Air-Cooled Scroll Compressor Water Chillers

Similar documents
Air-Cooled Scroll Compressor Water Chillers

Air-Cooled Scroll Condensing Units

Air-Cooled Scroll Condensing Units

Air-Cooled Scroll Compressor Water Chillers

Packaged Air-Cooled Water Chiller

Air-Cooled Scroll Condensing Units

Air-Cooled Global Chiller

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

MAC N-407 Air-Cooled Chiller

GeneSys Air-Cooled Screw Compressor Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

MACH N-407 Heat Pump Air-Cooled Chiller

Water-Cooled Scroll Compressor Chillers

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Scroll Compressor Chillers

Call us today! (800)

Water-Cooled Scroll Compressor Chillers

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller

Water-Cooled Scroll Compressor Chillers

Call us today! (800)

Air-Cooled Screw Compressor Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Air-Cooled Scroll Chillers w/ Remote Evaporators AGZ 026BM through 130BM

PACKAGED AIR COOLED Product Data Catalog

Call us today! (800)

MAC-120HE-03 Air-Cooled Chiller

.2 Section Waste Management and Disposal.

Condensing Unit Installation and Operating Instructions

MODELS W1LC220, 260 AND 320 STYLE B

Water-Cooled Scroll Compressor Chillers

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Installation Instructions

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Commercial High-Efficiency Condensing Units

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Air-Cooled Scroll Compressor Chiller

Installation, Operation, and Maintenance Information

Water-Cooled Scroll Compressor Chillers

Commercial High-Efficiency Condensing Units

SECTION ROTARY-SCREW WATER CHILLERS

PDF Created with deskpdf PDF Writer - Trial ::

PACKAGE AIR CONDITIONER

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Air-Cooled Condensing Units. Direct Expansion Evaporators. Product Manual. ALP 027C through ALP 041C, 25 to 40 Tons, 88 to 140 kw 50 and 60 Hertz

Condensing Unit Installation and Operating Instructions

User s Information and Installation Instructions

GeneSys Air-Cooled Screw Compressor Chiller

INSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS 15 THROUGH 20 NOMINAL TON HB B-0804

INSTALLATION INSTRUCTIONS

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) HB Ton HB Ton HB Ton NOTES, CAUTIONS AND WARNINGS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

AIR COOLED PACKAGED CHILLER

WineZone Ceiling Mount Ductless Split 15

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T15 Model

Air-Cooled Scroll Compressor Chiller

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Liebert CSU3000 Chiller

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

MODELS B1PA024, 030 AND 036

TABLE OF CONTENTS ! DANGER. Dangers indicate a hazardous situation which will result in death or serious injury if not avoided. !

MODELS E1FB180 & E1FB240

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Surna 25-Ton Chiller Operating & Maintenance Manual

Templifier Heat Recovery Water Heaters

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

INSTALLATION INSTRUCTIONS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Chillers A P P L I C AT I O N S

INSTALLATION AND OPERATING INSTRUCTIONS

User s Information and Installation Instructions

Contour TM Screw Compressors

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

horizontal air discharge outdoor discus condensing unit

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Multiaqua Chiller Manual

Transcription:

Installation, Operation and Maintenance Manual IOMM AGZ1 Group: Chiller Part Number: 330262001 Effective: October 2001 Supersedes: New Air-Cooled Scroll Compressor Water Chillers AGZ 010A AGZ 034A 10 to 34 Tons, 35 to 120 kw R-22, 60 Hertz

Table of Contents Introduction...3 General Description... 3 Inspection... 3 Installation... 3 Handling... 3 Location... 4 Service Access... 4 Vibration Isolators... 6 Chilled Water System... 6 Water Connections... 9 Refrigerant Charge... 9 Unit Component Location... 9 Glycol Solutions... 9 Evaporator Water Flow and Pressure Drop... 9 Control Layout and Operation...11 Control Center...11 Start-up and Shutdown...11 Pre Start-up...11 Start-up...11 Sequence of Operation... 12 Physical Data...13 Electrical Data... 15 Field Wiring... 15 Dimensional Data... 20 System Maintenance... 21 General... 21 Lubrication... 21 Electrical Terminals... 21 Condensers... 21 Refrigerant Sightglass... 21 Standard MicroTech II Controller 22 Table of Contents... 22 Overview... 23 General Description... 23 Using the Controller... 30 Service... 42 Thermostatic Expansion Valve... 42 Filter-Driers... 42 Liquid Line Solenoid... 42 Optional Controls... 43 Troubleshooting Chart... 45 MODEL CODE A G Z XXX A S Air-Cooled Global Series Scroll Compressor S=Packaged Evaporator M=Remote Evaporator Vintage Nominal Tons "McQuay" is a registered trademark of McQuay International 2001 McQuay International "Illustrations and data cover the McQuay International products at the time of publication and we reserve the right to make changes in design and construction at anytime without notice" 2 AGZ 010A through 034A IOMM AGZ1

