MARTIN Insertable Dust Collector

Similar documents
ACT Cartridge Dust Collector

Unimaster Dust Collector UMA 40, 70, 100, 150 and 250 Built After August 2005 UMA 450 and 750 Buiilt After March 2006

MN908 No. 282C Replaces 282B LB7013

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

ENERVEX RSV CHIMNEY FAN

MODELS 304GC, 304GCX, 314GC, and 314GCX

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Control Panel For Water Wash Hoods AM2

LBX-2000 POWER STRAPPING MACHINE

BLAST-IT-ALL BUMPER BLASTER

Installation & Operation Manual For ENERGENICS In-Line Space Saver Lint Filters

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Installation and Operation Manual

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

MODELS ASHP, ASHH, ASUP, and ASUH

Delta P Control. Installation and Operation Manual. Installation, Operation, and Service Information. English Master Language

M Series Fan Filter Units

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

CLe-series Dishwashers

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

Page 1 of 18. Part# /5/2013

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Safety Message to Installers of Federal Signal Siren Speakers

Installation & Maintenance Instructions

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

55-Gallon Dispenser Package

R E D I C O N T R O L S

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

MODEL CDB8 INSTALLATION INSTRUCTIONS

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

Ceiling Mount Air Purification System

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F

5.0 Installation Instructions

Installation Instructions Part No , Part No Part No

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Dual Column Dehydrating Breather Manual

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

Insulated Ventilators. Operating Instructions & Parts Manual

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

SPEAKMAN SPEAKMAN SPECIFICATIONS

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

DBF 4XL Dryer Booster Fans

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

PowerVac G Single to Twin Conversion Kit [ ]

Quest Power Electric Heat EHS 31 Pro

ATKINSON DYNAMICS SPEAKERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

TJERNLUND PRODUCTS, INC.

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

55-Gallon Dispenser Package

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

ED200/250 KSTYLE LID KITS

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

ST. KITTS CEILING FAN

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

690 Power Fishing System

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Models: GW/R-T GW/R-2-T GW/R-3-T

Delta P Plus Control

Panel Fan Series Operators Manual (Galvanized and Polymer)

1 HP Air Mover. Owner s Manual

Delta P Plus Control

V SERIES HDR GAS RANGES

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Torit Radial Blade Fan TRB-1 to 10 (60 and 50 Cycle)

Quartz H 2 OT SHOT TM. Infrared Inline Chemical Heater

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

PORT700CF Portable Fume Collector

User Manual Box Exhaust Fan Series (Belt Drive)

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Installation Instructions

918 Clock Gauge Installation, Operation, and Maintenance Instructions

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

HB CDA SERIES WITH TEMPERATURE SETBACK

L A signature series TA T N E RE O, A L L A T S IN

Panel Fan Series Operators Manual (Galvanized and Polymer)

Installation Instructions

Installation Instructions

Transcription:

MARTIN Insertable Dust Collector Go to MARTIN Insertable Dust Collector web page Operator s Manual M3416

Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF THE MATERIAL; USER S FAILURE TO INSPECT, MAINTAIN AND TAKE REASONABLE CARE OF THE EQUIPMENT; INJURIES OR DAMAGE RESULTING FROM USE OR APPLICATION OF THIS PRODUCT CONTRARY TO INSTRUCTIONS AND SPECIFICATIONS CONTAINED HEREIN. MARTIN ENGINEERING S LIABILITY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF EQUIPMENT SHOWN TO BE DEFECTIVE. Observe all safety rules given herein along with owner and Government standards and regulations. Know and understand lockout/tagout procedures as defined by American National Standards Institute (ANSI) z244.1-1982, American National Standard for Personnel Protection - Lockout/Tagout of Energy Sources - Minimum Safety Requirements and Occupational Safety and Health Administration (OSHA) Federal Register, Part IV, 29 CFR Part 1910, Control of Hazardous Energy Source (Lockout/Tagout); Final Rule. The following symbols may be used in this manual: DANGER Danger: Immediate hazards that will result in severe personal injury or death. WARNING Warning: Hazards or unsafe practices that could result in personal injury. CAUTION Caution: Hazards or unsafe practices that could result in product or property damages. IMPORTANT Important: Instructions that must be followed to ensure proper installation/operation of equipment. NOTE Note: General statements to assist the reader.

