Table of Contents. W2W Open

Similar documents
Introduction. What is the W2W Open controller?

Introduction. What is the W2W Open controller?

Table of Contents. WSHP Open v3

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

Introduction. What is the RTU Open controller?

Table of Contents. Unit Ventilator

I/O ZONE 560/583 USERS GUIDE

Reciprocating Chiller

Fan Coil for AppController overview and specifications

Unit Vent for AppController overview and specifications

Digital Precise Air Control - DPAC

1.0 Digital Controller

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

MicroTech Self-Contained Air Conditioning System

MicroTech Unit Ventilator

Reference Guide for Microprocessor Controller

TEC3000 Series Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

Reference Guide for Microprocessor Controller

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Open Protocol Data Communications

BACnet Points List for Single Compressor Water to Water PROSSWWE-01

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

Reference Guide for Microprocessor Controller

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

York 25-Ton VAV Rooftop Unit

Installation and Maintenance Manual IM

1.0 Digital Controller

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

Networkable Fan Coil Controller Specification and Installation Instructions

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

UNT Applications. Using UNT Applications...3. Introduction Key Concepts UNT Controller Applications Fan Coil Units...

Installation Instructions

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

RPM1600 Series Room Pressure Monitors

MicroTech Rooftop/RMC

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Owner s Manual. Part Number 33CSCPACHP-01

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

HEAT HEAT HEAT COOL COOL

TC-9102 Applications

Pioneer Gold Controller Technical Guide

Temperature Controllers

Siemens RDY2000BN. Start Up Guide

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

OVEN INDUSTRIES, INC.

Installation, Start-Up, and Operating Instructions

HVAC Controls Upgrades: Requirement Details ( )

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

Advanced Installation and Configuration Instructions

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Carbon Monoxide Transmitter

AdaptAire. Digital Control System. User Manual

WaterFurnace FX10 Application Guide Reversible Chiller

DAP III Zone Master User s Guide

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

American University Design Standards

I/A Series 716C 1/16 DIN Temperature Controller

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

CLEANROOM MONITOR CR3A Network - Installation Instructions

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

What is the Carrier Connect Wi-Fi Thermostat?

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Natural Ventilation Controller with 24vDC drive NVC-1204

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

HEAT COOL. Meets Commercial California Title 24

Wiring Diagrams. NOTE: This literature applies to units produced after 11/3/96 (software version 2.0 or greater) DIAGRAM INDEX

Natural Ventilation Controller with 24vDC drive NVC-1204

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

OWNER S MANUAL Venstar Inc. 08/07

INSTALLATION INSTRUCTIONS

PIR Ready VT76xx Series Programmable & Non-Programmable Thermostats For Commercial HVAC Applications. BACnet Integration Manual September 1, 2010

Sequence of operation

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

Your Home. Jacco & Assoc.

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Metasys Integrator TITUS Application

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

IQ System Technical Guide

P/N f. HomeWorks QS Palladiom Thermostat Configuration Guide

What is the Carrier Connect Wi-Fi Thermostat?

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Transcription:

W2W Open Points and Properties CARRIER CORPORATION 2013 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-457-01 3/27/2013

Table of Contents Introduction... 1 What is the W2W Open controller?... 1 Safety Considerations... 3 Appendix A: Points/Properties... 4 Status... 4 Unit Configuration... 5 Setpoints... 7 Alarm Configuration... 8 Service Configuration... 9 Maintenance... 13 Alarms... 17 Linkage... 18 I/O Points... 18 Index... 21 W2W Open i

Introduction What is the W2W Open controller? The Water-to-Water (W2W) Open (part #OPN-WSHPW2WM) controller may be utilized standalone, or as part of an i-vu Open, or third-party BACnet-distributed control system. The W2W Open control is designed to heat or cool the load water and to maintain the leaving water or entering water at the control setpoint. Each W2W Open controller supports up to 4 stages of capacity and up to 3 compressor stages (with compressor status feedback). You can have controller slaves for equipment or systems with up to 8 stages of control. On board DIP switches allow you to select the baud rate and choose one of the following protocols: BACnet Modbus Johnson N2 LonWorks Carrier s diagnostic display tools such as BACview 6 Handheld device or Virtual BACview application can be used with the W2W Open controller via the 5-pin J12 Access port. Refer to illustration below. W2W Open 1

Introduction CAUTION If there is a jumper on the Format pins and power is cycled to the controller, all Modbus, N2, and LonWorks points will be lost. 2 W2W Open

Safety Considerations Disconnect electrical power to the W2W Open before wiring it. Failure to follow this warning could cause electrical shock, personal injury, or damage to the controller. When you handle the W2W Open: Do not contaminate the printed circuit board with fingerprints, moisture, or any foreign material. Do not touch components or leads. Handle the board by its edges. Isolate from high voltage or electrostatic discharge. Ensure that you are properly grounded. W2W Open 3

