DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Similar documents
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK

ST1. Mod. USE AND MAINTENANCE MANUAL

DOL 31 Speed Controller Technical User Guide

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Instructions for the fan motor control system, SILVER C

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MC 31 Speed Controller Technical User Guide Code no GB

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

Instructions for the fan motor control system with integrated wiring terminals SILVER C

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

GB User and maintenance manual

IMPORTANT SAFETY INFORMATION

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

CONTROL PANELS for 2 Q2P series ELECTRIC PUMPS

ENGLISH Par W COB UV

03.03.mmm REV.2 09/01

Swaging Machine Type H50-46ECO

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

3-way switching valve

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Original operating instructions Safety switch with guard locking AC901S AC902S

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

USER MANUAL ACQUAHOME 32 B BLU

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

NRB100. Installation and Programming Manual INSTALLATION NRB100 AND PROGRAMMING MANUAL

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Table of Content LT 5165-UL

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

PROCESSING UNIT II V Hz V Hz. Table of Contents

Installation and Operating Manual

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

SYMS III MANUAL SEALER

SACE PR021/K SIGNALLING UNIT

SYMS II MANUAL SEALER

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

SCHMIDT LED Measured Value Display MD Instructions for Use

DOC JAN06 LT 200

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

EW 40 Wireless Fan Control

ENGLISH Floodlight LED 50W

Instruction manual. Remote control electric IR HEATER

User and maintenance manual

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Drying Ovens for Fluxes Models F100 F200 - F400

General safety precautions English

E-COMBI EVO E-SYSTEM EVO

VADA - Rain2Main Automatic Rainwater Controller

User Guide. OPTYMA TM Control Three-phase AK-RC 103

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation, Operating and Maintenance Manual

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

1. Information before installation General terms of delivery, storage and transport

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

CTA15-2 warming drawer. operating and installation instructions

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

Sensor Control Panel

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

MURELLE EV HE 25/55-30/55

Heat Pump Defrost Board Replacement Kit

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Drying Ovens Models F3 - F6 - F9

ENGLISH Parcan 16 GU10D socket V1

Instructions for installation and use English. More documents on: H B /09

USERS MANUAL FOR GAS BOILERS

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

ELECTRIC BOILERS FOR CENTRAL HEATING

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

DIGITAL ALARM UNIT Model ALU-AP

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

Product waste disposal - Protection of the environment:

ENGLISH StageBeam 650/1000W Fresnel V1

Model 76 Dehumidifier Control Installation Instructions

TECHNICAL MANUAL BlowerPack fan unit

Panel Mounted Heat Exchangers by Dantherm, Inc.

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Instructions For Use ENG. LED Magnifier Lamp

en Inverter FU 4/5. Operator s Manual

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Transcription:

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. CONTROL PANEL... 9 5.1 Luminous indicators and control commands... 9 6. KEY TO FUNCTIONS AND SETTINGS... 10 6.1 Main display items... 10 6.2 Activation of load in manual mode... 10 6.3 User programming in automatic mode... 11 7. ALARMS... 15 8. ASSISTANCE MENU PARAMETERS... 16 9. STANDARD CIRCUIT DIAGRAMS... 17 9.1 DRYTEK 1 Single phase circuit diagram... 17 9.2 DRYTEK 1 Three phase circuit diagram... 18 10. STANDARD WIRING DIAGRAMS... 19 10.1 DRYTEK 1 Single phase wiring diagram... 19 10.2 DRYTEK 1 Three phase wiring diagram... 19 11. STANDARD DIMENSIONAL DIAGRAM... 20 11.1 DRYTEK 1 Single phase dimensional... 20 11.2 DRYTEK 1 Three phase dimensional... 20 12. TROUBLESHOOTING... 21 13. GENERAL CONDITIONS... 22 13.1 Warranty... 22 13.2 Maintenance... 22 13.3 Disposal... 22 14. DECLARATION OF CONFORMITY... 23 III

