EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Similar documents
Enhancement of COP using Nanoadditives in Domestic Refrigerator

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

EXPERIMENTAL ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOREFRIGERANT

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

A performance study of Vapour compression refrigeration system using ZrO2 Nano particle with R134a and R152a

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

ENHANCEMENT OF HEAT TRANSFER USING NANO-REFRIGERANT. * Corresponding author s

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

Performance Analysis of VCRS with Nano-Refrigerant

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

II. OBJECTIVE OF RESEARCH

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Experimentation of Heat Pipe Used In Nano-Fluids

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Sarthak Thakar, 2 R.P.Prajapati 1

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance of an Improved Household Refrigerator/Freezer

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Modelling of vapour compression refrigeration system (VCRS) by using alternative refrigerants with CuO and without Nano materials

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Evaluation on Exergy Analysis of Vapour Compression Refrigeration System Using LPG with TiO 2 -Nanoparticle

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

Enhancement of COP in Vapour Compression Refrigeration System

Adsorption refrigeration system using waste heat

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

中国科技论文在线 Energy Conversion and Management 52 (2011)

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

DEEPAK PALIWAL, S.P.S.RAJPUT

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

PERFORMANCE INVESTIGATION AND EXERGY ANALYSIS OF VCRS OPERATED USING R600a REFRIGERANT AND NANOADDITIVE COMPRESSOR OIL.

A Review on Performance of Vapour Compression Refrigeration System Using Nano Additive Refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Exergy and sustainability investigation of waste heat recovery vapor compression refrigeration system with silver Nano fluid

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Department of MCE, Islamic University of Technology 2. Abstract

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

International Journal of Informative & Futuristic Research ISSN (Online):

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

PERFORMANCE STUDIES ON A VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANO-LUBRICANT

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Waghmare Tushar Ramrao, D.S.Nakate

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Chapter 2. Alternatives to HCFCs and their Characteristics

ISSN: [Farooque* et al., 6(5): May, 2017] Impact Factor: 4.116

Performance investigation of Air-conditioning system using ejector as expansion device

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Design of LPG Refrigeration System

Transcription:

