Fire & Security Products Cerberus D100 Multifunctional process control for company security
Danger alarm systems designed for Multifunctional economic efficiency Every company is following the trend of achieving greater economic efficiency. Concentration on clear objectives, streamlined organization and core competence areas are the tools that allow these requirements to be met. In addition to the processes associated with core competence areas, there are a number of other framework processes that are A danger alarm system is multifunctional if it required for maintaining the functionality of signals dangers specified by DIN VDE1) 0833 every organization. One such process is the (danger of fire and intrusion/hold-up) in con- security process. junction with general dangers in the factory (technical dangers) and averts damage by The security process comprises a number of implementing previously conceived measures sub-processes, which are subdivided to a for handling these dangers. It is important that greater or lesser extent, depending on the the alarm and control effect does not only run specification of the key tasks. Process control, in one direction from bottom to top but also which is adapted to every situation, makes a horizontally from subsystem to subsystem in very significant contribution to economically different hierarchical directions. The contribution efficient process planning. This contribution is to economic efficiency is also mainly achieved even greater if you consider the fact that by the combination of different functions in a standard process controls can be designed for single and high-capacity system. The imple- all aspects of security. Uniform structures mentation of these functions traditionally prevent spurious responses in a danger required at least four different systems. situation and simplify daily work with and for the master processes. 1 2 ) DIN (German Industry Standard Association), VDE (Association of German Electrotechnical Engineers)
Links Reliability high degree of availability The fundamental basis of process control is the potential to create logical, complex links from all of the information that is available to a system and to trigger the relevant controls based on these links. The work is in the attention to detail. Prior to system commissioning, every detail of any conceivable danger situation is taken into consideration with the collaboration of the responsible persons. This information is documented and entered into the multifunctional danger alarm system using the system parameter settings. This facilitates the efficient mode of operation of the danger alarm system. Every danger type and every danger combination is related to an appropriate system response which can be relied upon to make the right decision at all times. The situation-specific evacuation of a building can also be implemented without triggering a high level of panic as well as the deactivation of manufacturing processes or the disconnection of the power supply without any data loss of a data processing system. Emergency services are also notified, irrespective of whether this involves company backup forces or public emergency services. All of these processes are regulation-compliant, reliable and fast. A danger alarm system is responsible for providing security in a company and for this exact reason it must possess an extremely high level of security itself. Cerberus D100 has been designed with this in mind. A number of security systems operate in parallel. A special concept has been designed to prevent the failure of operating devices. If an operating panel should become inoperable, responsibility is immediately transferred to another operating panel. All components in the system from the field level (sensors and actuators) to networking are monitored at all times. A component failure, an interruption of the connection lines or a software error is detected immediately and bypassed by implementing suitable measures. This makes all significant elements of Cerberus D100 intelligent, redundant and fail-safe components. 3
Networking Groundbreaking operation Operation is a key function of all process controls. This applies, in particular, to danger alarm systems that have to cope with the high stress load of users in a danger situation. New ground has been broken with the Cerberus D100 operating panel. The ergonomic design was handed over to experts. The design of this new operating A danger alarm system is not alone in a panel incorporates not just standards and building. An efficiently functioning danger guidelines or technology but also the user alarm system should also be able to commu- and his or her natural responses. nicate with all other equipment specific to the building. For example, the forwarding of The color touch screen represents the center alarm information using telecommunications of the operating panel. Logically arranged equipment is a practical idea. Another practical and colored self-explanatory buttons display benefit is the provision of an operating control all information about the entire system. An center with all relevant data for handling the extensive keypad is available for frequent and associated commands just as the input of all experienced users. control center-relevant data into an operating control center for handling the associated In addition to its operation in the security commands. The efficient internetworking of alarm control and indicating panel or its the system components is also an integral part operation at a remote location away from the of a danger alarm system in addition to system cabinets, the DT1000 can also be communication with external components. operated via the Intranet. This feature is Since the existing line network laid throughout particularly interesting for remote functions or a company site is a considerable economic for informing security officers at different factor, the networking of the danger alarm locations. system must be adapted to this existing network. The BF88 operating panel and the SOP-Net network operating panel are available in addition to the new DT1000 system operating panel. 4
