Technical Data. Dimensions

Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

OPTIBAR P 1010/2010 C Supplementary instructions

EU DECLARATION OF CONFORMITY

OPTIBAR DP 7060 Supplementary Instructions

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Assembly. Host Sub-D Alarm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

SEK-3 Marine Grounding System

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Gas cylinder scale Model GCS-1

MANUAL Oil Level Sensor

Operating Instructions Edition 02/2007

Safety instructions VEGAPULS 64

Annubar Flowmeter Series

AND INSTALLATION MANUAL

Temperature Measurement Transmitters for field mounting

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Certificate of Compliance

Operating Manual MS220DA

Certificate of Compliance

OPTIWAVE X500 Supplementary Instructions

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Certificate of Compliance

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

4) Intrinsic Safety Certification

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Supplementary Installation and Operating Instructions. Category II2G

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

MANUAL Overflow sensor NVF-104/34-PF

IECEx Certificate of Conformity

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Multipoint temperature sensor

OilSET-1000 (12 VDC)

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

SET Installation and Operating Instructions. Level switch for one sensor

Installation and Operating Instruction

Certificate of Compliance

ATM Lighting sp. z o.o

Certification Supplement Manual

Survey of electrical equipment installed in hazardous areas on tankers

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

INSTRUCTION MANUAL (ATEX / IECEx)

Manual Power relay SR853

INSTRUCTION & SERVICE MANUAL

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Temperature sensors SensyTemp TSP Measuring insets TSA

Guide for hazardous areas

SET-2000 Hi Level/Oil

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

DB5 Intrinsically Safe Sounder Type DB-5

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Operating Manual MS220KA and MSR220KA

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Certificate of Compliance

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

ATM Lighting sp. z o.o

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Operating Manual MS220Vi and MSR220Vi

UL HAZARDOUS LOCATIONS SERVICES

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

standards: standards:

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

DICTATOR Hold-Open Systems for Hazardous Areas

Certification Supplement Manual

Declaration of conformity

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Installationsmanual GWSL1100/2100, GWML3100

Transcription:

0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation flush Output polarity NAMUR Assured operating distance s a 0... 4.05 mm Actual operating distance s r 4.5... 5.5 mm typ. 5 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 400 Hz Hysteresis H 1... 15 typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Switching state indicator all direction LED, yellow Functional safety related parameters MTTF d 2040 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type cable PVC, 2 m Core cross-section 0.75 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP66 / IP67 information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 1D; 3D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165F UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M18x1 4 24 37 LED 40 1

Electrical Connection BN L+ BU L- 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" Appropriate type NCB5-18GM...-N0... 100 µh ; a cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s on the metal housing components must be avoided. Dangerous electrostatic charges on the metal housing components can be avoided by incorporating these components in the equipotential bonding. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" Appropriate type NCB5-18GM...-N0... 100 µh ; a cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. 4

ATEX 3G (nl) Note This instruction is only valid for products according to EN 60079-15:2005, valid until 01-May-2013 Device category 3G (nl) for use in hazardous areas with gas, vapour and mist Standard conformity Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Protection from UV light Protection of the connection cable Connection parts II 3G Ex nl IIC T6 X The Ex-significant identification is on the enclosed adhesive label EN 60079-15:2005 Ignition protection category "n" 100 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-15. The explosion group depends on the connected and energy-limited supply circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! The sensor must not be exposed to ANY FORM of mechanical danger. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 5

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance CE marking Standards for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts for use in hazardous areas with gas, vapour and mist PF 13 CERT 2895 X II 3G Ex ic IIC T6 T1 Gc The Ex-significant identification is on the enclosed adhesive label EN 60079-0:2012, EN 60079-11:2012 Ignition protection category "ic" 100 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 6

ATEX 1D Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate ZELM 03 ATEX 0128 X Standards Appropriate type Maximum housing surface temperature II 1D Ex iad 20 T 108 C (226.4 F) The Ex-significant identification is on the enclosed adhesive label IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" NCB5-18GM...-N0... 100 µh ; a cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. 7

ATEX 3D Note This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D for use in hazardous areas with non-conducting combustible dust II 3D IP67 T 109 C (228.2 F) X The Ex-significant identification is on the enclosed adhesive label Standards EN 50281-1-1 Protection via housing and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! must be observed. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 9 K using an amplifier in accordance with 9 K EN 60947-5-6 The sensor must not be mechanically damaged. Protection of the connection cable The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. 8

ATEX 3D (tc) Device category 3D for use in hazardous areas with combustible dust Certificate of Compliance PF 15CERT3774 X II 3D Ex tc IIIC T80 C Dc The Ex-related marking can also be printed on the enclosed label. Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperlfuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature T Umax Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 61 C (141.8 F) using an amplifier in accordance with EN 60947-5-6 61 C (141.8 F) The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Protection of the connection cable The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. 9