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM 1 RONANKI SURESH, 2 Dr. K. KALYANI RADHA 1 M.Tech, Mechanical Engineering, JNTUA College of Engineering Ananthapuramu, A.P, India 2 Asst.Professor, Mechanical Engineering, JNTUA College of Engineering Ananthapuramu, A.P, India Abstract: In modern days, refrigeration systems are important for industrial and domestic applications. Domestic refrigerators mostly work on vapour compression refrigeration cycle. Performance of any VCR suffers from its poor heat transfer properties of refrigerants to surroundings. Many methods are implemented to transfer heat from condenser. Such as forced convection, fins, number of condenser coils etc. But they increase the cost as well as power consumption by sacrificing the performance of VCR system. Hence the Nano fluids may be a promising solution to the existing problems to increase heat transfer rates in compressor. 0.5% V of Al2O3Nano particles are mixed with POE oil and used as lubricant in compressor (Hermitically shield and Oil cooled) and R600a as refrigerant in 220L capacity refrigerator. Also a diffuser is attached at condenser inlet to convert kinetic energy to pressure energy so as to increase work done without compression. Experiments are conducted to analyse the performance. Key words- R600a, Al 2 O 3 Nano particles mixed with POE oil, Diffuser at condenser inlet. I INTRODUCTION In today s world refrigeration systems are important for both domestic and industrial applications. Most of household refrigerators work on vapour compression system. The leakage of refrigerants from refrigerators may cause several problems to environment like ozone depletion, global warming etc. In order to rectify these problems, environmental safety refrigerants like hydrocarbons, their blends etc. are to be used. R600a is one of the environmental safety refrigerants with zero ODP and GWP is less than 3. Performance of VCR system suffers from its poor heat transfer properties of refrigerant to surroundings. Because of the thermal fluid which is used in the systems have less heat transfer coefficients. Many methods are implemented to transfer heat from condenser, such as forced convection, fins, number of condenser coils etc. But there is a need of changing the design of the system as well as they increase the cost and power consumption by sacrificing the performance of VCR system. Hence the Nano fluids may be a promising solution to the existing problems to increase heat transfer rates in compressor and condenser. Nano fluids are directly charged into the system without changing its design. They create turbulence in the pipes due to which heat transfer rate increases. The nano particles (Al, Cu, Al 2 O 3 Al 2 O 3 etc.) mixed with base fluids (water, refrigerant, engine oil etc.) combined together to form a colloid called nanofluid. The nano particles are in the form of solid, so they have more heat transfer rate than the normal refrigerants. The normal refrigeration cycle has major problems like high compressor work requirement, vibrations in condenser (due to the high velocity of refrigerant after compression). Hence the diffuser may be a promising solution to the existing problem. Diffuser is used to convert the kinetic energy available at compressor outlet to the pressure energy, which leads to reduction in compressor work as well as reducing the vibrations occurred in the condenser. II LITERATURE REVIEW Binit Kumar Jha, et.al. [1] Conducted an experimental investigation to compare the COP of VCR system using various refrigerants like R134a and R600a under condition -5 0 C evaporator temperature. The results showed that the alternative refrigerant investigated in the analysis R600a has higher coefficient of performance. Refrigerant property parameter shows that R600a has minimum leakage, minimum global warming potential and low power consumption when compared with R134a. Adityaswaroop et al. [2] Developed a new cycle with Diffuser at compressor outlet in a VCR system using R134a as a refrigerant to enhance the performance of the cycle. The experiment shows that the kinetic energy obtained at compressor outlet was converted into pressure energy. And the temperature, pressure at the diffuser outlet was increased when compared with that at compressor outlet. Due to this the reduction in compressor work takes place and COP of the system was increased. The experiment shows that the time required for the freezing in evaporator was also quicker than that of normal cycle. Pawel et al. [3] Conducted studies on nanofluids and found that there is the significant increase in the thermal conductivity of nanofluid compared to the base fluid. They also found that addition of nanoparticles results in significant increase in the critical heat flux. Bi et al. [4] Conducted studies on a domestic refrigerator using nanorefrigerants. In their studies R134a was used the refrigerant, and a mixture of mineral oil TiO2 was used as the lubricant. They found that the refrigeration system with the nanorefrigerant worked normally and efficiently and the energy consumption reduces by 21.2%. When compared with R134a/POE oil system. R.K Adyanshee Pattanayak et al. [5] Conducted Performance Analysis of a Domestic Refrigerator using Al 2 O 3 Nanoparticles. Results obtained and showed that the coefficient of performance of the refrigerating system was improved by 12.14% for the mass fractions of 0.47% of Al2O3 nanoparticles. There was also reduction of compressor s suction and discharge pressures with addition of nanoparticles. Jwo et al. [6] Conducted studies on a refrigeration system replacing R-134a refrigerant and polyester lubricant with a hydrocarbon refrigerant and mineral lubricant. The mineral lubricant included added Al 2 O 3 nanoparticles to improve the lubrication and heat-transfer performance. The power consumption was reduced by about 2.4%, and the coefficient of performance was increased by 4.4% for R-134a and 0.1 wt. % Al2O3 nanoparticles. R.Reji et al. [7] Performed heat transfer enhancement of domestic refrigerator using R600a/mineral oil/nano- Al 2 O 3 as working fluid. It was founded that the freezing capacity was higher and the power consumption reduces by 11.5 % when POE oil was replaced by a mixture of mineral oil and Aluminium oxide nanoparticles. Thus using Aluminium oxide nano-particles in refrigeration system was feasible and the coefficient of performance of the refrigeration system also increases by 19.6 % when the conventional POE oil is replaced with nano-refrigerant. JETIR1710041 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 263