Introduction General Description McQuay air-cooled water chillers are complete, self-contained automatic refrigerating units. Every unit is completely assembled, factory wired, charged, and tested. Each unit consists of air-cooled condensers, Copeland Compliant Scroll hermetic compressor, brazed plate-to-plate evaporator, and complete refrigerant piping. Liquid line components include sight-glass/moisture indicator, solenoid valve, and thermal expansion valve. Other features include a compressor heater, and evaporator heater for chilled water freeze protection. The electrical control center includes all equipment protection and operating controls necessary for automatic operation. Condenser fan motors are three-phase (except single-phase on No. 1 fan with SpeedTrol option) and started by their own contactors and have inherent overload protection. The compressor has solid-state motor protection for inherent thermal overload protection except Model AGZ 010 that has internal line breakage. Inspection Check all items carefully against the bill of lading. Inspect all units for damage upon arrival. Report shipping damage and file a claim with the carrier. Check the unit nameplate before unloading to be sure it agrees with the power supply available. Units are shipped FOB factory and McQuay is not responsible for physical damage after unit leaves the factory. Note: Unit shipping and operating weights are listed on pages 13 and 14. Installation Note: Installation is to be performed by qualified personnel who are familiar with local codes and regulations, especially concerning refrigerant release to the atmosphere. WARNING Sharp edges and coil surfaces are a potential hazard. Avoid contact with them. Handling Be careful to avoid rough handling of the unit. Do not push or pull the unit from anything other than the base. Block the pushing vehicle away from the unit to prevent damage to the sheet-metal cabinet and end frame (see Figure 1). To lift the unit, lifting slots are provided in the base of the unit. Arrange spreader bars and cables to prevent damage to the condenser coils or cabinet (see Figure 2). IOMM AGZ1 AGZ 010A through 034A 3

Figure 1, Suggested Pushing Arrangement Blocking required across full width Figure 2, Suggested Lifting Arrangement Location Unit Placement AGZ units are for outdoor applications and can be mounted on a roof or at ground level. Set units on a solid and level foundation. For roof-mounted applications, install the unit on a steel channel or I- beam frame to support the unit above the roof. For ground level applications, install the unit on a substantial base that will not settle. A one-piece concrete slab with footings extended below the frost line is recommended. Be sure the foundation is level (within 1/2 [13 mm] over its length and width). The foundation must support the operating weights listed in the Physical Data Tables on pages 13 and 14. Since its operation is affected by wind, the unit should be located so that its length is parallel with the prevailing wind. If this is not practical, use field fabricated wind deflectors. Service Access Each end of the unit must be accessible after installation for periodic service. Compressors, filterdriers, and liquid line solenoid valve are accessible from the end of the unit. High-pressure, lowpressure, and motor protector controls are on the compressor. Most operational, safety and starting controls are located in the unit control box. The fan deck with the condenser fans and motors can be removed from the top of the unit. 4 AGZ 010A through 034A IOMM AGZ1

