B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

SECTION DOOR HARDWARE

HALIFAX HUMANE SOCIETY ADDITIONS AND ALTERATIONS. B. See Division 08 door sections for astragals and door silencers.

SECTION DOOR HARDWARE

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

2. Interior doors shall be not less than 18 gauge steel.

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

SECTION INTEGRATED DOOR ASSEMBLIES

SEQUOYAH SCHOOLS FI&R 06 G01 Cherokee Nation Tahlequah, Oklahoma

DOOR HARDWARE

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

APPENDIX F: LOCKSETS AND ACCESS CONTROL

1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated.

ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA

SECTION DOOR HARDWARE

C. Thresholds, weatherstripping, seals and door gaskets. A. ANSI/ICC A117.1 Standard for Accessibility and Usable Buildings and Facilities; 1998

Lake County / Multi-Department Storage Facility / Project / December 05, 2016 SECTION DOOR HARDWARE

Card Access Control Specifications

Architect s Specification Guideline:

FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS. A. Provide finish hardware including necessary accessories.

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

New Bedford, Massachusetts Tel: (617) CBI Job No.: Fax: (617)

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

106. LOCK AND CARD ACCESS GENERAL DESIGN INFORMATION

SECTION &.40 DOOR HARDWARE

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

THE LEDGE AT CABOT DRIVE. NASHVILLE, TN

SECTION FINISH HARDWARE

Architectural Specification Sheet

April 2, 2019 ADDENDUM NO. 3 DEPARTMENT OF PUBLIC WORKS OPERATIONS BUILDING

SECTION DOOR HARDWARE

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

CARD ACCESS CONTROL SYSTEM

ARCHITECTURAL SPECIFICATIONS

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project]

DIVISION 10 SPECIALTIES

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SECTION INTRUSION DETECTION

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

v.3.1: December 19, 2014

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project and Confirm with University Lock Shop]

SECTION SECURITY TESTING AND COMMISSIONING

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE

DE5300 Delayed Egress System. General Information

BuildingName The Description of the Project P DOCUMENTS

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

Remote Chexit Module (RCM) System. General Information

About the Instructor & Presenter:

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

ABLOY EFEND. New name for security

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Architectural Guide /ING BuyLine 4081

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION HARDWARE

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SECTION NURSE CALL SYSTEM

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

5900 SERIES Low Energy Power Operator

2408/2900. Fire Guard

EntryCheck E70 Series

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

COMBINED CONTRACT Nov. 10, NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL

ARCHITECTURAL SPECIFICATIONS

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

2409/2900. Fire Guard

AO19 SERIES LOW ENERGY AUTOMATIC DOOR OPERATORS

Monarch Electrified Series

SECTION AUTOMATIC TRANSFER SWITCHES

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION FIRE EXTINGUISHER CABINETS

5600 series. Low Energy Power Operator

Appendix 1 LACCD Districtwide Security Performance Requirements

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

DESIGN GUIDELINES AND STANDARDS

5900 Series X-in Low Energy Power Operator

USD 380 Centralia, Frankfort & Vermillion

EcoAisle Thermal Containment System

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Access Control System - CAAMS. Basis of Design

Revitalize Building Mechanical Systems (4619)

Solutions for Common Problems

/ How To Order

PART 1 GENERAL 1.01 SUMMARY

Transcription:

SECTION 08711 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 3. Electrified door hardware. 1.2 SUBMITTALS A. Product Data: For each product indicated. B. Shop Drawings: Include details of electrified door hardware and wiring diagrams. C. Samples: For each exposed finish. D. Door Hardware Schedule: Organized into door hardware sets indicating type, style, function, size, label, hand, manufacturer, fasteners, location, and finish of each door hardware item. Include description of each electrified door hardware function, including sequence of operation. E. Templates: Submit template information for finish hardware to suppliers of aluminum entrances, hollow metal and wood doors for production after hardware schedule approval. F. Keying Schedule: Detail Owner's final keying instructions for locks. G. Product certificates. H. Certification from the manufacturer for access control, elevator control, and gate control for all field level service providers and installers. 1.3 QUALITY ASSURANCE A. Supplier Qualifications: Person who is or employs a qualified DHI Architectural Hardware Consultant. B. Source Limitations: Refer to Door Hardware Schedule C. Keying Conference: Conduct conference at Project site. Incorporate keying conference decisions into final keying schedule. D. Templates: Obtain and distribute templates for doors, frames, and other work specified to be factory prepared for installing door hardware. 08711-1 LK 15173