Appendix A: Points/Properties Appendix A: Points/Properties The following tables describe all of the possible settings for your controller on the Properties > Equipment page. Some of the properties are available only when other settings have been enabled. For example, Service Configuration > Total Controller Stages is visible only when Configuration > Service Configuration > Operational Type is set to Multi-unit Master. Status Navigation: i-vu / Field Assistant: BACview : Properties > Equipment > Status HOME > STATUS Range Operating Mode The controller's configured operating mode. Single Unit Multi-unit Master Slave Unit System Mode The controller's current operating mode. OFF Cooling Heating Test Start Delay Safety Shutdown Shutdown Pump Only Equipment Alarm Indicates the controller has an active alarm. See Service Configuration (page 9) for causes. Normal Normal/Alarm Compressor Capacity Displays the equipment's calculated compressor capacity required to meet the load conditions. Total System Cmpr Capacity Displays all equipment's calculated compressor capacity when the control is configured as a Multi-unit Master. (Not displayed on Single Unit or Slave controllers.) Leaving Load Water Temp Displays the Leaving Load Water Temperature sensor's current value. Leaving Water Temp Setpoint Displays the current leaving load water temperature setpoint, including reset, where applicable when Control Type is set to Lvg H2O Temp Ctrl (leaving water temperature control). Entering Load Water Temp Displays the Entering Load Water Temperature sensor or network variable's current value. Entering Water Temp Setpoint Displays the current entering load water temperature setpoint, including reset, where applicable when Control Type is set to Entr H2O Temp Ctrl (entering water temperature control). 0 to 100% 0 to 100% -40 to 245 F 40 to 120 F -40 to 245 F 40 to 120 F 4 W2W Open

Range SPT Temp Displays an SPT temperature sensor or network variable's current value. 0 to 100% External T1 Temp Displays the External T1 Temp network variable's current value. -50 to 150 F Outdoor Air Temperature Displays the outdoor air temperature sensor or network variable's current value. Space Relative Humidity The relative humidity sensor or network variable's current value. -40 to 245 F 0 to 100% Load Water Pump The Load Water Pump binary output's current commanded status. Source Water Pump / Isolation Valve Displays the Source Water Pump / Isolation Valve binary output's current commanded status. Leaving Source Water Temp Displays the Leaving Source Water Temperature sensor's current value. Entering Source Water Temp Displays the current Entering Source Water Temp (calculated) or network variable. Shutdown When Active, provides a means to stop heating and cooling in an orderly manner. All alarms are reset. Continues to display current active alarms. Off Off/On Off/Close Off/Close On/Open -40 to 245 F -40 to 245 F Inactive Inactive/Active Unit Configuration Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Configuration > Unit Configuration HOME > CONFIG > UNIT Default/Range Heat s or disables heating operation. Heating Lockout Temperature Heating is inhibited above this outdoor air temperature. Heating Setpoint OA Reset s Hot Water Supply Setpoint to reset, based on outdoor air temperature. If enabled, the heating setpoint resets if all of the following are true: Heat (Unit Configuration) is set to A valid outdoor air temperature is present The control has not been configured for Slave operation (Service Configuration) OAT HW Supply Reset Low Limit The outdoor air temperature that causes the Hot Water Supply Setpoint to reset to the highest temperature, when Heating Setpoint OA Reset is active. Disable/ 60 F -40 to 245 F Disable Disable/ 30 F 20 to 60 F W2W Open 5

Appendix A: Points/Properties Default/Range OAT HW Supply Reset High Limit The outdoor air temperature that causes the Hot Water Supply Setpoint to reset to the lowest temperature, when Heating Setpoint OA Reset is active. This value cannot be less than the configured Heating Lockout Temperature. Maximum OA HW Reset The maximum amount of reset allowed for the Hot Water Supply Setpoint, when the Heating Setpoint OA Reset function is active. 60 F 30 to 60 F 20 F 0 to 40 F Cool s or disables cooling operation. Cooling Lockout Temperature Cooling operation is disabled if outdoor air temperature exceeds this. When Heat is set to, you cannot set this value less than the Heating Lockout Temperature plus 2 F. Cooling Setpoint OA Reset s Chilled Water Supply Setpoint to reset, based on outdoor air temperature. If enabled, functions only if all of the following are true: Cool (Unit Configuration) is set to A valid outdoor air temperature is present The control has not been configured for Slave operation (Service Configuration) OAT CHW Supply Reset Low Limit The outdoor air temperature which causes the Chilled Water Supply Setpoint to reset to the highest temperature, when Cooling Setpoint OA Reset is active. The OAT CHW Supply High Limit cannot be less than the configured Cooling Lockout Temperature. OAT CHW Supply Reset High Limit The outdoor air temperature which causes the Chilled Water Supply Setpoint to reset to the lowest temperature, when Cooling Setpoint OA Reset is active. Maximum OA CHW Reset The maximum amount of reset allowed for the Chilled Water Supply Setpoint, when the Cooling Setpoint OA Reset function is active. RH Cooling Setpoint Reset s limit on the amount of outdoor air Chilled Water Supply Setpoint reset, based on relative humidity. Active only if all of the following are true: Cool (Unit Configuration) is set to RH Cooling Setpoint Reset is set to A valid outdoor air temperature is present A valid relative humidity value is present Power Fail Restart Delay How long the controller delays normal operation after the power is restored. Typically used to prevent excessive demand when recovering from a power failure. Occupancy Schedules s or disables the occupancy schedule function. Disable/ 65 F 62 to 90 F Disable Disable/ 65 F 65 to 85 F 90 F 70 to 100 F 10 F 0 to 25 F Disable Disable/ 60 secs 0 to 600 secs Disable Disable/ Sensor Calibration Space Temperature (T1) The current space temperature. -40 to 245 F Local Space Temp (T1) Calibration A calibration offset value that allows you to adjust the local space temperature sensor to match a calibrated standard that is measuring the temperature in the same location. 0 F -9.9 to 10 F 6 W2W Open

