DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

Similar documents
Dehumidifier- DSR Instruction manual version 01

DSR-12/20 DSRT-20 DEHUMIDIFIER. GB General information - Exploded view - Parts list

DSR-12/20 DSRT-20 GENERAL INFORMATION EXPLODED VIEWS - PARTS LISTS ENGLISH

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

CABINET PARTS For Model: JS48NXFXDW03 (Base Model)

Air Conditioner Service Manual

51AKB / 51 AKC OWNER S MANUAL

MeacoDry ABC Range Dehumidifiers

Meaco 10L small home dehumidifier Instructional Manual

CABINET PARTS For Model: KSSC42QVS03 (Stainless Steel)

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

Trento. Modular Suite. For use with the Skope Electric Outset Range. Instructions for Use and Installation

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Xpelair Simply Silent TM Contour Fan

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Xpelair Simply Silent DX150

CDP 40 SWIMMING POOL DEHUMIDIFIER

Mobile Air Conditioner Instruction Manual Model TC-N9KM

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

EH0554 Indoor Climate Control

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

30KW ELECTRIC FAN HEATER

Desiccant Dehumidifier

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Cabinet Refrigerators/Freezers Instruction manual

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

Meaco Platinum Range Instruction Manual

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

12,000 BTU Evaporative Portable Air Conditioner

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

Quest Dry 105, 155, and 205 Dual

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

EH0533 Indoor Climate Control

Simply Silent Contour 4 (100mm) Axial Extraction Fan

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

4. Disassembly and Reassembly

OVEN PARTS For Models:YKEMC308KM02 (STAINLESS STEEL)

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

ST E /ST E / ST E / ST E ST E / ST E / ST E

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

USER MANUAL TPS-M5/M55/M555

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

OVEN PARTS For Models: KEMC308KBL04, KEMC308KWH04, KEMC308KBT04, KEMC308KSS04 (Black) (White) (Biscuit) (Stainless Steel)


CU0415, CU0715 and CU0920 Service Parts

DEVIL CERAMIC SPACE HEATERS

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

MeacoCool MC Series Portable Air Conditioner

Service Manual & Installation Manual

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

2.8KW ELECTRIC FAN HEATER

MINI DEHUMIDIFIER. SD-350TI With UV Light SD-350 INSTRUCTION MANUAL

Xpelair Simply Silent DX100B

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

OVEN PARTS For Models:YKEMC308KM0 (STAINLESS STEEL)

PGD930DES USER MANUAL. VER

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CABINET PARTS For Model: KSF26C6XYY00 (Monochromatic Stainless)

VCBF136RSS3 : CABINET [1/9]

SH3020 USER INSTRUCTIONS

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

AQUAIR S SERIES. of Water to Air Space Heaters INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONSS. Aquair S-10 Aquair S-16 Aquair S-20

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

OVEN PARTS For Models:YKEHV309PS01, YKEHV309PM01 (Stainless Steel) (Meteorite)

FLOOR CONSOLE / UNDER CEILING DUAL type

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

60cm Chimney Extractor

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

Owher s. 9-syj ROOM AIR CONDITIONERS. Note to You. Instructions. Parts and Features. Operating Your Air Conditioner. Personalizing the Front Panel

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

Dual-Hose Portable Air Conditioner User Manual

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

PORTABLE AIR CONDITIONER MODEL NO: AC7000

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

Progress plus Instruction manual

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

PANEL RADIATOR. USER MANUAL HSDOnline.co.uk 2KW OIL FILLED POH04

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

Transcription:

DEHUMIDIFIERS GENERAL INFORMATION EXPLODED VIEWS PARTS LISTS DSR SERIES DSR-20 DSR-12 ENGLISH ATTENTION! There is a time delay on all units fitted with DFC 1 Controller. When starting or re starting the unit, it could take up to 3 minutes for the fan and compressor to start running. 0912R1