System modernization Existing security alarm systems of the SM88 type with an SDN security dialog network (with BMS or IMS control and indicating panels) - SIGMASYS can be updated completely via Cerberus D100. The existing system remains unchanged; only the branches are updated with new functions. If, for example, you want to expand a system by adding modern system components, the entire system can be retained. The key kernels are upgraded from SM88 to D100 and the modern SIGMASYS system components can be connected. The entire system runs as usual in the existing components and has the full functionality of a modern danger alarm system within the framework of Cerberus D100 and SIGMASYS parts. Therefore, your investment in a danger alarm system is guaranteed for the long term. 5
Networking The networking of system technology is of however, is their particularly high degree of central importance for larger systems. The failure safety. The choice of a network arranged multifunctional danger alarm system D100 in tree structures is, therefore, practical for combines the particularly fail-safe (bi-directional) large surface networks. Failure safety is loop network from the SIGMASYS system guaranteed by redundant lines. world with the highly efficient network structure of the SM88 security alarm system. The highly efficient network allows 99 participants to be interconnected. This allows The amount of data and the equipping of the modern security networks to be implemented loops with processing units are limited due to for the first time. The networks can also be the high data load on bi-directional loop logically linked across company locations via networks. The advantage of loop networks, modems. Structure The Cerberus D100 is a danger alarm system with a modular system structure. All components utilized are adapted to the local conditions and only include those components that are required for fulfilling the individual task. Modules are provided for connecting the individual alarm or control peripherals. Like the existing modules, these modules are inserted into the slots of the basic system. 6
Technical data Power supply Power consumption 115 V / 230 V AC +10% / 15%; 50 Hz or 60 Hz 750 V A System voltage 24 V DC (22 V to 29 V) Max. available system power 5 A /10 A /15 A / 20 A /40 A, depending on system configuration Emergency batteries, buffered 2 x 12 V/40 Ah or 65 Ah Temperature range 0 C to +30 C Air humidity No moisture condensation Indoor atmosphere according to DIN 50019 Protection class IP 40 Heat dissipation from control and indicating Planning values: panel to the environment D100 III floor cabinet: approx. 200 W Dimensions in mm (H x W x D): D100 floor cabinet 2200 x 600 x 425 (without side panels) D100 floor cabinet 2200 x 620 x 425 (with side panels) Cabinet color Ergo gray Weight of D100 floor cabinet Approx. 250 kg (configuration-specific) Up to 99 participants Participants in the system: SIGMASYS-C and M control and indicating panels, SIGMASYS-M modules, SIGMANET operating panels, D100 modules (S-modules), SM88 kernels Max. no. operating panels D100-K01 4 x Cerberus DT1000 or 8 x BF88 Max. no. operating panels per subkernel 4 x BF88 or Cerberus DT1000 Connectable per S-module Max. 8 participants (S- and/or M-modules) Max. 8 SIGMANET (in all levels) Max. no. participants/sigmanet Max. 16, for connection to level 1 ( K01 ) Max. 08, for connection to level 2 ( K10 ) Max. 02, for connection to level 3 ( K11 ) Standards and guidelines All relevant standards and guidelines such as EN, DIN (German Industry Standard) and VdS (Association of German Underwriters) have been met. Order specifications Designation Order number Notes Floor cabinet DC1010 S24236-C1-A1 Ready for module installation S-module DC1002 M-module DC1001 Options module S24236-B5-A1 S24236-B6-A1 S24236-B7-A1 GMA-BF DT1000 S24236-F4-A1 D100 system operating panel GMA-BF DT1000 S24236-F17-A1 For SIGMASYS connection GMA-BF DT1000 WEB S24236-F30-A1 D100 sytem operating panel incl. WEB functionality GMA-BF DT1000 WEB S24236-F31-A1 For SIGMASYS connection incl. WEB functionality Power supply module V24230-Z6-A1 Max. 3 pieces 24 V/150 W Converter 230 V/ 24 V/ 20 A V24213-Z130-A1 Vacant cabinet DC1020 S24236-C12-A1 Without module support 7
Fire & Security Products Siemens Gebäudesicherheit Issued by Siemens AG I BT DE FS SYS D-81379 Munich http://www.sbt.siemens.com Order No. A24205-A334-B806 Edition 2/03 PA 02030.5 EK 4500000000 2002 2003 www.sbt.siemens.de Delivery subject to availability; right of technical modifications reserved. Printed in the Federal Republic of Germany on environment-friendly chlorine-free paper.