Table of Contents Section Page List of Figures............................................................ ii Introduction.............................................................. 1 General...................................................................... 1 Location requirements for transfer point installations.................................. 1 References................................................................... 1 Safety....................................................................... 2 Materials required............................................................. 2 Before Installing Dust Collector.............................................. 3 Installing Dust Collector.................................................... 4 Electrical connections.......................................................... 8 Installing timer enclosure........................................................ 9 Initial Operation of Dust Collector............................................ 11 Maintenance.............................................................. 12 Part Numbers............................................................. 13 Table of Contents Martin Engineering M3416-10/11 i MARTIN Insertable Dust Collector

List of Figures & Tables List of Figures Figure Title Page 1 Dimensions for MARTIN Insertable Dust Collector, P/N INS-08XX and INS-10XX...................................... 4 2 Dimensions for MARTIN Insertable Dust Collector, P/N INS-15XX........ 5 3 Dimensions for MARTIN Insertable Dust Collector, P/N INS-18XX and INS-20XX...................................... 6 4 Dimensions for MARTIN Insertable Dust Collector, P/N INS-30XX........ 7 5 Electrical and Plumbing Detail....................................... 8 6 Solenoid Enclosure................................................ 9 7 Solenoid Wiring Schematic......................................... 9 8 Timer Enclosure Electrical Connections................................ 10 List of Tables Table Title Page I Preventative Maintenance Schedule................................... 12 II MARTIN Insertable Dust Collector Part Numbers...................... 13 III MARTIN Insertable Dust Collector Part Numbers...................... 13 IV CPV PowerCore DC Manual Kit Part Numbers........................ 14 V MARTIN Insertable Dust Collector Part Numbers and Weights............ 14 Martin Engineering M3416-10/11 ii MARTIN Insertable Dust Collector

Introduction General Location requirements for transfer point installations References The MARTIN Insertable Dust Collector is an automatic, reverse air dust filter designed to remove dust from the air in conveyor transfer points, silo vents, bucket elevators, and screens. The unit is made up of a group of filter elements mounted on a sealed frame. The elements are fitted side-by-side in an individual sealing arrangement that effectively separates the dirty (inlet) side of the filter from the clean (outlet) side. The elements are always removed for maintenance from the clean side of the filter. This manual provides instructions for locating and installing the MARTIN Insertable Dust Collector at a conveyor transfer point or silo. For instructions on installing units on bucket elevators or screens, call Martin Engineering or a representative. Information on unit components, assembly, electrical requirements, operation, maintenance, and troubleshooting can be found in the user manual supplied with your unit. To ensure the dust collector s maximum effectiveness, make sure the transfer point is properly sealed and designed with dust control in mind, as follows: Chute length: For standard materials or belt speeds up to 250 fpm (1.3 m/s), the transfer point chute length should equal 2 ft per 100 fpm (210 mm per 0.5 m/s) of belt speed. For very dusty materials or belt speeds of 300 fpm (1.5 m/s) and higher, the chute length should equal 3 ft per 100 fpm (914 mm per 0.5 m/s) of belt speed. When in doubt, make the chute longer. Chute height: For standard materials or belt speeds up to 250 fpm (1.3 m/s), the chute wall should be at least 12 in. (305 mm) high. For very dusty materials or belt speeds of 300 fpm (1.5 m/s) and higher, it should be at least 24 in. (610 mm) high. Distance from load zone: Locate dust collector as far from actual load zone as possible, and 1/3 of the chute length back from the chute exit point. For best results, install a dust curtain at the exit of the chute. For information on transfer point wear liners and sealing systems, call Martin Engineering or a representative. The following documents are referenced in this manual: American National Standards Institute (ANSI) z244.1-1982, American National Standard for Personnel Protection - Lockout/Tagout of Energy Sources - Minimum Safety Requirements, American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018. Federal Register, Volume 54, Number 169, Part IV, 29 CFR Part 1910, Control of Hazardous Energy Source (Lockout/Tagout); Final Rule, Department of Labor, Occupational Safety and Health Administration (OSHA), 32nd Floor, Room 3244, 230 South Dearborn Street, Chicago, IL 60604. Donaldson Torit Preventative Maintenance Schedule for DF, DFT, DFO, TD, HP, PJ, DLMC, Unicell, Maxcell Dust Collectors, Donaldson Company, Inc., June 2003. Introduction Torit PowerCore is a registered trademark of Donaldson Company, Inc. Martin Engineering M3416-10/11 1 MARTIN Insertable Dust Collector

