Thru-The-Wall THDC Series R-410A Condensing Units Ton Series

Similar documents
BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

MERIT SERIES Up Flow / Horizontal

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

MODELS B1PA024, 030 AND 036

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

PRODUCT SPECIFICATIONS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MERIT Series R-410A - Upflow / Horizontal

13 GEP A L P - 1 A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

MERIT Series R-410A - Upflow / Horizontal

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

PAJ3. Product Specifications

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

RGE 13 A T - 1 A

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Advance Release September 2009

2 shp 13 lc 1 36 t - 1 a

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

SKYPAK II, 3 Ton Series, gives you a

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

VertiCool Aurora Engineering Guide

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Commercial High-Efficiency Condensing Units

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

R-410A AFFINITY SERIES DEX DEY Ton

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

G34M Bulletin #69/ August 2003

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Installation Instructions

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

WJH4 Product Specifications

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

PAR5. Product Specifications

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

C13-Series Engineering Guide

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

PACKAGE AIR CONDITIONER

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL SPECIFICATIONS

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Your safety and the safety of others are very important.

ENGINEERING SPECIFICATIONS

Bosch BVA Series Air Handler

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. FH4A Fan Unit. Sizes 001 thru 004

ENGINEERING SPECIFICATIONS

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Product Data. FH4A Fan Unit. Sizes 001 thru 004

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

General Description. Operation

MAC N-407 Air-Cooled Chiller

SKYPAK II, 3 Ton Series, gives you a

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Supersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)

TECHNICAL SPECIFICATIONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL SPECIFICATIONS

WAHL A Product Specifications

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

INSTALLATION INSTRUCTIONS

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Call us today! (800)

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

CB X 32 mv

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

SKYPAK II Heating & Cooling Self Contained Packages

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

T P A 120 S 4 S N 1 Y

Transcription:

Thru-The-Wall THDC Series R-410A Condensing Units 3-4-5 Ton Series

M-Series Cabinet Available In 3 / 4 / 5 Ton M - SERIES FRONT VIEW STANDARD DESIGN High Efficiency Scroll Compressor Advanced Coil Design Over Sized Direct Drive Blowers Two Screw Blower Slide Out CNC Punched Safety Screen / Powder Coat Non Corrosive Hardware Powder Coated Cabinet Standard / LX Series M - SERIES INSIDE VIEW Model Wide High Deep EER BTU THDC-36MG Standard or LX 42 23 18-1/2 12.1 36,800 THDC-48MG Standard or LX 42 23 18-1/2 12.1 49,300 THDC-60MG Standard or LX 42 23 18-1/2 12.1 60,900 Electrical Voltage AWG Wire Motor FLA MCA Max Fuse THDC-36MG21 208-230/1/60 10 4.3 26.7 40 AMP THDC-36MG23 208/3/60 12 4.3 20.8 30 AMP THDC-36MG43 460/3/60 14 3.4 11.7 15 AMP THDC-48MG21 208-230/1/60 10 4.3 31.6 50 AMP THDC-48MG23 208/3/60 10 4.3 21.4 35 AMP THDC-48MG43 460/3/60 14 3.4 11.2 15 AMP THDC-60MG21 208-230/1/60 8 4.3 39.7 65 AMP THDC-60MG23 208/3/60 10 4.3 28.3 45 AMP THDC-60MG43 460/3/60 14 3.4 15.5 25 AMP CHECK YOUR STATE AND LOCAL BUILDING CODES BEFORE EVERY INSTALLATION FOR ELECTRICAL REQUIREMENTS.

