Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Similar documents
ENSC 388: Engineering Thermodynamics and Heat Transfer

Journal of Physics: Conference Series. Related content. To cite this article: S Gendebien et al 2012 J. Phys.: Conf. Ser.

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

2. HEAT EXCHANGERS MESA

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Compression of Fins pipe and simple Heat pipe Using CFD

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Flow and heat transfer in a closed loop thermosyphon Part II experiment al simulation

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

THE THERMOSIPHON COOLING SYSTEM OF THE ATLAS EXPERIMENT AT THE CERN LARGE HADRON COLLIDER

Performance investigation of Air-conditioning system using ejector as expansion device

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Steam condensation in a 2D model of an annular gap steam injector

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

To investigate the surface properties for increasing efficiency of solar water heater

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

TMCI Padovan Evaporators

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance of an Improved Household Refrigerator/Freezer

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Performance Study of Triple Concentric Pipe Heat Exchanger

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

An experimental study of the impact of tunnel suppression on tunnel ventilation

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Operation of a Two-Phase Reverse Loop Thermosyphon

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Review of flow-through design in thermoacoustic refrigeration

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Design Evolution: From Rolling Piston to Revolving Vane to Cross-Vane Expandercompressor

Heat Transfer in Evacuated Tubular Solar Collectors

Enhancement of COP in Vapour Compression Refrigeration System

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Thermal Performance of a Loop Thermosyphon

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Simscape Refrigerant Loop Product

*Corresponding author;

COOLING SYSTEM FOR HERMETIC COMPRESSOR BASED ON THE LOOP THERMOSYPHON

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

Modelling the Performance of a Diffusion Absorption Refrigeration System

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Passive cooling of telecommunication outdoor cabinets for mobile base station

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

WL 110 Series. Heat Exchanger with Supply Unit EQUIPMENT FOR ENGINEERING EDUCATION

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Pool boiling heat transfer enhancement on porous surface tube

Adsorption refrigeration system using waste heat

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Jülich Solar Power Tower System Behavior During Downtime

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Numerical study of heat pipe application in heat recovery systems

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

THERMOSYS 4.3. Getting Started Guide

Investigation of Evaporator Performance with and without Liquid Overfeeding

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Transcription:

Journal of Physics: Conference Series Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers To cite this article: M Kessler and S Kabelac 2012 J. Phys.: Conf. Ser. 395 012171 View the article online for updates and enhancements. Related content - Experimental and theoretical analysis of the local condensation heat transfer in a plate heat exchanger V Grabenstein and S Kabelac - Computation of unstable flows using system codes J C Ferreri - Experimental investigation on a decentralized air handling terminal: procedure of aeraulic and thermal performance determination of the entire unit in several operating conditions S Gendebien, L Prieels and V Lemort This content was downloaded from IP address 148.251.232.83 on 13/11/2018 at 05:11

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers M Kessler 1, S Kabelac 2,3 1 Institute for Thermodynamics, Helmut Schmidt University, University of the Federal Armed Forces Hamburg, Germany 2 Institute for Thermodynamics, Leibniz University Hannover, Germany kabelac@ift.uni-hannover.de Abstract. The dynamic thermohydraulic behaviour of a vertical tube reboiler is investigated. Natural circulation reboilers are widely used in chemical industries, especially as column heater. Their main components are an evaporator and a separator which are connected in a loop. The product fluid coming from the separator is heated and partially evaporated. Entering the separator the two-phase flow is separated into liquid and vapour phase, due to gravity. As a result of evaporation the mean density of the fluid decreases. Caused by the density difference between evaporator and separator contents, a natural circulation occurs. Under certain conditions flow instabilities will occur, triggered by different causes. To investigate these instabilities and to distinguish between them as to their type a technical pilot plant scale test facility is used. Its main components are an evaporator, a separator and a condenser. The steam heated evaporator is designed as a straight tube heat exchanger with seven tubes of 4 m length each. By varying various operating parameters such as product vapour pressure, heat load and submergence level stable and unstable conditions can be observed and analysed. Based on the experimental results and criteria found in literature a stability diagram will be developed. 3 Address all correspondence to this author. Published under licence by Ltd 1