Introduction Safety Materials required All safety rules defined in the above documents and all owner/employer safety rules must be strictly followed when working on this equipment. In addition to standard hand tools, a hoist is required to install this equipment. Martin Engineering M3416-10/11 2 MARTIN Insertable Dust Collector

Before Installing Dust Collector IMPORTANT The delivery service is responsible for damage occurring in transit. Martin Engineering CANNOT enter claims for damages. Contact your transportation agent for more information. 1. Inspect shipping container for damage. Report damage to delivery service immediately and fill out delivery service s claim form. Keep any damaged goods subject to examination. 2. Remove dust collector from shipping container. Equipment in container should include dust collector and controller. 3. If anything is missing, contact Martin Engineering or representative. Before Installation WARNING Before installing equipment, turn off and lock out/tag out energy source to conveyor and conveyor accessories. 4. Turn off and lock out/tag out energy source according to ANSI standards (see References ). WARNING If equipment will be installed in an enclosed area, gas level or dust content must be tested before using a cutting torch or welding. Using a cutting torch or welding in an area with gas or dust may cause an explosion. 5. If using a cutting torch or welding, test atmosphere for gas level or dust content. Cover conveyor belt with fire retardant cover. Martin Engineering M3416-10/11 3 MARTIN Insertable Dust Collector

Installation Installing Dust Collector 1. Make sure conveyor belt structure and chutework will support dust collector. See Table V for weight specifications. 2. Determine how to best install dust collector on your application. See Figures 1 4 for dimensions. 3. Follow instructions in the included installation manual to install dust collector. Figure 1. Dimensions for MARTIN Insertable Dust Collector, P/N INS-08XX and INS-10XX Martin Engineering M3416-10/11 4 MARTIN Insertable Dust Collector

Installation Figure 2. Dimensions for MARTIN Insertable Dust Collector, P/N INS-15XX Martin Engineering M3416-10/11 5 MARTIN Insertable Dust Collector

Installation Figure 3. Dimensions for MARTIN Insertable Dust Collector, P/N INS-18XX and INS-20XX Martin Engineering M3416-10/11 6 MARTIN Insertable Dust Collector

Installation Figure 4. Dimensions for MARTIN Insertable Dust Collector, P/N INS-30XX Martin Engineering M3416-10/11 7 MARTIN Insertable Dust Collector

Installation Motor Power Supply Wires* Electrical Power Supply* Timer Enclosure Motor Starter* Timer 120V Power Supply Wires* Control Wires* Filter-Regulator Unit Compressed Air Supply* (80-100 PSI) Air Supply Line* Lockout Valve Figure 5. Electrical and Plumbing Detail *Indicates components are supplied by customer Electrical connections WARNING All electrical work must be done to National Electrical Code (NEC) standards. See References. DANGER For explosion-proof dust collector units, properly ground unit to earth by connecting a ground wire to the earthing boss on the unit. Failure to properly ground the unit can result in a static electricity explosion, damage to equipment, and severe injury or death. 1. For explosion-proof units with INS-XE part numbers, properly connect a ground wire to the unit s earthing boss (located on the unit next to the symbol shown below) to prevent static electricity buildup. Use the brass screw provided to connect the ground wire to the unit. WARNING Before making any connections, lock out/tag out electrical supply to control system according to ANSI standards (see References ). 2. Connect blower motor to power supply: a. Determine power requirements for motor (see Table III). b. Install a motor starter (not included) per local requirements and codes. c. Interlock motor and timer enclosure and control per plant PLC. Martin Engineering M3416-10/11 8 MARTIN Insertable Dust Collector

Installing timer enclosure CAUTION Do not mount enclosure in area subject to shock, vibration, temperatures exceeding 130 F (55 C), or explosion. Damage to control system circuitry could result. 1. Determine location for timer enclosure. 2. Mount onto wall with fasteners. 3. Drill conduit holes in enclosure for solenoid and power wires. Use care not to damage internal components. Drill in most weather-proof location available on enclosure. Installation B A C D C D A. Screws B. Solenoid Enclosure Cover C. Solenoid Terminal (Line) D. Solenoid Terminal (Neutral) Figure 6. Solenoid Enclosure 4. Loosen screws (A) and remove solenoid enclosure cover (B). Solenoid Enclosure SOL 1 SOL 2 Factory Wired Wired at Installation SOL 3 SOL 4 SOL 5 SOL 6 COM L1 L2 COM 1 2 3 4 56 Timer Enclosure Terminal Block Figure 7. Solenoid Wiring Schematic Martin Engineering M3416-10/11 9 MARTIN Insertable Dust Collector

Installation 5. Using electrical connectors, route required wires from solenoid valves to timer enclosure. Connect wires to solenoid terminals. 6. Reinstall solenoid enclosure cover (B, Figure 6). L1 L2 Com Solenoids Figure 8. Timer Enclosure Electrical Connections 7. Route power wire (120VAC 60Hz) into timer enclosure. 8. Connect ground wire to ground terminal. Connect neutral wire to terminal labeled L2. Connect phase wire to terminal labeled L1. 9. Reinstall timer enclosure cover. Martin Engineering M3416-10/11 10 MARTIN Insertable Dust Collector

Initial Operation of Dust Collector IMPORTANT Read entire section before beginning work. Operation WARNING Dust collector may produce loud noise when mounted on structure. See OSHA 1910.95 for guidelines. If required, wear ear protection to avoid impairment or loss of hearing. 1. If dust collector produces loud noise according to OSHA 1910.95, wear ear protection. WARNING Failure to remove tools from installation area and conveyor belt before turning on energy source can cause serious injury to personnel and damage to belt. 2. Remove all tools and fire retardant cover from installation area and conveyor belt. DANGER Do not touch or go near conveyor belt or conveyor accessories when conveyor belt is running. Body or clothing can get caught and pull body into conveyor belt, causing severe injury or death. 3. Turn power ON at the source. 4. Start blower fan for one second, then stop. 5. Check motor and fan for the correct rotation by referencing the rotation sticker located on the motor mounting plate. Check for smooth operations of fan wheel and motor. If motor is not rotating in correct direction, lock out/tag out energy source and reverse rotation. 6. Ensure damper is set in completely closed position. 7. Turn compressed air on at the source. Adjust the regulator until pressure is between 90 and 100 PSI (6.2 6.8 Bar). 8. Turn conveyor belt ON and ensure material is flowing. 9. Turn the blower fan ON. 10. Open the damper 50% while the dust collector is under dust load. 11. Operate dust collector for 5 to 10 minutes. 12. Open the damper until the transfer point is under a negative air flow. 13. Operate and maintain dust collector according to user manual supplied with your unit. Martin Engineering M3416-10/11 11 MARTIN Insertable Dust Collector