Clearances The flow of air to and from the condenser coil must not be limited. Restricting airflow or allowing air recirculation will result in a decrease in unit performance and efficiency. There must be no obstruction above the unit that would deflect discharge air downward where it could be recirculated back to the inlet of the condenser coil. The condenser fans are propeller type and will not operate with ductwork on the fan outlet. Install the unit with enough side clearance for air entrance to the coil and for servicing. Provide service access to the evaporator, compressors, electrical control panel and piping components as shown in Figure 3. Do not block access to the unit with piping or conduit. Do not allow debris to accumulate near the unit. Air movement may draw debris into the condenser coil causing air starvation. Give special consideration to low ambient operation where snow can accumulate. Keep condenser coils and fan discharge free of snow or other obstructions to permit adequate airflow. Sound Isolation The low sound levels of the AGZ chiller are suitable for most applications. When additional sound reduction is necessary, locate the unit away from sound sensitive areas. Avoid locations beneath windows or between structures where normal operating sounds may be objectionable. Reduce structurally transmitted sound by isolating water lines, electrical conduit and the unit itself. Use wall sleeves and rubber isolated piping hangers to reduce transmission of water or pump noise into occupied spaces. Use flexible electrical conduit to isolate sound through electrical conduit. Spring isolators are effective in reducing the low amplitude sound generated by the Discus semi-hermetic compressors and for unit isolation in sound-sensitive areas. Figure 3, Clearance requirements 4 Ft. (1220mm) Clearance for Service Access 4 Ft. (1220mm) Clearance for Air Inlet 4 Ft. (1220mm) Clearance for Air Inlet 4 Ft. (1220mm) Clearance for Service Access The recommended minimum side clearance between two units is 8 feet (2440mm). The unit must not be installed in a pit or enclosure that is deeper or taller than the height of the unit unless extra space is provided. The minimum clearance on each side of the unit is 6 feet (1828mm) when installed in a pit. The pit cannot be deeper than the unit. The minimum clearance to a side wall or building taller than the unit height is 6 feet (1828mm) provided no solid wall above 6 feet (1828mm) tall is closer than 12 feet (3658mm) to the opposite side of the unit. IOMM AGZ1 AGZ 010A through 034A 5

Vibration Isolators Vibration isolators are recommended for all roof-mounted installations or wherever vibration transmission is a consideration. The isolators can be purchased from McQuay by the part numbers shown in the table. The unit should be initially on shims or blocks at the listed free height. When all piping, wiring, flushing, charging, etc. is completed, the springs are adjusted upward to loosen the blocks or shims that are then removed. A rubber anti-skid pad is part of the isolator. Installation of spring isolators requires flexible piping connections and at least three feet of flexible conduit to avoid straining the piping and transmitting vibration and noise. Table 1, Recommended Vibration Isolators AGZ UNIT 010A 034A ISOLATOR TYPE Rubber-in-shear ISOLATOR PART NO. NUMBER REQUIRED KIT of FOUR PART NO. LOCATION ISOLATOR DESCRIPTION 021639703 2 LF, RF RP-3 Green 350014857 021639701 2 LB, RB RP-3 Red 010A 017A Spring Isolators 047792726 4 350014835 All CP-1-26 020A 034A Spring Isolators Note: See dimension drawing for location of isolators 047792726 2 LF, RF CP-1-27 350014839 047792727 2 LB, RB CP-1-26 RB I RF I Control Panel LB I LF I Corner Weights AGZ Unit RF LF RB LB Model 010A 261 367 159 223 013A 372 526 184 260 017A 402 568 200 282 020A 484 621 226 291 025A 499 646 232 301 029A 621 647 326 339 034A 678 784 334 386 Chilled Water System Water Piping Local authorities can supply the installer with the proper building and safety codes required for safe and proper installation. Install piping with minimum bends and changes in elevation to minimize pressure drop. Consider the following when installing water piping: 1. Vibration eliminators to reduce vibration and noise transmission to the building. 2. Shutoff valves to isolate the unit from the piping system during unit servicing. 3. Manual or automatic air vent valves at the high points of the system. Install drains at the lowest points in the system. 6 AGZ 010A through 034A IOMM AGZ1

4. A means of maintaining adequate system water pressure (expansion tank or regulating valve). 5. Temperature and pressure indicators located at the unit to aid in unit servicing. Pressure gauge taps must be installed in the chilled water inlet and outlet piping or as shown in Figure 4. 6. A strainer or other means of removing foreign matter from the water before it enters the pump. Place the strainer far enough upstream to prevent cavitation at the pump inlet (consult pump manufacturer for recommendations). The use of a strainer will prolong pump life and keep system performance up. 7. A 40-mesh strainer is required in the water line just before the inlet of the evaporator. This will help prevent foreign material from entering and decreasing the performance of the evaporator. CAUTION If separate disconnect is used for the 110V supply to the evaporator heating cable, mark the disconnect clearly to ensure disconnect is not accidentally shut off during cold seasons. This could cause a failure of the evaporator. 8. The brazed plate evaporator has a thermostat and heating cable to prevent freeze-up down to -20 F (-29 C). It is suggested that the heating cable be wired to a separate 110V supply circuit. As shipped from the factory, the heating cable is wired to the control circuit. Protect all water piping to the unit from freezing. 9. If the unit is used as a replacement chiller on a previously existing piping system, flush the system thoroughly before unit installation. Regular water analysis and chemical water treatment on the evaporator is recommended immediately at equipment start-up. 10. When glycol is added to the water system for freeze protection, the refrigerant suction pressure will be lower, cooling performance less, and water side pressure drop greater. If the percentage of glycol is high, or if propylene is used instead of ethylene glycol, the added pressure drop and loss of performance could be substantial. Reset the freezestat and low leaving water alarm temperatures. The freezestat is factory set to default at 38 F (3.3 C). Reset the freezestat setting to approximately 4 to 5 degrees F (2.3 to 2.8 degrees C) below the leaving chilled water setpoint temperature. See the section titled Glycol Solutions on page 9 for additional information concerning glycol. 11. Perform a preliminary leak check before insulating the piping and filling the system. 12. Piping insulation should include a vapor barrier to prevent condensation and possible damage to the building structure. Figure 4, Typical Field Evaporator Water Piping Air Vent Inlet Strainer P Vibration Eliminators Isolation Valves Outlet Flow Switch Drain NOTES: 1. Chilled water piping within the unit enclosure must be insulated in the field. 2. Piping should be supported independently of the unit and be installed per local codes. IOMM AGZ1 AGZ 010A through 034A 7

