Linear Current Sensors

Similar documents
Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

HOA6480 Series Barcode Sensor Infrared Products

HIH-4602-L Series Humidity Sensors


Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

HIH-5030/5031 Series Low Voltage Humidity Sensors

FEATURES AND BENEFITS

FSS-SMT Series. Low Profile Force Sensor

HIH-4000 Series Humidity Sensors

Micropower Omnipolar Digital Hall-Effect Sensor ICs

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Potential Applications

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

V-Basic Standard V15 Series

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

MICRO SWITCH GLL Series

High Temperature Industrial VRS Magnetic Speed Sensors

HFX Fiber Optic Component 50 Mbps, 650 nm LED

General Purpose Industrial VRS Magnetic Speed Sensors

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

MICRO SWITCH GSX Series

Interactive Catalog Replaces Catalog Pages

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

WARNING MISUSE OF DOCUMENTATION

MICRO SWITCH V15W Series Watertight Miniature Switches

HIH-4030/31 Series Humidity Sensors

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

HIH-4010/4020/4021 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Wireless Panel-Mount Monitor

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Installation Instructions for the 600 Series Optical Encoders

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Interactive Catalog Replaces Catalog Pages

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Airflow Sensors Line Guide

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Installation Instructions for the

Airflow Sensors Line Guide

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

LCZ Series Hall-effect Zero Speed Sensors

AMR 4-Pin Quadrature Sensor Integrated Circuit

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Force Sensors Line Guide

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Installation Instructions for the

MICRO SWITCH NT Series

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

HIH-4602 A & C Series.

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

Intrinsically Safe Transmitters, Option Code 2n

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MICRO SWITCH BX/BX2 Series

MICRO SWITCH NT Series

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Selecting Honeywell Board Mount Pressure Sensors

MICRO SWITCH Basic Switches Line Guide

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Quadrature Speed and Direction Sensors

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Guide to Hazardous Location Approvals:

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

Sensor Evaluation Kit, SEK001

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MICRO SWITCH BAF/DTF Series

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Transcription:

Solid State Sensors Linear Current Sensors CS Series FEATURES Linear output AC or DC current sensing Through-hole design Fast response time Output voltage isolation from input Minimum energy dissipation Maximum current limited only by conductor size Adjustable performance and built-in temperature compensation assures reliable operation Accurate, low cost sensing Operating temperature range 25 to 85 C Housing: PET polyester LINEAR CURRENT SENSORS MICRO SWITCH CS series linear current sensors incorporate our 91SS12-2 and SS94A1 linear output Hall effect transducer (LOHET TM ). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configuration as shown in mounting dimension figures 1, 1a, 2 and 2a. Normal mounting is with 0.375 inch long 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric. ORDER GUIDE BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Sensed Sensitivity Mtg. Supply Supply Current Offset mv N* Offset Response Catalog Dim. Volt. Current (Amps Volt. At 12 VDC Shift Time Listing Fig. (Volts DC) (ma Max.) Peak) (Volts±10%) Nominal ± TOL (%/ C) (µ Sec.) CSLA1CD 1 8 to 16 19 57 Vcc/2 49.6 5.8 ±.05 3 CSLA1CE 1 8 to 16 19 75 Vcc/2 39.4 4.4 ±.05 3 CSLA1DE 2 8 to 16 19 75 Vcc/2 39.1 4.8 ±.05 3 CSLA1CF 1 8 to 16 19 100 Vcc/2 29.7 2.7 ±.05 3 CSLA1DG 2 8 to 16 19 120 Vcc/2 24.6 2.1 ±.05 3 CSLA1CH 1 8 to 16 19 150 Vcc/2 19.6 1.8 ±.05 3 CSLA1DJ 2 8 to 16 19 225 Vcc/2 13.2 1.2 ±.05 3 CSLA1EJ 1a 8 to 16 19 225 Vcc/2 13.2 1.5 ±.05 3 CSLA1DK 2 8 to 16 19 325 Vcc/2 9.1 1.7 ±.05 3 CSLA1EK 1a 8 to 16 19 325 Vcc/2 9.4 1.3 ±.05 3 CSLA1EL 1a 8 to 16 19 625 Vcc/2 5.6 1.3 ±.05 3 BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT - Sensed Sensitivity Mtg. Supply Supply Current Offset mv N* Offset Response Catalog Dim. Volt. Current (Amps Volt. At 8 VDC Shift Time Listing Fig. (Volts DC) (ma Max.) Peak) (Volts±2%) Nominal ± TOL (%/ C) (µ Sec.) CSLA2CD 1 6 to 12 20 72 Vcc/2 32.7 3.0 ±.02 3 CSLA2CE 1 6 to 12 20 92 Vcc/2 26.1 2.1 ±.02 3 CSLA2DE 2 6 to 12 20 92 Vcc/2 25.6 2.2 ±.02 3 CSLA2CF 1 6 to 12 20 125 Vcc/2 19.6 1.3 ±.02 3 CSLA2DG 2 6 to 12 20 150 Vcc/2 16.2 1.1 ±.02 3 CSLA2DJ 2 6 to 12 20 225 Vcc/2 8.7 0.6 ±.020 3 CSLA2DH 2 6 to 12 20 235 Vcc/2 9.8 1.1 ±.0125 3 CSLA2EJ 1a 6 to 12 20 310 Vcc/2 7.6 0.7 ±.0125 3 CSLA2DK 2 6 to 12 20 400 Vcc/2 5.8 0.5 ±.0125 3 CSLA2EL 1a 6 to 12 20 550 Vcc/2 4.3 0.4 ±.0125 3 CSLA2EM 1a 6 to 12 20 765 Vcc/2 3.1 0.3 ±.007 3 CSLA2EN 1a 6 to 12 20 950 Vcc/2 2.3 0.2 ±.007 3 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N=number of turns PDFINFO p a g e 0 5 8 58 HoneywellSensingandControl 1-800-537-6945USA 1-815-235-6847 International 1-800-737-3360 Canada