Maintenance Maintenance Table I. Preventative Maintenance Schedule Item Frequency Procedure Monitor Exhaust of Fan to ensure filter integrity. Collector Filter Pressure Drop Filter Pressure Drop Pneumatic Lines Compressed Air Supply Pulse Diaphragms Electrical Solenoids Verify conditions of Filters Verify operations of Pulse Cleaning System Check fan and motor Adjust exhaust Damper as needed Install filters correctly Adjust exhaust Damper Daily Weekly Monthly Monthly Every 3 Months Every 3 Months Every 6 Months Every 6 Months Every 6 Months Every 6 Months During filter changes Immediately after filter changes Monitor exhaust from fan. The exhaust should remain visibly clean. If a leak of dust develops, it will be noticed as a visual puff from the fan exhaust immediately after a cleaning pulse. If dust is visible consult your Installation and Operation Manual for troubleshooting recommendations. Visually inspect and record the operating pressure drop across each dust collector. It is normal for the pressure drop to fluctuate during operation as the collector passes through cleaning cycles, and as production schedules fluctuate from light to heavy. New filters may have a pressure drop of less than 1 w.g., however, as filters become seasoned, they will reach an equilibrium pressure drop. Generally 1 to 6 w.g. is considered normal. An excessively high pressure drop could be an indication of a malfunction in the cleaning mechanism, excessive airflow, plugged filters, or heavy dust loading conditions. Consult your Installation and Operation Manual for troubleshooting recommendations. To ensure correct pressure drop indication, remove one line at a time from the pressure drop indicating gauge barb fitting. Using a minimum 20 psi compressed air, blow through the line back towards the dust collector. (Do not use more than 25 psi to blow through clear poly tubing as damage may occur.) Air dryers and automatic condense valve should be used prior to each dust collector. Inspect monthly to ensure proper operation, and that moisture is being removed from the compressed air supply. Troubleshoot, repair, or replace per the specific manufactures instructions. Consult your Installation and Operation Manual for correct pulse pressure recommendations for the dust collector. Apply electrical and pneumatic service to the pulse cleaning control. Activate the pulse cleaning sequence by placing the control in continuous cleaning mode. Approximately every ten (10) seconds an audible pulse should be heard. This process should be performed simultaneously with the solenoid check described below. Apply electrical and pneumatic service to the pulse cleaning control. Activate the pulse cleaning sequence by placing the control in continuous cleaning mode. Approximately every ten (10) seconds an audible pulse should be heard. Additionally, each solenoid should be inspected manually by placing a large flat, light-weight surface (cloth) behind each solenoid enclosure. As each solenoid is activated, in that particular enclosure, visually inspect the test surface for movement. (When the solenoid is energized, compressed air is released from the diaphragm valves through the solenoid.) If filter element pressure drop exceeds 6 w.g. verify proper system airflow according to original design recommendations. Remember that excessive airflow can increase pressures drop. Change filters if necessary. Always use Donaldson superior filters for best performance and life. Inspect Diaphragms, Solenoids and Timer to ensure proper filter cleaning. Consult the Installation and Operation Manual for your dust collector for the correct On and Off time settings for Pulse cleaning intervals and duration. Check motor and fan for the correct rotation by referencing the rotation sticker located on the motor mounting plate. Check for smooth operations of fan wheel and motor. Inspect for and tighten belts, nuts, bolts and set screws as needed. Consult the Installation and Operation Manual for troubleshooting recommendations as needed. Airflow should be adjusted to match design recommendations. Excessive airflow can shorten filter life and cause fan motor failure. Consult the Installation and Operation Manual for recommendations to correctly install new filters. Install new filters correctly and adequately tightened to prevent dust leakage. Improperly installed or inadequately tightened filters can allow dust to pass through the dust collector. Because the pressure drop or restriction to airflow through the filters will decrease when new filters are installed, airflow through the collector will increase. Because of this it is necessary to adjust the fan damper to restrict the airflow through the collector to the recommended level immediately after installation of new filters. As the filters age and the pressure drop or restrictions to air increases, you may need to open the damper to reach design conditions. Martin Engineering M3416-10/11 12 MARTIN Insertable Dust Collector

