for Swegon s system for demand-controlled ventilation

PARAGONTM Comfort module for hotel rooms and hospital wards

prestige Control Application Supplement - TriMax

Corrigo E. Second generation which contains all applications and languages

SIRe Advanced Air Curtains Water Ambient, no heat

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TECOM SYSTEMS NETWORK MASTER

prestige Control Application Supplement - TriMax

5, SE GÅNGHESTER,

SEQUENCE OF OPERATIONS

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

Instructions for the fan motor control system, SILVER C

Waterborne Climate Systems

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

PONY 2/4 User Guide 2017

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

RPM1600 Series Room Pressure Monitors

User's Guide. CTS6000 control panel

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

Installation Instruction

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

HVAC Controls Upgrades: Requirement Details ( )

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

WLM2 WLTA WLTD WLTP WLCT2

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

2017 products.koer.com Page 1 of 14

Manual for the integration in BMS/GTC

AFA 500 FUME HOOD ALARMS

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

SCAN200E USER S MANUAL

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Air heater/cooler in combination with ground source heat pump

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser

DC 60 & DM 60 displays

200i/KN2, KN4 Firmware Revision Sheet

Air Comfort. Installation instructions (English) A

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

SUSA CONTROL AND MONITORING UNIT. Description INSTALLATION INSTRUCTIONS

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Reference Guide for Microprocessor Controller

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

Primo Hotel. General. Indoor climate units for hotel rooms

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Comfort Air Curtains with in-built dynamic advertising

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series...

OPERATING MANUAL UTY-RNNYM P/N English

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

Reference Guide for Microprocessor Controller

Swegon CASA. duct coils for heating. the supply air

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

RACK MONITORING SYSTEM - RAMOS Ultra

CLEVER CONTROL Version: V3

VCM-X / RNE Controller Operator Interface SD Technical Guide

TCM-2 Thyristor Control Module DATA SHEET

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Transcription:

ADAPT Parasol EX a Installation - Commissioning - Maintenance 2013-12-04 A1, B1 ADAPT Parasol EX a - m A2 B2 1

ADAPT Parasol EX a - m A3 B3 M6 B4 A4 A5 A6, B5 2

ADAPT Parasol EX a - m A7, B6 male thread DN (1/2 ) Note that clamp ring couplings require support sleeves inside the pipes. A8, B7 d/2 3

ADAPT Parasol EX a - m A9, B8 B A9, B8 C F G H B I C F G H I or SH or SH A10, B9 A B C D E F G H I or SH black white Sensor blue Condens red yellow 0-10V DC red black white 24V 24V G0 G0 24V 24V brown (US=white) blue (US=black) 0-10V DC G0 G0 G G0 1. 2. 1. Wiring when not using VOC sensor 2. Wiring when using VOC sensor 4 Sensor Condens Swegon reserves the right to alter specifications. brown (US=white) brown blue grey green blue (US=black) black 13 14 15 16 17 18 19 20 21 black white brown white CO2 brown VOC SHoR 2013-12-04 www.swegon.com

ADAPT Parasol EX a - m A11, B10 A12, B11 TORX T-25 / 1 x 8 A13, B12 A14, B13 Click! ON 1 2 ON 1 2 5

ADAPT Parasol EX a - m A15, B14 A16 B15 A17, B16 6

ADAPT Parasol EX a - m A18, B17 A19, B18 7

ADAPT Parasol EX a - m Super WISE Next Zone CONTROL Zone 1 2 3 4 MB2 5 6 7 8 MB1 RS -485 type Belden 9842 MB id 1 G 24 A B G 24 A B ADAPTER RJ12/WIRE Master/Master with SuperWISE system Modular 6/6 RJ12 Modular 6/6 RJ12 Modular 6/6 RJ12 22 23 24 25 22 23 24 25 22 23 24 25 MB id 4 Master MB id 8 Master MB id 12 Master Master/Slave with SuperWISE system Modular 6/6 RJ12 Modular 6/6 RJ12 22 23 24 25 22 23 24 25 22 23 24 25 MB id 4 Master MB id 1 Slave id 1 MB id 2 Slave id 2 BMS RS 485 Master/Slave with BMS sytem Modular 6/6 RJ12 Modular 6/6 RJ12 22 23 24 25 22 23 24 25 22 23 24 25 MB id 1 Master MB id 2 Slave id 1 MB id 3 Slave id 2 8

ADAPT Parasol EX a Installation -Commissioning - Maintenance 2013-12-04 K factor, sides 1 + 2 + 3 + 4 = k2 = max. flow ADAPT Parasol EX 2 3 k-factor per side Size Nozzle setting per side Side * ** 690 L 1&3 0.253 0.253 690 L 2&4 0 0.253 690 M 1&3 0.44 0.44 1 K factor, sides 1 + 3 = k1 = min. flow 4 3 690 M 2&4 0 0.44 690 H 1&3 0.693 0.693 690 H 2&4 0 0.693 1290 L 1&3 0,253 0,253 1290 L 2&4 0 0,665 1290 M 1&3 0,44 0,44 1290 M 2&4 0 1,16 1290 H 1&3 0,693 0,693 ADAPT Parasol EX a - m 1290 H 2&4 0 1,825 * ) = k-factor for adjusting the min. flow. ** ) = k-factor for adjusting the max. flow. q i ( ) 2 1 p = [Pa] k q = k p i [l/s] [pi Pa] q [l/s] k = k-factor ADAPT Parasol EX Size Example nozzle setting k pl *** ) k1 k2 690 LLLL 0.51 1.01 690 LHLH 0.51 1.89 690 MMMM 0.88 1.76 690 HHHH 1.39 2.77 1290 LLLL 0.51 1,84 1290 LHLH 0.51 4,16 1290 MMMM 0.88 3,20 1290 HHHH 1.39 5,04 *** ) All four sides on the unit can be set individually. The designation of the nozzle setting follows the order of figure to the left. k1 = No occupancy flow k2 = Max. occupancy flow k1 / k2 K p = 0.50 / 3.66 OBS! Any change between max. and min. flow will slightly change the nozzle pressure. 9