IV

1. INTRODUCTION This manual must always accompany the relevant equipment and be conserved in an accessible location for consultation by qualified technicians assigned for operation and maintenance of the system. The installer/user is strongly recommended to carefully read all instructions and information in this manual before using the product, in order to avoid damage or improper use of the unit, which would also render the warranty null and void. Before operating the equipment, carefully read the manual and follow all instructions provided. The information and instructions in this manual refer to the standard use of this product; in the event of special circumstances, functions or applications not described in this document, contact our service center for assistance. If technical assistance or spare parts are required, when contacting the manufacturer always specify the identification code of the model and construction number as stated on the data plate. Our service center is available for any requirement or clarification. On receipt of the goods, inspect immediately to ensure that the equipment has not been damaged during transport. If defects are found, the client should promptly notify our retailer within 5 days of receiving the goods, or in the event of direct purchases, the Elentek service center. N.B. the information provided in this manual is subject to modifications without notice. The manufacturer shall not be held liable for any damage caused in relation to the use of these instructions, as they are to be considered guideline only. Note that failure to observe the instructions provided in this manual may cause physical injury or damage to objects. In any event all local and/or current legislation must be observed at all times. 5

2. WARNINGS The electrical panel must be used exclusively for the purpose and function as specified in design. Any other application or use is to be considered improper and therefore hazardous. In the event of a fire in the place of installation or the surrounding area, avoid the use of water jets and use the appropriate extinguishing equipment and means (powder, foam, carbon dioxide). Install the equipment far from heat sources and in a dry and sheltered location in observance of the stated protection rating (IP). The installation of a safety device is recommended to protect the panel power line in compliance with current electrical standards. The electrical panel must be connected by a qualified electrician in observance of the relevant electrical standards. No parts of the panel must be disassembled without the official authorization of Elentek: any tampering with or modifications to the unit will render all terms of the warranty null and void. All installation and/or maintenance operations must be performed by a specialized technician who is fully aware of the relevant current safety standards. Ensure the installation is connected to an efficient earthing system. After making the electrical connection, check that all electrical panel settings are correct to avoid automatic start-up of the electric pump. Elentek declines all liability in the event of the following: - Incorrect installation; - Use by personnel not adequately trained in the correct use of the panel; - Serious failure to perform scheduled maintenance; - Use of non-original spare parts or parts not specific to the model; - Unauthorized modifications or interventions; - Partial or total failure to observe instructions. 6

3. GENERAL DESCRIPTION Power supply 1 ~ 50/60Hz 230V±15% (DRYTEK 1-Single); Power supply 3 ~ 50/60Hz 400V±15% (DRYTEK 1-Three); C/I1 normally open input for start-up command; Buttons for function selection and programming; Buttons AUTOMATIC-0-MANUAL (spring return); Display for values: Volts, Amperes, Cos ϕ of motor and alarms; Green led: motor active; Adjustable electronic motor overload control; Motor control on 2 phases; Motor current overload protection (adjustable); Protection of sequence/phase Protection of minimum/maximum voltage (adjustable); Protection against dry running (adjustable power factor); Automatic reset from dry running status with 4 separate programmable times, from 0 to 240 minutes (also possible cyclical); Protection of aux. circuits and motor with fuses; Alarm output (NC-C-NO resistive load - 5A / 250V); Door lock general disconnect switch; Provision for start-up capacitor for single-phase (not included); Box in ABS, IP55; Ambient temperature: -5/+40 C; Relative humidity 50% at 40 C (condensate free). 7

4. INSTALLATION Ensure that the mains power supply specifications correspond to the voltage specified on the data plate of the electrical panel and motor connected, then make the earthing connection before all other connections. DRYTEK 1 Mono 1~230V ± 15% 50/60Hz DRYTEK 1 Tri 3~400V ± 15% 50/60Hz The power line must be protected by a residual current circuit breaker. Tighten the electrical cables on the relative terminals using a suitable tool correctly sized to avoid the risk of damage to the fixing screws. Take care if using an electric screwdriver. The electrical panel is designed for wall-mounting using screws and plugs in the pre-drilled holes at the corners of the enclosure, or by means of brackets when present. Install the equipment in areas compliant with the protection rating and ensure that the box is kept intact when drilling the holes for fitting the cable clamps. Avoid the use of multicore cables where there are wires connected to inductive loads and power cables and signal cables such as sensors and digital inputs. Keep connection cables as short as possible, preventing any twisting of cables which may be harmful due to inductive effects on the electronic equipment. All wires used in the cabling must be suitably sized to withstand the load to be powered. 8

5. CONTROL PANEL 5.1 Luminous indicators and control commands The DRYTEK 1 electrical panel has been designed for the adjustable protection of 1 motor with dry running safety control, obtained from the power factor (where fi is the timing angle between current and voltage), without the need for external commands (float or pressure switch). N.B. The load is activated or deactivated on closure or opening of the normally open contact C/I1. If no float or pressure switch is used, a jumper must be wired in on input C/I1. KEY TO LUMINOUS INDICATORS AND COMMANDS 230V 0.0A 1.00ϕ MAN ( ) AUT (*) Display of values and programming Green led: electric pump operating SETUP (or multifunction) button UP arrow button DOWN arrow button OK button 9