System Volume It is important to have adequate water volume in the system to provide an opportunity for the chiller to sense a load change, adjust to the change and stabilize. As the expected load change becomes more rapid, a greater water volume is needed. The system water volume is the total amount of water in the evaporator, air handling products and associated piping. If the water volume is too low, operational problems can occur, including rapid compressor cycling, rapid loading and unloading of compressors, erratic refrigerant flow in the chiller, improper motor cooling, shortened equipment life and other undesirable occurrences. For normal comfort cooling applications, where the cooling load changes relatively slowly, we recommend a minimum system volume of five minutes times the flow rate (GPM). For example, if the design chiller flow rate is 120 GPM, we recommend a minimum system volume of 600 gallons (120 GPM x 5 minutes). Since there are many other factors that can influence performance, systems may successfully operate below these suggestions. However, as the water volume decreases below these suggestions, the possibility of problems increases. Variable Chilled Water flow Variable chilled water flow systems are not recommended for this class of equipment due to limited unloading capability. Flow Switch Mount a water flow switch in the leaving water line to shut down the unit when water Figure 5, Flow Switch Installation flow is interrupted. A flow switch is available from McQuay (part number 017503300). It is a paddle type switch and adaptable to pipe sizes down to 1 1/4 (32mm) nominal. Certain minimum flow rates are required to close the switch and are listed in Table 2. Install the switch as shown in Figure 5. Connect the normally open contacts of the flow switch in the unit control center at terminals 4 and 5. There is also a set of normally closed contacts on the switch that can be used for an indicator light or an alarm to indicate when a no-flow condition exists. Freeze protect any flow switch that is installed outdoors. Follow installation instructions provided with the flow switch. Calibrate the flow switch to open at one-half of nominal flow rate. NOTE: Differential pressure switches are not recommended for outdoor installation. Table 2, Flow Switch Settings Pipe Size inch 1 1/4 1 1/2 2 2 1/2 3 4 mm 32 38 51 63 76 102 gpm 4.8 6.3 9.9 15.3 24.4 33.3 Flow Minimum Lpm 18.2 22.7 37.5 57.9 92.4 126.0 Adjustment No gpm 3.0 3.6 5.9 9.5 15.4 21.1 Flow Lpm 11.3 13.6 22.3 36.0 58.3 79.9 gpm 7.7 10.0 15.8 23.7 35.5 61.4 Flow Maximum Lpm 29.1 37.9 59.8 89.7 134.4 232.4 Adjustment No gpm 5.9 7.0 11.0 17.0 29.2 37.7 Flow Lpm 22.3 26.5 41.6 64.3 110.5 142.7 8 AGZ 010A through 034A IOMM AGZ1