GENERAL INFORMATION SAFETY For safety reasons, read this information carefully before operating. Persons who are not familiar with this type of product must not use it. We strongly recommend keeping this information in a safe place for future reference. This appliance must be earthed. The unit is designated for indoor operation. Refer to the rating plate for voltage and power input. The installation must be in accordance with regulations of the country where the installation is performed. The minimum distance between air inlet(s) and/ or air outlet(s) and any object must be 40 cm. The unit is safe. It has been approved by many safety institutions around the world. However, as with other electrical appliances, use it with care. Keep out of reach of children. Do not clean the unit by spraying it or immersing it in water. Do not insert any object into an opening of the unit. Disconnect from the mains before cleaning the unit or any of its components. Never connect to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licenced electrician. Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform to the regulations regarding electrical installations. DSR DEHUMIDIFIERS You can t control humidity and haze outdoors. But in an indoor swimming pool and other humid interior spaces where hot stuffy air, steamy windows and walls are frequent phenomena, you can. That s why you need a DSR dehumidifier. Our dehumidifiers clear the air in damp interior spaces. Condensation is removed from windows, walls and ceilings. Vaporous stuffy air is drawn off, clean air is pumped back in. You simply set the dial and the air humidity remains at the required level. Water evaporating from a swimming pool, bathroom, archive, store or from wet objects and surfaces increases the humidity of the air and creates the hazy and stuffy air often found in the hall. At the same time water condenses on the cooler parts in the hall: windows, walls, ceilings, etc. Water condensation is not only an aesthetic defect, it can, in the long run, cause structural damage. There are two methods for drying the air in humid spaces: - by ventilation, - by heat pumps. Our dehumidifier is designed as a heat pump and has, through energy saving, a considerable advantage over a ventilation system. 2

GENERAL INFORMATION HOW THE DSR DEHUMIDIFIER WORKS The fan (1) sucks the humid air through the evaporator. There the air is cooled and the moisture in the air condenses into water. This water is collected in the tray and drained away through the sump and piping. The compressor (5) pumps the heat, which has been extracted from the air, into the condenser (6). There, this heat is once again released, and absorbed by the dry air. The ready wired control box monitors and controls the operation. ELECTRICAL WIRING The unit can be supplied with a cord and an earthed plug. If it ever becomes necessary to replace this plug, be sure to use an earthed plug suitable for the power supply in your area and conform to your national safety standard. The wires of the cable are coloured in accordance with the standard electrical code. Blue Neutral Brown Live Green/Yellow Earth The blue (neutral) wire should be connected to the terminal in the plug marked N or coloured black. The brown (live) wire should be connected to the terminal in the plug marked L or coloured red. The green/yellow (earth) wire should be connected to the terminal in the plug marked E or coloured green or marked with this symbol: The unit must be connected to the power supply with the appropriate leads. The cord should pass through holes with rubber grommets. Properly fused disconnect switches must be installed between the unit and the power source. The unit must be wired with an isolation (mains) switch accessible from outside the wet area in which the unit is installed, to comply with IEE regulations. MAINTENANCE The appliance is actually maintenance free, except in cases of soiling. In this case the filter has to be cleaned. Models DSR-12 and DSR-20 see page 4 Contains Flouronated Greenhouse gasses covered by the Kyoto Protocol R410A Charge: DSR-12= 1.25kg DSR20= 1.5kg 3