Model Standard / LX Series Blower Discharge Weight Compressor Liquid / Vapor THDC-36MG Top 300 lbs. Scroll 1/2" / 3/4" THDC-48MG Top 300 lbs. Scroll 1/2" / 3/4" THDC-60MG Top 325 lbs. Scroll 1/2" / 7/8" Electrical Motor Motor HP Compressor RLA Compressor LRA THDC-36MG21 4.3 1/2 17.9 112 THDC-36MG23 4.3 1/2 13.2 88 THDC-36MG43 3.4 1/2 6.0 44 THDC-48MG21 4.3 1/2 21.8 117 THDC-48MG23 4.3 1/2 13.7 83.1 THDC-48MG43 3.4 1/2 6.2 41 THDC-60MG21 4.3 1/2 30.1 158 THDC-60MG23 4.3 1/2 20.5 155 THDC-60MG43 3.4 1/2 9.6 75 *AeroSys THDC series units are compatible with most indoor air handlers. All specifications are subject to change without notice. LX SERIES ADDED FEATURES M - SERIES LX INSIDE VIEW High / Low Pressure Switches Low Ambient Speed Control (Down To 20⁰) 4 lbs. Acoustical ArmaFlex Lined Cabinet Vibration Eliminators (Liquid & Suction) Heavy Duty Compressor Sound Blanket M - SERIES LOUVER WITH ATTACHED WALL SLEEVE

AeroSys Cross Reference List Brand Model Wide High Type AeroSys Model Dunham-Bush WCR-18/24/30 30 24 Condensing R Size Dunham-Bush VCR-24 30-5/8 29-1/2 Condensing R Size Dunham-Bush VCR-30 36-1/4 29-1/2 Condensing R Size Dunkirk DRCU-018/024/030-4010 29-1/2 23 Condensing R Size First Company WCU-18/24/30-CB 29-1/2 23 Condensing R Size First Company WCX-18/24/30-CB 29-1/2 23 Condensing R Size Hydro Therm / Space Pack WCR-18/24/30 30 24 Condensing R Size Johnson / Aire Ease CW-18/24-PR 30 23 Condensing R Size Luxaire ECD-018/024/030-FNA 29 26 Condensing R Size National Comfort Products NCPB-018/024/030-4010 29-1/2 23 Condensing R Size National Comfort Products NCPC-018/024/030-4010 29-1/2 23 Condensing R Size National Comfort Products NCPC-418/424/230-4010 29-1/2 23 Condensing R Size National Comfort Products DSHP-018/024/030-4010 29-1/2 23 Heat Pump R Size Westinghouse SLO-018-024-030 29-1/2 23 Condensing R Size York H1DC-018/024/030 29-1/2 23 Condensing R Size Bryant/Day & Night/Payne 566C-014/018/024/030 26 28-5/8 Condensing S Size Bryant/Day & Night/Payne 566D-014/018/024/030 26 28-5/8 Condensing S Size Bryant/Day & Night/Payne 566E-014/018/024/030 26 28-5/8 Condensing S Size Carrier 38GK-014/018/024/030 26 28-5/8 Condensing S Size Dunham-Bush VCR-24 30-5/8 29-1/2 Condensing S Size Dunham-Bush VCR-30 36-1/4 29-1/2 Condensing S Size Dunkirk DRCU-018/024/030-1010 26 28-5/8 Condensing S Size Dunkirk DSHP-018/024/030-1019 26 28-5/8 Heat Pump S Size First Company WCU-18/24/30-BB 25-3/4 28-5/8 Condensing S Size First Company WCX-18/24/30-BB 25-3/4 28-5/8 Condensing S Size National Comfort Products NCPB-018/024/030-1010 26 28-5/8 Condensing S Size National Comfort Products NCPC-018/024/030-1010 26 28-5/8 Condensing S Size National Comfort Products NCPC-418/424/230-1010 26 28-5/8 Condensing S Size National Comfort Products DSHP-018/024/030-1010 26 28-5/8 Heat Pump S Size National Comfort Products NCHP-018-1019 26 28-5/8 Heat Pump S Size Dunkirk DRCU-018/024/030-3010 23-3/4 32 Condensing T Size EMI VCH-018/024/030 22-3/8 32 Condensing T Size EMI VHH-018/024/030 22-3/8 32 Heat Pump T Size Fedders CWC-018/24B7C 24 32 Condensing T Size Fedders CWC-028-B3C 24 32 Condensing T Size First Company WCU-18/24/30-AB 24 32 Condensing T Size First Company WCX-18/24/30-AB 24 32 Condensing T Size Goodman TWC-18/24/30-1 24 32 Condensing T Size Lennox HWS2A-21-2-FFC 24 34 Condensing T Size Lennox HSW4-24/26/31-FFC 29 34-1/2 Condensing T Size Magic Chef CBW-18/24/30-PRI 24 32 Condensing T Size National Comfort Products NCPB-018/024/030-3010 23-3/4 32 Condensing T Size National Comfort Products NCPC-018/024/030-3010 23-3/4 32 Condensing T Size National Comfort Products NCPC-418/424/230-3010 23-3/4 32 Condensing T Size National Comfort Products DSHP-018/024/030-3010 23-3/4 32 Heat Pump T Size National Comfort Products NCHP-018/024/030-3019 23-3/4 32 Heat Pump T Size Rheem CBW-18/24/28-B1Q 24 32 Condensing T Size Rheem CBW-18/24/28-B1C 24 32 Condensing T Size Accepted For Use City of New York Department of Buildings MEA 85-04-E THDC-M R090214 Listing # 4008574 Complies with UL 1995 Heating & Cooling Equipment 929 Eldridge Drive Hagerstown, MD 21740 P; 301.620.0002 F: 301.620.0685 www.aerosysinc.com e-mail: asinfo@aerosysinc.com