Water Connections The unit has 3-inch holes for the chilled water piping to enter the unit. The connections are made to the evaporator water connections located within the unit. Water piping within the unit must be field insulated. Refrigerant Charge All units are designed with HCFC-22. See the nameplate for specific refrigerant used. Units are shipped with an operating charge. The operating charge (using HCFC-22) for each unit is shown in in the Physical Data Tables on pages 13 and 14. Unit Component Location Control Panel Tandem Scroll Compressors Evaporator Filter Drier Charging Valve Solenoid Valve, Expansion Valve Optional Hot Gas Bypass Valve Glycol Solutions The use of glycol antifreeze solutions will decrease unit capacity and increase the pressure drop through the cooler. See Product Manual PM AGZ1 for specific ratings and correction factors. CAUTION Do not use automotive grade antifreeze. Industrial grade glycols must be used. Automotive antifreeze contains inhibitors that will cause plating on the copper tubes within the chiller evaporator. The type and handling of glycol used must be consistent with local codes. Evaporator Water Flow and Pressure Drop Evaporator flow rate must fall between the minimum and maximum values shown in the evaporator pressure drop curve, Figure 6. Flow rates outside of these limits result in a chilled water Delta-T outside the operating range of the controller. Measure the chilled water pressure drop through the evaporator at field-installed pressure taps. It is important not to include the effect of valves or strainers in these readings. Varying chilled water flow through the evaporator while the compressors are operating is not recommended. IOMM AGZ1 AGZ 010A through 034A 9

Figure 6, Evaporator Water Pressure Drop Curve AGZ 010 AGZ 020 AGZ 025 AGZ 029 AGZ 034 AGZ 017 AGZ 013 AGZ Model Flow Rate gpm L/s Minimum Flow Nominal Flow Maximum Flow Pressure Drop ft. kpa Flow Rate gpm L/s Pressure Drop ft. kpa Flow Rate gpm L/s Pressure Drop ft. kpa 010 15.0 0.9 2.4 7.1 24.0 1.5 5.8 17.3 40.0 2.5 15.2 45.5 013 19.5 1.2 1.5 4.5 31.2 2.0 3.7 11.0 52.0 3.3 9.6 28.9 017 24.0 1.5 1.7 5.0 38.4 2.4 4.1 12.2 64.0 4.0 10.7 32.1 020 30.0 1.9 2.3 6.8 48.0 3.0 5.6 16.7 80.0 5.0 14.5 43.4 025 34.5 2.2 1.8 5.3 55.2 3.5 4.3 13.0 92.0 5.8 11.4 34.3 029 40.7 2.6 1.7 5.0 65.0 4.1 4.0 12.1 108.4 6.8 10.9 32.6 034 49.8 3.1 1.6 4.7 79.7 5.0 3.9 11.7 132.8 8.4 10.4 31.2 10 AGZ 010A through 034A IOMM AGZ1

Control Layout and Operation Control Center All electrical controls are enclosed in a weatherproof control center with tool-locked, hinged access doors. The left-hand section contains the microprocessor controller and control input and output terminals. All high-voltage components are located on the right side of the panel. Control Transformer ON/OFF Switch 24-Volt Trans. MicroTech II SpeedTrol Location Field Connection Terminals Start-up and Shutdown Compressor Contactors Non-Fused Disc. or Power Block Fan Contactors Fan Protection Pre Start-up 1. The chilled-water system should be flushed and cleaned. Proper water treatment is required to prevent corrosion and organic growth. 2. Open all electric disconnects and check all electric connections for tightness. 3. Inspect all water piping for flow direction and correct connections at the evaporator. 4. Verify thermostat water temperature sensor is installed in the leaving water line (supply to building). On all AGZ units the sensor well and sensor are factory mounted. 5. Check compressor oil level. The oil level should be visible in the oil sightglass. 6. Check voltage of the unit power supply and make certain voltage is within ±10% of nameplate rating. Check unit power supply wiring for proper ampacity and a minimum insulation temperature of 75 C. Check for proper phasing using a phase sequence meter. 7. Verify all mechanical and electrical inspections have been completed according to local codes. 8. Open control stop switch S1(off). Turn on the main power and control disconnect switches. This will energize crankcase heaters. Wait at least 24 hours before starting up unit. 9. Open all water flow valves and start the chilled water pump. Check all piping for leaks and vent the air from the evaporator as well as from the system piping. Flush the evaporator and system piping to obtain clean, noncorrosive water in the evaporator. Start-up 1. Set temperature controller to the desired chilled water temperature. Set the chilled water Delta-T. 2. Start auxiliary equipment by turning on the following: time clock (if present), ambient thermostat and/or remote on/off switch, chilled water pump. 3. If the controller calls for cooling, the unit will begin the start-up sequence. 4. After running the unit for a short time, check the oil level in the compressor (1/4 to 1/3 of the glass), rotation of fans, and flashing in refrigerant sightglass. IOMM AGZ1 AGZ 010A through 034A 11