6. KEY TO FUNCTIONS AND SETTINGS 6.1 Main display items On activation of the DRYTEK 1 panel, the display shows the following: ELECTRIC PUMP DRYTEK v 2.0 E L E N T E K www.elentek.com MODEL 50HZ M/2.2 At the end of the start-up sequence, the main menu is displayed, as described below. 230V 0.0A 1.00ϕ MAN ( ) AUT (*) This screen enables display of the electrical data as read by the DRYTEK 1 panel in real time: 230 V = Power supply voltage reading; 0.0 A = Current absorbed by connected load; 1.00 ϕ = Power factor of connected load; MAN () = Panel set to manual mode; AUT () = Panel set to automatic mode; 6.2 Activation of load in manual mode On activation the panel always starts up in Automatic mode, indicated by the asterisk () displayed alongside the text AUT on display. The operating mode can be changed by pressing the UP arrow to change to Manual mode, or the DOWN arrow to change to Automatic mode. Therefore, to enable operation in Manual mode, press the UP arrow (the asterisk () is displayed alongside the text MAN) and then press and hold OK. The display then displays current absorption of the motor and the power factor values in real time; the green led also lights up to indicate the electric pump is running. On release of the OK button, the motor is shut down. N.B. in manual mode, the load is activated and bypasses all alarms, but in the event of a fault the display flashes, and the user can press the DOWN arrow to view a description of the alarm. 10

6.3 User programming in automatic mode To access the user programming menu, press and hold the SETUP button until the first parameter settings menu is displayed (minimum power factor). Practical examples: 1 Protection against dry run by motor cos φ. 2 Float ON-OFF. 3 Pressure switch ON-OFF. 11

6.3.1 MINIMUM 0.80 ϕ MINIMUM POWER FACTOR (COS-FI) COS-FI To go to the next window, press OK. On access to the menu, the first window enables modifications to the minimum power factor value, below which the load is deactivated due to dry running conditions (use the arrows to modify the value). EXAMPLE: To enable operation in manual mode, activate in no-load conditions (dry running), check the power factor reading (e.g. 0.65) and enter the minimum power factor, increasing it by approx. 0.05. MINIMUM 0.70 ϕ COS-FI 6.3.2 MAXIMUM CURRENT MAXIMUM CURRENT 5.7 A To go to the next window, press OK. The second screen enables modifications to the maximum motor current value, above which it is shut off due to current overload (use the arrows to change the value). EXAMPLE: To enable operation in manual mode, read the load current value displayed (e.g. 6.0 Ampere) and check that this corresponds to the motor data plate specifications. Enter the maximum current value, increasing it by 10-15% with respect to the previously checked value. MAXIMUM CURRENT 6.9 A 12

6.3.3 RESET In the event of a dry running alarm (minimum power factor) the panel may attempt to reset automatically, which can be programmable in minutes, with the option of setting this function as sequential. RESET N. 1 TIME 5 MIN RESET N. 2 TIME 10 MIN RESET N. 3 TIME 20 MIN RESET N.4 TIME 30 MIN 4 reset times can be set, in which the system automatically restarts after being blocked; By default these values are set as shown alongside: The first reset attempt is performed 5 minutes after the dry running alarm. The second reset attempt is performed 10 minutes after the alarm. The third reset attempt is performed 20 minutes after the alarm. The fourth reset attempt is performed 30 minutes after the alarm. N.B. On each reset screen, use the arrows to modify any set times and press OK to go to the next screen. After setting all times, press OK to go to the screen for the reset cycle settings. CYCLE RESET ( 0 ) NO ( 1 ) YES?: 1 If the value 0 (zero) is set, all automatic resets are blocked after the fourth attempt; if the value is set to 1 (one) at the end of the fourth attempt, the reset cycle is repeated continuously; The system protecting the panel against dry running conditions activates the reset cycle according to the time intervals set, and resumes the same reset cycle each time water is detected for more than 10 seconds. To exit the menu, press SETUP. 13

