ECL Comfort V a.c. and 24 V a.c.

Similar documents
ECL Comfort V a.c. and 24 V a.c.

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

ECL Comfort 300 / V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ECL Comfort 110, application 116

Weather compensated flow temperature control of heating and boiler systems

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 110, application 130

Installation Guide. ECL Comfort 210, application A Table of Contents

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

ECL Comfort 210 / 296 / 310

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition

120+ Get your job done swiftly Easy selection of your application is the key. applications.

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

ECL Comfort 210/296/310, application A247/A347

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVL470. Heating Controller. Use. Functions. Series B

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

RVP310. Heating Controller. Building Technologies HVAC Products

ECL Comfort 210/296/310, application A217/A317

RVL481. Heating Controller. including d.h.w. heating

RVL480. Heating Controller

PROMATIC WDC Heating controllers Energy under control

Immersion Temperature Controller

TR 0603mc U Solar Controller

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

PRELIMINARY EDITION

G a

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat

Instructions. VX Solo II. 1.0 Table of contents

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Solar controllers Energy under control

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Wall-mounted substation PKL-113

I/A Series 716C 1/16 DIN Temperature Controller

Overview - Danfoss Link and living software versions

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Temperature Controllers

Corrigo E. Second generation which contains all applications and languages

- Data Brochure Universal Reset Module 423

Control solutions Biofloor

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Room Temperature Controller

- Data Brochure Boiler Control 274

Self-learning Room Temperature Controller

Overview - Danfoss Link and living software versions

Technical Paper. Auto tuning and motor protection as part of the pre-setting procedure in a heating system

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

- Data Brochure Universal Reset Module 422

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Watts Under Floor Multi-zone Controller User Manual

Use. Functions. Key function. Other functions

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Heating controller Lago

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual

Heating Control Danfoss Link & Connect Thermostats

LC2200 Level Controller Installation and Maintenance Instructions

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

RVL479. Heating Controller. for use with a partner unit

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

SMART THERMOSTAT WITH HOT WATER CONTROL

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

EC3-X33 Stand-alone Superheat Controller Technical Data

english Steca Solar Thermal hot water from the sun. Solar Thermal

OJ Waterline control system

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Room Unit. Building Technologies SYNERGYR

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

for relative humidity and temperature

prestige Control Application Supplement - ACVMax

QAW70. Room Unit. Building Technologies. for use with heating controllers

BC3250. Blowdown Controller

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Control Application. Supplement - ACVMax

prestige Control Application Supplement - TriMax

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Labkotec Ice Detector

Odyssey. issue 01c. system manual

02/11/2015

Heat Link. Technical Guide

THERMASREG TR 040 THERMASREG TR 060

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

T5000 LCD Digital Fan Coil Thermostat

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Transcription:

230 V a.c. and 24 V a.c. Description and application The controller is designed for easy installation: one cable, one connector. The controller has a customdesigned display with backlight. For a quick overview, the display readouts are based on graphic symbols as well as text. The controller has triac outputs for motorized control valve and relay outputs for pump control. The is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased systems. The product is an electronic controller for weather compensated flow temperature control (heating) constant temperature control (domestic hot water e.g.) and prepared for new applications by means of chip card and communication interface. It is possible to connect up to 4 temperature sensors (Pt 1000 types) and it has 1 input for override. Room panel or remote control (ECA 60 / 61) can be connected. The controller can be used as master or slave in controller systems. It is prepared for mounting on a DIN rail, a wall or in a panel. Ordering Controllers Type Designation Code no. Universal hardware - 230 V a.c. 087B1261 Universal hardware - 24 V a.c. 087B1251 with timer program Universal hardware - 230 V a.c. 087B1262 with timer program Universal hardware - 24 V a.c. 087B1252 Panel mounting kit For 087B1249 Instructions, appl. 116 User guide and quick guide (English) 087B8151 Instructions, appl. 130 User guide and quick guide (English) 087B8152 Pt 1000 temperature sensors Type Designation Code No. ESMT Outdoor temperature sensor 084N1012 ESM-10 Room temperature sensor 087B1164 ESM-11 Surface sensor 087B1165 ESMB-12 Universal sensor 087B1184 ESMC Surface sensor incl. 2 m cable 087N0011 ESMU-100 Immersion sensor, 100 mm, copper 087B1180 ESMU-250 Immersion sensor, 250 mm, copper 087B1181 ESMU-100 Immersion sensor, 100 mm, stainless steel 087B1182 ESMU-250 Immersion sensor, 250 mm, stainless steel 087B1183 DH-SMT/DK VD.KT.C3.02 Danfoss 09/2008 1