GENERAL INFORMATION DSR INDOOR SWIMMING POOL ROOM DEHUMIDIFIERS Our swimming pool dehumidifier is a ready to install, transportable, appliance. It can be mounted on a wall or ceiling console in the pool room or even over a shower booth. It may be mounted in adjoining rooms and connected by ducts to the pool room. We have not adapted normal room air-conditioners for use in indoor swimming pools, we have developed pool dehumidifiers particularly for this purpose. The compressor therefore matches exactly the capacity of the evaporator, thus achieving the optimal balance between efficiency and power consumption. The pool dehumidifier is controlled by a humidistat which operates at a low (=safety) voltage of 24V. The relative humidity in an indoor swimming pool can be adjusted between 50-80% when an external hygrostat is used. INSTALLING THE DSR The minimum distance between inlet(s) and/or outlet(s) and any object must be 40 cm. Installation of the dehumidifier is easy, as the unit is built on a base and slides out of the housing. The individual parts are logically arranged and can be inspected. First, remove the screws of the frame with louvers. Remove the screws on the base. Now the unit can be taken out the housing. Prepare a suitable console and mount it on the wall. Mount the housing on the console and attach it by fastening its base with screws to the legs (which should preferably be lagged with a vibration dampening material). Insert the unit into the housing, fasten the housing to the base and attach the louvered frame in front of the housing. Attach a 3/4 I.D. flexible pipe to the drain nipple located at the back of the dehumidifier. MAINTENANCE OUTLET INLET The appliance is actually maintenance free, except in cases of soiling. In this case the filter has to be cleaned. To remove the filter, slide open the 2 latches that hold the filter grille, located at the back of the unit. Swing the grille towards you and upwards to access the filter. Remove the filter. Use a vacuum cleaner to remove dust and debris. The filter can then be flushed clean with a stream of water. Let any trapped water drip off the filter fabric and allow to dry. Replace the dried filter in reverse order. OPERATING RANGE 1/2 BSP Max. working temperature 35 C Min. working temperature 5 C Relative humidity 40-100% 4

MODEL DSR-12 MOISTURE REMOVAL / DSR-12 DSR-12 - MOISTURE REMOVAL AT DIFFERENT ROOM TEMP. EN R.H.% (liter water/24h) RELATIVE HUMIDITY % ROOM TEMP. C 85 80 75 70 65 60 55 50 15 41 37 34 31 28 25 23 17 20 57 52 48 43 38 34 30 27 24 73 66 60 55 49 43 39 34 25 77 70 63 58 51 46 41 36 26 80 73 67 60 54 48 43 38 27 84 77 70 63 56 50 45 40 28 88 80 73 66 59 52 47 42 29 92 84 76 69 62 55 49 43 30 96 87 79 72 64 57 51 45 32 100 91 82 75 67 59 53 47 35 104 94 86 78 69 62 55 49 WIRING DIAGRAM DSR-12 JACK PLUG SMALL SWITCH EVAPORATOR TEMP SENSOR COMPRESSOR CONDENSER TEMP SENSOR PCB FAN SWITCH FAN TERMINAL BLOCK CAPACITOR EARTH POST MAINS LEAD SYMBOL BL BK G/Y R WT COLOUR BLUE BLACK GREEN/ YELLOW RED WHITE 5

MODEL DSR-12 EXPLODED VIEW DSR 12 No. PART No DESCRIPTION TYPE QTY 1 DH02-A001 BASE PANEL ASSY ASSEMBLY 1 2 DH02-A003 DRAIN TRAY ASSY ASSEMBLY 1 3 DH02-C017 FAN HOUSING MOUNTING BRACKET PART 1 4 DH02-A004 FAN PART 1 5 DH02-C012 INNER PANEL RH PART 1 6 DH02-C011 INNER PANEL LH PART 1 7 DH02-P021 COMPRESSOR PART 1 8 DH02-P004 CONDENSER COIL PART 1 9 DH02-C006 EVAP MOUNT BRACKET LEFT PART 1 10 DH02-C049 EVAP MOUNT BRACKET RIGHT PART 1 11 DH02-P003 EVAPORATOR COIL PART 1 12 DH02-C008 EVAP TOP COVER PART 1 13 DH02-C013 FAN HOUSING PART 1 14 DH02-A010 PCB ASSEMBLY 1 15 DH02-A009 COVER ASSY ASSEMBLY 1 16 DH02-P029 COMPRESSOR CAPACITOR PART 1 17 DHO2-P021 FILTER MATERIAL PART 1 18 DH01-P003 ROCKER SWITCH ASSEMBLY 1 19 DH02-C047 COIL BRACE RIGHT PART 1 20 DH02-C048 COIL BRACE LEFT PART 1 21 DH02-PO33 JACK SOCKET PART 1 22 DH02-P032 ROCKER SWITCH SMALL ASSEMBLY 1 No. PART No DESCRIPTION TYPE QTY 1 DH02-C030 COVER PART 1 2 DH02-C021 COVER OUTLET END PANEL PART 1 3 DH02-A007 REAR PANEL ASSY ASSEMBLY 1 4 DH02-C026 FILTER DOOR PART 1 5 DH02-P027 HANDLE PART 4 6 DH01-P004 LATCH PART 2 7 DH02-P021 FILTER MATERIAL PART 1 6