5. Verify superheat temperature is at the factory setting of 8 to 12 degrees F (4.4 to 6.7 degrees C). 6. After system performance has stabilized, complete the current AGZ Start-Up Form (obtainable from the local McQuay sales office) to establish inception of warranty benefits. Return the form to McQuay International through your sales representative. Sequence of Operation The following sequence of operation is typical for Models AGZ 010A through AGZ 034A. It can vary depending upon options. Start-Up With the control circuit power on, 115V power is applied through the control circuit fuse F1 to the compressor crankcase heaters, the compressor motor protections and the primary of the 24V control circuit transformer. The 24V transformer provides power to the microprocessor controller. When a remote time clock, manual switch, or the unit controller turns on the chilled water pump, the flow switch closes and satisfies the flow requirement. If the chilled water temperature is above the stage-on temperature, and all equipment protection devices are closed, the unit will start. The controller will operate the unit in response to the leaving chiller water temperature, reset signals that may be present and any equipment protection signals that may occur. Equipment Protection Alarms The following conditions will shut down the unit and activate the alarm circuit: No evaporator water flow Low evaporator pressure High condenser pressure Motor protection system Phase voltage protection (Optional) Outside ambient temperature Evaporator freeze protection Sensor failures The following alarms will limit unit operation: Condenser pressure stage down, unloads unit at high discharge pressures Low ambient lockout, shuts off unit at low ambient temperatures Low evaporator pressure hold, holds stage #1 until pressure rises Low evaporator pressure unload, shuts off stage #2 Unit Enable Selection Enables unit operation from local keypad, digital input, or Building Automation System. Unit Mode Selection Selects standard cooling, ice, glycol, or test operation mode. Condenser fan control Control of condenser fans is provided by the MicroTech II controller. The control steps condenser fans based on discharge pressure. Shutdown As the leaving water control is satisfied, it will stage off the lag compressor unloading the unit. The second stage will de-energize the liquid line solenoid valve SV1 and shut off the lead compressor. The compressor crankcase heaters will energize when the compressors shut off, keeping the small amount of refrigerant in the plate heat exchanger from migrating to the compressor. See page 38 for detailed explanation of compressor staging. 12 AGZ 010A through 034A IOMM AGZ1

Physical Data Table 3, Physical Data, AGZ 010A through 017A BASIC DATA PHYSICAL DATA AGZ MODEL NUMBER 010A 013A 017A Unit Capacity @ ARI Conditions (1), Tons (kw) 9.8 (34.3) 13.3 (46.6) 15.9 (55.7) Number Of Refrigerant Circuits 1 1 1 Unit Operating Charge, R-22, Lb. (kg) 22.0 (10.0) 24.0 (10.9) 31.0 (14.1) Cabinet Dimensions, LxWxH, In. 73.6 x 46.3 x 50.8 73.6 x 46.3 x 50.8 73.6 x 46.3 x 50.8 Cabinet Dimensions, LxWxH, (mm) (1869) x (1176) x (1289) (1869) x (1176) x (1289) (1869) x (1176) x (1289) Unit Operating Weight, Lb. (kg) 1090 (495) 1340 (608) 1450 (658) Unit Shipping Weight, Lb. (kg) 1160 (527) 1400 (636) 1515 (688) Add'l Weight If Copper Finned Coils, Lb. (kg) 220 (99.7) 220 (99.7) 220 (99.7) COMPRESSORS Type Scroll Scroll Scroll Nominal Tons Per Compressor 6.0 / 6.0 7.5 / 7.5 9.0 / 9.0 Oil Charge Per Compressor, Oz. (g) 60 (1701) 140 (3969) 140 (3969) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DSPLACEMENT Standard Staging 0 50 100 0 50 100 0 50 100 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area, One of Two Sides, Sq. Ft. (M 2 ) 30.3 (2.8) 30.3 (2.8) 30.3 (2.8) Finned Height x Finned Length, In. 84 x 52 84 x 52 84 x 52 Finned Height x Finned Length, (mm) (2134) x (1321) (2134) x (1321) (2134) x (1321) Fins Per Inch x Rows Deep 16 x 2 16 x 2 16 x 3 Pumpdown Capacity Lb. (kg) 35.3 (16.0) 35.3 (16.0) 50.3 (22.8) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 2 26 (660) 2 26 (660) 2 26 (660) Number Of Motors - HP (kw) 2 1.0 (0.75) 2 1.0 (0.75) 2 1.0 (0.75) Fan And Motor RPM, 60 Hz 1140 1140 1140 60 Hz Total Unit Airflow, CFM (l/s) 13950 (6584) 13950 (6584) 12000 (5664) DIRECT EXPANSION EVAPORATOR - BRAZED PLATE-TO-PLATE Connection Size Victaulic, In. (mm) 2 (51) 2 (51) 2 (51) Water Volume, Gallons (L).94 (3.6) 1.66 (6.3) 2.00 (7.6) Maximum Refrigerant Working Pressure, psig (kpa) 450 (3103) 450 (3103) 450 (3103) Maximum Water Pressure, psig (kpa) 350 (2413) 350 (2413) 350 (2413) NOTE: Nominal capacity based on 95 F ambient air and 54 F/44 F water range. IOMM AGZ1 AGZ 010A through 034A 13