Bulletin 20-25 / April 2011 Electric Furnace Features Galvanized insulated sheet metal cabinet enclosure Can be converted to a duct heater Magnetic de-energizing contactors for each element Line level auto limit primary safety set @ 165ºF (74ºC) Line level fuse link back-up safety Fan interlock control, fan signal proving switch Low air flow pressure switch Circuit breakers on all units Time delay sequencers for a gradual stepped power draw (softer start) Low voltage terminal strip (24 volt control) Specially designed tight cabinet for small duct, high velocity systems Single Supply (all units) or dual supply (15 and 20kW) General The electric furnaces are designed to provide primary heating or auxiliary heating in a heat pump system. The model numbers, kw, and Unico System match-ups are shown in Table 1 below: Table 1. Electric Furnaces Model Number Nominal kw Rating WON0202-B 2 WON0502-B WON0504-B WON0752-B WON0754-B WON1002-B WON1004-B WON1502-B WON1504-B Unico System Match-up Airflow, CFM (m 3 /s) 200 (0.10) 5 250 (0.12) All sizes 7.5 300 (0.14) 10 500 (0.24) 2430, 3642 and 4860 15 600 (0.28) WON2002-B 20 3642 and 4860 800 (0.38) Specifications WON0502-B Revision level 2-Single-Phase,240V 4-3-Phase,240V Nominal kwrating (050 = 5 kw) All Unico System furnaces include a 10-inch (254-mm) round plenum adapter and a 9½ 9½-inch (241 241-mm) square plenum adapter. CONFORMS TO UL STD 181 CERTIFIED TO CAN/ULC STD S110-M86 Other plenum adapter sizes are available separately. See the electric furnace installation instructions Bulletin 30-34 for a list of plenum adapter part numbers. See Figure 1 and Table 1 for the dimensions on all furnaces. Ø10.0in TOP VIEW L AIRFLOW 81037 12.0 in 4.0 in 12.0 in END VIEW SIDE VIEW 10.0 in. Round plenum adapter shown attached (Supplied). Optional: 9.5 in. x 9.5 in. square plenum adapter (Supplied) is shipped loose. IL00002(Rev D).cvx Figure 1. Electric Furnace dimensions. Table 1. Electric Furnace dimensions & specifications Model WON0202-B WON0502-B L inch 13 13 Rated Capacity kw @240V Amperage @ 240V The electric duct furnace is approved for attic, closet, or alcove installation, with 0 clearance to combustible materials. It can 2.0 4.8 8.30 20.00 WON0752-B 16 7.2 31.25 WON1002-B 16 9.6 40.00 WON1502-B 21 14.4 60.00 WON2002-B 24 19.2 80.00 WON0504-B 21 4.8 11.54 WON0754-B 21 7.2 18.04 WON1004-B 21 9.6 23.09 WON1504-B 21 14.4 34.64 Copyright 2011 Unico, Inc.