1. Introduction Natural circulation reboilers are widely used in chemical industries, especially in rectification processes. As another application thermosyphon reboilers are used for passive cooling in nuclear power plants. Their simple construction, the absence of moving parts and low operating costs are the main reasons for this. When used as a column heater the main components are an evaporator and a separator. Both are connected in a loop. Typically designed as a vertical tube heat exchanger the evaporator is normally heated by condensing steam. Coming from the separator the product liquid fluid is heated and partially evaporated in the evaporator, which results in a difference of the mean density between separator and evaporator. As a result, a self-induced, natural circulation occurs. Natural circulation systems are subject to several types of flow instabilities. The characterisation and classification of flow instabilities in natural circulation systems have been investigated in many studies, especially in the field of nuclear power technology, which are presented in the next section. 2. Principles of instability Under certain conditions flow instabilities are present in natural circulation reboiler systems which cause undesirable flow oscillations. As a result difficulties occur while controlling and operating the reboiler systems. Also mechanical damages to the components caused by vibrations are reported. Due to these issues a stable operating status is of importance. Recent overviews of two-phase flow instabilities can be found in Nayak and Vijayan [1], Kakac and Bon [2] and Goswami and Paruya [3]. A flow is considered to be stable if, following a temporary disturbance, its new operating conditions show an asymptotically tendency to the initial behaviour. Instabilities can be classified according to various bases as follows [1]: - analysis method, - propagation method, - number of unstable zones, - nature of oscillations, - loop geometry, - disturbances or perturbations. With respect to their mechanisms flow instabilities can be classified in two main groups, static and dynamic instabilities, which are both divided in various subgroups [4]. Static instabilities can be predicted by steady-state laws and can lead either to a different steady-state condition or to a periodic oscillating behaviour. The group of static instabilities includes for example flow excursion or Ledinegg instability, flow pattern transition instability, geysering and chugging. Dynamic instability is present when neither the cause nor the threshold of instability can be predicted from the steady-state laws as inertia and feedback effects have an important part. Dynamic instability can be divided in fundamental or pure dynamic instabilities such as acoustic oscillations and density wave oscillations and compound dynamic instabilities as thermal oscillations, BWR instability and parallel channel instability [4]. Density wave instabilities have been investigated experimentally and classified into two types, DWI I and DWI II, by Fukuda and Kobori [5]. Table 1 shows an overview of the various types of flow instabilities. 2

Table 1: Types of flow instabilities. Static instabilities Dynamic instabilities - Ledinegg instability - Acoustic instability - Boiling crisis - Density wave oscillations (I, II) - Geysering - Pressure drop oscillations - Instability due to change in flow regime - Thermal oscillations - Parallel tube instability One aim of this study is to develop a stability diagram as shown in figure 1, where the stable and unstable regions are divided by a stability boundary. Figure 1: Typical stability diagram [4] On the abscissa the heating or the dimensionless phase change number is plotted. On the ordinate you can find the subcooling at the inlet of the evaporator or the dimensionless subcooling number. Both dimensionless numbers are defined in [6]. The desired operating modus of a natural circulation reboiler is marked by region 2, where a steady circulation flow with completed boiling at the exit of the evaporator is present. Geysering, chugging and DWO type I can be assigned to region 1 as an unstable operating status. Region 3 is a second unstable region and mainly characterised by DWO type II. The above mentioned types of instabilities are affected by a variety of geometric and operating parameters which result in various different courses of the stability boundary curve and the characteristic of region 2. Important geometric parameters are the length and diameter of the evaporator tube and its surface quality. As described below the geometry will not be changed during the experiment. As important operating parameters pressure, inlet subcooling, heating power and submergence level are identified [5]. Kumar et al. have carried out various experiments investigating the stability boundaries at various pressures and inlet subcooling [7]. The following section describes the experimental setup used for this study and how the measurements are conducted. 3. Experimental description The test facility built in a technical pilot plant scale stretching over two floors consists of three key parts: the evaporator, the separator and the condenser. All components including the connecting pipes are made of stainless steel. To minimise heat loss, all parts are insulated. 3

Figure 2a: Test facility (ground floor) Figure 2b: Test facility (basement) Fig. 2a and 2b show the test facility on two floors, ground floor and basement. Figure 3: Schematic setup of the test facility Fig. 3 shows the schematic of the test facility. The evaporator is designed as a vertical tube bundle with seven tubes of 4 m length each. Their outer diameter is 30 mm and the wall thickness is 2 mm. 4

