LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Similar documents
Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Air-Cooled Condensing Units with Compact Screw Compressors

horizontal air discharge outdoor discus condensing unit

Kramersaver Air Cooled Condensing Units

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

3-22 HP CONDENSING UNITS Technical Guide

Air-Cooled Condensing Units with Bitzer Compressors

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Center Mount Unit Coolers

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Air-Cooled Condensers

WCH5**4. Product Specifications

Commercial High-Efficiency Condensing Units

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

ThermoSaver TM Hot Gas Defrost System

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

R4H4. Product Specifications

N4H4. Product Specifications

R4H4. Product Specifications

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

MACH N-407 Heat Pump Air-Cooled Chiller

Low Flow Unit Coolers

Slim Contour Unit Cooler

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Specifications and Performance S2H

VertiCool Aurora Engineering Guide

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Super-Flo Low Profile Unit Cooler

Low Profile Unit Coolers

Installation Manual BCS2000/3000

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Condensing Units w/ Screw Compressors

MAC N-407 Air-Cooled Chiller

Installation Manual BCS 1000/1500

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Chillers A P P L I C AT I O N S

500 EX Fusion Compressor Series

Kirby Commander Condensing Unit

CoolSpot Engineering Guide

Commercial High-Efficiency Condensing Units

MCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers

Air-Cooled Condensers

30GN FLOTRONIC II AIR-COOLED CHILLERS

Low Profile Unit Coolers

ThermoSaver TM Hot Gas Defrost System

Packaged refrigeration system Technical Guide

30GT FLOTRONIC AIR-COOLED CHILLERS

LOW PROFILE UNIT COOLER

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

Optyma Slim Pack Condensing Units

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

MiniLine Air Cooled Condensing Units -1/2 to 6 HP

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

ENGINEERING SPECIFICATIONS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

ENGINEERING SPECIFICATIONS

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

ENTHALPY TD SERIES CONDENSING UNITS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

High Profile Evaporator

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

ENTHALPY HERMETIC CONDENSING UNITS

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

C13-Series Engineering Guide

MODELS W1LC220, 260 AND 320 STYLE B

Call us today! (800)

Condensing Unit Installation and Operating Instructions

LOW PROFILE UNIT COOLER

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Copeland Scroll Outdoor Refrigeration Unit

Product Data. Split System Cooling D-EN. August 2016

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

Concealed Ducted Split Series R-407C MBH

TLV Low Velocity Evaporators

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Energy Use in Refrigeration Systems

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

REPAIR PARTS. GSZ14 R-410A Remote Heat Pumps GSZ140181AA GSZ140241AA GSZ140301AA GSZ140361AA GSZ140421AA GSZ140481AA GSZ140601AA

PRO 3 TOP MOUNT & SIDE MOUNT PACKAGED REFRIGERATION SYSTEMS Technical Guide

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Transcription:

LK-TSSTB July 2009 FPO 5-30 HP Two Stage Condensing Units and Systems Technical Guide with Bitzer s www.larkinproducts.com

Table of Contents Standard Features... 2 Nomenclature... 2 Condensing Unit Capacity... 3 Two Stage System Capacity... 4 Two Stage Electrical Specifications... 5 Physical Specifications... 6 Dimensional Diagrams... 6 Piping Diagram... 7 Standard Features Condensing Unit Bitzer two stage compressor Discharge and suction vibration eliminators Discharge muffler Encapsulated high pressure switch Adjustable low pressure switch with superhose Crankcase heater contactor w/circuit breaker Floating Tube coil design Flooded head pressure controls Pressure fan cycling (multiple fan units) Oil separator - return line solenoid valve and time delay Mechanical subcooler Replaceable core liquid line filter drier Replaceable core suction filter Suction accumulator Crankcase pressure regulator Defrost timer Evaporator fan contactor with fusing Defrost heater contactor with fusing Anti short cycle timer Phase monitor Pumpdown switch Evaporator Thermo-Flex coil design Thermostatic expansion valve factory installed Liquid line solenoid valve factory installed Low temperature motors Double wall insulated drain pan Adjustable defrost termination and fan delay Nomenclature L C L = Larkin C = Compound U Unit Construction R = Remote Condenser U = Attached Condenser (Unit) 1 Comp. Qty. 005 Total Comp. HP 005 = 5 HP 008 = 8 HP 012 = 12 HP 016 = 16 HP 020 = 20 HP 025 = 25 HP 030 = 30 HP A Condenser A = Air W = Water B Control Voltage E Defrost X Temp. Range 6 Refrigerant A = 115/1/60 E = Electric X = Ultra 6 = R-404A/ B = 208-230/1/60 Low R-507 D Unit Voltage 2 Application C = 208-230/3/60 1 = Indoor D = 460/3/60 2 = Outdoor 2009 Heatcraft Refrigeration Products, LLC