Part Numbers See the following tables for MARTIN Insertable Dust Collector unit assembly part numbers. For replacement filter elements, manifold valves, and solenoid valves, call Martin Engineering at 800-544-2947. Table II. MARTIN Insertable Dust Collector Part Numbers Item Description Part Number Quantity 1 CPV PowerCore Dust Collector Table III 1 2 TRB Fan Pack Table III 1 3 CPV PowerCore DC Manual Kit 38435-K (See Table IV) 1 4 Adapter Flange Weldment Table III 1 5 Hardware Kit Table III 1 Part Numbers Part No. Table III. MARTIN Insertable Dust Collector Part Numbers Airflow CFM Voltage P/N Item 1 P/N Item 2 P/N Item 4 P/N Item 5 INS-084 0-800 460V 60Hz 38432-2 38433-2 38627-CPV-2 38627-2H INS-084E 0-800 460V 60Hz 38432-2E 38433-2E 38627-CPV-2 38627-2H INS-084EH 0-800 460V 60Hz 38432-2EH 38433-2E 38627-CPV-2 38627-2H INS-103 0-1000 380V 50Hz 38432-2 38434-3-38050 38627-CPV-2 38627-2H INS-104 800-1000 460V 60Hz 38432-2 38433-3 38627-CPV-2 38627-2H INS-104E 800-1000 460V 60Hz 38432-2E 38433-3E 38627-CPV-2 38627-2H INS-104EH 800-1000 460V 60Hz 38432-2EH 38433-3E 38627-CPV-2 38627-2H INS-153 1000-1500 380V 50Hz 38432-3 38434-3-38050 38627-CPV-3 38627-3H INS-154 1000-1500 460V 60Hz 38432-3 38433-3 38627-CPV-3 38627-3H INS-154E 1000-1500 460V 60Hz 38432-3E 38433-3E 38627-CPV-3 38627-3H INS-154EH 1000-1500 460V 60Hz 38432-3EH 38433-3E 38627-CPV-3 38627-3H INS-184 1500-1800 460V 60Hz 38432-4 38434-3 38627-CPV-4 38627-4H INS-184E 1500-1800 460V 60Hz 38432-4E 38434-3E 38627-CPV-4 38627-4H INS-184EH 1500-1800 460V 60Hz 38432-4EH 38434-3E 38627-CPV-4 38627-4H INS-203 1500-2000 380V 50Hz 38432-4 38434-5-38050 38627-CPV-4 38627-4H INS-204 1800-2000 460V 60Hz 38432-4 38433-5 38627-CPV-4 38627-4H INS-204E 1800-2000 460V 60Hz 38432-4E 38433-5E 38627-CPV-4 38627-4H INS-204EH 1800-2000 460V 60Hz 38432-4EH 38433-5E 38627-CPV-4 38627-4H INS-303 2000-3000 380V 50Hz 38432-6 38434-7.5-38050 38627-CPV-6 38627-6H INS-304 2000-3000 460V 60Hz 38432-6 38434-5 38627-CPV-6 38627-6H INS-304E 2000-3000 460V 60Hz 38432-6E 38434-5E 38627-CPV-6 38627-6H INS-304EH 2000-3000 460V 60Hz 38432-6EH 38434-5E 38627-CPV-6 38627-6H Martin Engineering M3416-10/11 13 MARTIN Insertable Dust Collector

Part Numbers Table IV. CPV Powercore DC Manual Kit Part Numbers Item Description Part Number Quantity 1 Nipple Hex 1-NPT 36009 5 2 Union 1-NPT Galvanized 36274 2 3 Valve Ball Safety Shutoff 1 NPT 32284-04 2 4 Gauge Air GLYSRL Fill 1/4-NPT 160 PSI 34842 1 5 Filter/Regulator 1-NPT 38736 1 6 Operator s Manual M3416 1 Table V. MARTIN Insertable Dust Collector Part Numbers and Weights Part No. MARTIN Insertable Dust Collector* DCE Model No. Weight lb (kg) Adapter Flange P/N 38432-2 CPV-2 320 (145) 38627-CPV-2 38432-3 CPV-3 400 (181) 38627-CPV-3 38432-4 CPV-4 500 (227) 38627-CPV-4 38432-6 CPV-6 655 (297) 38627-CPV-6 Part No. Dust Collector Motor* Power hp Weight lb (kg) 38433-2 2 63 (29) 38433-3 3 87 (39) 38433-5 5 124 (56) 38434-3 3 155 (70) 38434-5 5 178 (81) * For explosive environments, add an E to end of dust collector and motor part numbers. Martin Engineering M3416-10/11 14 MARTIN Insertable Dust Collector

Any product, process, or technology described here may be the subject of intellectual property rights reserved by Martin Engineering Company. Trademarks or service marks designated with the symbol are registered with the U.S. Patent and Trademark Office and may be proprietary in one or more countries or regions. Other trademarks and service marks belonging to Martin Engineering Company in the United States and/or other countries or regions may be designated with the TM and SM symbols. Brands, trademarks, and names of other parties, who may or may not be affiliated with, connected to, or endorsed by Martin Engineering Company, are identified wherever possible. Additional information regarding Martin Engineering Company s intellectual property can be obtained at www.martin-eng.com/trademarks.

Martin Engineering USA One Martin Place Neponset, IL 61345-9766 USA 800 544 2947 or 309 852 2384 Fax 800 814 1553 www.martin-eng.com Subject to change without prior notice. Quality Management System Certified by DNV - ISO 9001 Form No. M3416-10/11 Martin Engineering Company 1998, 2011