Overview EUSDSG3.11. Maintain gas fired ducted air heaters and appliances

Similar documents
Gas Emergency Response

SKAC228 (SQA Unit Code - FA51 04) Maintain site security

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Understand and apply domestic central heating system installation and maintenance techniques

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

LANH4 - SQA Unit Code H52T 04 Co-ordinate the collection and storage of propagation material

IMIMC06 Diagnose and rectify motorcycle electrical faults

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Domestic Gas Cookers & Ranges

Level 3 Diplomas in Domestic Heating ( /42/43) Candidate logbook/workplace evidence record

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

LANH54S SQA Unit Code H53B 04 Identify, collect and prepare plants for sale or dispatch

LANAHL19 - SQA Unit Code AT63 04 Create grassed and planted areas

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

LANH49 SQA Unit Code H Design landscape areas and specify materials and components

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

SEMPEO SQA Unit Code H02H 04 Wiring electrical equipment and circuits

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

FIRE RISK ASSESSMENT Self Assessment

Title: Room-sealed fanned draught flue systems concealed within voids

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

SUMET09 Maintain electrical systems and equipment (SQA Unit Code- H956 04)

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

HHIC consumer guide to gas boiler servicing

A6VS VENTILATION STANDARDS

F I R E S A F E T Y R E G I S T E R

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

Fire risk management plan. MH/05/Revised/06/17

LANH7 SQA Unit Code H53L 04 Propagate plants from seed

The Gas Safety (Installations and Use) Regulations 1998.

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Statutory Compliance Checklist

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Electrical Safety Policy and Management System

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

You will be able to carry out the following activities: use firefighting tools in an appropriate and competent manner

SUMET05 Install and connect electrical cables, conductors, wiring systems and equipment

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Eligibility criteria

Plumbing, Heating & Gas Industry Course Information

Fire Safety Policy (Communal Areas)

HOUSING (STANDARDS FOR RENTED HOUSES) REGULATIONS 2017

Millfield Schools Fire Risk Prevention Policy

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

Overview SFSSLP6. Maintain the security of property and premises through observation

Dovre 250 Cast Iron Gas Stove

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

Greenstar 12i/24i System

Fire Risk Assessment 2017

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Barnsley Accredited Landlord Scheme Accredited Property Registration Form

Wellsprings Primary School. Fire Emergency Evacuation Plan

If there are more than ten people working other than on the ground floor,

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Technical Bulletin 005(B) Developed with Building Standards Scotland

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

NOTTINGHAM CITY HOMES

Church Heating. Diocese of St Albans Diocesan Advisory Committee Advisory Leaflet 47

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

St Edward s Oxford FIRE SAFETY POLICY

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Australian/New Zealand Standard

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Decorative Fuel Effect Appliances

ESSENTIAL INSTALLATIONS

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Consumer unit replacement in domestic and similar premises

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Fire Safety Strategy

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Fire Risk Management Policy. UK September 2017

REGULATED QUALIFICATIONS FRAMEWORK (RQF)

Renovation Program. Renovation Program GENERAL

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS

Level 3 Diploma in Gas Engineering ( )

Lakanal House inquest: Statement from the Fire Sector Federation

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Course outline: 442 Capstone G105A UEENEEG105A - Verify compliance and functionality of low voltage general electrical installations

OFTEC s role in promoting safe domestic oil storage

Transcription:

Overview This national occupational standard is for gas engineers who are required to maintain domestic gas fired ducted air heaters and includes the following range of appliances: Down-flow, Up-flow, Horizontal-flow and Slot-fit warm air central heating units. This standard covers the work activities of planning, maintaining, de-commissioning and commissioning those appliances. EUSDSG3.11 1

Performance criteria You must be able to: Plan and prepare work activities for maintaining gas fired ducted air heaters 1. Identify, record and agree the customer s job requirements in line with statutory requirements 2. Survey the work site and consult site diagrams as necessary for any key structural features and existing defects that could affect the installation and record them, advising property occupier of any defects found 3. Produce a risk assessment and method statement which incorporates safety provisions in the work site, access to the work site, movement of the workforce, members of the public, and the movement and safe storage of materials, tools and equipment for the job 4. Protect the work site and the building fabric against possible damage being caused during the de-commissioning and maintenance process 5. Check and confirm all materials, tools and equipment necessary for the de-commissioning, maintenance and commissioning process are available as required and are fit for purpose 6. Check and confirm that the siting of the appliance meets the manufacturers and industry standards requirements for location, siting and clearances 7. Check the existing duct system of the appliance to ensure it meets manufacturers and industry standards requirements 8. Confirm that the gas supply, electricity supply, the chimney suitability and the provision of ventilation meet the appliance manufacturers and industry standards requirements for the installation 9. Carry out all necessary checks and tests to confirm the gas supply, electricity supply, the chimney system and the existing warm air and return air ducts meet the manufacturers and industry requirements for the installation 10. Check location of condensate disposal is in compliance with appliance manufacturers and industry standards requirements, as necessary 11. Check existing installation for any unsafe appliances and system components and apply the gas industry unsafe situations procedures as required De-commission gas fired ducted air heaters to industry standards and manufacturers instructions 12. Check that conditions within the gas and electricity systems will permit safe de-commissioning EUSDSG3.11 2

