MODEL E

Similar documents
MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

SUPPLEMENTARY INSTRUCTIONS

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

SUMP PUMP INSTALLATION INSTRUCTIONS MODEL

Fan Air AIR EXTRACTOR & DEHUMIDIFIER SYSTEM

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps

FEATURES. Other Fed-Flush Arrangements

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

Welcome! Today s topic: Small Home Repairs. November 14, 2015

MULTISAN Fully automatic sewage and waste water pump

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE SEWAGE PUMP. Automatic and manual models. Single phase power only 115 or 230 volt.

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

MG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential and Pressure Sewer Applications.

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

LC Series - Light Commercial Pump Station Installation and Operation Manual

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

NOTICE TO INSTALLER: Instructions must remain with installation. 95 North Oak Street Kendallville, IN

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

Installation and Operating Instructions

Food Waste Disposer Instruction Manual

Installation instructions for the T 9820 Gas Dryer

e Bath Fan with Light User s Guide

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Installation Instructions

STOP. For missing, damaged parts or technical help, Call before returning product

Installation Instructions

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

T-Series Air Conditioner T15 Model

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

Installation Guide BUBBLEMASSAGE. English page T01-A

SUBMERSIBLE DIRTY WATER PUMP

1.6 GALLON ONE PIECE TOILET

Lubi Submersible Condensate Removal Pumps

TYPE POS Oil Shield Sump Pump

Gen II Entree Bath - All Models

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T53 Model

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

V80-H Multistage Pump Instruction Manual

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

Installation. Please keep this manual for future reference.

FOOD WASTE DISPOSER OWNER S GUIDE

IH091: Home Wastewater Disposal System Installation Instructions & Warranty Information

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

STERI-VAC CENTRAL SUCTION SYSTEM

Installation Instructions

Landis Fume Buster 3, 4 & 5 Foot

Installation Instructions

e Bath Fan with Light User s Guide

Dishwasher Installation Manual

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Choosing the Right Pump

Sump Pumps Instruction Manual & Safety Warnings

SUBMERSIBLE WATER PUMPS

Installation Instructions

INTERMEDIATE GUIDE BRACKET

e Bath Fan with Light User s Guide

INSTALLATION OPERATION MAINTENANCE LANCASTER MODELS X99M33 & X99M50

INSTANT HOT WATER DISPENSER

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

RIVERSOFT Water Softener System

8707T Includes seat. 8745T Includes Bowl

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Dishwasher Installation Instructions DW 24XT/DW 24XV

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

Installation Electric Dryers Instructions 01

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Installation Instructions

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

GALAXY FLOOR MACHINE

KD-27A SERIES DISHWASHERS

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Installation Instructions Built-In Dishwasher

Installation Instructions

Installation Instructions

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Top Control Dishwasher

Installation Instructions

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Transcription:

www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. INITIAL START UP PROCEDURES: 1. Inspect the pump and the sewage tank for any obvious condition that may necessitates cleaning, correction, adjustement or repair. 2. Assure that the pump is secure and vertical for proper operation. 3. Assure that there is adequate clearance from any combustible materials or structure. Stored materials must be kept away from the pump. Shelves or cabinet structures must not be in close proximity over the pump. 4. Assure that the motor is securely plugged into a proper GFCI electrical outlet. 5. Test the GFCI outlet by pressing its test switch. This should prove that the outlet is energized and will trip off to protect against a ground fault. Be sure to reset the GFCI by pressing its reset switch. (Repeat this step monthly) 6. Lift the float to assure that the pump will start when required. (Step 7 below will test submersible pumps with enclosed floats). 7. Pour pails of water in the sewage tank to turn the pump on. Assure that any check valve present will permit the sewage to flow. 8. Observe that the plumbing can pump the sewage safely out of the residence. (Repeat this step monthly) INSTALLATION INSTRUCTIONS MODEL 400500 400510 400500E SEWAGE PUMPS Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. 2013 BUR-CAM Printed in Canada 400391