Table 4, Physical Data, AGZ 020A through 034A PHYSICAL DATA AGZ MODEL NUMBER 020A 025A 029A 034A BASIC DATA Unit Capacity @ ARI Conditions (1), Tons (kw) 20.4 (71.4) 22.7 (79.5) 28.2 (98.7) 34.0 (119.0) Number Of Refrigerant Circuits 1 1 1 1 Unit Operating Charge, R-22, Lb. (kg) 34.0 (15.4) 36.0 (16.3) 47.0 (21.3) 50.0 (22.7) Cabinet Dimensions, LxWxH, In. 106.2x 46.3 x 50.8 106.2x 46.3 x 50.8 106.2x 46.3 x 58.8 106.2x 46.3 x 58.8 Cabinet Dimensions, LxWxH, (mm) (2697) x (1176) x (1289) (2697) x (1176) x (1289) (2697) x (1176) x (1493) (2697) x (1176) x (1493) Unit Operating Weight, Lbs. (kg) 1620 (735) 1675 (760) 1930 (876) 2180 (990) Unit Shipping Weight, Lbs. (kg) 1700 (772) 1750 (794) 2000 (908) 2230 (1012) Add'l Weight If Copper Finned Coils, Lb. (kg) 350 (159) 350 (159) 435 (197) 435 (197) COMPRESSORS Type Scroll Scroll Scroll Scroll Nominal Horsepower 10.0 / 13.0 13.0 / 13.0 15.0 / 15.0 20.0 / 20.0 Oil Charge Per Compressor, Oz. (g) 140 (3969) 140 (3969) 140 (3969) 296 (8392) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging 0 45-100 0 50 100 0 50 100 0 50 100 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area, One of Two Sides, Sq. Ft. (M 2 ) 49.0 (4.6) 49.0 (4.6) 58.3 (5.4) 58.3 (5.4) Finned Height x Finned Length, In. 84 x 84 84 x 84 100 x 84 100 x 84 Finned Height x Finned Length, (mm) (2134) x (2134) (2134) x (2134) (2545 ) x (2134) (2545 ) x (2134) Fins Per Inch x Rows Deep 16 x 2 16 x 2 16 x 3 16 x 3 Pumpdown Capacity lb. (kg) 53.1 (24.0) 53.1 (24.0) 90.7 (41.1) 92.8 (42.0) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 3 26 (660) 3 26 (660) 3 26 (660) 3 26 (660) Number Of Motors - HP (kw) 3 1.0 (0.75) 3 1.0 (0.75) 3 1.0 (0.75) 3 1.0 (0.75) Fan And Motor RPM, 60 Hz 1140 1140 1140 1140 60 Hz Total Unit Airflow, CFM (l/s) 20925 (9877) 20925 (9877) 19800 (9346) 19800 (9346) DIRECT EXPANSION EVAPORATOR - BRAZED PLATE-TO-PLATE Connection Size Victaulic, In. (mm) 2 (51) 2 (51) 2 (51) 2 (51) Water Volume, Gallons (L) 2.16 (8.2) 3.05 (11.5) 4.00 (15.1) 5.55 (21.0) Max. Refrigerant Working Pressure, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) Maximum Water Pressure, psig (kpa) 350 (2413) 350 (2413) 350 (2413) 350 (2413) NOTE: Nominal capacity based on 95 F ambient air and 54 F/44 F water range. 14 AGZ 010A through 034A IOMM AGZ1