E. Access Control: Contractor shall have service representation within 100 miles of the project location. 1.4 Delivery, Storage and Handling. A. Marking and Packaging: Hardware delivered in original packaging and marked by architectural door opening number according to approve hardware schedule to identify correct location. B. Delivery: Hardware supplier will deliver finish hardware to job site in a timely manner per job completion schedule. Inventory and verify all hardware per approved door hardware schedule. Supply any material not accounted for. C. Storage: Store hardware in a locked on-site location to ensure protection of material and finish. Hardware to b stored on shelves off floor & grouped by hardware type in clean, dry & secure area. 1.5 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within warranty period. 1. Warranty Period for Electromagnetic and Delayed Egress Locks: Five years from date of Substantial Completion. 2. Warranty Period for Exit Devices: Three years from date of Substantial Completion 3. Warranty Period for Lock sets: Lifetime from date of Substantial Completion 4. Warranty Period for Door Accessories: One years from date of Substantial Completion. 5. Warranty Period for Closers: Lifetime from date of Substantial Completion. 6. Warranty for Access Control: One year from date of Substantial Completion. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Product: Subject to compliance with requirements, provide the product named for each door hardware item indicated in Door Hardware Sets. 1. For this project the following products only will be considered. Specified items listed in sets. Equals are as follows: a. Butts Ives, Bommer, Hager b. Closers Falcon, Hager 5300, LCN c. Locks (Common) Falcon, Hager, Schlage d. Locksets ( Room Entries ) Schlage No Substitution e. Panics Falcon, Hager, Von Duprin f. Stops Ives, Hager g. Push-pull, Kicks Ives, Hager h Weather Stripping National Guard, Zero, Reese 08711-2 LK 15173

i Door Sweeps National Guard, Zero, Reese j. Thresholds National Guard, Zero, Reese k Electronic Locks Schlage Electronics No Substitution l Viewers/Door Guard Ives, Hager m. Interior Unit Locks Dexter No Substitution n. Exits W/access control Von Duprin No Substitution o. Access Control Software Schlage Electronics and Components No Substitution 2.2 KEYING A. All keying shall be accomplished per Owner Requirements. A complete keying schedule shall be submitted to the Owner and approved in writing prior to placing lock order with the factory. B. All lock cylinders are to be master keyed. All locks and cylinders shall be supplied with a visual key control system. All key bows shall also be stamped indicating applicable day change and number of that key (E.G. 12AB47). 1. Furnish two (2) change keys for each lockset and a total of six master keys, grand master keys. C. Provide construction cylinders of cores for all exterior entrance used by the contractors during construction. General contractor shall replace temporary locks or cylinders with permanent units at the completion of project. All locks to be construction keyed. D. Provide and comply with ANSI 7.1,4.27 (hazard warnings). E. Provide and comply with ANSI a117.1,4.13 (handicap access) 2.3 DOOR HARDWARE A. Scheduled Door Hardware: Provide door hardware according to Door Hardware Sets at the end of Part 3. Manufacturers' names are abbreviated. B. All materials can be procured from the following Owner preferred vendor: American Direct Procurement 11000 Lakeview Avenue Lenexa, KS 66219 (913) 677-5588 Attn: Jerry Pennington Email: JerryP@AmericanDirectCo.com 08711-3 LK 15173