Fig. 4 shows a cross section of the evaporator with the adapters for pressure sensors. Superheated steam provided by a natural gas fired boiler is lead into the shell side of the evaporator and condenses at the outer surface of the tubes. Via a pneumatic valve the steam pressure can be varied and controlled. The condensed water leaving the evaporator at the lower side is conducted back to the boiler. The studied product fluid (water) coming from the separator is heated and leaves the evaporator tubes in a two-phase status. Figure 4: Cross section of the evaporator with its adapters for pressure sensors Entering the separator the two phases are separated due to gravity into liquid and gas phase. The vapour phase flows to the condenser passing a demister. The separator consists of a cylindrical vessel with a volume of 0.65 m 3 where the liquid phase of the product is collected. The condenser is built as a straight tube heat exchanger with 110 tubes of 2.5 m length each. The outer diameter is 18 mm and the wall thickness is 1 mm which results in a total heat transfer area of 8.2 m 2. The vapour phase of the product coming from the separator is condensed and flows to the lower part of the separator. Ground water fed by a cooling pond is used as cooling fluid. As an important parameter the pressure on the product vapour side is varied by changing the amount of air inside the loop connecting either a vacuum pump or compressed air. It is additionally controlled by a pressure valve mounted on the condenser shell side. During the experiment different temperatures, pressures and flow rates and the submergence level are measured. For measuring the flow rate of the overheated steam entering the evaporator and the product vapour leaving the separator ultrasonic flow meters, Panametrics GS 868, apply. The metering point of product vapour flow rate named FM3 is shown in fig.3. Their uncertainty increases at low flow velocity up to +10 %. To obtain proper data as well as comparable values of the flow rate of superheated steam, a turbine flow meter is mounted in the condensate pipe with an uncertainty of 1 %. The flow rate of the circulating product at the lower side of the evaporator and the returning subcooled liquid product from the condenser are measured by ultrasonic flow meters, Panametrics UPT 868 P. The metering points named FM1 and FM2 are shown in fig. 3. They have calibrated using an oval wheel counter. Their uncertainty has been determined to be up to 7 %. As this method is contactless no additional pressure drop is introduced. The flow rate of the cooling water is measured by a turbine flow meter with an uncertainty of less than 1.2 %. The wall temperature of each evaporator tube is measured at two levels, 1 and 2 m below the top face of the evaporator, by 14 thermocouples, Type K, soldered at the outer surface of the tubes. At the inlet and outlet of the evaporator the temperature and pressure of the product fluid is measured by thermocouples and absolute pressure sensors. Inlet temperature and pressure of the overheated steam are measured by a thermocouple and an absolute pressure sensor. Its condensate temperature is measured by a thermocouple at its outlet of the evaporator. The thermocouples have an accuracy of 0.1 K. Additionally platinum resistance thermometers PT100 are used for measuring the temperatures 5

of the product vapour leaving the separator and its condensate entering the separator, same for the inlet and outlet temperatures of the cooling water of the condenser and the inlet temperature of product fluid of the evaporator. The platinum resistance thermometers have an accuracy of 0.02 K. The pressure drop across each of the seven evaporator tubes is measured by difference pressure sensors. A bypass level indicator, Kobold NBK-03, is used to measure and display the submergence level in the separator. All measurement outputs are sampled by a NATIONAL INSTRUMENTS data acquisition system NI cdaq-9188. The PC software LabVIEW is used for editing, visualizing and saving the values in a text file for further evaluation. A continuous sampling at various sampling rates ensures the exposure of the dynamic behaviour of the test loop. 3.1 Experimental procedure To indicate their influence on the thermohydraulic behaviour of natural circulation reboilers various operating parameters have been investigated. The pressure on product vapour side at the outlet of the evaporator can be varied in a range between 0.4 and 2.0 bar (abs), which corresponds to saturation temperatures between 75.86 C and 120.21 C. To investigate the influence of the driving temperature difference and the heating power the superheated steam can be conditioned in a pressure range between 3 bar and 7 bar, at a temperature range between 140 C and 190 C. Its mass flow rate is determined by the heat demand of the evaporation in the evaporator tubes. As a further parameter the submergence level as a driving force can be varied between 60 % and 110 % of the evaporator height. To achieve reasonable results especially in terms of heat transfer energy balances of all components are used which are calculated and plotted online by LabVIEW. The uncertainty of heat transfer calculated with measured values is approximately 10 %. 4. Results First experiments have been conducted for testing the system and measurement components. Preliminary results have been generated which are presented here. During these experimental runs only stationary operating states have been investigated. Different pressures on product and heating steam side have been investigated, in which the temperature of heating steam held constant. Table 2: Test matrix with investigated pressure conditions Pressure on product side in bar Pressure on heating steam side in bar 1.0 4, 4.5, 5, 5.5, 6 1.5 4, 4.5, 5, 5.5, 6 2.0 4, 4.5, 5, 5.5, 6 Table 2 shows the test matrix. The various combinations of pressures result in various temperature differences between heating steam and product fluid. Fig. 5 shows preliminary results where the subcooling at evaporator inlet over heat flow is presented at a submergence level of 100 %. It can be observed that, while holding all other parameters constant with increasing product pressure the subcooling decreases. As the temperature difference between heating steam and product increases with a higher pressure of heating steam, the heat flow increases. 6

T in K 16 15 14 13 12 11 10 9 8 7 150 200 250 300 350 400 Q in kw p_product = 1 bar p_product= 1,5 bar p_product = 2 bar Figure 5: Subcooling at evaporator inlet over heat flow at three different product pressure levels at stationary conditions. The subcooling also shows a slightly increase with growing heating steam pressure. At these conditions no oscillations have been observed. Hence these parameter configurations can be assigned to region 2 in fig. 1. 4 3,5 3 m_product in kg/s 2,5 2 1,5 p_product = 1 bar p_product= 1,5 bar p_product = 2 bar 1 0 50 100 time in sec Figure 6: Circulating mass flow rate in kg/s over time in seconds at three different product pressure levels. As shown in fig. 6, where the circulating mass flow rate in kg/s is presented over the time in seconds, an increasing pressure on the product side results in increasing circulating mass flow at constant heating steam conditions as temperature and pressure. A reason for this could be that caused by the higher temperature difference a higher heat transfer coefficient is present, which results in a higher steam quality and two-phase pressure drop due to friction and hence a decrease in circulating mass flow rate. The observed oscillations are in a range of max. +/- 25 % in case of p_product = 2 bar. As an indication of instability some authors report amplitudes of 30 % of the mean value. 7

Fig. 7 shows the steam quality ( ) and mass flow rate (+) presented over heat flow. It can be observed that, as mentioned before, with increasing heat flow the steam quality x increases and the mass flow decreases. steam quality x 0,1 0,08 0,06 0,04 0,02 0 150 200 250 300 350 400 Q in kw 4 3 2 1 0 m in kg/s Figure 7: Steam quality x at evaporator outlet and mass flow rate over heat flow at stationary conditions. 5. Conclusion To investigate the stability of natural circulation reboilers a technical pilot plant scale test facility has been built. First experimental runs have been conducted to evaluate the measurement system. In the course of these experiments only stationary conditions have been investigated. Preliminary results of these tests are presented. In upcoming experiments the dynamic behaviour of natural circulation reboilers will be investigated to find criteria for indication of stability. On base of these tests a stability diagram can be developed as shown in fig.1. Furthermore tests under instationary conditions will be conducted in detail to explore the principles of flow instabilities, the nature of oscillations and their propagation. In an additional step a simulation model will be developed to evaluate the experimental results. References [1] Nayak A K and Vijayan P K 2008 Flow instabilities in boiling two-phase natural circulation systems: A review Science and Technology of Nuclear Installations Volume 2008 ID 573192 [2] Kakac S and Bon B 2008 A review of two-phase flow dynamic instabilities in tube boiling systems International Journal of Heat and Mass Transfer 51 (3-4) 399-433 [3] Goswami N and Paruya S 2011 Advances on the research on nonlinear phenomena in boiling Progress Nuclear Science 53 673-697 [4] Boure J A, Bergles A E and Tong L S 1973 Review of two-phase flow Nuclear Engineering and Design 25 pp 165-192 [5] Fukuda K and Kobori T 1979 Classification of two-phase flow instability by density wave oscillation model Journal of Nuclear Science and Technology 16 (2) pp 95-108 [6] Baars A 2003 Stationäre und instationäre Betriebszustände eines Naturumlaufverdampfers Fortschritt-Berichte VDI Reihe 3 Verfahrenstechnik 779 [7] Kumar P, Khardekar A, and Iyer K 2012 Experimental and numerical investigation on a twophase natural circulation test facility Heat transfer engineering 33(9) pp 775-785 8