13. Select and use the correct tools and equipment for decommissioning activities 14. Use designated safe isolation methods, tests, and procedures to de-commission gas and electricity systems and components 15. Take precautionary actions to ensure that temporarily decommissioned appliances, systems, or components do not present a safety hazard 16. Permanently remove and disconnect appliances, gas system components and electricity system components as required Maintain gas fired ducted air heaters to industry standards and manufacturers instructions 17. Carry out preparatory work to meet the maintenance requirements set out in the plan 18. Remove existing gas and electricity system components as required by the planned maintenance activities 19. Carry out the maintenance process in accordance with manufacturers specification and industry standards, taking care to minimise damage 20. Select and use the correct tools and equipment for maintenance work activities 21. Re-position the appliance and confirm it meets the location, siting and clearances required by the manufacturers and industry standards specification 22. Confirm existing ventilation for appliances and system meets industry requirements for the installation 23. Ensure existing gas systems are clean and free of debris 24. Re-connect gas and electricity system components to the appliance 25. Use tightness testing and purging procedures and electrical testing to confirm the integrity of the re-connected and re-installed system and appliance 26. Use industry standard checks and testing procedures to confirm the integrity of the existing chimney system and appliance flue seals Pre-commission and Commission gas fired ducted air heaters to industry standards and manufacturers instructions 27. Confirm the complete appliance installation complies with the EUSDSG3.11 3

manufacturers specification, industry standards, Gas Safety (Installation & Use) Regulations, British Standards and Building Regulations 28. Check that conditions within the gas and electricity systems will permit safe commissioning 29. Select and use the correct tools and equipment for commissioning activities 30. Check and confirm: a) the gas system operating pressures meet industry standards b) the appliance operating pressure and the gas rate meet industry standards and manufacturers requirements 31. Check the combustion performance visually and by flue gas analysis as required 32. Test chimney performance and reconfirm it performs according to manufacturers and industry standards requirement s 33. Reconfirm that the ventilation requirements meet industry standards for the installation 34. Reconfirm that the location of condensate disposal is in compliance with appliance manufacturers and industry standards requirements, as necessary 35. Check and confirm the operation of the gas appliance, the systems and components to ensure they function safely and operate in accordance with manufacturers instructions 36. Instruct the property occupier on the correct operation of the appliance and gas system and provide them with their copy of the appliance literature 37. Take precautionary actions to prevent the unauthorised use of uncommissioned gas appliances, gas systems, electrical systems and components by isolation procedures and use of warning notices Use and communicate data and information to carry out decommissioning, maintenance and commissioning work 38. Liaise with the property occupier and other people who will be affected by the work during the planning, de-commissioning, maintenance, and re-commissioning processes to minimise disturbance to the job 39. Use normative documents, industry standards, British Standards and information from manufacturers instructions for the appliance to ensure the work is done to the specification 40. Advise of any delays to the work, unsafe situations and required remedial actions to those who require the information EUSDSG3.11 4

41. Check that the customer is satisfied with the finished job 42. Complete records and documentation confirming the safe maintenance of gas appliances, systems and 43. Complete gas appliance and gas system commissioning and decommissioning records as required and ensure they are stored securely Resolve problems within own area of responsibility and competence which could affect the de-commissioning, maintenance and commissioning process 44. Rectify problems within own area of responsibility and competence and report deficiencies in gas and electric input services 45. Resolve problems in accordance with approved procedures when: a) pre-maintenance checks and tests reveal gas appliance, gas system or component defects b) gas appliances, gas systems and components being commissioned do not meet design requirements c) the gas appliance, the gas system or component cannot be restored to full performance EUSDSG3.11 5

Knowledge and understanding You need to know and understand: General Knowledge 1. Regulations and guidance governing health and safety in the workplace, environmental protection and the use of risk assessments 2. Legislation covering the general responsibilities of the operative for their own safety and that of others 3. The limits of your own autonomy and responsibility De-commissioning, maintaining and commissioning warm air central heating 4. The health, safety and environmental factors which need to be incorporated in risk assessment for the domestic maintenance process 5. Safe access and working at heights 6. The tools and equipment necessary to provide safe access to work at heights, or in confined spaces 7. The methods of working which protect the building décor, customer property and existing systems and components 8. The care and maintenance requirements of tools and equipment, and checks for safe condition 9. The tools, equipment, materials and components required for the gas appliance and gas system de-commission, maintenance and commission ordering, supplying, advising, checking and delivery procedures 10. How to safely secure and store tools, equipment, materials and components to minimise loss or wastage 11. The potential hazards that could arise from all de-commissioning, maintenance and commissioning activities and the checks to be carried out before work takes place 12. The steps to take should materials, components, tools and equipment not be available at the site to commence the decommissioning, maintenance and commissioning activity 13. How to access and correctly interpret the required information, including normative documents, industry standards guidance documents, British Standards and manufacturers instructions applicable to the appliance, to ensure the work is done to the specification and industry standards 14. How to confirm that the gas supply, electric supply, chimney system and ventilation requirements are adequate for existing gas appliances, systems, or components EUSDSG3.11 6