2.4 FABRICATION A. Base Metals: Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18 for finishes. Do not furnish manufacturer's standard materials if different from specified standard. B. Fasteners: Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated. Provide steel machine or wood screws or steel through bolts for fire-rated applications. C. Spacers or Sex Bolts: For through bolting of hollow metal doors. D. Fasteners for Wood Doors: Comply with requirements of DHI WDHS.2, "Recommended Fasteners for Wood Doors." E. Finishes: Comply with BHMA A156.18. 2.5 ELEVATOR CONTROL A. Basis of design is: Schlage SMS Premier Software, controllers, reader interface, and readers. System shall be compatible with the FE210 residential locks and the AD-400 access control openings. B. Controller shall provide an Ethernet connection to Owner supplied LAN C. Reader interface shall be compatible to the Access Control software provided and all for connection to a 125 KHz proximity reader and 13.56 MHz smart card reader. D. Input Output board shall provide elevator control for up to 5 floors and shall be compatible with the Access Control software and controllers provided. E. Security Contractor shall be responsible for coordinating with the Elevator Contractor to provide a working solution as describe by the owner in preconstruction meetings. F. Elevator Control parts: SRCNX-R Schlage reader controller SRINX Schlage reader interface SIONX-8NB Schlage input output board SXF1500 Schlage Multi-Tech reader G. Coordinate all required activity with the Owner Elevator Contracting Company in pre-bid, installation, and post-bid meetings. H. Provide, install, and program a by floor control and working system as required by the Owner. 08711-4 LK 15173

I. Provide and install all associated cable required, with the exception of the Elevator Travel Cable. Elevator Travel Cable to be provided and installed by Elevator Contractor. 2.6 GATE CONTROL A. Basis of design is: Schlage Wireless Reader Interface and Schlage software. System shall be compatible with the FE210 residential locks and the AD-400 access control openings. B. Provide and install a SSRC-400 wireless control to the Owner supplied LAN with Ethernet within 350 of the LAN Switch or Router C. Provide and install a PIM400-485-SMS wireless transceiver on the outside of the building within 1000 line-of-sight to the gate controller. D. Provide and install a WRI400 wireless reader interface at the Gate Control arm provided by the Gate Contractor. Provide Mast and mounting hardware for WRI400 if required for line-of-sight to PIM400 unit. E. Provide and install the PS902xBBK power supply in the Gate Arm Control enclosure. 120 VAC to be provided by the Electrical contractor. Coordinate 120 VAC requirements. F. Provide and install the SXF1500 card reader on the pedestal provided by the Gate Contractor. G. Provide and install all associated cables for a working system. PART 3 - EXECUTION 3.1 INSTALLATION A. Examine doors and frames for compliance with requirements for installation tolerances, labeled fire door assembly construction, wall and floor construction, and other conditions affecting performance. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation. B. Steel Door and Frame Preparation: Comply with DHI A115 series. Drill and tap doors and frames for surface-applied hardware according to SDI 107. C. Wood Door Preparation: Comply with DHI A115-W series. D. Mounting Heights: Comply with the following requirements, unless otherwise indicated: 1. DHI's "Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames." 2. DHI's "Recommended Locations for Builders' Hardware for Custom Steel Doors and Frames." 08711-5 LK 15173

3. DHI WDHS.3, "Recommended Locations for Architectural Hardware for Wood Flush Doors." E. Adjust and reinforce attachment substrates as necessary for proper installation and operation. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.. 1. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings. Verify location with Architect. 2. Thresholds: Set thresholds for exterior in full bed of sealant. Complying with other requirements specified in Division 7 Section "Joint Sealants." F. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with accessibility requirements. 1. Door Closers: Adjust sweep period so that from an open position of 70 degrees, the door will take at least three seconds to move to a point 3 inches from the latch, measured to the leading edge of the door. G. Elevator Control 1. Schlage Authorized Contractor shall provide, install, commission and warranty an elevator control system that provides By-Floor control by valid credential. 2. Contractor shall coordinate all elevator control connections and cabling with the Owner s Elevator Contractor. 3. Contractor shall mount the reader controller, the reader interface, the low voltage power supply and the input/output board in the elevator control room and shall terminate the Travel Cable 18/6C OAS provided by the Elevator Contractor to the reader interface and the multi-technology reader in the cab. 4. Contractor shall program the access control software to provide By-Floor access as required by the Owner for the initial installation. 5. Contractor shall follow all local and national code requirements for elevator control. H. Gate Control 1. Schlage Authorized Contractor shall provide, install, commission and warranty a wireless gate control system that provide gate access control by valid credential and connects to the building access control system. 2. Authorized Contractor shall coordinate all gate control activity with the Gate Contractor and all 120 VAC requirements with Electrical Contractor. 3. Shall install all equipment as per manufacture recommendations and requirements. 4. Shall install all equipment as to meet all local, state, and national code regulations for gate control installations. 5. Shall program the initial test credential into the system and show owner representative how to program the gate control. 08711-6 LK 15173