In the present study the refrigerant selected is R600a and the nanoparticle is aluminium oxide. Isobutene (R600a) is more widely adopted in domestic refrigerator because of its better environmental and energy performances. A new refrigerator test system was built up according to the requirement of this study. 0.5% V and 50nm-200nm size of Al 2 O 3 Nano particles mixed with POE oil used as lubricant and R600a is used as refrigerant in 220L capacity refrigerator. Also a diffuser is attached at condenser inlet to convert kinetic energy available at condenser inlet to pressure energy so as to increase work done without actual compression. The freeze capacity test was conducted to compare the performance of the refrigerator with and without nano refrigerant so as to provide the basic data for the application of the nanoparticles in the refrigeration system. III EXPERIMENTAL SETUP & METHODOLOGY The layout of the tested refrigeration cycle as shown in figure 1. The main components are R600a compressor, proposed diffuser, condenser, capillary tube expansion valve. The diffuser is placed after compressor as shown in figure 2. The diffuser has actually made with copper and having dimensions as shown in figure 5. The main objective of diffuser is to convert kinetic energy into pressure energy. In the proposed layout of the tested refrigeration system, the diffuser is placed in between compressor and condenser in order to reduce compressor work which enhances the vapour compression system efficiency. Further advantage of the diffuser is that it reduces the tube vibration associated with the operation of the condenser and increases the heat transfer rate through the condenser. Fig 1: experimental refrigerator Fig 2: Line Diagram for experimental refrigerator Fig 3: Diffuser Fig4: Diffuser connection in the proposed model Fig 5: Line Diagram of Diffuser A) Nano fluid preparation: A two-step method of nano-fluid preparation is used in this study. The first step involves in the drying, storage, and transportation of nanoparticles into a conical flask. Al 2 O 3 with an average size of 50nm-200nmand 0.5% wt. concentration by volume is used. In the second step the nanoparticles Al 2 O 3 are directly mixed in the base fluid POE oil and thoroughly stirred with a hot plate stirrer to become POE- Al 2 O 3 nano-lubricant, followed by ultrasonic homogenization for about 3-4 hours. Frequent use of ultra-sonication or stirring is required to reduce particle agglomeration. Sedimentation was conducted after the homogenization process in order to check the stability of the POE- Al 2 O 3 nano-lubricant. The preparation process is as shown in figure 6. Fig 6: Two step preparation process of nanofluids B) Experimental Procedure: After the evacuation, various leakage tests like nitrogen and bubble tests and water submersion methods are done to confirm no leakage in the system. Then 400ml of nano-fluid is inserted to the compressor through the service port and allowed to stabilize for 15-20 JETIR1710041 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 264

Compressor Work(Kw) October 2017, Volume 4, Issue 10 minutes. After that 60gm of R600a is charged into the system. The refrigerant flows through the diffuser by opening the valves as shown in figure 4.The temperature and pressure measured at the compressor inlet, diffuser inlet, condenser inlet, evaporative inlet, expansion inlet and outlet with the help of thermocouples and pressure gauges. The ranges of pressure gauges for evaporator inlet/outlet and compressor inlet are 0 to 1.75MPa and for condenser inlet/outlet and compressor outlet is 0 to 3.5MPa. IV RESULTS AND DISCUSSION A) Time Vs. Evaporator Temperature: 30 25 20 Evaporator temperature (0 C ) 15 10 5 0-5 0 10 20 30 40 50 R600a R600a+Diffuser R600a+POEoil+Al2O3 nano particles R600a+POEoil+Al2O3 nano particles+diffuser -10-15 Time (min) Fig 7: Time Vs. Evaporator Temperature The figure 7 shows that the variation of time with respect to the evaporator temperature. As the temperature of evaporator decreases the time required is increases for all the cases of experiment. The figure 7 shows that the change in evaporator temperature has decreased after 30minutes, because of the evaporator temperature is stabilized around -5 0 C. The time required for getting -7 o C is less in Al 2 O 3 +POE oil when compared with normal R600a cycle. The time taken for getting -6 o C in normal cycle of R600a is 45 20.The time taken for getting the same temperature with diffuser at condenser inlet to the normal cycle is 42 43. The time taken for getting the same evaporator temperature with Al 2 O 3 +POE oil to the normal cycle is 29 16. And the time taken for getting the same temperature (-7 o C) with Al 2 O 3 +POE oil along with diffuser at condenser inlet to the normal cycle of R600a is 27 13. Thus the time taken for getting the same evaporator temperature (- 7 o C) is less in the case of Al 2 O 3 +POE oil along with diffuser at condenser inlet cycle. B) Comparison of Compressor Work Required for Ton of Refrigeration: 1.2 1.1 1 0.9 0.8 0.7 1.141 1.056 1.035 0.954 R600a R600a+Diffuser R600a+Al2O3 Nano R600a+Al2O3 Nano Particles+POEoil Particles+POEoil+Diffuser Fig 8: Comparison of Compressor Work Required for Ton of Refrigeration The figure 8 shows that compressor work required for ton of refrigeration is less in the case of R600a with Al 2 O 3 +POE oil along with diffuser at condenser inlet when compared with R600a normal cycle. The Al 2 O 3 +POE oil increases the heat transfer rate in the compressor. Therefore the specific volume of compressed refrigerant decreases which leads to reduction in compressor work. And the diffuser facilitates static pressure recovery of the refrigerant entering the condenser, thereby increasing the pressure of the refrigerant leaving the diffuser compared to the pressure of refrigerant entering the diffuser, which leads to reduction in compressor work. The compressor work saved due to diffuser at condenser inlet to the normal cycle is7.45%. The compressor work saved due to Al 2 O 3 +POE oil cycle when compared with normal cycle is 9.30%. The compressor work saved due to Al2O3+POE oil along with diffuser at condenser inlet when compared to the normal cycle is 16.34%. JETIR1710041 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 265