15. How to confirm that the existing duct system is adequate for the warm air central heating appliance, system and components 16. Safe isolation methods, tests, and procedures to de-commission gas and electricity systems or components 17. The procedures for temporary and permanent de-commissioning of appliances and systems including use of temporary continuity bonds 18. The precautions to ensure that de-commissioned appliances or systems do not prove a safety hazard 19. Measures to prevent de-commissioned appliances or systems being brought into operation utilising safety and warning notices 20. The need to liaise with others whose procedures or routines may be affected by the suspension of the gas appliance and gas system operation 21. The points in the de-commissioning, maintenance and recommissioning process where co-operation and liaison with other trades and property occupier may be required 22. Types of warm air central heating appliances to ensure correct heater selection; downflow, upflow, horizontal flow, & slot-fit 23. The industry practices and work standards for fabricating and installing warm air central heating gas appliances, systems and components to comply with the manufacturers specification, industry standards, Gas Safety (Installation & Use) Regulations, British Standards and Building Regulations 24. The positioning and fixing requirements for warm air central heating gas appliances, systems and components to comply with the manufacturers specification, industry standards, Gas Safety (Installation & Use) Regulations, British Standards and Building Regulations 25. The positioning and fixing requirements for warm air central heating appliances, systems and components in; airing cupboards, compartments, roof spaces, slot-fit and under stairs installations in order to comply with the manufacturers and industry standards requirements 26. The positioning and fixing requirements for the installation of; warm air ducting, return air ducting, plenums, plenum adaptors, transfer grilles, registers & grilles 27. The industry practices and work standards for connecting to input services including; gas, electric, ventilation and chimney systems, including natural & fanned air supply 28. The industry practices and work standards for connecting warm air central heating gas appliances and components to both new and EUSDSG3.11 7

existing gas, electric, ventilation and chimney systems 29. The industry practices and manufacturers requirements for the positioning and the installation of condensate drain for condensing warm air units 30. The process and procedures, equipment and legislative requirements for applying tightness testing and purging to appliances, gas systems and components 31. The process and procedures, equipment and legislative requirements for applying electrical tests to appliances, systems and components to ensure safe functioning 32. The routines and sequences of the maintenance process of warm air central heating domestic gas appliances, gas systems and components in accordance with manufacturers specification and industry standards 33. The routines and sequences for re-commissioning warm air central heating domestic gas appliances, gas systems and components in accordance with manufacturers specification and industry standards 34. The procedures for checking the correct operation and performance of warm air central heating gas appliances, gas systems and components and checking against the design specification 35. The procedures for checking the correct operation and performance of warm air central heating gas appliances, gas systems and components to ensure safe functioning 36. The procedures for checking and confirming a) the gas system operating pressures b) the appliance operating pressure and the gas rate 37. The tests, checks and use of flue gas analysers which confirm the suitability of the gas combustion performance 38. The tests and checks to confirm the integrity, suitability and performance of the systems 39. How to complete all maintenance documentation and records to be left with the property occupier Measures to prevent un-commissioned gas systems being brought into operation utilising safety and warning notices 40. The system handover procedures and demonstrating the operation of replacement systems and components to end users 41. The steps to take when problems arise in the work activities 42. Job management structures and methods of reporting and recording job progress or problems delaying progress 43. How to safely collect and dispose of system contents that may be hazardous to health or the environments EUSDSG3.11 8

44. How to isolate unsafe gas appliances, gas systems and components and application of the gas industry unsafe situations procedure EUSDSG3.11 9

Glossary Cookers refers to Freestanding, Built In, Slide Under, Hotplates, Grilles, Range Cookers, and Dual Fuel Cookers Leisure Appliances refers to Greenhouse Heaters, BBQ s, Patio Heaters, Gas Flambeaux, and Outdoor Gas Lighting Gas fired ducted air heaters refers to Basic Warm Air Units and Combined Warm Air Units these incorporate a Gas Circulator Storage Water Heater. They may be configured as Down-flow, Up-flow, Horizontal-flow and Slot-fit and will include Open, Room-Sealed, and Fan Draught Chimneys Work Site refers to the area where the work will take place and all areas affected by the works Services and Systems refers to water, central heating, gas, electricity supply, condensate disposal, chimneys and ventilation systems EUSDSG3.11 10

Developed by Energy & Utility Skills Version Number 2 Date Approved December 2017 Indicative Review Date Validity Status Originating Organisation December 2021 Current Original Energy & Utility Skills Original URN DSG 3.11 Relevant Occupations Suite Keywords Engineering; Science and Engineering Technicians Down Stream Gas maintain, maintenance, warm air, central heating, heating systems, utility, utilities EUSDSG3.11 11