PART 4 - HARDWARE SCHEDULE Hardware Group No. 01 A 2 EA SPRING HINGE 3SP1 4.5 X 4.5 652 IVE 1 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA INTERCONNECT LOCK FE210F JAZZ 626 SCH 1 EA KICK PLATE 8400 6" X 2" LDW 630 IVE 1 SET SEALS 2525B BRN NGP 1 EA DOOR GUARD 482 W/ EDGE GUARD 626 IVE 1 EA ROLLER BUMPERS RB470 626 IVE 1 EA DOOR VIEWER / KNOCKER 31251U W/ U700 VIEWER 626 IVE Hardware Group No. 02 B 1 EA PRIVACY SET J40 DOV 630 DEX 1 EA DOOR STOP 061 652 IVE BATH DOOR HINGES BY THE PREHUNG DOOR SUPPLIER Hardware Group No. 03 C 1 EA PRIVACY SET J40 DOV 630 DEX 1 EA DOOR STOP 061 652 IVE BEDROOM DOOR HINGES BY THE PREHUNG DOOR SUPPLIER Hardware Group No. 04 D E 1 EA PASSAGE SET J10 DOV 630 DEX 1 EA DOOR STOP 061 652 IVE CLOSET DOOR HINGES BY THE PREHUNG DOOR SUPPLIER PROVIDE A ROLLER STOP ON TYPE E OPENINGS AND ON D OPENINGS THAT OPEN AGAINST THE ENTRY DOOR Hardware Group No. 05 08711-7 LK 15173

1150B 1152B 1250 1252 1350 1352 1450 1452 2150B 2152B 2250 2252 2350 2352 2450 2452 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA ELECT AD-400-993R-70-MT-ATH-PD 626 SCE CLASSROOM/STOREROO M LOCK 1 EA FIRE EXIT HARDWARE 99-EO-F 626 VON 1 EA SURFACE CLOSER SC81 RW/PA FULL TBWMS 689 FAL 1 EA KICK PLATE 8400 6" X 2" LDW 630 IVE 1 EA WALL STOP WS407CCV 630 IVE 1 SET SEALS 2525B BRN NGP Hardware Group No. 06 1131 1150A 1152A 2131 2150A 2152A 1 EA ELECT AD-400-993R-70-MT-ATH-PD 626 SCE CLASSROOM/STOREROO M LOCK 1 EA PANIC HARDWARE 99-EO 626 VON REMAINDER OF HARDWARE BY THE DOOR SUPPLIER Hardware Group No. 07 1132a 2132a Provide each PR door(s) with the following: 2 EA CYLINDERS AS REQUIRED REMAINDER OF HARDWARE BY THE DOOR SUPPLIER Hardware Group No. 07A 1132b 2132b Provide each PR door(s) with the following: 1 EA ELECT AD-400-993R-70-MT-ATH-PD 626 SCE CLASSROOM/STOREROO M LOCK 2 EA PANIC HARDWARE 9947-EO 626 VON REMAINDER OF HARDWARE BY THE DOOR SUPPLIER Hardware Group No. 08 1133 1136 1238 1332 1338 1432 1438 2133 2136 2238 2332 2338 2432 2438 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 08711-8 LK 15173

1 EA STOREROOM LOCK W581P6D QUA 626 FAL 1 EA SURFACE CLOSER SC81 DS FULL TBWMS 689 FAL 1 SET SEALS 2525B BRN NGP 3 EA SILENCER SR64-1 GRY IVE SILENCERS ON NON RATED OPENINGS GASKETING ON RATED OPENINGS PROVDE PAR ARM CLOSER AND WALL STOP IF A BETTER APPLICATON Hardware Group No. 09 1135 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA PRIVACY LOCK W301S QUA 626 FAL 1 EA WALL STOP WS407CCV 630 IVE 3 EA SILENCER SR64-1 GRY IVE Hardware Group No. 10 1137 1139 1141 1232 2232 3 EA HINGE 5BB1 4.5 X 4.5 630 IVE 1 EA INTERCONNECT LOCK FE210F JAZZ 626 SCH 1 EA SURFACE CLOSER SC81 RW/PA FULL TBWMS 689 FAL 1 EA KICK PLATE 8400 6" X 2" LDW 630 IVE 1 EA WALL STOP WS407CCV 630 IVE 1 SET SEALS 2525B BRN NGP 3 EA SILENCER SR64-1 GRY IVE SILENCERS ON NON RATED OPENINGS GASKETING ON RATED OPENINGS PROVIDE A FLOOR STOP IF A BETTER APPLICATION Hardware Group No. 11 1143 3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE 1 EA ENTRY / OFFICE LOCK W511P6D QUA 626 FAL 1 EA WALL STOP WS407CCV 630 IVE 3 EA SILENCER SR64-1 GRY IVE Hardware Group No. 12 1138A 2138A 3 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE 1 EA FIRE EXIT HARDWARE F-25-R-EO-SNB 626 FAL 08711-9 LK 15173

