Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Similar documents
Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Design Criteria. Installation

Technical Data. Installation

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

The Series LFII (TY3596) Residential

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

Model/Sprinkler Identification Number (SIN) Technical Data

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Numbers

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Care and Maintenance

Sprinkler Identification Numbers

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Worldwide Contacts. Technical Data

Technical Data. Sizes 2 12 Inch (DN50 DN300)

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Models BB, SD, HIP, and AP Specific Application Sprinklers for Protecting Attics General Description

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Worldwide Contacts.

TECHNICAL DATA. Wet 26a. February 22, 2009

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

CD6102 / CD6102 OC / CD6102-2

mechanical. OPERATION Rapidrop Global

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

INSTRUCTION MANUAL HS-229G

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

TECHNICAL DATA OBSOLETE

Full-scale tested, for use in wood truss construction. Listed for specific roof slopes from 4:12 to 12:12.

WATER POWERED OSCILLATING MONITOR

TECHNICAL DATA. 319a. January 27, 2012

Duct Mount. Installation Instructions

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

INSTALLATION AND OPERATION INSTRUCTIONS

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

MaxLite LED Vapor Tight Linear Fixture

Installation and Maintenance "L" and "LS" Series

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

TrueClean ToteCleaner

Sprinkler Identification Number (SIN)

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TrueClean ToteCleaner

Page 1 of 8 AUGUST 2011 TFP400. Technical Services

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

OWNER'S OPERATION AND MAINTENANCE MANUAL

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

MaxLite LED Round Pendant Highbay Series

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

Transcription:

Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit that allows water flow in one direction and prevents flow in the opposite direction. A resilient elastomer seal facing on the spring-loaded clapper ensures a leak-tight seal and nonsticking operation. The Model CV-FR Check Valves are designed to minimize water hammer caused by flow reversal. The Model CV-FR Riser Check Valve is furnished with grooved ends and can be installed using GRINNELL Grooved Couplings or GRINNELL Figure Flange Adapters. The Model CV-FR Valves have been designed with a removable cover for ease of field maintenance. These valves can be installed horizontally (with cover in the upward position) or vertically with the flow in the upward direction. Refer to Figure. To facilitate their use in wet-type automatic sprinkler system risers, the Model CV-FR Riser Check Valves are provided with threaded outlets for pressure gauges and a drain connection. They provide a more compact and economical alternative to an alarm check valve where a water motor alarm is not required. Provisions must be made for a local alarm using an approved flow switch (not included). The Model CV-FR Riser Check Valve is also Listed for use in conjunction with the TYCO Model DV- Deluge Valve in Preaction Systems under air pressure without the use of prime water. The Model CV-FR Riser Check Valves are a redesign for the Central Figure 90FR and GRINNELL Figure 90FR. NOTICE Never remove any piping component nor correct or modify any piping deficiencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. The Model CV-FR Riser Check Valve described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of this device. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted with any questions. Technical Data Approvals UL, C-UL, and FM Sizes to Inch (DN0 to DN00) Maximum Working Pressure 00 psi (0, bar) Valve Assembly Finish Red, non-lead paint Installation The Model CV-FR Riser Check Valves are to be installed in accordance with the following instructions:. The arrow cast on the Body must point in the direction of the flow.. Valves installed vertically must be positioned with the flow in the upward direction.. Valves installed horizontally must be positioned with the Cover facing up. Refer to Figure.. Grooved end pipe couplings used with the Model CV-FR Riser Check Valve must be installed in accordance with manufacturer s instructions. Page of OCTOBER 00 TFP90

TFP90 Page of Nominal Pipe Size Nominal Dimensions (mm) Cover Bolt Torq. Lbs.-ft. (Nm) Approx. Weight Lbs. (kg) ANSI DN O.D. (mm) A B C D E F J K DN0. (0,). (,). (,). (,). (,). (,) () 9.0 (,) () 9.0 (,) -/ DN. (,0) (0,). (,). (,).09 (,). 0.0 (,) -/ 0.0 (,), DN - (,) (0,). (,). (,).09 (,). 0.0 (,) -/ 0.0 (,) DN0.00 (,9). (,9). (,).0 (9,). (,)..0 (,0) -/.0 (,0) DN00.00 (,) 9. (,). (,). (,). (9,). (,).0 (,) 0 (9).0 (,). DN - (.) 0.0 (,).0 (90,).9 (,). (0,9).90 (,) 9.0 (,) 9.0 (,) DN. (,) 0.0 (,).0 (90,).9 (,). (0,9).90 (,) 9.0 (,) 9.0 (,). DN0 - (.).0 (9,).0 (0,). (,).0 (,).00 (,0) 0 ().0 (,) 0 ().0 (,) DN0. (,).0 (9,).0 (0,). (,).0 (,).00 (,0) 0 ().0 (,) 0 ().0 (,) DN00. (9,).00 (,) 0. (0,). (9,9). (,). (,) 0 ().0 (0,0) 0 ().0 (0,0) 0 DN0 0.0 (,) (,).00 (0,) 0. (9,). (,).0 (90,) 0 () 09. (9,) 0 () 09. (9,) DN00.0 (,9).0 (,). (,). (,). (,). (9,) 0 ().0 (,0) 0 ().0 (,0) FIGURE MODEL CV-FR RISER ECK VALVES NOMINAL DIMENSIONS /" B A O.D. C D J E F K /"