Ordering, continued Accessories Type Designation Code no. ECA 60 Room panel with sensor 087B1140 ECA 61 Remote control with 1 zone clock and sensor 087B1141 ECA 110* Timer program for (chip card) 087B1248 * The ECA 110 is a supplement to the versions without a timer program, e.g., the code nos. 087B1261 and 087B1251 (see page 1). With the ECA 110 it will be possible to set personal schedules in terms of start and stop times of the system and thereby optimize the energy supply. Domestic hot water (DHW) (Application 116) Application 116 example Constant DHW temperature control with heat exchanger Basic principles Constant DHW temperature control with heat exchanger or storage tank Typically, the flow temperature is adjusted according to the desired flow temperature. Adjustment of DHW temperature If the measured DHW temperature is lower than the desired temperature, the motorized control valve is opened gradually and vice versa. Return temperature limitation The return temperature to the district heating supply should not be too high. If so, the desired flow temperature can be adjusted (typically to a lower value) thus resulting in a gradual closing of the motorized control valve. In boiler-based heating supply the return temperature should not be too low (same adjustment procedure as above). Circulation pump control The circulation pump is ON when the desired DHW temperature is higher than a userdefined value (factory setting: 20 C). 2 VD.KT.C3.02 Danfoss 09/2008 DH-SMT/DK

Key functions Flow temperature control Return temperature limitation The controller automatically changes the desired flow temperature to obtain an acceptable return temperature when the return temperature falls below or gets higher than the set value. The return temperature influence can be limited by the min. / max. flow limitation. Optimization Auto tuning A function for automatically setting the proportional band (Xp) and integration time constant (Tn). Safety functions Frost protection The controller automatically switches the circulation pump ON when the flow temperature is lower than a user-defined value (factory setting: 10 C). Motor protection The controller prevents unstable temperature control thus resulting in a longer life of the actuator. Pump exercise Exercise of the pump to avoid blocking in periods without heat demand. Heating (Application 130) Application 130 examples District heating circuit with heat exchanger Boiler-based heating circuit DH-SMT/DK VD.KT.C3.02 Danfoss 09/2008 3

Basic principles Control of district heating circuits with or without heat exchanger and for boiler-based heating circuits Typically, the flow temperature is adjusted according to the desired flow temperature. Adjustment of flow temperature The desired flow temperature is calculated in the ECL Comfort controller, based on the outdoor temperature. The lower the outdoor temperature, the higher the desired flow temperature. The motorized control valve is opened gradually when the flow temperature is lower than the desired flow temperature and vice versa. Return temperature limitation The return temperature to the district heating supply should not be too high. If so, the desired flow temperature can be adjusted (typically to a lower value) thus resulting in a gradual closing of the motorized control valve. In boiler-based heating supply the return temperature should not be too low (same adjustment procedure as above). Room temperature limitation If the measured room temperature does not equal the desired room temperature, the desired flow temperature can be adjusted. Circulation pump control The circulation pump is ON when the desired flow temperature is higher than a user-defined value (factory setting: 20 C ) or the outdoor temperature is lower than a user-defined value (factory setting: 2 C). 4 VD.KT.C3.02 Danfoss 09/2008 DH-SMT/DK

General data Ambient temperature 0-55 C Storage temperature -40 - + 70 C Enclosure Sensor type DIN rail, wall or panel Pt 1000 (1000 Ω @ 0 C) Grade of enclosure IP 41 DIN 40050 - marking in accordance with the standards EMC-Directive: 2004/108/EC Immunity: 61000-6-1 Emission: 61000-6-3 LVD-Directive: 2006/95/EC Wiring - 230 V a.c. * Connections for safety thermostat Supply voltage 230 V a.c. - 50 Hz Voltage range 207 to 244 V a.c. (IEC 60038) Power consumption 3 VA Load on relay 1 outputs 4 (2) A - 230 V a.c. Load on triac outputs 15 VA @ 230 V a.c. Wiring - 24 V a.c. * Connections for safety thermostat Supply voltage 24 V a.c. - 50 Hz Voltage range 21.6 to 26.4 V a.c. (IEC 60038) Power consumption 3 VA Load on relay 2 outputs 4 (2) A - 230 V a.c. Load on triac outputs 15 VA @ 24 V a.c. DH-SMT/DK VD.KT.C3.02 Danfoss 09/2008 5

Operation Adjust temperatures and values. Switch between menu lines. Select / return. 2 sec. Return to daily user menu. Menu navigation 6 VD.KT.C3.02 Danfoss 09/2008 DH-SMT/DK

Dimensions Cut-out for mounting Mounting in a panel (panel mounting kit, code no.: 087B1249). The panel thickness must not exceed 5 mm. DH-SMT/DK VD.KT.C3.02 Danfoss 09/2008 7

Additional documentation for is available on http://heating.danfoss.com 8 VD.KT.C3.02 Produced by Danfoss A/S 09/2008