1 EA SURFACE CLOSER SC71 DS TBWMS 689 FAL 1 EA DRIP CAP 16A CL NGP 1 SET SEALS 160S AL NGP 1 EA DOOR SWEEP 101VA CL NGP 1 EA THRESHOLD 425 AL NGP Hardware Group No. 13 1138B 2138B 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA FIRE EXIT HARDWARE F-25-R-L-510-AVA-SNB W/ 626 FAL FALCON CYL 1 EA SURFACE CLOSER SC81 DS FULL TBWMS 689 FAL 1 SET SEALS 2525B BRN NGP HW SET: 14 DOOR NUMBER: HEAD-END AND ACCES CONTROL MISC EACH TO HAVE: 1 EA ACCESS SOFTWARE SPRE-SFT-1 SCE 2 EA WIRELESS CONTROLLER SSRC-400 SCE 6 EA WIRELESS INTERFACE PIM400-485-SMS SCE 2 EA PWR SUPPLY PS904x900-BBK SCE 15 EA MULTI-CREDENTIAL IBF-110 (ibutton/prox 100 EA FC 2179 Bit 37 SCE start number 1,000) 1 EA HANDHELD DEVICE HHD KIT SCE 1 EA CABLE HH-SERIAL SCE 1 EA ENROLLMENT STATION SENROLL SCE 1 EA CIP MODULE P512112 SCE 1 EA LABOR 32 HOURS INSTALLATION UNK 1 EA LABOR 16 HOURS SYSTEM SETUP AND TRAINING UNK PROVIDE WIRING DIAGRAMS TRAVELING CABLING SUPPLIED AND ISNTALLED BY OTHERS INSTALL SOFTWARE ON OWNER PROVIDED PC AND LAN. Hardware Set: Elevator Control by Floor Qty Description Part # Finish MFR 1 Elevator Controller SRCNX-R WHT SEC 1 Cab Reader Controller SRINX WHT SEC 1 Elevator Input/Output SIONX-8NB N/A SEC 1 Cab Reader SXF1500 BLK SEC 1 Controller power supply with battery backup PS902x900-BBK GRY SEC LOT Misc cables and connectors Misc N/A UNK 1 Wiring Diagram and software programming Note: Contract with Elevator contractor to terminate travel cable for reader on SRINX in the Elevator Control Room 08711-10 LK 15173

Contract with Elevator Contractor to terminate Input/Output cables on elevator control panel to turn on authorized floor button inside the elevator cab. 120 VAC connection required at the PS902 location Security Contractor to program Access Control Software to provide owner required function. PROVIDE WIRING DIAGRAMS GATE OPERATOR, SAFETY LOOPS, AND 120 VAC SUPPLIED AN ISNTALLED BY OTHERS INSTALL SOFTWARE ON OWNER PROVIDED PC AND LAN. Hardware Set: Elevator Control by Floor Qty Description Part # Finish MFR 1 Gate Controller SSRC-400 WHT SEC 1 Gate Wireless Reader Controller WRI400 WHT SEC 1 Gate Transciever PIM400-485-SMS WHT SEC 1 Cab Reader SXF1500 BLK SEC 1 Controller power supply with battery backup PS902x900-BBK GRY SEC LOT Misc cables and connectors Misc N/A UNK 1 Wiring Diagram and software programming Note: Contract with Gate Contractor for all connections to the Gate Operator. Coordinate with the Electrical Contractor for all 120 VAC requirements Security Contractor to program Access Control Software to provide owner required function. END OF SECTION 08711-11 LK 15173