Bulletin 20-25 Page 2 be mounted either directly to the blower module or in the main duct. See Figure 2. Main Plenum 24.0" Main Plenum AIRFLOW Electric Heater Electric furnace application AIRFLOW Electric Heater Duct heater application 24.0" 48.0" Main Plenum Blower module Blower module IL00491.cvx Figure 2. Minimum duct clearance for electric heater applications. Allow at least 25-inches (610-mm) in front of the control for servicing. For high humidity applications and other important information, see the electric furnace installation instructions Bulletin 30-34. For limits and set points, see Table 2. For further specifications, Table 3. Furnace Specifications Model Nom. Capacity, kw Rated Output*, kw Power Supply see Table 3. The 15 and 20 kw single phase furnaces contain two supply circuits. Supply wires can be run separately for each circuit, which is the default configuration. Using two supply circuits allows the use of smaller gauge wires. In some cases, it is necessary to use smaller gauge wire to comply with building codes that limit the maximum wire size that can be used for a single circuit. The required wire size for each electric furnace is shown in Table 3. The two circuits can also be joined together with a jumper bar. This is included with all dual circuit furnaces. The jumper bar allows the use of one pair of larger gauge wire, as opposed to two pairs of smaller gauge wire. Note: Circuit breakers installed in this device are for shortcircuit protection of internal wiring and to serve as a service disconnect. Circuit breakers installed within this device DO NOT provide over current protection of the supply wiring. Specifications Maximum Outlet Temperature, o F ( o C) 160 (70) Maximum External Static Pressure, in. wc (Pa) 3 (745) Auto Limit set point, o F ( o C) 165 (74) Fuse Link Setting, o F ( o C) 250 (121) Table 2. Limits and set points No. of Supply Circuits No. Steps Control Power (VA) Overall Dimensions, inch WON0202-B 2 2.0 1 ph 60 Hz 240V 1 1 20.5 12 H x 16 W x 13 L WON0502-B 5 4.8 1 ph 60 Hz 240V 1 1 20.5 12 H x 16 W x 13 L WON0752-B 7.5 7.5 1 ph 60 Hz 240V 1 2 31.0 12 H x 16 W x 16 L WON1002-B 10 9.6 1 ph 60 Hz 240V 1 2 31.0 12 H x 16 W x 16 L WON1502-B 15 14.4 1 ph 60 Hz 240V 1 or 2 3 42.5 12 H x 16 W x 21 L WON2002-B 20 19.2 1 ph 60 Hz 240V 1 or 2 3 42.5 12 H x 16 W x 24 L WON0504-B 5 4.8 3 ph 60 Hz 240V 1 1 20.5 12 H x 16 W x 21 L WON0754-B 7.5 7.5 3 ph 60 Hz 240V 1 1 20.5 12 H x 16 W x 21 L WON1004-B 10 10 3 ph 60 Hz 240V 1 1 20.5 12 H x 16 W x 21 L WON1504-B 15 15 3 ph 60 Hz 240V 1 2 31.0 12 H x 16 W x 21 L Model Single Supply Dual Supply (1 Circuit/ 2 Circuit) Heater Max. Fan Circuit Ampacity Max. Overcurrent Protection Req d Wire Size WON0202-B 8.3 6.5 18.5 20 12 Heater Max. Fan Circuit Ampacity Max. Overcurrent Protection WON0502-B 20 6.5 33.1 35 10 WON0752-B 31.25 6.5 47.2 50 8 WON1002-B 40 6.5 58.1 60 6 WON1502-B 60 6.5 83.1 90 3 40/20 ---/6.5 50/33.1 50/35 6/8 WON2002-B 80 6.5 108.1 110 2 40/40 6.5/--- 58.1/50 60/50 6/6 WON0504-B 11.54 6.5 22.6 25 10 WON0754-B 18.04 6.5 30.7 35 8 WON1004-B 23.09 6.5 37 40 8 WON1504-B 34.6 6.5 51.4 60 6 *at rated voltage FUSE or HACR TYPE Circuit Breaker Based on 75 C copper. For other wire types reference NEC Req d Wire Size Copyright 2011 Unico, Inc.