Default/Range Leaving Load Water Temperature The current leaving load water temperature. -40 to 245 F Leaving Load Wtr Temp Sensor Calibration A calibration offset value to allow you to adjust the local leaving source water temperature sensor to match a calibrated standard measuring the temperature in the same location. 0 F -9.9 to 10 F Entering Load Water Temperature The current entering load water temperature. -40 to 245 F Ent Load Wtr Temp Sensor Calibration A calibration offset value that allows you to adjust the local entering load water temperature sensor to match a calibrated standard, measuring the temperature in the same location. 0 F -9.9 to 10 F Leaving Source Water Temperature The current leaving source water temperature. -40 to 245 F Leaving Source Temp Sensor Calibration A calibration offset value that allows you to adjust the local leaving source water temperature sensor to match a calibrated standard that is measuring the temperature in the same location. 0 F -9.9 to 10 F Outdoor Air Temperature The current outdoor air temperature. -40 to 245 F Outdoor Air Temp Sensor Calibration A calibration offset value you can adjust so the outdoor air temperature sensor matches a calibrated standard that measures the temperature in the same location. 0 F -9.9 to 10 F Space Relative Humidity The current value of space relative humidity. 0 to 100% Space RH Sensor Calibration A calibration offset value that allows you to adjust the space relative humidity sensor to match a calibrated standard that is measuring the humidity in the same location. 0%rh -15 to 15%rh Setpoints Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Configuration > Setpoints HOME > CONFIG > UNITS > SETPOINTS Range Cooling Supply Water Temperature Chilled Water Supply Setpoint - The current chilled water supply setpoint and the base setpoint prior to any reset or demand limit functions. Heating Supply Water Temperature Hot Water Supply Setpoint - The current hot water supply setpoint and the base setpoint prior to any reset or demand limit functions. Relative Humidity 44 F 40 to 60 F 120 F 90 to 140 F W2W Open 7

Appendix A: Points/Properties Range Occ Relative Humidity Setpoint The control setpoint used during occupied periods. 60% 0 to 100% Heating Demand Limit Demand Level 1 Heat Adj The number of degrees the Hot Water Supply Setpoint reduces when receiving a Demand Limit level 1 signal. Demand Limit 2 Heat Adj The number of degrees the Hot Water Supply Setpoint reduces when receiving a Demand Limit Level level 2 signal. Demand Limit 3 Heat Adj The number of degrees the Hot Water Supply Setpoint reduces when receiving a Demand Limit level 3 signal. Cooling Demand Limit 3 F 0 to 10 F 5 F 0 to 10 F 7 F 0 to 10 F Demand Level 1 Cool Adj The Chilled Water Supply Setpoint reduces by this number of degrees when receiving a Demand Limit level 1 signal. Demand Level 2 Cool Adj the Chilled Water Supply Setpoint reduces by this number of degrees when receiving a Demand Limit level 2 signal. Demand Level 3 Cool Adj the Chilled Water Supply Setpoint reduces by this number of degrees when receiving a Demand Limit level 3 signal. 3 F 0 to 10 F 3 F 0 to 10 F 4 F 0 to 10 F Alarm Configuration Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Configuration > Alarm Configuration HOME > CONFIG > UNIT > ALARM Range Leaving Load Water Temperature Alarm Low Leaving Load Water Temp Alarm Limit The Leaving Load Water Temp must drop below this value to generate a Leaving Load Water Temperature Alarm. There is a fixed hysteresis of 2 F for return to normal. NOTE This value should be set to at least 4 F below the configured cooling setpoint. High Leaving Load Water Temp Alarm Limit The Leaving Load Water Temp must exceed this value to generate a Leaving Load Water Temperature Alarm. There is a fixed hysteresis of 2 F for return to normal. NOTE This value should be set to at least 10 F above the configured cooling setpoint. 42 F 0 to 60 F 125 F 120 to 160 F Entering Load Water Temperature Alarm 8 W2W Open

Range Low Entering Load Water Temp Alarm Limit The Entering Load Water Temp must drop below this value to generate an Entering Load Water Temperature Alarm. There is a fixed hysteresis of 2 F for return to normal. High Entering Load Water Temp Alarm Limit The Entering Load Water Temp must exceed this value to generate an Entering Load Water Temperature Alarm. There is a fixed hysteresis of 2 F for return to normal. 42 F 0 to 60 F 125 F 120 to 160 F Outdoor Air Temperature Alarm Low OAT Alarm Limit The Outdoor Air Temperature must drop below this value to generate an Outdoor Air Temp Alarm. There is a fixed hysteresis of 1 F for return to normal. High OAT Alarm Limit The Outdoor Air Temperature must exceed this value to generate an Outdoor Air Temp Alarm. There is a fixed hysteresis of 1 F for return to normal. -65 F -65 to 245 F 245 F -65 to 245 F Space Humidity Alarm Occupied High RH Alarm Limit The relative humidity sensor must exceed this value to generate a Space Relative Humidity Alarm in the occupied mode if RH Cooling Setpoint Reset (Unit Configuration) is set to. There is a fixed hysteresis of 5%rh for return to normal.k Unocc High RH Alarm Limit The value that the relative humidity sensor must exceed to generate a Space Humidity Alarm in the unoccupied mode if RH Control is set to. There is a fixed hysteresis of 5%rh for return to normal. Alarm Delay (min/%rh) Determines the amount of delay before an occupied RH alarm is generated when the controller transitions to the occupied mode. The delay time equals this value multiplied by the difference between the sensor RH value and the occupied RH setpoint plus 15 minutes. 100 F 0 to 100 100 F 0 to 100 5 minutes 0 to 30 minutes Service Configuration Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Configuration > Service Configuration HOME > CONFIG > SERVICE Default/Range Unit Size Nominal Capacity Used to define the size of the equipment shown on the Graphic page. NOTE The large frame equipment displays when Unit Size Nominal Capacity is configured for > 12 ton. Operation Type Defines whether the control operates as a Master or Slave, in a multi-unit system. NOTE There is no selection for a Slave unit, as it is. Set to Single/Slave Unit to enable automatic communication with its designated Master. 30 ton 1 to 150 ton Single/Slave Unit Single/Slave Unit Multi-unit Master W2W Open 9