6.3.4 SUMMARY SETUP TABLE DESCRIZIONE PARAMETRO VALORE DEFAULT MAXIMUM CURRENT This parameter enables entry of the maximum current for each motor. Enter the maximum current value, increasing it by 10-15% with respect to the rated motor value. Modifications to operating limits beyond the parameters stated on the model data plate will immediately render the warranty null and void. MINIMUM COS-PHI This parameter establishes the minimum Cos-Phi power factor value for each motor Enable operation in manual mode, activate in no-load conditions (dry running), check the power factor reading (e.g. 0.65) and enter the minimum power factor, increasing it by approx. 0.05. 1 - A - 0.15-1.00 - AUTOMATIC RESET ON DRY RUNNING ALARM In the event of a dry running alarm (minimum power factor) the panel may attempt to reset automatically, which can be programmable in minutes. 4 reset times can be set, in which the system automatically restarts after being blocked; By default these values are set as shown below: The first reset attempt is performed 5 minutes after the dry running alarm. The second reset attempt is performed 10 minutes after the alarm. The third reset attempt is performed 20 minutes after the alarm. The fourth reset attempt is performed 30 minutes after the alarm. SEQUENTIAL RESET ON DRY RUNNING ALARM If the value 0 (zero) is set, all automatic resets are blocked after the fourth attempt; if the value is set to 1 (one) at the end of the fourth attempt, the reset cycle is repeated continuously; The system protecting the panel against dry running conditions activates the reset cycle according to the time intervals set, and resumes the same reset cycle each time water is detected for more than 10 seconds. 1-240 Min Y or N 1 5 Min 2 10 Min 3 20 Min 4 30 Min Y DISPLAY BRIGHTNESS ON STANDBY This parameter enables entry of the brightness setting applied when the display sets to standby (wait 9 seconds for a preview). TIME FOR ENTRY TO SET-UP This parameter enables entry of the time to keep the SETUP button pressed for access to the set-up menu. 0-9 4 2-30 Sec 3 Sec 14

7. ALARMS ALARM MOTOR DRY RUNNING The measured power factor value is the set value and the panel shuts down the relative pump. The display blink and the cumulative alarm output is activated (voltage-free contacts NC-C-NO). The system resets automatically on the basis of the times set during programming, or manually by pressing the button SETUP until the screen is displayed without flashing, after which the button OK can be pressed to reset. ALARM MOTOR IN PROTECTION The load current absorption is higher than the set value and the panel shuts down the relative pump. The display blink and the cumulative alarm output is activated (voltage-free contacts NC-C-NO). The system is reset manually by pressing the button SETUP until the screen is displayed without flashing, after which the button OK can be pressed to reset. ALARM VOLTAGE TOO LOW The measured mains voltage is too low (the pumps are shut down). The display blink and the cumulative alarm output is activated (voltage-free contacts NC-C-NO). The system automatically resets every 60 seconds or manually by pressing the OK button. ALARM VOLTAGE TOO HIGH The measured mains voltage is too high (the pumps are shut down). The display blink and the cumulative alarm output is activated (voltage-free contacts NC-C-NO). The system automatically resets every 60 seconds or manually by pressing the OK button. ALARM SEQUENCE OR LACK PHASES The phase sequence is incorrect or one or more phases is missing (the pumps are shut down). The display blink and the cumulative alarm output is activated (voltage-free contacts NC-C-NO). The system is reset manually turning off and on the electrical panel after reconnecting the phases correctly. 15

8. ASSISTANCE MENU PARAMETERS This menu is accessed by simultaneously pressing the buttons SETUP and OK during activation of the panel. This menu enables modifications to the language, minimum and maximum voltage, with the latter programmed by default as shown in the table below (modify only if absolutely necessary). IF YOU CHANGE THE OPERATING LIMITS, BEYOND THE DEFAULT PARAMETERS, WILL RESULT IN IMMEDIATE FORFEITURE OF THE GUARANTEE. Press OK to go to the next screen. DESCRIPTION OF PARAMETER LANGUAGE ITALIAN / ENGLISH / FRENCH / SPANISH / GERMAN MINIMUM VOLTAGE Single-phase voltage rated 230-15% Three-phase voltage rated 400-15% MAXIMUM VOLTAGE Single-phase voltage rated 230-15% Three-phase voltage rated 400-15% COS-PHI ALARM OUTPUT This parameter enables removal of the dry running alarm. VALUE ENGLISH 195 V 340 V 264 V 460 V Y or N N.B. On each screen, use the arrows to modify any set values and press OK to go to the next screen. To exit the menu, press SETUP. 16