COP Refrigeration Effect(kJ/Kg) October 2017, Volume 4, Issue 10 C) Comparison of Refrigeration Effect throughout the Experiment: 335 330 325 320 315 310 305 300 313 315 R600a R600a+Diffuser R600a+Al2O3 Nano Particles+POE oil 328 330 Fig 9: Comparison of Refrigeration Effect throughout the Experiment R600a+Al2O3 Nano Particles+POE oil+diffuser The figure 9 shows that the refrigeration effect for R-600a using Al 2 O 3 +POE oil along with diffuser at condenser inlet is more when compared with normal cycle. The Al 2 O 3 +POE oil increases the heat transfer rate at all the components. The diffuser also increases the heat transfer rate through the condenser due to the temperature difference is more at condenser. Due to this the refrigerant temperature at condenser outlet is just before the saturated liquid line as shown. That means sub cooling is obtained at the exit of the condenser. Therefore the refrigeration effect increases in the case of R600a using Al 2 O 3 +POE oil along with diffuser at condenser inlet when compared with normal cycle. D) Comparison of COP throughout the Experiment: 3.8 3.6 3.4 3.2 3 2.8 2.6 2.4 2.2 2 3.069 R600a Normal cycle 3.316 3.38 R600a with DIFFUSER R600A+Al2O3 nano particles+poeoil 3.667 R600a+Al2O3 nano particles+poe oil+ Diffuser COP Fig 10: Comparison of Coefficient of Performance The figure 10 shows that the coefficient of performance for R-600a using Al 2 O 3 +POE oil along with diffuser at condenser inlet is higher than the R600a with normal cycle. Due to the reduction in compressor work, increase in refrigeration effect the coefficient of performance is more with Al 2 O 3 +POE oil along with diffuser at condenser inlet. The percentage increase of COP with diffuser at condenser inlet to the normal cycle is 8.04%. The percentage increase of COP for Al 2 O 3 +POE oil cycle when compared with normal cycle is 10.13%. The percentage increase of COP for Al 2 O 3 +POE oil along with diffuser at condenser inlet when compared to the normal cycle is 19.48%. The above all effects are due to the reduction in compressor work by diffuser, increase in refrigeration effect by Al 2 O 3 +POE oil. E) Performance comparison of R600a Normal cycle to R600a Using Al 2 O 3 +POE oil along with diffuser at condenser inlet: Fig 11: Performance comparison of R600a Normal cycle to R600a Using Al 2 O 3 +POE oil along with diffuser JETIR1710041 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 266