Appendix A: Points/Properties Default/Range Control Type Defines whether the control monitors and uses Leaving Load Water Temperature or Entering Load Water Temperature to control this equipment. NOTE If set to Entr H2O Temp Ctrl, a valid entering load water temperature sensor or Network sensor value must be present, otherwise the control automatically uses leaving load water temperature for control. Control Mode Selection Select one of the following modes to control the device: Manual Heat The equipment operates as a heating source only Manual Cool The equipment operates as a cooling source only OAT The equipment transitions between a heating and cooling source, as determined by the outdoor air temperature SPT The equipment transitions between a heating and cooling source, as determined by an SPT temperature sensor System T1 Temp The equipment transitions between a heating and cooling source, as determined by a networked temperature variable Total Controlled Stages Defines the total number of system compressor stages when the control is configured as a Multi-unit Master. System compressor stages are the total number of compressor stages controlled by both the multi-unit Master and its associated Slaves. Configuration > Service Configuration > Operation Type must be set to Multi-unit Master. System Stage # Assigned to Y1 The stage number assigned to this controller's Y1 binary output, when the control is configured as a Slave in a multi-unit system. Configuration > Service Configuration > Operation Type must be set to Single/Slave Unit and valid communications established between the Slave and its associated Master controller. Lvg H2O Temp Ctrl Lvg H2O Temp Ctrl Entr H2O Temp Ctrl OAT Manual Heat Manual Cool OAT SPT System T1 Temp Two Stage One Stage Two Stage Three Stage Four Stage Five Stage Six Stage Seven Stage Eight Stage 3 0 to 8 Compressor Stages The number of stages of compression. Stage Number of 2nd Compressor Configures the stage number assigned by the controller to a second compressor for the locally installed equipment. For example, on a heat pump with 2 compressors, each equipped with unloaders, the second compressor would be stage 3. Stage Number of 3rd Compressor Configures the stage number assigned by the controller to a third compressor for the locally installed equipment. For example, on a heat pump with 3 single-stage compressors, the third compressor would be stage 3. Reversing Valve Type The reversing valve's signal output type. O - A call for cooling energizes the reversing valve B - A call for cooling energizes the reversing valve Two Stage One Stage Two Stage Three Stage Four Stage N/A Three Four N/A Two Three Four O O/B 10 W2W Open

Cool PID This BACnet Object calculates the amount of capacity required to satisfy the Chilled Water Supply Setpoint and allows access to the control loop's tuning parameters. NOTE The following default values should be changed only by a technician trained in PID Loop algorithms. Action Update Interval Proportional Integral Derivative Deadband Bias Heat PID This BACnet Object calculates the amount of capacity required to satisfy the Hot Water Supply Setpoint and allows access to the control loop's tuning parameters. NOTE The following default values should be changed only by a technician trained in PID Loop algorithms. Action Update Interval Proportional Integral Derivative Deadband Bias Occ Contact Normal Logic State Specifies the type of contact at input #9 for the normal or unoccupied state. Min Source Water Temp Heating Determines the minimum source water temperature before the unit starts heating. Max Source Water Temp Heating Determines the maximum source water temperature before the unit starts heating. Min Source Water Temp Cooling Determines the minimum source water temperature before the unit starts cooling. Max Source Water Temp Cooling Determines the maximum source water temperature before the unit starts cooling. Isolation Valve Type Configures the controller for the type of installed (load water) isolation valve. Iso Valve Close Delay Configures the amount of time (in seconds) that the source water isolation valve remains open after heating or cooling stops. Pump Stop Delay Configures the amount of time (in seconds) that the load pump runs when the unit transitions to unoccupied mode or is otherwise shutdown. Default/Range direct 0:30 25 5.0 0 0 0 reverse 0:30 25 5.0 0 0 0 Open Open/Closed 60 F 10 to 60 80 F 65 to 110 F 60 F 30 to 60 95 F 85 to 120 F NC NC (normally closed) NO (normally open) 45 secs 0 to 180 secs 45 secs 0 to 180 secs Equipment Alarm Lamp Output Initiators W2W Open 11

Appendix A: Points/Properties Default/Range Master Comm Fail Alarm When set to, if communications between a Slave unit that has previously established communications with its Multi-Unit Master, fails to receive communications, the controller initiates an Equipment Alarm and energizes the Alarm Lamp binary output. CW Linkage Failure Alarm When set to, allows a Condenser Water Linkage failure to initiate an Equipment Alarm and energize the Alarm Lamp binary output. Compressor Alarm When set to, any Compressor Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Lvg Load Water Temp Alarm When set to, any Leaving Load Water Temperature Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Lvg Load Wtr Sensor Fail Alarm When set to, any Leaving Load Water Sensor Failure Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Ent Load Water Temp Alarm When set to, any Entering Load Water Temperature Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Ent Load Wtr Sensor Fail Alarm When set to, any Entering Load Water Sensor Failure Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Lvg Source Water Temp Alarm When set to, any Leaving Source Water Temperature Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Lvg Source Wtr Sensor Fail Alarm When set to, a Leaving Source Water Sensor Failure Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. NW Ent Source Water Temp Fail Alarm When set to, if the network value of the entering source water temperature is no longer valid or stops communicating, the controller initiates an Equipment Alarm and energizes the Alarm Lamp binary output. OA Temperature Alarm When set to, any Outdoor Air Temperature Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. OA Sensor Failure Alarm When set to, an Outdoor Air Temperature Sensor Failure Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. SPT/T1 Failure Alarm When set to, an SPT Sensor Failure Alarm or System T1 Sensor Alarm indicated by the controller initiates an Equipment Alarm and energizes the Alarm Lamp binary output. To determine the alarm origin, select SPT or System T1 Temp for the Control Mode Selection. High RH Alarm When set to, a High Space Relative Humidity Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. RH Sensor Fail Alarm When set to, a Relative Humidity Sensor Failure Alarm indicated by the controller also initiates an Equipment Alarm and energizes the Alarm Lamp binary output. Disable /Disable /Disable /Disable /Disable /Disable /Disable /Disable /Disable /Disable Disable /Disable /Disable /Disable /Disable /Disable /Disable 12 W2W Open

Service Test Default/Range Service Test to stop automatic control so you can test the controller's outputs. Automatically resets to Disable after 1 hour. Isolation Valve Test to energize the controller's Isolation Valve output. Service Test must be set to. Water Pump Test to start the controller's Load Water Pump output. Service Test must be set to. Compressor Test to test compressor cooling and heating operation. Compressor Test starts each of the configured stages in sequence for cooling, sets the reversing valve for heating, and stages down again in reverse sequence, reducing capacity until all stages are stopped. Each step will operate for 1 minute. Service Test must be set to. Alarm Indicator Test to start the controller's Alarm Indicator Lamp output. Service Test must be set to. Disable Disable/ Disable Disable/ Disable Disable/ Disable Disable/ Disable Disable/ Maintenance Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Maintenance HOME > MAINT Default/Range Unit Effective Heat Setpoint The current Hot Water Supply Setpoint. May include offsets resulting from OA Reset or Demand Limit. Effective Cool Setpoint The current Chilled Water Supply Setpoint. May include offsets resulting from OA/RH Reset or Demand Limit. -40 to 245 F -40 to 245 F Control Point Displays the point used to control this equipment. Lvg Load Water Temp Entr Load Water Temp Active Compressor Stages The number of compressor stages currently operating. 0 to 4 Changeover Timeguard Displays the current state of the timeguard, which restricts the operational changeover between heating and cooling, or vice versa. Inactive/Active Reversing Valve The current status of the reversing valve on the local controller. De-energized Energized W2W Open 13

Appendix A: Points/Properties Leaving Load Water Temp Source The source of the Leaving Load Water Temp value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Entering Load Water Temp Source The source of the Entering Load Water Temp value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Leaving Source Water Temp Source The source of the Leaving Source Water Temp value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Entering Source Water Temp Source The source of the Entering Source Water Temp value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Default/Range N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value 14 W2W Open

SPT Source the source of the SPT Temp value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value System T1 Sensor The source of the System T1 Sensor value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Outdoor Air Temperature Source The source of the Outdoor Air Temperature value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Relative Humidity Source The source of the Space Relative Humidity value. States: N/A - No sensor value associated with this device Local - A physical sensor is wired and connected to the appropriate input channel of this controller Network - A network sensor value provided to this controller Linkage - The sensor value from a linked device, obtained through air or water linkage Locked Value - The controller s sensor input is manually locked to a specific value Default/Range N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value N/A Local Network Linkage Locked Value Occupancy Occupancy Status The controller's occupancy status. Unoccupied/Occupied W2W Open 15

Appendix A: Points/Properties Default/Range BAS On/Off Determines the controller's occupancy state and can be set over the network by another device or third party BAS. Options: Inactive Occupancy is determined by a configured schedule Occupied The controller is always in the occupied mode Unoccupied The controller is always in the unoccupied mode Inactive Occupied Unoccupied Schedules The Schedule object's current status in the controller. Unoccupied/Occupied Occupancy Contact The Remote Occupancy Contact input's current status. Global Occupancy The System Occupancy network input's current state. Inactive Inactive Active Occupied Inactive Inactive Active Occupied Reset Heating Supply Setpoint Reset The Hot Water Supply Setpoint's current reset method. Calculated OA Htg Reset The amount of reset applied to the Hot Water Supply Setpoint when OAT Reset or Demand Limit are active. Inactive Inactive OAT Reset Demand Limit 0 to 40 F Cooling Supply Setpoint Reset The Chilled Water Supply Setpoint's current reset method. Inactive Calculated OA Clg Reset The amount of reset applied to the Chilled Water Supply Setpoint when OAT Reset, RH Override, or Demand Limit are active. Calculated RH Clg Reset The amount the Calculated OA Clg Reset is reduced when the Space Relative Humidity exceeds the Occ Relative Humidity Setpoint. Applies to the Chilled Water Supply Setpoint only. Inactive OAT Reset Demand Limit 0 to 25 F 0 to -25 F Demand Limit System Cool Demand Level The network point used to provide the cool demand level input to this controller. System Heat Demand Level The network point used to provide the heat demand level input to this controller. Network Address Network Address Cooling Demand Level The system cool demand level received over the network. 0 to 3 Heating Demand Level The system heat demand level received over the network. 0 to 3 16 W2W Open