SAFETY INSTRUCTIONS: Before installation and operation, follow these procedures: A B C D Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed with your safety in mind. Be sure you comply with them. A separate circuit must be lead from the home electrical distribution panel properly protected with a fuse or a circuit breaker. We also required that a ground fault circuit be used as well as a GFCI receptacle. Consult a licensed electrician for all wiring. The ground terminal on the three prong plugs should never be removed. They are supplied and designed for your protection. Never make adjustments to any electrical appliance or product with the power connected. Do not only unscrew the fuse or trip the breaker, remove the power plug from the receptacle. Electrical Connection For pumping systems using more than one pump, each pump needs to be connected to a separate dedicated circuit protected by a fuse or breaker. This way, the power supply of one pump will not stop operating if the fuse of one of the pumps burns or if the breaker of one of the pumps trips. Material required for sewage pump application 2 Desired length of ABS/DWV 2 pipe, to link up from pump discharge to waste or drain existing pipe. Required quantities of 2 ABS/DWV elbow(s) and/or other fitting(s) to run the discharge line. 1 only 2 ABS/DWV male adaptor to 2 slip, to connect the discharge pipe to the pump. Desired length of ABS/DWV 3 pipe and required quantities of 3 ABS/DWV elbow(s) and/or other fitting(s) to run the vent line. 1 only 2 union check valve # 450457. 1 only 18 X 30 minimum size sewage basin like # 400420. Teflon tape and ABS cement. NOTICE This unit is not designed for applications involving salt water or brine. Use with salt water or brine will void warranty. TOOLS Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench, adjustable wrench, 1/4 drill bit and drill. Ensure that you have a gas tight cover for your sewage basin and 3 ABS/DWV vent piping.

APPLICATIONS Designed for a permanent installation for homes and cottages application. To pumping where the total head requirements do not exceed 15 feet, including pipe friction losses. CAPACITY: 5 4500 USGPH 17000 LPH 10 3120 USGPH 11800 LPH 15 720 USGPH 2700 LPH FRICTION LOSS IN PIPE NOT INCLUDED FEATURES Vortex designed impeller made from noryl, will not corrode. Rugged cast iron pump body. Stainless steel mechanical rotary type motor seal. 2 NPT pump discharge. Thermal and overload protection. 1/2HP, 115VAC, 60Hz, 9.2A, (18A when start). Mechanical type float switch, 15A. Vertical switch for 400510 and 400500E, 10A. IMPORTANTE NOTICE The following are minimum requirements in order to protect your residence from flooding. It is a small investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply with the following requirements will also void your warranty: - Two (2) pumps have to be installed in the sewage pit. The first pump as a primary pump and the second pump as the backup unit. - An Alarm system model 450454 has to be installed to advise you of any malfunctions. Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be adhered to. INSTALLATION STEPS See typical installation diagram in page 4 STEP 1 STEP 2 STEP 3 STEP 4 We recommend that you install your pump and basin in a clean location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Assuming that you have a sump pit located in your basement floor... Your sump pit should be constructed from concrete, brick, tile or more recently a sump basin made from plastic and/or fiberglass. The minimum size of your sump pit must be 18 in diameter and no less than 25 deep. When pit is ready, proceed to next step. Friction losses in the discharge pipe must be taken into consideration when many elbows and fittings are installed in the discharge line. Each elbows and fittings must be considered as 1 feet of head. Never run the pump dry. Damage to the seal may occur. The run of the pipe from the check valve to the existing waste or drain line must never be slooping downward except when connecting to same. For a new installation, install your sewage basin in the excavation you have provided in the basement floor of your home. Connect the necessary piping from your shower trap, toilet, etc., to the inlet of your sewage basin, with the proper pipe and fittings (see diagram). Cut a length of 40 to 42 of 2 ABS/DWV pipe. Cement the 2 ABS/DWV male adaptor to 2 slip to one end of this pipe. With your drill, make a 1/2 hole in the adaptor previously glued. This hole will prevent any air locking wich might occur. 3

STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 Screw the pipe with the male adaptor into the 2 discharge opening in the pump. Lower pump with piping attached into the sewage basin. Make sure that the pump is as close as possible to the centre of the basin. Adjusting the pump in centre of basin will keep mechanical float switch from rubbing on side of basin. When you are pumping raw sewage, you must have a gas tight cover on the basin and a vent pipe from basin, connecting to home s vent system (see diagram). Feed the 2 riser pipe from pump s discharge, through the 2 opening in the cover. Secure a 3 vent pipe to the cover and bring the switch and pump motor power cables through the opening in the cover provided. Install a 2 check valve (model 450457) union type to the 2 discharge riser pipe coming out of the cover, to a lenght of 2 ABS/DWV pipe, and run the discharge line as short as possible to the home s waste sewer line. Secured the check valve with the provided clamps. Be sure that the arrow on valve are pointing away from pump. Connect the 3 prong plug of the switch in a receptacle. Insert the motor 3 prong plug into female receptacle on exposed piggy-back of switch plug. The mechanical switch provided for automatic operation is preset to pump. No adjustments are necessary. Fill the sewage basin with water to test the operation of the submersible sewage pump and switch operation. Pump should start pumping when the water level reaches 12 to 15 above the bottom of the basin and above the pump. Allow the pump to go several on-off cycles to assure satisfactory operation. Secure the gas tight cover and the plug for electrical cords with the gaskets and screws provided with the cover. Make vent connection to home s vent system. Note that a vertical switch is installed on model 400510 and 400500E. The 400510 switch setting is for a regular sewage basin while model 400500E has a special setting for our Easy Flush System only. SEWAGE SYSTEM TYPICAL PIPING Home s vent system Raw sewage discharge line Pump s discharge line Basin vent line From From From bath or shower Toilet Sink 4 Sewage basin inlet

STEP 7 Install check valve STEP 6 Set gaz tight cover, discharge and vent pipes SEWAGE PUMP APPLICATION STEP 8 Connect to receptacle STEP 10 Secure cover and make vent connection STEP 5 Install discharge pipe and lower pump in centre of basin STEP 2 Install sewage basin STEP 4 Drill a 1/4 hole STEP 9 Fill with water and test operation 400500 / 400510 / 400500E STEP 3 Cement 2 adaptor to pipe 7 6 27 26 25 24 23 8 REPAIR PARTS # PART DESCRIPTION 1 450426 Pump body 2 450432 Gasket 3 450428 Impeller bolt 4 450430 Impeller washer 5 450427A Impeller 6 450425 Cast iron top flange 7 450429 Pump cover screws (3) 8 450210 Snap ring (2) 9 450211 Washers (2) 10 450200 Mechanical seal 11 450215 Stator 12 450216 Lip seal 13 506032 Upper bearing 14 450218 Rotor and shaft 15 350340 Lower bearing 16 450220 Washer # PART DESCRIPTION 17 450233 Motor shaft key 18 450221 Motor flange 19 450222 Capacitor 20 450209 Large O ring 21 450201 Upper casing 22 450208 Small O ring 23 450202 Handle 24 450227 Handle screw 25 450228 Power cable 26 450229 Plug 27 450230 Long bolt 28A 450453 Mechanical switch 28B 450447B Vertical switch 28C 450446 Vertical switch 29 400389T Assembly motor 9 5 4 3 2 1 28A 28B 28C 20 19 16 17 13 12 29 8 22 21 18 15 14 11 10 9 5 400500 400500E 400510

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Disconnected plug Corroded plug Float stuck Defective switch Defective motor Turn switch to on position Reset Re-install Clean Check movement Motor runs but no water is delivered. Improper voltage Pump may be airlocked Pump discharge head too high Clogged inlet/impeller Check voltage Check drilled hole in discharge pipe Wrong pump selection (over 15 ) Clean Pump does not deliver to full capacity. Improper voltage Pump may be airlocked Pump discharge head too high Clogged inlet/impeller Check voltage Check drilled hole in discharge pipe Wrong pump selection (over 15 ) Clean Pump does not shut off. Defective switch Missing check valve Clogged check valve in open position Float obstruction Install valve Clean debris Check for movement 6 TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation.