Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments

Similar documents
Vision Protection From Lasers Overview for Dr. Beagley, Australia

A Novel Approach for a Hostile Arms Fire Sensor

Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

REPORT DOCUMENTATION PAGE

Industrial Workshop Gettysburg, PA February 26, 2004

Low Impact Development at Naval Facilities: Opportunities and Constraints

MINIMUM PERFORMANCE REQUIREMENT FOR AIR FORCE FLIGHTLINE FIRE EXTINGUISHERS:

The Conservation Fund The Center for Conservation and Development

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

ECBC SBIR/STTR Projects. ECBC SBIR/STTR MSCoE STRF Conference

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

FIRE PROTECTION FOR. Dist A. MILITARY GROUND VEHICLES. Steve McCormick US Army RDECOM-TARDEC.

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

Design Considerations for Abrasive Blast Rooms & Recovery Systems

Force Protection Joint Experiment (FPJE) Battlefield Anti-Intrusion System (BAIS) Sensors Data Analysis and Filtering Metrics

AFRL-RB-WP-TR

EVALUATION OF FIKE CORPORATION S EXPLOSION SUPPRESSION SYSTEM FOR ULTRA-HIGH SPEED FIRE SUPPRESSION APPLICATIONS

Sustainability Criteria for Planning, Constructing, and Operating Contingency Bases

HANTAVIRUS PREVENTION: CLEANUP OF RODENT CONTAMINATION

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

lighting control systems Division - Name - Date - Language 1

IMPLEMENTATION OF A NOVEL STRUCTURAL HEALTH MANAGEMENT SYSTEM FOR STEEL BRIDGES

REPORT DOCUMENTATION PAGE

BRITE II Characterization and Application to a New Advanced Flight Motion Simulator

Distribution Restriction Statement

A MICROCOMPUTER-BASED LIFE-SAFETY MONITORING SYSTEM FOR ELDERLY PEOPLE

500 Rad Test Cell Radiation Safety Interlock System

Ice Motion Detector System

REPORT DOCUMENTATION PAGE

Autonomous Wide Aperture Cluster for Surveillance (AWACS) WHOI Component

Form DOT F (8-72) Technical Report Documentation Page 2. Government Accession No. 3. Recipient's Catalog No.

MEMORANDUM FOR U.S. Army Developmental Test Command (TEDT-DTC-TMAIC. Pritts), 314 Longs Comer Road, Aberdeen Proving Ground, MD

Distribution Restriction Statement

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Room Temperature MWIR FPAs: Return of the Lead Salts?

PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203

Sensor Grand Challenges: An NVESD Perspective

Laser Use Registration & Application (L.U.R.)

TECHNICAL REPORT NATICK/TR-17/015

MODEL 5100 VOTING LOGIC MODULE

El63 Laser Acceleration at the NLCTA

US Navy Leading the Way in Switchboard Protection

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

February 23, Skanray Technologies Private Limited Yolanda Smith, Consultant Smith Associates 1468 Harwell Ave Crofton, Maryland 21114

Rutgers Environmental Health and Safety (REHS)

PURPOSE OF THE PROCEDURE

Model 4880 Status Output Display Module Manual

TECHNICAL MANUAL OPERATOR S MANUAL FOR MULTIPLE INTEGRATED LASER ENGAGEMENT SYSTEM (MILES) SIMULATOR SYSTEM, FIRING, LASER: M78 NSN

AN10943 Decoding DTMF tones using M3 DSP library FFT function

New API Industry Standards for Shale Development

OPERATING INSTRUCTIONS 2-1 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) 2-5 OPERATOR TROUBLESHOOTING 3-1

STRONG International FP-350 Operation and Installation Manual

Co-60 irradiator for therapy level calibrations at SSDLs

A Comprehensive Review of Market Research on Solar Water Heaters

TM LANDING CRAFT, UTILITY (LCU) BASIC CRAFT UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL MAINTENANCE INSTRUCTIONS

DEPARTMENT OF THE ARMY TECHNICAL MANUAL (FSN ) This copy is a reprint which includes current pages from Changes 1 through 3.