Alarms Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Alarms HOME > ALARM Equipment Alarm Indicates an alarm when any point, which is specified to initiate an Equipment Alarm and energize the Alarm Lamp binary output, is currently in alarm. Default/Range Normal/Alarm Compressor Status Indicates an alarm when any Compressor Alarm is active. Normal/Alarm Compressor 1 Indicates an alarm when the compressor stage 1 commanded output and status feedback input do not match after a 6-minute (not adjustable) time delay. Compressor 2 Indicates an alarm when the compressor stage 2 commanded output and status feedback input do not match after a 6-minute (not adjustable) time delay. Compressor 3 Indicates an alarm when the compressor stage 3 commanded output and status feedback input do not match after a 6-minute (not adjustable) time delay. Normal/Alarm Normal/Alarm Normal/Alarm SPT Sensor Indicates if the SPT space temperature sensor is no longer communicating. Normal/Alarm System T1 Sensor Indicates if the SPT space temperature sensor is no longer communicating. Normal/Alarm Leaving Load Water Temperature Indicates an alarm if the Leaving Load Water Temp falls below the low, or exceeds the high, alarm limits. Leaving Load Water Temperature Sensor Indicates an alarm if the leaving load water temperature sensor fails. Entering Load Water Temperature Indicates an alarm if the Entering Load Water Temp falls below the low, or exceeds the high, alarm limits. Entering Load Water Temperature Sensor Indicates an alarm if the Entering Load Water Temp sensor falls below the low, or exceeds the high, alarm limits. Source Water Temperature Indicates an alarm if the Source Water Temp falls below the minimum, or exceeds the maximum heating or cooling limits. Leaving Source Water Temp Sensor Indicates an alarm if the Leaving Source Water Temp sensor fails. System Entering Source Water Temp Fail Indicates an alarm if the network Entering Source Water Temp sensor fails. Outdoor Air Temperature Indicates an alarm if the outdoor air temperature falls below the low, or exceeds the high, alarm limits. Normal/Alarm Normal/Alarm Normal/Alarm Normal/Alarm Normal/Alarm Normal/Alarm Normal/Alarm Normal/Alarm Outdoor Air Temp Sensor Indicates an alarm if the outdoor air temperature sensor fails. Normal/Alarm Space Relative Humidity Indicates if the relative humidity exceeds the high RH alarm limit. Normal/Alarm Space Relative Humidity Sensor Indicates that a valid space relative humidity sensor or sensor value is no longer available to the controller. Normal/Alarm Condenser Water Linkage Indicates if Condenser Waterside Linkage has failed. Normal/Alarm W2W Open 17

Appendix A: Points/Properties Linkage Navigation: i-vu / Field Assistant: BACview: Properties > Equipment > Linkage Properties > Equipment > Linkage Range Waterside Linkage Waterside Linkage Collector Set the Number of Providers to the total number of controllers in the linked system. When configured, the controller can collect information from other WSHP Open controllers. 1 1 to 64 Waterside Linkage Provider Allows access to configuration of a water linkage system and to the Provider's details. Enter the MS/TP Network Number and MAC Address of the controller that runs the Loop Pump Monitor control program. Network Number Address NOTE If you change the Network Number or Address from a BACview device, you must cycle power to the controller for the changes to take effect. Status If Active, the controller is part of a linked system. If Not Active, the controller is a stand-alone device. Loop Pump Request Set to 1 if this WSHP requires the source water loop to operate. 0/1 0 0 to 65,534 0 0 to 99 Active/Not Active Loop Pump Status The actual state of the source water loop pump(s). Off/On Heat Request Set to 1 if this WSHP is required to operate in a heating mode. 0/1 Cool Request Set to 1 if this WSHP is required to operate in a cooling mode. 0/1 Water Loop Temperature Displays the actual temperature of the source water leaving the plant and entering this WSHP. Outdoor Air Temp Displays the outdoor air temperature being sent to this WSHP through Condenser Water Linkage. A value of -999 F indicates the value is unavailable. -56 to 245 F -999 F -56 to 245 F I/O Points The values shown on the I/O Points Properties page are the raw values at the I/O objects and may not match values shown on status displays that are affected by control program logic. i-vu users logged in as Power User and above are able to edit various parameters associated with the input channels and the display names for all channels. We strongly recommend that you leave these parameters at their defaults. The AppController is not a programmable controller. I/O can only be used for the purpose designed in the equipment control program. Modifying these parameters may result in unpredictable equipment control. See Wiring inputs and outputs for more information. This table lists each of the I/O channels, their functions, associated hardware, and terminal numbers. 18 W2W Open