ADAPT Parasol EX Commissioning/checking the airflows Constant pressure in zone with CONTROL Zone or similar zone damper. 1. Check that all the WISE products are energised. T -25 1 x 8 Nozzle configuration H M L H = M= L= 2. Ensure that all the ADAPT Parasol EX modules have their correct C-factors and minimum and maximum flows preset. Ensure that all are set to the maximum flow commissioning position, (3 blue + 3 red LEDs are lit). 3. Check the flow, compare the maximum flow in the zone, adjust the pressure setpoint until the correct flow is obtained with TUNE Control. If Max. flow is not attained, another zone damper / other zone dampers should be temporarily closed. 4. Measure and record the airflow in the max. position on one ADAPT Parasol EX in the zone. 5. Reset to the min. flow, measure and record the airflow. 6. Set back to maximum flow. 7. Perform the same procedure for all the ADAPT Parasol EX modules in the zone. 8. Reduce the pressure setpoint setting on the zone damper if pressure is required for other zones, e.g. 5 Pa. 9. Commission the remaining zones, following the same procedure. X-shape 10. Check/commission the previous shut-off zones in the same way. 11. Restore the pressure setpoints on all the zone dampers. 12. Identify the reference zone, i.e. the zone with the lowest flow compared with the design maximum flow (e.g. by checking present airflow across each zone damper; using the TUNE Control hand unit). 13. Set the minimum flow on a number of ADAPT Parasol EX modules or use the zone damper for setting the minimum flow so that the ventilation system responds to the simultaneous load. Fan-shape 14. Now adjust the air handling unit s pressure setpoint until the zone damper of the reference zone is 85-90% open, (done by the SuperWISE, if it is used). 15. Restore all the settings and set all the ADAPT Parasol EX modules to normal position. 10

ADAPT Parasol EX Sensor module menu: To reach the menu, hold the left-hand and right-hand buttons down for five seconds. With the left-hand button ( ) you advance through the menus. With the right-hand button ( ) you confirm your selection and return to the menu. Press the left-hand button and select: 1. Alarm list 2. Commissioning 6. Return to menu Press the righthand button to confirm your selection 1. Alarm list: See the complete alarm list to the right. 2. Commissioning: There are then six selections in the commissioning menu, (press the left-hand button to advance in the menu). When you have marked a selection, the controller goes directly to that operating mode. 2.1 Min. airflow, holiday/ no occupancy for longer period 2.2 Min. airflow, no occupancy 2.3 Min. airflow, occupancy 2.4 Max. airflow, occupancy 2.5 Open cooling valve 2.6 Open heating valve Press the right-hand button to return to the menu. 1 and 3 are not used if ECOPulse and 2Step are in use 3, 4, 5. Not used. 6. Return to menu Function button Temperature sensor Presence detector Diodes for temperature, commissioning or alarm indication Function button Alarm list for the sensor module Alarm no. Type of alarm 32 16 8 4 2 1 Alarm 1 Supply voltage low Alarm 2 Supply voltage critically low Alarm 3 Ext temp missing Alarm 4 Ext temp error Alarm 5 Condensation sensor error Alarm 6 SM temp sensor error Alarm 7 SM button error Alarm 8 CO 2 sensor missing Alarm 9 VOC Error Alarm 10 Low pressure Alarm 17 SM comm error Alarm 18 Slave comm error Alarm 19 Pressure sensor comm error Alarm 20 VOC sensor comm error Alarm 21 No master request (slave) Alarm 22 Slave incompatible version Alarm 25 Heating comfort alarm Alarm 26 Cooling comfort alarm Alarm 27 Temp. Set point overlap alarm Alarm 28 Air quality comfort alarm Alarm 29 Condensation Alarm 33 24 V Out 1 overload error Alarm 34 24 V Out 2 overload error Alarm 35 24 V Out 3 overload error Alarm 41 Slave input common alarm Alarm 42 Slave output common alarm The alarm is displayed by a number of diodes when you have selected Alarm list (1) in the menu. Each diode represents a number as shown in the table above and the numbers should be added up to form an alarm number. Ex. The centremost blue and the two last red diodes are lit (xoxxoo) Diode-indicating function The centremost blue one corresponds to 16, the penultimate red one to 2 and the last red one to 1. The sum of - Green = Ok - Flashing Green = Condensation alarm these is 19, which is the alarm number. - Yellow = Alarm - Green/Yellow = Comfort alarm (not acute) ADAPT Parasol EX - m 3 parallel RJ12 ports (Modbus) for connecting a controller for instance, another sensor module or computer by means of Cable converter USB-RJ12 ON 1 2 Addressing the sensor module. 10 sensor modules can be connected to each master unit. Each one must have its own unique address in order to work. Switch for termination resistance. Set Switch 1 to the ON position for the last sensor module in the loop. 11

ADAPT Parasol EX a Installation - Commissioning - Maintenance 2013-12-04 1 5 2 6 ADAPT Parasol EX a - m 7 3 ON 1 2 ON 1 2 4 9 8 Art.no 942428024 12