RTO. User guide 05/

TM TO 34W

NAVAL POSTGRADUATE SCHOOL THESIS

EEENE. AD-AIII 4"- AIR FORCE OCCUPATIONAL AND ENVIRONMENTAL HEAL.TH LAS --ETC F/S 13/11 r

DEPARTMENT OF THE ARMY TECHNICAL MANUAL

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

LONGDEN VILLAGE DEVELOPMENT STATEMENT

Town of York Alarm Systems Ordinance

Pavement Evaluation of the Concrete Tie-bars and Dowel Baskets on Irvin Cobb Drive, US 60, McCracken County, KY

SEL Arc-Flash Solutions

CITY OF CHARLOTTESVILLE, VIRGINIA CITY COUNCIL AGENDA

Cable Selection and Detailed Circuit Analysis on Plant under Construction

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

GPS Evaluation Kit EVA1037/1080

SEL Arc-Flash Solutions

rvm4c Installation Guide Remote Video Module

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

U.S. Department of Energy Washington, DC

Microcontroller based design for Tele-sensing and extinguishing fire

Appendix G Response to Comments

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Automated Medication Kit

7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012)

Implementation of Auto Car Washing System Using Two Robotic Arms

Open Source Home Security System

Options for addressing City of Edmonds Alternatives to Ecology s Required Changes addressing Edmonds Marsh Buffers and Setbacks.

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM. Standards Training SANS 369 ORIGINATOR

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

PROJECT BACKGROUND. Preliminary Design Scope and Tasks

Request for Statement of Interest in Implementation of the Roosevelt Road Redevelopment Plan

Request for Proposals (RFP) for: Columbia County Facilities Fire Detection and Security Improvements

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

UCLA Policy 130: Emergency Notifications (BruinAlert) DRAFT FOR PUBLIC REVIEW

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Laser Safety Citations

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Transcription:

ARL-TN-0863 DEC 2017 US Army Research Laboratory Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments by Robert Borys Jr and Colby Adams

NOTICES Disclaimers The findings in this report are not to be construed as an official Department of the Army position unless so designated by other authorized documents. Citation of manufacturer s or trade names does not constitute an official endorsement or approval of the use thereof. Destroy this report when it is no longer needed. Do not return it to the originator.

ARL-TN-0863 DEC 2017 US Army Research Laboratory Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments by Robert Borys Jr Weapons and Materials Research Directorate, ARL Colby Adams Bowhead Total Enterprise Solutions, Belcamp, MD

REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) December 2017 Technical Note 4. TITLE AND SUBTITLE Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments October 2016 September 2017 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Robert Borys Jr and Colby Adams 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) US Army Research Laboratory ATTN: RDRL-WMP-A Aberdeen Proving Ground, MD 21005 8. PERFORMING ORGANIZATION REPORT NUMBER ARL-TN-0863 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR'S ACRONYM(S) 11. SPONSOR/MONITOR'S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT 13. SUPPLEMENTARY NOTES 14. ABSTRACT To safely conduct high-voltage pulsed-power experiments in Experimental Facility 167 (EF 167), the existing firing system needed alterations. The copper firing line of the range provided a current path from the experimental chamber to the control room, posing a risk to operators and equipment. To circumvent this hazard, the copper firing line was replaced by an optical fiber, effectively isolating the control room from electrical hazard. Implementation of the new fiber system used much of the existing resources in EF 167, making this an improvement that can be implemented in any range requiring electrical isolation with a quick turnaround and at low cost. 15. SUBJECT TERMS gun fire system, fiber-optic, electromagnetic, low cost, rebuild 17. LIMITATION 16. SECURITY CLASSIFICATION OF: OF ABSTRACT a. REPORT b. ABSTRACT c. THIS PAGE UU Unclassified Unclassified Unclassified 18. NUMBER OF PAGES 14 19a. NAME OF RESPONSIBLE PERSON Robert Borys Jr 19b. TELEPHONE NUMBER (Include area code) 410-278-2367 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 ii

Contents List of Figures Acknowledgments iv v 1. Background and Introduction 1 2. Objectives for Fiber-Optically Controlled Firing Unit 1 3. Operation of the New Fiber-Optic Firing System 2 4. Conclusion 5 Distribution List 6 iii

List of Figures Fig. 1 Schematic of the EF 167 layout. The copper firing line delineated in red provided the offending current path in the old setup.... 1 Fig. 2 Rear-face view, old (left) and new (right) fire switch and relay box. Note the reduced wiring on the new fire switch and relay box, elimination of finger protection, and elimination of the electric bus bar.... 2 Fig. 3 Front-face view of the new fiber-optic fire switch and relay box... 2 Fig. 4 (Left) Arbitrary waveform generator and red arrow showing the BNCto-fiber converter. (Right) Firing line lock box and red arrow showing the fiber-to-ttl converter with the 300-V control relay.... 3 Fig. 5 The firing line (gray) is shown in the safe position secured at the bottom of the lockout (red arrow). During a test, this will be moved to the firing position on the right side of the box just below the incoming line from the power supply.... 4 Fig. 6 (Left) Expendable cable and relay-to-gun solenoid box located in the experimental chamber room. (Right) Relay-to-gun solenoid box mounted on the concrete wall and the red arrow is pointing to the gun solenoid.... 4 iv

Acknowledgments We would like to acknowledge Dr Matthew Coppinger, Dr Paul Berning, Mr Jeff Ball, Mr Jeff Cameron, and Mr Keith Mahan for providing subject-matter expertise in safe pulsed-power operation. We also thank Mr Steven Davis, SURVICE Engineering, for his assistance in drafting this report. v

INTENTIONALLY LEFT BLANK. vi

1. Background and Introduction After an extensive review from the US Army Research Laboratory (ARL) Electrical Safety Office, it was determined that the existing firing system in Experimental Facility 167 (EF 167) was not adequate to safely perform pulsed-power experiments with gunpowder- or air-driven guns. This firing line used solid copper wire, which provided a continuous electrical conduction path between the highvoltage capacitor in the test chamber and the firing/control room, where personnel are stationed when experiments are performed (Fig. 1). This poses a safety risk since high voltage can travel from the test chamber and potentially result in personnel injuries and damaged equipment. Fig. 1 Schematic of the EF 167 layout. The copper firing line delineated in red provided the offending current path in the old setup. To mitigate this electrical risk hazard, the firing system was refurbished to operate using a fiber-optic line, which would electrically isolate the firing room from the test chamber. Several additional improvements were implemented to lower hazard risk and are described herein. Although these improvements were focused on pulsed-power operation, some should be considered for safe electrical operation for any experiments performed within ARL laboratories. 2. Objectives for Fiber-Optically Controlled Firing Unit The primary objective of refurbishing the firing unit was to electrically isolate the firing room from the test chamber. Doing so required a cost-efficient solution to update the hardware involved in the firing process. With the updated hardware, it becomes necessary then to revisit the procedures used in setup and preparation of the gun for fire. As a means of mitigating cost, much of the old equipment was repurposed for the safer firing module. Changes made to the housing and wiring to simplify the 1

interface of the system are shown in Fig. 2. Since the walls between the control, assembly, and experimental chamber rooms are made of steel, electrically insulating polyvinyl chloride (PVC) through pipes as well as nonconducting cable trays to the firing solenoid were installed and used to thread the fiber-optic lines between the rooms. New equipment was also added to the system including the fiber-optic line with associated converters and an arbitrary waveform generator. Total cost to convert the experimental facility from a copper firing line was approximately $1,000. Fig. 2 Rear-face view, old (left) and new (right) fire switch and relay box. Note the reduced wiring on the new fire switch and relay box, elimination of finger protection, and elimination of the electric bus bar. 3. Operation of the New Fiber-Optic Firing System The new fiber-optic firing system has a similar configuration to the old copper wire system. A single switch initiates the process, which fires the gun. The firing box contains 2 relays with various inputs and outputs, as shown in Fig. 3. Fig. 3 Front-face view of the new fiber-optic fire switch and relay box 2