Navigation: i-vu / Field Assistant: BACview: Properties > I/O Points N/A WARNING! Do not change the Value, Offset/Polarity, Exp:Num, I/O Type, Sensor/Actuator Type, Min/Max, or Resolution I/O configuration parameter for the points listed below. Changing these parameters could cause improper control and/or equipment damage. Use extreme caution if locking a point as this may also cause improper control and/or equipment damage. Zone Temp / Zone Temp (SPT Standard, SPT Plus, SPT Pro, and SPT Pro Plus sensors only). Sensor configurations on the microblock's Properties > Details tab are listed below. For more information, consult the Carrier Sensors Installation Guide. NOTE Do not edit settings on the Zone Temp microblock on the right. Sensor Type: Min Present Value - Minimum present value the sensor transmits before indicating an alarm. -56 to 245 F 45 Max Present Value - Maximum present value the sensor transmits before indicating an alarm. 96 Setpoint Adjustment: Max Adjust The amount that a user may adjust the setpoint at the sensors. Reset setpoint adjust to zero when unoccupied - Resets the setpoint bias to zero when the controller transitions to unoccupied. Timed Local Override: Allow Continuous (SPT Pro only) If checked, a user can press the sensor's local override button until the Max Accum value is reached, then press one more time to have a continuous override until the next occupied period or until the user cancels the override. The display shows On during a continuous override. Each Pulse The amount of time added to the total override time whenever a user pushes the sensor's override button. Max Accum The maximum amount of override time accumulated when a user pushes the sensor's override button. Cancel override How long a user must push the sensor's override button to cancel an override. Sensor Array: Sensor calculation method - When using multiple SPT sensors, select the process variable to be passed to the controller. Off 5 F 0 to 15 F Off Off/On 30:00 mm:ss 0:00 to 1440:00 mm:ss 240:00 mm:ss 0:00 to 2000:00 mm:ss 3 seconds 0 to 60 seconds Avg Avg, Min, Max W2W Open 19

Appendix A: Points/Properties BACnet configuration: Network Visible - Must be enabled for other BACnet objects to read or write to this point, and for this point to generate alarms. d Object Name - Do not change. zone_temp RH Sensor - The current milliamp signal of the controller's RH input. 0 to 20 ma Lvg Source Water Temp The value of the controller's leaving source water temperature sensor input, prior to any operator-configured Calibration Offset. Lvg Load Water Temp The value of the controller's leaving load water temperature sensor input, prior to any operator-configured Calibration Offset. OAT Sensor The value of the controller's outdoor air temperature sensor input, prior to any operator-configured Calibration Offset. Ent Load Water Temp The value of the controller's entering load water temperature sensor input, prior to any operator-configured Calibration Offset. -56 to 245 F -56 to 245 F -56 to 245 F -56 to 245 F Compressor 2 Status The compressor 2 status contact input's current value. Off/On Safety Shutdown Input The safety shutdown input's current value. Normal/Closed Alarm/Open Compressor 1 Status The compressor 1 status contact input's current value. Off/On Compressor 3 Status The compressor 3 status contact input's current value. Off/On Remote Occupancy Contact The remote occupancy contact input's current state. Closed/Open Sensor Invalid This internal input monitors the communication between the controller and the SPT sensor. Off indicates communication is normal. Off/On Load Pump The load pump binary output's current state. Off/On Source Water Pump/Iso Valve The source water isolation valve binary output's current state. Off/On O/B The reversing valve binary output's current state. Off/On Y2 The Y2 (stage 2) valve binary output's current state. Off/On Y1 The Y1 (stage 1) valve binary output's current state. Off/On Y3 The Y3 (stage 3) valve binary output's current state. Off/On Y4 The Y4 (stage 4) valve binary output's current state. Off/On Alarm Lamp The alarm lamp output's current state. Off/On 20 W2W Open