9. STANDARD CIRCUIT DIAGRAMS 9.1 DRYTEK 1 Single phase circuit diagram 17

9.2 DRYTEK 1 Three phase circuit diagram 18

10. STANDARD WIRING DIAGRAMS 10.1 DRYTEK 1 Single phase wiring diagram 10.2 DRYTEK 1 Three phase wiring diagram 19

11. STANDARD DIMENSIONAL DIAGRAM 11.1 DRYTEK 1 Single phase dimensional 11.2 DRYTEK 1 Three phase dimensional 20

12. TROUBLESHOOTING 1. 2. 3. 4. 6. PROBLEM THE PANEL IS SET TO AUTOMATIC MODE BUT THE PUMP DOES NOT START. ON PUMP START-UP, THE PANEL SETS TO ALARM STATUS "ALARM MOTOR PROTECTION TRIP. ON PUMP START-UP, THE PANEL SETS TO ALARM STATUS "ALARM MOTOR DRY RUN" ON PUMP START-UP, THE PANEL SETS TO ALARM STATUS "ALARM VOLTAGE TOO HIGH AND ALARM VOLTAGE TOO LOW. THE DISPLAY DOES NOT SWITCH ON. CHECKS/SOLUTIONS Ensure that a jumper is wired in on input G/P, if a float or pressure switch is not connected. Ensure correct operation of the float or pressure switch connected to the input G/P. Check the maximum current settings in the user menu (see page 12). Ensure correct operation of the motor used. Check the minimum power factor settings in the user menu (see page 12). On the 230V~ single phase model, check to ensure correct sizing of the start-up capacitor. On the 400V~ three phase model, check correct sequence of the motor phase wiring. Ensure that the input voltage on the electrical panel is adequate. Check the input voltage on the electrical panel and set the correct minimum and maximum voltage values in the assistance menu (see page 16). Ensure that the FLAT cable is connected correctly. Ensure that the FLAT cable has not been damaged. 21

13. GENERAL CONDITIONS 13.1 Warranty The product warranty is subject to the general terms of sale of the company Elentek S.r.l. Acknowledgement of the warranty depends on the strict and proven observance of the operating instructions in this booklet and application of the correct mechanical, hydraulic and electro-technical practices. All products are covered by a warranty valid for 12 months, which covers all construction defects of our products and includes the replacement/repairs of defective parts. The warranty will not be deemed valid in the event of: - tampering with the panel (modifications without prior authorization); - faults due to lack of or inadequate protection and/or connection errors; - faults caused by exceeding data plate specifications; - normal wear and tear of the panel; - failure by installation personnel to observe the specified operating procedures; - accidental causes, natural disasters of any kind, such as fires, flooding, water or lightning; The defective material must be delivered carriage paid to Elentek S.r.l., who reserves the right to final judgement of the cause of the said defects. The Warranty applies exclusively to restoring the original product characteristics and does not cover material damage or physical injury. 13.2 Maintenance DRYTEK 1 does not require routine maintenance provided that it is used within the operating limits and in observance of the instructions in this manual. Special maintenance or repairs must be performed exclusively by authorized service centers. In the event of repairs, only original spare parts must be used. The manufacturer declines all liability for material damage or injury to persons or animals caused by maintenance interventions performed by unauthorized personnel or using non-original materials. 13.3 Disposal In the event of disassembly and scrapping, strictly observe local legislation regarding pollution. Waste disposal according to material categories is recommended. 22

14. DECLARATION OF CONFORMITY ELENTEK Srl with registered offices in via A. Meucci, 5/11-35028 Piove di Sacco (PD) ITALIA, declares under its sole responsibility that the machine: DRYTEK series installed and used in the ways and for the purposes described in the operation and instruction manual complies with the provisions of the EU directives and relative amendments: European Directive 2014/35 UE Electromagnetic Compatibility 2014/30 UE and subsequent amendments, in compliance with the following technical standards: EN 61439-1 EN 55014-1 EN 61000-3-2 EN 61000-3-3 Piove di Sacco, 01.02.2016 LEGAL REPRESENTATIVE Michele Borgato 23

NOTES 24

NOTES 25

NOTES 26

ELENTEK SRL SOCIETÀ UNIPERSONALE Via A. Meucci 5/11-35028 Piove di Sacco (PD) - ITALIA Tel. +39 049 9730367 - Fax +39 049 9731063 www.elentek.com - info@elentek.com P.IVA 04534630282 Cod. MQ 0003 UK Rev. 01 Em. 11.2016