1-2-3-4 R600a with Normal Cycle a-b-c-d-e R600a using Al 2 O 3 +POE oil along with diffuser at condenser inlet. Due the better heat transfer rate property of the Al 2 O 3 +POE oil the temperature after compression (T b 0 C) is less when compared with normal cycle temperature (T 2 0 C). Therefore the specific volume of compressed refrigerant decreases which leads to reduction in compressor work when compared with the normal cycle. The compressor work in the system is (h b- h a ) kj/kg. when diffuser valves are opened in the same system the diffuser work obtained is (h c -h b ) kj/kg. Then the reduction of compressor work due to diffuser is [(h b- h a ) - (h c -h b )] kj/kg. The diffuser increases the heat transfer rate through the condenser as well as the nano fluid also increases heat transfer rate through the condenser. Because of these reasons the temperature at condenser outlet also decreases and sub cooling is obtained at condenser outlet, which leads to increase of refrigeration effect. Therefore the COP of the Al 2 O 3 +POE oil along with diffuser at condenser outlet cycle is increases when compared with normal cycle of the R600a refrigeration. The coefficient of performance of R600a & Al 2 O 3 +POE oil along with diffuser cycle = (h a -h e ) / [(h b- h a ) - (h c -h b )] V CONCLUSIONS An experimental analysis is performed on Vapour Compression Refrigeration System with R600a used as refrigerant and the system is run for four cases. Those are normal cycle, diffuser at condenser inlet cycle, Al 2 O 3 nano particles+poe oil cycle and Al 2 O 3 nano particles+poe oil along with diffuser at condenser inlet cycle. In these four cases the performance parameters like Refrigeration effect, Compressor work and COP are investigated and evaluated. In the case of R600a with Al 2 O 3 nano particles+poe oil along with diffuser at condenser inlet cycle, the refrigeration effect is increased by 5.04%, the compressor work is decreased by 16.34% and the overall coefficient of performance is increased by 19.48% when compared with normal cycle. Hence it can be concluded that the cycle with Al 2 O 3 nano particles+poe oil along with diffuser at condenser inlet has better performance and take less time for the same freezing capacity when compared with normal cycle. APPENDEX a) Properties of POE oil: Viscosity 32 m 2 /sec Flash point 258 0 C Pour point -46 0 C Miscibility temperature -42.2 0 C Density 0.977 Kg/L Acid value <0.05 b) Properties of Al 2 O 3 Nano Particles: Property Description Melting Point 2072 0 C Boiling Point 2977 0 C Colour Ivory/White Density 0.26*10-3 Kg/m 3 Specific Heat 880 J/KgK Thermal Conductivity 30 W/Mk Molecular Mass 0.10196 Kg/mol Specific Surface Area 500 50000 m 2 /Kg Appearance White Powder ph 7-9 REFERENCES [1] Binit Kumar Jha, Performance of Refrigerator Using R-600a as Refrigerant, proceedings of 2015 2 nd international conference on recent innovations in science, engineering and management. JNU convention center, New Delhi 2015. [2] Adityaswaroop, To Improve COP of a Refrigerator Using Diffuser, proceedings of 2017 4 th International conference latest trends in engineering, science, humanities and management.indian federation of united nations association, Qutab institutional area, New Delhi 2017. [3] Pawel K. P., Jeffrey A.E. and David G.C., 2005. Nanofluids for thermal transport. Materials Today, pp. 36-44. [4] Bi S., Shi L. and Zhang L., 2007. Performance study of a domestic refrigerator using R134a/mineral oil/nano-tio2 as working fluid. ICR07-B2-346. [5] R.K Adyanshee Pattanayak, Nilamani Sahoo, Prasheet Mishra, Performance Analysis of a Domestic Refrigerator using Al2O3 Nanoparticles, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE)2015,Volume12, Issue 4, PP 12-16 [6] Jwo 2009. Effect of nano lubricant on the performance of Hydrocarbon refrigerant system. J. Vac. Sci. Techno. B, Vol.27, No. 3, pp. 1473-1477. [7] R.Reji K. Sridhar, M.Narasimha Heat transfer enhancement in domestic refrigerator using R600a/mineral oil/nano-al2o3 as working fluid, International Journal of Computational Engineering Research 2013, Vol.3, Issue:04, Pp. 43-50. JETIR1710041 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 267