MODEL DSR-20 MOISTURE REMOVAL / DSR-20 DSR-12 - MOISTURE REMOVAL AT DIFFERENT ROOM TEMP. EN R.H.% (liter water/24h) RELATIVE HUMIDITY % ROOM TEMP. C 85 80 75 70 65 60 55 50 15 69 62 57 52 46 41 23 17 20 96 87 79 72 64 57 51 45 24 121 110 100 91 81 72 64 57 25 128 116 106 96 85 76 68 60 26 134 122 111 101 90 80 71 63 27 141 128 116 106 94 84 74 66 28 147 134 121 110 98 87 78 69 29 153 139 127 115 103 91 81 72 30 160 145 132 120 107 95 85 75 32 166 151 137 125 111 99 88 78 35 173 157 143 130 116 103 92 82 WIRING DIAGRAM DSR-20 JACK PLUG SMALL SWITCH EVAPORATOR CONDENSER TEMP SENSOR TEMP SENSOR FAN PCB SWITCH COMPRESSOR FAN TERMINAL BLOCK CAPACITOR SYMBOL COLOUR BL BLUE EARTH POST MAINS LEAD BK G/Y R BLACK GREEN/ YELLOW RED WT WHITE 7

MODEL DSR-20 EXPLODED VIEW DSR-20 No. PART No DESCRIPTION TYPE QTY 1 DH02-A001 BASE PANEL ASSY ASSEMBLY 1 2 DH02-A003 DRAIN TRAY ASSY ASSEMBLY 1 3 DH02-C017 FAN HOUSING MOUNTING BRACKET PART 1 4 DH02-A004 FAN PART 1 5 DH02-C012 INNER PANEL RH PART 1 6 DH02-C011 INNER PANEL LH PART 1 7 DH02-P021 COMPRESSOR PART 1 8 DH02-P001 CONDENSER COIL PART 1 9 DH02-C006 EVAP MOUNT BRACKET LEFT PART 1 10 DH02-C007 EVAP MOUNT BRACKET RIGHT PART 1 11 DH02-P002 EVAPORATOR COIL PART 1 12 DH02-C008 EVAP TOP COVER PART 1 13 DH02-C013 FAN HOUSING PART 1 14 DH02-A010 PCB ASSEMBLY 1 15 DH02-A009 COVER ASSY ASSEMBLY 1 16 DH02-P013 COMPRESSOR CAPACITOR PART 1 17 DHO2-P021 FILTER MATERIAL PART 1 18 DH01-P003 ROCKER SWITCH ASSEMBLY 1 19 DH02-C047 COIL BRACE RIGHT PART 1 20 DH02-C048 COIL BRACE LEFT PART 1 21 DH02-PO33 JACK SOCKET PART 1 22 DH02-P032 ROCKER SWITCH SMALL ASSEMBLY 1 No. PART No DESCRIPTION TYPE QTY 1 DH02-C030 COVER PART 1 2 DH02-C021 COVER OUTLET END PANEL PART 1 3 DH02-A007 REAR PANEL ASSY ASSEMBLY 1 4 DH02-C026 FILTER DOOR PART 1 5 DH02-P027 HANDLE PART 4 6 DH01-P004 LATCH PART 2 7 DH02-P021 FILTER MATERIAL PART 1 8

CONTACT 9