Condensing Unit Capacity Two Stage Unit LCU1005ABEX6*2 LCU1008ABEX6*2 LCU1012ABEX6*2 LCU1016ABEX6*2 LCU1020ABEX6*2 LCU1025ABEX6*2 LCU1030ABEX6*2 S4T-5.2Y S4N-8.2Y S4G-12.2Y S6J-16.2Y S6H-20.2Y S6G-25.2Y S6F-30.2Y Suction 90 F 95 F 100 F 105 F 110 F Temp. F -40 18,730 18,450 18,170 17,900 17,640-45 16,520 16,260 16,000 15,740 15,490-50 14,500 14,260 14,010 13,770 13,530-55 12,650 12,420 12,190 11,960 11,740-60 10,960 10,740 10,520 10,310 10,100-65 9,410 9,200 9,000 8,800 ** -40 26,600 26,200 25,800 25,400 25,000-45 23,500 23,100 22,800 22,400 22,000-50 20,600 20,300 19,960 19,610 19,240-55 18,030 17,710 17,390 17,050 16,700-60 15,630 15,340 15,030 14,710 14,380-65 13,440 13,150 12,860 12,560 ** -40 42,500 41,800 41,100 40,400 39,700-45 37,800 37,100 36,500 35,900 35,300-50 33,400 32,800 32,300 31,700 31,200-55 29,300 28,800 28,300 27,800 27,300-60 25,600 25,100 24,700 24,200 23,700-65 22,100 21,700 21,300 20,800 ** -40 59,500 56,800 57,600 56,700 55,700-45 53,100 52,200 51,300 50,500 49,600-50 47,100 46,300 45,500 44,700 43,900-55 41,500 40,800 40,100 39,400 38,600-60 36,300 35,700 35,100 34,400 33,700-65 31,600 31,000 30,400 29,700 ** -40 68,700 67,600 66,400 65,300 64,200-45 61,300 60,200 59,200 58,200 57,200-50 54,300 53,400 52,500 51,600 50,700-55 47,900 47,100 46,300 40,500 35,100-60 42,000 41,200 40,500 39,700 38,900-65 36,500 35,800 35,100 34,400 ** -40 78,500 77,100 75,800 74,500 73,200-45 70,000 68,800 67,600 66,400 65,200-50 62,100 61,000 60,000 58,900 57,800-55 54,800 53,800 52,900 51,900 50,900-60 48,000 47,200 46,300 45,400 44,400-65 41,800 41,000 40,200 39,300 ** -40 93,000 91,400 89,700 88,100 86,500-45 83,000 81,600 80,100 78,700 77,200-50 73,700 72,400 71,200 69,900 68,600-55 65,100 64,000 62,800 61,700 60,400-60 57,100 56,100 55,100 54,000 52,800-65 49,700 48,800 47,800 46,800 ** NOTE: All capacities listed include liquid subcooling and are based upon sea level elevation pressure. * C for 208-230/3/60, D for 460/3/60 ** Out of Application Range 3