CSLW Series Miniature Wired Open-Loop Current Sensors DESCRIPTION Honeywell s CSLW Series miniature, open-loop current sensors incorporate our SS490 Series miniature ratiometric linear Hall-effect sensor (MRL TM ). The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor, flux collector, housing, and wire coil comprises the current sensor assembly. These sensors are ratiometric. FEATURES Wired open-loop design with multiple turns for increased sensitivity ac or dc current sensing Linear ratiometric output Current sinking or sourcing output for interfacing flexibility Low insertion loss Fast response time Compact size for applications with limited space Accurate, low-cost sensing Minimum energy dissipation Maximum current limited only by conductor size Built-in temperature compensation promotes reliable operation Operating temperature range -25 C to 100 C [-13 F to 212 F] RoHs compliant (lead-free) POTENTIAL APPLICATIONS Motor control in appliances, HVAC and consumer tools Current monitoring of electronic circuits Overcurrent protection Ground fault detectors Robotics Industrial process control UPS and telecommunication power supplies Welding current monitoring Battery management systems in mobile equipment Watt meters Variable speed drives

CSLW Series PRODUCT SPECIFICATIONS Product type Package quantity/type Package style Supply voltage Output type Magnetic actuation type miniature hall-effect linear open-loop current sensor 25 per box PC board mount radial lead IC 4.5 Vdc to 10.5 Vdc sink/source analog ratiometric Parameter CSLW6B1 CSLW6B5 CSLW6B40M CSLW6B200M Units Symbol Conditions Current range (min.) ±1 A ±5 A ±40 ma ±200 ma Ip <±1.5 % error (-25 C to 100 C [-13 F to 212 F]) Supply voltage 4.5 to 10.5 4.5 to 10.5 4.5 to 10.5 4.5 to 10.5 V V s V out @ 0 AT 2.50 ±0.15 2.50 ±0.15 2.50 ±0.15 2.50 ±0.15 V V o Supply current typ. 7 7 7 7 max. 9 9 9 9 ma I s No Load Turns 60 ±1 12 1500 ±20 300 ±5 N Coil resistance typ. 0.16 0.01 120 4 Ω Sensitivity min. 898 179 22400 4500 mv/a V/ I -25 C to 100 C typ. 1020 204 25500 5100 [-13 F to 212 F] max. 1142 229 30000 5700 Hysteresis max. 0.5 0.5 0.5 0.5 % @ min current range Temp error null max. ±0.064 ±0.064 ±0.064 ±0.064 %/ C TC Vo/Vo Temp error - gain max. -0.03 +0.12-0.03 +0.12-0.03 +0.12-0.03 +0.12 %/ C TC G -25 C to 100 C [-13 F to 212 F] Rise time typ. 3 3 3 3 µs t r 0 to 40% of min current range BLOCK DIAGRAM CSLW6B5 TYPICAL TRANSFER FUNCTION [25 C] CSLW6B1 TYPICAL TRANSFER FUNCTION [25 C] 2 www.honeywell.com/sensing

Miniature Wired Open-Loop Current Sensors CSLW6B40M TYPICAL TRANSFER FUNCTION [25 C] CSLW6B200M TYPICAL TRANSFER FUNCTION [25 C] DIMENSIONAL DRAWING (For reference only [mm)) ORDER GUIDE Catalog Listing CSLW6B1 CSLW6B5 CSLW6B40M CSLWB200M Description CSLW Series, Miniature, Open-Loop Current Sensor, 1 A CSLW Series, Miniature, Open-Loop Current Sensor, 5 A CSLW Series, Miniature, Open-Loop Current Sensor, 40 ma CSLW Series, Miniature, Open-Loop Current Sensor, 200 ma Honeywell Sensing and Control 3

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 www.honeywell.com/sensing 005861-1-EN IL50 GLO Printed in USA November 2005 2005 Honeywell International Inc.

CSLT Series Miniature, Open-Loop Current Sensors DESCRIPTION Honeywell s CSLT Series miniature, open-loop current sensors incorporate our SS490 Series miniature ratiometric linear Halleffect sensor (MRL TM ). The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor, flux collector and housing comprises the current sensor assembly. These sensors are ratiometric. FEATURES Open-loop, through-hole design Output voltage isolation from input ac or dc current sensing Linear ratiometric output Current sinking or sourcing output for interfacing flexibility Fast response time Compact size Accurate, low-cost sensing Minimum energy dissipation Maximum current limited only by conductor size Built-in temperature compensation promotes reliable operation Operating temperature range -25 C to 100 C [-13 F to 212 F] RoHs compliant (lead-free) POTENTIAL APPLICATIONS Motor control in appliances, HVAC and consumer tools Current monitoring of electronic circuits Overcurrent protection Ground fault detectors Robotics Industrial process control UPS and telecommunication power supplies Welding current monitoring Battery management systems in mobile equipment Watt meters Variable speed drives

CSLT Series PRODUCT SPECIFICATIONS Product type Package quantity/type Package style Supply voltage Output type Magnetic actuation type miniature hall-effect linear open-loop current sensor 25 per box PC board mount radial lead IC 4.5 Vdc to 10.5 Vdc sink/source analog ratiometric Parameter Symbol Min. Typ. Max. Units Condition Current range Ip ±100 AT <±1.5 % error (-25 C to 100 C [-13 F to 212 F]) Supply voltage V s 4.5 5 10.5 V V out @ 0 NI V o 2.35 2.5 2.65 V Supply current I s 7 9 ma no load Sensitivity V/I 13.5 16 18.5 mv/at -25 C to 100 C [-13 F to 212 F] Hysteresis 0.5 % ±100 A Temp error - null TC Vo/Vo -0.064 0.064 %/ C Temp error - gain TC G -0.03 0.12 %/ C -25 C to 100 C [-13 F to 212 F] Rise time t r 3 µs 0 A to 2.0 A BLOCK DIAGRAM CSLT6B100 TYPICAL TRANSFER FUNCTION [25 C] 2 www.honeywell.com/sensing

Miniature, Open-Loop Current Sensors DIMENSIONAL DRAWING (For reference only [mm]) ORDER GUIDE Catalog Listing CSLTB100 Description CSLT Series, Miniature, Open-Loop Current Sensor, 100 A Honeywell Sensing and Control 3

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 www.honeywell.com/sensing 005862-1-EN IL50 GLO Printed in USA November 2005 2005 Honeywell International Inc.

CSLS Series Miniature Open-Loop Current Sensors DESCRIPTION Honeywell s CSLS Series miniature, open-loop current sensors incorporate our SS490 Series miniature ratiometric linear Halleffect sensor (MRL TM ). The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor, flux collector and housing comprises the current sensor assembly. These sensors are ratiometric. FEATURES Open-loop, through-hole design Output voltage isolation from input ac or dc current sensing Linear ratiometric output Current sinking or sourcing output for interfacing flexibility Fast response time Compact size Accurate, low-cost sensing Minimum energy dissipation Maximum current limited only by conductor size Built-in temperature compensation promotes reliable operation Operating temperature range -25 C to 100 C [-13 F to 212 F] RoHs compliant (lead-free) POTENTIAL APPLICATIONS Motor control in appliances, HVAC and consumer tools Current monitoring of electronic circuits Overcurrent protection Ground fault detectors Robotics Industrial process control UPS and telecommunication power supplies Welding current monitoring Battery management systems in mobile equipment Watt meters Variable speed drives

CSLS Series PRODUCT SPECIFICATIONS Product type Package quantity/type Package style Supply voltage Output type Magnetic actuation type miniature hall-effect linear open-loop current sensor 25 per box PC board mount radial lead IC 4.5 Vdc to 10.5 Vdc sink/source analog ratiometric Parameter Symbol Min. Typ. Max. Units Condition Current range Ip ±60 AT <±1.5 % error (-25 C to 100 C [-13 F to 212 F]) Supply voltage V s 4.5 5 10.5 V V out @ 0 NI V o 2.35 2.5 2.65 V Supply current I s 7 9 ma no load Sensitivity V/I 15 17 19 mv/at -25 C to 100 C [-13 F to 212 F] Hysteresis 0.5 % ±60 A Temp error - null TC Vo/Vo -0.064 0.064 %/ C Temp error - gain TC G -0.03 0.12 %/ C -25 C to 100 C [-13 F to 212 F] Rise time t r 3 µs 0 A to 2.0 A BLOCK DIAGRAM CSLS6B60 TYPICAL TRANSFER FUNCTION [25 C] 2 www.honeywell.com/sensing

Miniature Open-Loop Current Sensors DIMENSIONAL DRAWING (For reference only [mm]) 1. Vs (+) 2. GND (-) 3. OUTPUT ORDER GUIDE Catalog Listing CSLS6B60 Description CSLS Series, Miniature, Open-Loop Current Sensor, 60 A Honeywell Sensing and Control 3

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 www.honeywell.com/sensing 005863-1-EN IL50 GLO Printed in USA November 2005 2005 Honeywell International Inc.

PDFINFO p a g e - 0 5 9 Solid State Sensors Linear Current Sensors CS Series SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Sensitivity Sensed Mtg. Supply Supply Current Offset mv N* Offset Response At 12 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (ma Max.) Peak) (Volts±10%) Nominal ± TOL (%/ C) (µ Sec.) CSLA1GD 2a 8 to 16 19 57 Vcc/2 49.6 5.8 ±.05 3 CSLA1GE 2a 8 to 16 19 75 Vcc/2 39.4 4.4 ±.05 3 CSLA1GF 2a 8 to 16 19 100 Vcc/2 29.7 2.7 ±.05 3 SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Sensitivity Sensed mv N* Mtg. Supply Supply Current Offset Offset Response At 8 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (ma Max.) Peak) (Volts±2%) Nominal ± TOL (%/ C) (µ Sec.) CSLA2GD 2a 6 to 12 20 72 Vcc/2 32.7 3.0 ±.02 8 CSLA2GE 2a 6 to 12 20 92 Vcc/2 26.1 2.1 ±.02 8 CSLA2GF 2a 6 to 12 20 125 Vcc/2 19.6 1.3 ±.02 8 CSLA2GG 2a 6 to 12 20 150 Vcc/2 12.7 0.6 ±.02 8 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns. MOUNTING DIMENSIONS (for reference only) Figure 1 Figure 2 Figure 1a Figure 2a Current * Application consideration: The output is clamped at the high end. Clamping voltage may be as low as 9VDC. The output will not exceed the clamping voltage regardless of field strength or supply voltage. HoneywellSensing and Control 1-800-537-6945USA 1-815-235-6847 International 1-800-737-3360 Canada 59