INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Similar documents
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS DRY BAIN MARIE

FWC860 Wine Cooler Installation, Use and Maintenance

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog

INSTRUCTION MANUAL (ATEX / IECEx)

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Streamline Undersink. Fitting Instructions and User Guide

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

Hazardous Area Portable Fan Heater The Bulldog

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

FWC153, FWC304, FWC604 & FWC624

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTIONS MODEL: MWBT

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

CFP4, 8 or 12 Exde Immersion Heater. CERTIFIED TO IEC :2000, IEC :2001 and IEC :2001

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Technical Manual for the Alarm Pull Station PH1

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX)

Technical Specification VFD

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

LTFX Electric Tank Immersion Heaters Installation Instructions

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

4) Intrinsic Safety Certification

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Operating Manual Distribution box

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTIONS NACHO WARMER MODELS: 1995 / 1995S

User s Manual YTA610 and YTA710 NEPSI Certification

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Closomat Lima Vita installation & user guide

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

O p e r a t i n g I n s t r u c t i o n s

HEAT. Industrial Ltd. Standard Products

Installation, Operating and Servicing Instructions

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Earth-Rite II PLUS Static Earthing System

Inta City Concealed Shower Mixing Valve CT80010CP

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

EXHEAT Industrial Standard Products

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Installation, operating and servicing instructions

RFM Series RFM-ISR Barrier. Installation Manual

Snifter ATEX22 VERSION. User Manual. Distributor

Manual Power relay SR853

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Limit Switch Box YT-870/875 SERIES

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INSTRUCTIONS MODEL: CBM / CMB2

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Installation and Wiring Instructions

Survey of electrical equipment installed in hazardous areas on tankers

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Mix Boiler & Font Range ( #, #, #, , )

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

OPTIBAR DP 7060 Supplementary Instructions

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

HOT CUPBOARD WITH BAIN MARIE

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

PARAGON FRYERS INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: PF9 MODEL: PSF3 MODEL: PSPF9 MODEL: PDPF6 MODEL: PDPF9

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Certificate of Compliance

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

INSTRUCTIONS MODEL: BT1 MOBILE BANQUETING TROLLEY

Technical Manual for the Horn DB1P UL DB1HP UL

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

Enzo Concealed Shower Mixing Valve

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

Instruction manual. Remote control electric IR HEATER

WATLOW ELECTRIC MANUFACTURING COMPANY

805QS Pressure Switch-Transmitter

Thermostatic mixing valves with interchangeable cartridges

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Whole Room Dryer WRD, WRD/110

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves


Transcription:

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1

1.0 GENERAL 1.1 All work should be carried out by suitably qualified personnel. 1.2 Equipment must be handled with care and stored in dry conditions. 1.3 CAUTION these radiators are heavy and must be handled appropriately: 50kg FLR1 100kg FLR2 150kg FLR3 1.4 Carefully remove all protective packaging and visually inspect unit for any transit damage. 1.5 All prevailing rules, regulations and bylaws in force at the time and place of installation must be observed. 1.6 Any modification not carried out by Exheat Limited or its approved agent will invalidate certification and warranty. 1.7 This is a hazardous area heater. Reference must be made to EN 60079-17 & IEC 1241-1-2. 1.8 All electrical testing must be carried out in a non-hazardous area. 1.9 Precautions must be taken to prevent damage to machined surfaces and threads of flameproof enclosures. 1.10 Ensure that any special conditions for safe use detailed on the hazardous area certification are complied with. 1.11 CAUTION the liquid within the radiator contains glycol and must not be consumed. Should a leak occur the heater must be de-energised immediately and returned to Exheat for repair. Any leaks must be cleared up with care and hands washed immediately after contact. 2.0 INSTALLATION 2.1 The radiator should be securely fixed in position with the wall brackets supplied and all terminal connections checked for tightness before energising. 2.2 The correct installed orientation is with the heater lowermost in the radiator. 2.3 The installer or end user shall ensure that the unit has free and unrestricted air flow to allow natural convection to occur at all times. DO NOT COVER the radiator and do not allow anything to rest on or against it. 2.4 At no time is the ambient temperature to be allowed to rise above 40 C. 3.0 ELECTRICAL SUPPLY CONNECTION 3.1 Refer to wiring diagram fig 1. 3.2 The cable entry is positioned on the side of the terminal box. 3.3 Before connection ensure that the supply corresponds with that specified on the rating label. 3.4 Ensure that the sizes and types of cables to be used are suitably rated for the load and temperature of the unit. 3.5 Each heater must be protected by a suitably rated over current device and earth leakage circuit breaker device. See section 4 below for earthing details. 3.6 The cables must enter the heater terminal box via ATEX certified Ex d IIC cable glands (not supplied) and be fitted by a qualified person. Any unused entries should remain plugged with the factory fitted certified Ex d plugs. 3.7 The cover of the terminal box is removed after releasing the 3 socket head screws in the cover. When re-fitting ensure that the o ring seal is in good condition and correctly located. The main cover mating and spigot faces MUST be kept clean and free from any debris at all times. 3.8 After re-fitting, the gap between the cover and the body must be checked to ensure that it does not exceed 0.15mm. 2