An interlock system ties a switch from the door between the assembly room and the experimental chamber to the first relay in the firing box. Unless the door to the experimental chamber is closed, the relay in the firing box will remain open to prevent accidental firing. If the interlock switch on the door is engaged, triggering the fire switch closes the second relay in the firing box. When this relay closes, it completes the circuit running from the firing box to the make-screen box. The make-screen box recognizes the completed circuit as a made connection and outputs a 5-V transistor transistor logic (TTL) pulse to the external trigger on the arbitrary waveform generator. Receiving this pulse triggers the waveform generator to output a 5-V pulse for a duration of 1.5 s. The inclusion of the waveform generator is necessary because the output from the make-screen box is of insufficient duration to properly fire the solenoid. The pulse from the waveform generator is fed into a BNC-to-fiber converter and is transmitted via fiber to the experimental chamber room. In the experimental chamber, the fiber is connected to another converter located in a lockout box. It is very important to note that during preparation and experiment the single key to open the otherwise closed lockout box is only retained by the approved gunner. Inside the lockout connected via the BNC-to-fiber converter is a 5 300 V control relay, shown in Fig. 4. When the 1.5-s pulse is applied to the relay, it allows 145 VDC to pass through to the firing solenoid, assuming the firing line is in the armed position. The firing line is kept locked in the box and in the safe position until the experimental chamber is announced to be clear of personnel by the test director, as shown in Fig. 5. Fig. 4 (Left) Arbitrary waveform generator and red arrow showing the BNC-to-fiber converter. (Right) Firing line lock box and red arrow showing the fiber-to-ttl converter with the 300-V control relay. 3

Fig. 5 The firing line (gray) is shown in the safe position secured at the bottom of the lockout (red arrow). During a test, this will be moved to the firing position on the right side of the box just below the incoming line from the power supply. The line from the relay to the solenoid is mostly protected; however, a small portion of the line is exposed to potential damage. This portion of the firing line is sacrificial and made to be easily replaced. A terminal strip mounted to the wall inside a polycarbonate casing provides a quick means to replace the expendable cable after each shot, as shown by the red arrow in Fig. 6. Fig. 6 (Left) Expendable cable and relay-to-gun solenoid box located in the experimental chamber room. (Right) Relay-to-gun solenoid box mounted on the concrete wall and the red arrow is pointing to the gun solenoid. 4

4. Conclusion The implemented changes were an effective solution for reducing hazard risk to the challenges of using the indoor firing range for high-voltage pulsed-power experiments. The new system is just as straightforward to use as before but has the added benefit of electrical isolation for the control room and complying with Army and ARL Electrical and Explosive Safety Standards. Most hardware from the old system was reused as a means of minimizing costs but improving safety. The overall implementations were significant improvements to EF 167 capabilities and directly contributed to the approval of SOP 385-0903, Safe Operation of High Voltage Capacitor Banks up to 280 Kilojoules at ARL Experimental Facility 167. 5

1 DEFENSE TECHNICAL (PDF) INFORMATION CTR DTIC OCA 2 DIR ARL (PDF) IMAL HRA RECORDS MGMT RDRL DCL TECH LIB 1 GOVT PRINTG OFC (PDF) A MALHOTRA 2 DIR ARL (PDF) RDRL WMP A R BORYS C ADAMS 6