Two Stage System Capacity -40º F Room Unit Evaporator 90 F TD 95 F TD 100 F TD 105 F TD 110 F LCU1005ABEX6*2 S4T-5.2Y MLT4 220 13,871 9.7 13,683 9.6 13,489 9.4 13,299 9.3 13,112 9.2 LCU1008ABEX6*2 S4N-8.2Y MLT4 330 19,935 9.3 19,689 9.2 19,419 9.1 19,138 8.9 18,842 8.8 LCU1012ABEX6*2 S4G-12.2Y MLT4 530 32,277 9.4 31,812 9.2 31,407 9.1 30,936 9.0 30,528 8.9 LCU1012ABEX6*2 S4G-12.2Y LHL4 560 32,613 9.0 32,137 8.8 31,727 8.7 31,245 8.6 30,833 8.5 LCU1016ABEX6*2 S6J-16.2Y LHL4 710 45,112 9.8 44,495 9.6 43,873 9.5 43,247 9.4 42,596 9.2 LCU1020ABEX6*2 S6H-20.2Y LHL4 840 52,283 9.6 51,578 9.4 50,868 9.3 49,311 9.0 48,147 8.8 LCU1025ABEX6*2 S6G-25.2Y LHL4 1050 60,778 8.9 59,885 8.8 59,070 8.7 58,168 8.5 57,262 8.4 LCU1030ABEX6*2 S6F-30.2Y LHL4 1220 71,871 9.1 70,834 8.9 69,843 8.8 68,793 8.7 67,716 8.5 TD -50º F Room Unit Evaporator 90 F TD 95 F TD 100 F TD 105 F TD 110 F LCU1005ABEX6*2 S4T-5.2Y MLT4 220 10,699 8.8 10,525 8.7 10,351 8.6 10,184 8.4 ** LCU1008ABEX6*2 S4N-8.2Y MLT4 330 15,414 8.5 15,181 8.4 14,932 8.2 14,674 8.1 ** LCU1012ABEX6*2 S4G-12.2Y MLT4 530 25,159 8.6 24,763 8.5 24,439 8.4 24,034 8.2 ** LCU1012ABEX6*2 S4G-12.2Y LHL4 560 25,422 8.3 25,017 8.1 24,689 8.0 24,280 7.9 ** LCU1016ABEX6*2 S6J-16.2Y LHL4 710 35,318 9.0 34,835 8.9 34,351 8.8 33,787 8.7 ** LCU1020ABEX6*2 S6H-20.2Y LHL4 840 41,031 8.9 40,397 8.7 39,829 8.6 38,608 8.4 ** LCU1025ABEX6*2 S6G-25.2Y LHL4 1050 47,649 8.3 47,023 8.1 46,283 8.0 45,540 7.9 ** LCU1030ABEX6*2 S6F-30.2Y LHL4 1220 56,482 8.4 55,668 8.3 54,846 8.2 53,943 8.0 ** NOTE: All capacities listed include liquid subcooling and are based upon sea level elevation pressure. * C for 208-230/3/60, D for 460/3/60 ** Out of Application Range TD 4

Two Stage Electrical Specifications -40º F Room Unit Condensing Unit Evaporator System Cond. Voltage Fan Fan Defrost Heater Motor MCA MOPD Voltage 60 Hz RLA LRA MCC FLA Amps Voltage Amps 60 Hz 60 Hz 208-230/1 3.6 208-230/3 16.0 28.7 45.0 MLT4 220 LCU1005ABEX6C2 S4T-5.2Y 208-230/3 17.9 150.0 28.0 2.7 LCU1005ABEX6D2 S4T-5.2Y 460/3 9.4 75.0 14.7 1.9 460/1 2.0 460/3 8.3 20.0 25.0 LCU1008ABEX6C2 S4N-8.2Y 208-230/3 25.1 180.0 39.2 5.4 208-230/1 5.4 208-230/3 23.2 42.2 60.0 MLT4 330 LCU1008ABEX6D2 S4N-8.2Y 460/3 13.2 90.0 20.6 3.8 460/1 3.0 460/3 12.0 23.3 35.0 LCU1012ABEX6C2 S4G-12.2Y 208-230/3 35.9 252.0 56.0 8.0 208-230/1 9.0 208-230/3 34.7 61.9 90.0 MLT4 530 LCU1012ABEX6D2 S4G-12.2Y 460/3 18.8 126.0 29.4 4.0 460/1 5.0 460/3 18.1 32.5 50.0 LCU1012ABEX6C2 S4G-12.2Y 208-230/3 35.9 252.0 56.0 8.0 208-230/3 13.8 208-230/3 35.8 66.7 100.0 LHL4 560 LCU1012ABEX6D2 S4G-12.2Y 460/3 18.8 126.0 29.4 4.0 460/3 6.9 460/3 18.1 34.4 50.0 LCU1016ABEX6C2 S6J-16.2Y 208-230/3 53.8 294.0 84.0 8.0 208-230/3 18.4 208-230/3 47.8 93.7 125.0 LHL4 710 LCU1016ABEX6D2 S6J-16.2Y 460/3 28.3 147.0 44.1 4.0 460/3 9.2 460/3 24.3 48.6 70.0 LCU1020ABEX6C2 S6H-20.2Y 208-230/3 61.0 352.0 95.2 8.0 208-230/3 18.4 208-230/3 47.8 102.7 150.0 LHL4 840 LCU1020ABEX6D2 S6H-20.2Y 460/3 32.1 176.0 50.0 4.0 460/3 9.2 460/3 24.3 53.3 80.0 LCU1025ABEX6C2 S6G-25.2Y 208-230/3 74.4 436.0 116.0 14.0 208-230/3 13.8 208-230/3 64.2 120.8 175.0 LHL4 1050 LCU1025ABEX6D2 S6G-25.2Y 460/3 38.7 218.0 60.3 7.0 460/3 6.9 460/3 32.1 62.3 100.0 LCU1030ABEX6C2 S6F-30.2Y 208-230/3 86.2 490.0 134.4 14.0 208-230/3 19.8 208-230/3 64.2 141.6 225.0 LHL4 1220 LCU1030ABEX6D2 S6F-30.2Y 460/3 45.3 245.0 70.6 7.0 460/3 9.9 460/3 32.1 73.5 110.0-50º F Room Unit Condensing Unit Evaporator System Cond. Voltage Fan Fan Defrost Heater Motor MCA MOPD Voltage 60 Hz RLA LRA MCC FLA Amps Voltage Amps 60 Hz 60 Hz 208-230/1 3.6 208-230/3 16.0 28.7 45.0 MLT4 220 LCU1005ABEX6C2 S4T-5.2Y 208-230/3 17.9 150.0 28.0 2.7 LCU1005ABEX6D2 S4T-5.2Y 460/3 9.4 75.0 14.7 1.9 460/1 2.0 460/3 8.3 20.0 25.0 LCU1008ABEX6C2 S4N-8.2Y 208-230/3 25.1 180.0 39.2 5.4 208-230/1 5.4 208-230/3 23.2 42.2 60.0 MLT4 330 LCU1008ABEX6D2 S4N-8.2Y 460/3 13.2 90.0 20.6 3.8 460/1 3.0 460/3 12.0 23.3 35.0 LCU1012ABEX6C2 S4G-12.2Y 208-230/3 35.9 252.0 56.0 8.0 208-230/1 9.0 208-230/3 34.7 61.9 90.0 MLT4 530 LCU1012ABEX6D2 S4G-12.2Y 460/3 18.8 126.0 29.4 4.0 460/1 5.0 460/3 18.1 32.5 50.0 LCU1012ABEX6C2 S4G-12.2Y 208-230/3 35.9 252.0 56.0 8.0 208-230/3 13.8 208-230/3 35.8 66.7 100.0 LHL4 560 LCU1012ABEX6D2 S4G-12.2Y 460/3 18.8 126.0 29.4 4.0 460/3 6.9 460/3 18.1 34.4 50.0 LCU1016ABEX6C2 S6J-16.2Y 208-230/3 53.8 294.0 84.0 8.0 208-230/3 18.4 208-230/3 47.8 93.7 125.0 LHL4 710 LCU1016ABEX6D2 S6J-16.2Y 460/3 28.3 147.0 44.1 4.0 460/3 9.2 460/3 24.3 48.6 70.0 LCU1020ABEX6C2 S6H-20.2Y 208-230/3 61.0 352.0 95.2 8.0 208-230/3 18.4 208-230/3 47.8 102.7 150.0 LHL4 840 LCU1020ABEX6D2 S6H-20.2Y 460/3 32.1 176.0 50.0 4.0 460/3 9.2 460/3 24.3 53.3 80.0 LCU1025ABEX6C2 S6G-25.2Y 208-230/3 74.4 436.0 116.0 14.0 208-230/3 13.8 208-230/3 64.2 120.8 175.0 LHL4 1050 LCU1025ABEX6D2 S6G-25.2Y 460/3 38.7 218.0 60.3 7.0 460/3 6.9 460/3 32.1 62.3 100.0 LCU1030ABEX6C2 S6F-30.2Y 208-230/3 86.2 490.0 134.4 14.0 208-230/3 19.8 208-230/3 64.2 141.6 225.0 LHL4 1220 LCU1030ABEX6D2 S6F-30.2Y 460/3 45.3 245.0 70.6 7.0 460/3 9.9 460/3 32.1 73.5 110.0 5

PHySICAL Specifications Unit Condensing Unit Evaporator Connections Approx. Receiver Connections (in.) (in.) Dim. (in.) Approx. Capacity Weight @90% Drain Liquid Suct. L W H (lbs.) Liquid Suct. full (lbs.) FPT Approx. Dim. (in.) L W H Approx. Weight (lbs.) LCU1005ABEX6*2 S4T-5.2Y 1/2 1-1/8 33 82 36 40 850 MLT4 220 3/8 1-3/8 3/4 68 23 26 206 LCU1008ABEX6*2 S4N-8.2Y 1/2 1-1/8 67 82 36 40 1,281 MLT4 330 3/8 1-3/8 3/4 96 23 26 294 LCU1012ABEX6*2 S4G-12.2Y 5/8 1-3/8 81 144 45 56 1,980 MLT4 530 3/8 1-5/8 3/4 139 23 26 402 LCU1012ABEX6*2 S4G-12.2Y 5/8 1-3/8 81 144 45 56 1,980 LHL4 560 1/2 2-1/8 1-1/4 106 30 43 469 LCU1016ABEX6*2 S6J-16.2Y 5/8 1-5/8 81 144 45 56 1,980 LHL4 710 1/2 2-1/8 1-1/4 136 30 43 606 LCU1020ABEX6*2 S6H-20.2Y 5/8 1-5/8 81 144 45 56 2,280 LHL4 840 1/2 2-1/8 1-1/4 136 30 43 656 LCU1025ABEX6*2 S6G-25.2Y 5/8 2-1/8 123 171 45 56 2,370 LHL4 1050 1/2 2-1/8 1-1/4 136 42 51 945 LCU1030ABEX6*2 S6F-30.2Y 5/8 2-1/8 123 171 45 56 2,460 LHL4 1220 5/8 (2) 2-1/8 1-1/4 136 42 56 1,019 * C for 208-230/3/60, D for 460/3/60 Dimensional Diagrams 5 HP 5 HP 12 & 16 HP 16 HP 39.16 56.59 81.66 144.00 8 HP 8 HP 25 & 30 HP 30 HP 39.16 56.59 81.66 170.70 6

Piping Diagram 1/4" ACCESS AIR COOLED CONDENSER DRAIN REGULATOR DIFFERENTIAL CHECK ROTO-LOCK PRESSURE RELIEF ROTO-LOCK A.S.M.E RECEIVER LIQUID SOLENOID SIGHT GLASS LIQUID FILTER CHECK VIB ELIM SIGHT GLASS EXPANSION SUB COOLER BALL MUFFLER VIB ELIM VIB ELIM SOLENOID BALL SUCTION FILTER OIL SEPARATOR HIGH PRESSURE SWITCH FAN PRESSURE SWITCH CPR OIL RETURN SOLENOID SIGHT GLASS COMPRESSOR LOW PRESSURE SWITCH SUCTION ACUMULATOR OIL PRESSURE SWITCH FIELD CONNECTION -- SUCTION -------- DISCHARGE ---- LIQUID ----------- INSULATED ----- 7

For more information on Larkin refrigeration products, contact your Sales Representative or visit our web site at www.larkinproducts.com. Mastering the Art of Cold A Brand of Heatcraft Refrigeration Products, LLC 2175 West Park Place Blvd. Stone Mountain, GA 30087 800.848.9889 www.larkinproducts.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice. LK-TSSTB-0709 Version 000