3.9 The installer or end user must connect to the Exheat supplied terminals within the terminal box - DO NOT connect to or disturb factory fitted wiring. 4.0 EARTH CONNECTION 4.1 WARNING these heaters MUST BE EARTHED. 4.2 The external earth connection is located adjacent to one of the terminal box cable entries. 4.3 An internal earth connection is provided inside the terminal box. 5.0 OPERATION 5.1 Heat is generated by means of electric heating elements. 5.2 An adjustable control knob is provided on the terminal box sensing ambient air temperature. Rotate clockwise to increase the desired set-point or anti-clockwise to reduce the set-point. 5.2 Temperature control of the radiator is limited by a built-in preset thermostatic cut-out (autoreset type). 5.3 Over-temperature control of the radiator is facilitated by a built-in preset thermostatic cut-out (manual-reset type). Upon over-temperature, the terminal box cover will have to be removed to enable a reset to be carried out. The unit should not be reset until the cause is found and action has been carried out to prevent re-occurrence. 5.4 CAUTION under no circumstances must the heater be energised following leakage of any fluid from within the radiator. 6.0 MAINTENANCE 6.1 All prevailing site safety regulations shall be adhered to at all times. 6.2 Equipment shall be checked regularly for any dust accumulation which must be removed from all surfaces. 6.3 Before and whilst any maintenance activity is carried out, it must be ensured that there are no hazardous gases or dusts present. 6.4 Equipment is to be fully isolated from the electrical supply before and whilst any work is being carried out. 6.5 Any damage or faults should be notified to Exheat Limited immediately. 6.6 Any replacement parts required must be obtained directly from Exheat. The use of any other parts will void any certification and warranty. 6.7 Equipment is certified for use in a hazardous area and reference should be made to EN60079-17 (especially table 1) & IEC 1241-1-2 in addition to the following recommendations. 6.7.1 3 Monthly a. Generally inspect the equipment for external damage or leaks. 6.7.2 6 Monthly a. Isolate the electrical supply and remove the cover (refer to 3.7 above) b. Internals should be clean and dry. c. Ensure terminals are intact and secure. d. Heating element insulation resistance to be at least 2 megohm. e. Refit cover with new gasket or o ring if required (refer to 6.6 above) and re-tighten using only the socket head screws provided. f. Check the flamepath gap as 3.8 above. g. Earth continuity must be maintained between all earth points and main structure. 3

6.7.3 Annually a. Carry out 3 monthly and 6 monthly checks as above. b. Check for element failure or low insulation resistance. 6.8 Only Exheat Ltd or its approved agent to carry out rod type element replacement in hazardous area heaters otherwise the certification will be invalidated. 6.9 If equipment is being left unused for a period greater than 3 months, carry out 6 monthly maintenance before energizing. 6.10 If for any reason the heater element assembly has to be removed from the radiator, the following re-filling procedure should be followed, prior to energizing. a. Empty the liquid content of the radiator and discard. (Care should be taken to ensure that disposal of this liquid complies with prevailing environmental laws). b. With heater fitted, and filler connection plug removed, add one litre of glycol-based anti-freeze to each kilowatt of power produced by heater (The kilowatt rating of the unit can be found on the terminal box lid). c. With the radiator positioned horizontally, re-fill the radiator with water to a level just below the height of the filler connection. d. Replace and tighten the filler connection plug. e. Check for leaks and follow installation instructions in section 2. 7.0 Marking 7.1 II 2 G Ex d IIC T6 Ex td A21 IP6X T85 C 8.0 Certification 8.1 LCIE 00 ATEX 6012 X 4

Fig 1. Fig 1. ADJUSTABLE AIR TEMPERATURE CONTROL MANUAL RESET OVERTEMPERATURE HEATER ELEMENT INTERNAL EARTH AUTO RESET L N E E EXTERNAL EARTH L N E CLIENTS INCOMING SINGLE PHASE & EARTH SUPPLY FLR SERIES HEATER WIRING DIAGRAM EXHEAT LTD Threxton Road Industrial Estate Watton, Thetford, IP25 6NG Tel: +44 (0)1953 886200 Fax: +44 (0)1953 886222 For sales and new product information see our website www.exheat.com 73/23/EEC 89/336/EEC 94/9/EC Stock Code S090.00.0000.0018 Issue F 5