Index Index P Points/Properties Active Compressor Stages 13 Alarm Delay (min/%rh) 8 Alarm Indicator Test 13 Alarm Lamp 18 Allow Continuous 18 BACnet Configuration 18 BAS On/Off 13 Calculated OA Clg Reset 13 Calculated OA Htg Reset 13 Calculated RH Clg Reset 13 Calculated RH Htg Reset 13 Cancel override 18 Changeover Timeguard 13 Chilled Water Supply Setpoint 7 Compressor 1 17 Compressor 1 Status 18 Compressor 2 17 Compressor 2 Status 18 Compressor 3 17 Compressor 3 Status 18 Compressor Alarm 9 Compressor Capacity 4 Compressor Stages 9 Compressor Status 17 Compressor Test 13 Condenser Water Linkage 17 Control Mode Selection 9 Control Point 13 Control Type 9 Cool 5 Cool PID 9 Cool Request 18 Cooling Demand Level 13 Cooling Demand Limit 7 Cooling Lockout Temperature 5 Cooling Setpoint OA Reset 5 Cooling Supply Water Temperature 7 CW Linkage Failure Alarm 9 Demand Level 1 Cool Adj 7 Demand Level 1 Heat Adj 7 Demand Level 2 Cool Adj 7 Demand Level 2 Heat Adj 7 Demand Level 3 Cool Adj 7 Demand Level 3 Heat Adj 7 Demand Limit 7, 13 Each Pulse 18 Effective Cool Setpoint 13 Effective Heat Setpoint 13 Ent Load Water Temp 18 Ent Load Water Temp Alarm 9 Ent Load Wtr Sensor Fail Alarm 9 Ent Load Wtr Temp Sensor Calibration 5 Entering Load Water Temp 4 Entering Load Water Temp Source 13 Entering Load Water Temperature 5, 17 Entering Load Water Temperature Alarm 8 Entering Load Water Temperature Sensor 17 Entering Source Water Temp 4 Entering Source Water Temp Source 13 Entering Water Temp Setpoint 4 Equipment Alarm 4, 17 Equipment Alarm Lamp Output Initiators 9 External T1 Temp 4 Global Occupancy 13 Heat 5 Heat PID 9 Heat Request 18 Heating Demand Level 13 Heating Demand Limit 7 Heating Lockout Temperature 5 Heating Setpoint OA Reset 4 Heating Supply Setpoint Reset 13 High Entering Load Water Temp Alarm Limit 8 High Leaving Load Water Temp Alarm Limit 8 High OAT Alarm Limit 8 High RH Alarm 9 Hot Water Supply Setpoint 7 Isolation Valve Close Delay 9 Isolation Valve Test 13 Isolation Valve Type 9 Leaving CW Sensor 18 Leaving Load Water Temp 4 Leaving Load Water Temp Source 13 Leaving Load Water Temperature 5, 17 Leaving Load Water Temperature Alarm 8 Leaving Load Water Temperature Sensor 17 Leaving Load Wtr Temp Sensor Calibration 5 Leaving Source Temp Sensor Calibration 5 Leaving Source Water Temp 4, 18 Leaving Source Water Temp Sensor 17 Leaving Source Water Temp Source 13 Leaving Source Water Temperature 5 Leaving Water Temp Sensor 18 Leaving Water Temp Setpoint 4 Load Pump 18 Load Water Pump 4 Local Space Temp (T1) Calibration 5 Loop Pump Request 18 Loop Pump Status 18 Low Entering Load Water Temp Alarm Limit 8 Low Leaving Load Water Temp Alarm Limit 8 Low OAT Alarm Limit 8 Lvg Load Water Sensor Fail Alarm 9 Lvg Load Water Temp 18 Lvg Load Water Temp Alarm 9 Lvg Source Water Sensor 18 Lvg Source Water Temp 18 Lvg Source Water Temp Alarm 9 Lvg Source Wtr Sensor Fail Alarm 9 Master Comm Fail Alarm 9 Max Accum 18 Max Adjust 18 Max Present Value 18 Max Source Water Temp Cooling 9 W2W Open 21

Index Max Source Water Temp Heating 9 Maximum OA HW Reset 5 Min Present Value 18 Min Source Water Temp Cooling 9 Min Source Water Temp Heating 9 Network Visible 18 NW Ent Source Water Temp Fail Alarm 9 O/B 18 OA Sensor 17 OA Sensor Failure Alarm 9 OA Temperature Alarm 9 OAT CHW Supply Reset High Limit 5 OAT CHW Supply Reset Low Limit 5 OAT HW S 5 OAT HW Supply Reset Low Limit 5 OAT Sensor 17, 18 Object Name 18 Occ Contact Normal Logic State 9 Occ Relative Humidity Setpoint 7 Occupancy 13 Occupancy Contact 13 Occupancy Schedules 5 Occupancy Status 13 Occupied High RH Alarm Limit 8 Operating Mode 4 Operation Type 9 Outdoor Air Temp 5, 18 Outdoor Air Temp Sensor 17 Outdoor Air Temp Sensor Calibration 5 Outdoor Air Temperature 4, 17 Outdoor Air Temperature Alarm 8 Outdoor Air Temperature Source 13 Power Fail Restart Delay 5 Pump Stop Delay 9 Relative Humidity 7 Relative Humidity Alarm 8 Relative Humidity Source 13 Remote Occupancy Contact 18 Reset 13 Reset Setpoint 18 Reversing Valve 13 Reversing Valve Type 9 RH Cooling Setpoint Reset 5 RH Sensor 18 RH Sensor Fail Alarm 9 Safety Shutdown Input 18 Sensor Array 18 Sensor Calculation Method 18 Sensor Calibration 5 Sensor Invalid 18 Sensor Type 18 Service Test 13 Setpoint Adjustment 18 Shutdown 4 Source Water Pump / Isolation Valve 4 Source Water Pump/ Iso Valve 18 Source Water Temperature 17 Space Relative Humidity 4, 5, 17 Space Relative Humidity Sensor 17 Space RH Sensor Calibration 5 Space Temperature (T1) 5 SPT Sensor 17 SPT Source 13 SPT Temp 4 SPT/T1 Failure Alarm 9 Stage Number of 2nd Compressor 9 Status 18 System Cool Demand Level 13 System Cooling Demand Level 13 System Entering Source Water Temp Fail 17 System Heat Demand Level 13 System Heating Demand Level 13 System Mode 4 System Stage # Assigned to Y1 9 System T1 Sensor 13, 17 Timed Local Override 18 Total Controlled Stages 9 Total System Cmpr Capacity 4 Unit Size - Nominal Capacity 9 Unocc High RH Alarm Limit 8 Water Loop Temperature 18 Water Pump Test 13 Waterside Linkage Collector 18 Waterside Linkage Provider 18 Y1 18 Y2 18 Y3 18 Y4 18 Zone Temp 18 22 W2W Open

CARRIER CORPORATION 2013 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-457-01 3/27/2013