TFP90 Page of Detail Part Material Qty. Detail Part Material Qty. Detail Part Material Qty. Body Ductile Iron Clapper Facing Cover Ductile Iron Spring Cover Gasket Hex Cap Screw, Clapper - (DN0-00) Clapper 0 - (DN0-00) Nitrile Rubber, Zinc Plated SEE VIEW A AR 9 Ductile Iron Hinge Shaft Retaining Ring Retention Bolt Retaining Disc SEE DETAIL B EPDM Grade E FIGURE MODEL CV-FR RISER ECK VALVES ASSEMBLY 9 " - " (DN0-DN00) Locknut Adhesive Thread Sealer Nameplate Aluminum AR Rivet Spacer " - " (DN0-DN00) 9 0" - " (DN0 - DN00) VIEW A, DETAIL B 0" - " (DN0 - DN00), AR NOMINAL PRESSURE DROP IN POUNDS PER SQUARE IN (PSI).0.0.0.0.0 0.9 0. 0. 0. 0. 00 00 00 000 000 000 000 000 0000 0000 0000 IN (DN0) -/ IN (DN) IN (DN0) FLOW RATE IN LITRES PER MINUTE (LPM) ( GPM =, LPM) IN (DN00) IN (DN) IN (DN0) IN (DN00) 00 00 00 00 000 000 000 000 000 0000 FLOW RATE IN GALLONS PER MINUTE (GPM) FIGURE MODEL CV-FR RISER ECK VALVES PRESSURE LOSS DATA 0 IN (DN0) IN (DN00) 0000 000 0,0 0,0 0,0 0,09 0,0 0,0 0,0 0,0 0,0 NOMINAL PRESSURE DROP IN BAR ( PSI = 0,09 BAR)

TFP90 Page of A C E B D Nominal Pipe Size Nominal Dimensions (mm) ANSI DN O.D. (mm) A B C D E DN0. (0,). (,).0 (,). (, 0. (,) -/ DN. (,0) (0,). (,).. (,) -/, DN (,) (0,). (,).. (,) -/ DN0.00 (,9). (,). (,0.. (,) -/ DN00.00 (,) 9. (,). (9,9).. (,), DN (,) 0.0 (,). (09,).00 (,0). (0,) DN. (,) 0.0 (,). (09,).00 (,0). (0,), DN0 (,).0 (9,). ().00 (,0)). (,) DN0. (,).0 (9,). ().00 (,0). (,) DN00. (9,).00 (,) 9. (,).0 (,). (,) 0 DN0 0.0 (,) (,) 0.0 (,).0 (90,). (,) DN00.0 (,9).00 (,).0 (9,). (9,).00 (,) FIGURE MODEL CV-FR RISER ECK VALVE WITH TRIM COMPONENTS NOMINAL DIMENSIONS

TFP90 Page of NO. P/N 9-9--00 Inch (DN0) DESCRIPTION QTY. P/N 00 psi/ 000 kpa Water Pressure Gauge.. 9---00 /" Gauge Test Valve.. -00--00 /" Plug............. " Angle Valve......... /" x " Nipple........ /" x " Nipple........ " x " Nipple.......... -0--00 NOTES:. All Fittings and Nipples are galvanized (Standard Order).. : Common Hardware. MAIN DRAIN VALVE (NORMALLY CLOSED) NO. P/N 9-9--00 -/ Inch (DN) through Inch (DN0) DESCRIPTION QTY. P/N 00 psi/ 000 kpa Water Pressure Gauge.. 9---00 /" Gauge Test Valve.. -00--00 /" Plug............. -/" Angle Valve...... /" x " Nipple........ /" x " Nipple........ -/" x " Nipple....... -0--00 SYSTEM PRESSURE GAUGE SUPPLY PRESSURE GAUGE NO. P/N 9-9--00 Inch (DN00) through Inch (DN00) DESCRIPTION QTY. P/N 00 psi/ 000 kpa Water Pressure Gauge.. 9---00 /" Gauge Test Valve.. -00--00 /" Plug............. " Angle Valve......... /" x " Nipple........ /" x " Nipple........ " x " Nipple.......... -0--009 MODEL CV-FR RISER ECK VALVE FIGURE MODEL CV-FR RISER ECK VALVES TRIM PARTS LIST COVER OUTLET FLOW INLET OUTLET COVER FLOW INLET VERTICAL ORIENTATION HORIZONTAL ORIENTATION FIGURE MODEL CV-FR RISER ECK VALVES INSTALLATION

TFP90 Page of Care and Maintenance NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this decision. After placing a fire protection system in service, notify the proper authorities and advise those responsible for monitoring proprietary and/or central station alarms. Owners are responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA ), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairments must be immediately corrected. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (0) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (0) years from date of shipment by TFSBP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Model CV-FR Check Valves Specify: Size and P/N (below). (DN0)............... P/N 9-90--00 -/ (DN)............ P/N 9-90--0, mm (DN)......... P/N 9-90--0 (DN0)............... P/N 9-90--00 (DN00).............. P/N 9-90--00, mm (DN)....... P/N 9-90-- (DN).............. P/N 9-90--00, mm (DN0)....... P/N 9-90-- (DN0).............. P/N 9-90--00 (DN00).............. P/N 9-90--00 0 (DN0)............. P/N 9-90--00 (DN00)............. P/N 9-90--0 Model CV-FR Riser Check Valve Trim Assembly Specify: Size and P/N (below). (DN0)............... P/N 9-9--00 -/ (DN)............ P/N 9-9--00, mm (DN)......... P/N 9-9--00 (DN0)............... P/N 9-9--00 (DN00).............. P/N 9-9--00, mm (DN)....... P/N 9-9--00 (DN).............. P/N 9-9--00, mm (DN0)....... P/N 9-9--00 (DN0).............. P/N 9-9--00 (DN00).............. P/N 9-9--00 0 (DN0)............. P/N 9-9--00 (DN00)............. P/N 9-9--00 Copyright 00-00 Tyco Fire Suppression & Building Products. All rights reserved.