Electrical Data Field Wiring Wiring must comply with all applicable codes and ordinances. Warranty is void if wiring is not in accordance with specifications. Copper wire is required for all power lead terminations at the unit. AGZ 010A through AGZ 034A units have single point power connection. A single field supplied fused disconnect is required. The control transformer is factory mounted. If the evaporator heater is on a separate disconnect switch from the main unit power supply, the unit may be shut down without defeating the freeze protection provided by the evaporator heater. Table 5. AGZ 010A 034A Electrical Data Single Point AGZ Unit Size Volts Hz. Minimum Circuit Ampacity (MCA) Quantity Power Supply Field Fuse Size Field Wire Hub or HACR Breaker Size Wire Gauge Quantity Nominal Size In. (mm) Recommended Maximum 208 54 3 6 1 1.00 (25) 60 70 010A 230 54 3 6 1 1.00 (25) 60 70 60 460 26 3 10 1 1.00 (25) 30 35 575 23 3 10 1 1.00 (25) 30 30 208 65 3 6 1 1.00 (25) 80 80 013A 230 65 3 6 1 1.00 (25) 80 80 60 460 34 3 10 1 1.00 (25) 40 45 575 27 3 10 1 1.00 (25) 30 35 208 79 3 4 1 1.00 (25) 90 100 017A 230 79 3 4 1 1.00 (25) 90 100 60 460 41 3 8 1 1.00 (25) 45 50 575 33 3 10 1 1.00 (25) 40 40 208 103 3 2 1 1.25 (32) 125 125 020A 230 103 3 2 1 1.25 (32) 125 125 60 460 53 3 6 1 1.00 (25) 60 70 575 45 3 8 1 1.00 (25) 50 60 208 110 3 2 1 1.25 (32) 125 150 025A 230 110 3 2 1 1.25 (32) 125 150 60 460 58 3 6 1 1.00 (25) 70 80 575 48 3 8 1 1.00 (25) 60 60 208 136 3 1/0 1 1.50 (38) 150 175 029A 230 136 3 1/0 1 1.50 (38) 150 175 60 460 62 3 6 1 1.00 (25) 70 80 575 58 3 6 1 1.00 (25) 70 70 208 175 3 2/0 1 1.50 (38) 200 225 034A 230 175 3 2/0 1 1.50 (38) 200 225 60 460 88 3 3 1 1.25 (32) 100 110 575 72 3 4 1 1.00 (25) 90 100 See "Electrical Notes" on page 18. IOMM AGZ1 AGZ 010A through 034A 15

Table 6, AGZ 010A 034A Compressor and Condenser Fan Motor Amp Draw AGZ Unit Size Volts Hz. Rated Load Amps Compressors No. 1 No. 2 Fan Motor (Each) No. of Fan Mtrs Locked Rotor Amps Fan Motor Compressors Across-The-Line (Each) No. 1 No. 2 208 18.6 18.6 5.8 2 23.7 156 156 010A 230 18.6 18.6 5.8 2 21.4 156 156 60 460 9.0 9.0 2.8 2 10.7 75 75 575 7.4 7.4 3.0 2 11.5 54 54 208 23.7 23.7 5.8 2 23.7 189 189 013A 230 23.7 23.7 5.8 2 21.4 189 189 60 460 12.5 12.5 2.8 2 10.7 99 99 575 9.1 9.1 3.0 2 11.5 74 74 208 29.9 29.9 5.8 2 23.7 232 232 017A 230 29.9 29.9 5.8 2 21.4 232 232 60 460 15.3 15.3 2.8 2 10.7 125 125 575 11.6 11.6 3.0 2 11.5 100 100 208 33.6 41.0 5.8 3 23.7 278 350 020A 230 33.6 41.0 5.8 3 21.4 278 350 60 460 16.5 21.8 2.8 3 10.7 127 158 575 13.7 17.3 3.0 3 11.5 100 125 208 41.0 41.0 5.8 3 23.7 350 350 025A 230 41.0 41.0 5.8 3 21.4 350 350 60 460 21.8 21.8 2.8 3 10.7 158 158 575 17.3 17.3 3.0 3 11.5 125 125 208 52.6 52.6 5.8 3 23.7 425 425 029A 230 52.6 52.6 5.8 3 21.4 425 425 60 460 23.7 23.7 2.8 3 10.7 187 187 575 21.7 21.7 3.0 3 11.5 148 148 208 70 70 5.8 3 23.7 448 448 034A 230 70 70 5.8 3 21.4 448 448 60 460 35 35 2.8 3 10.7 225 225 575 28 28 3.0 3 11.5 180 180 See "Electrical Notes" on page 18. 16 AGZ 010A through 034A IOMM AGZ1

Table 7, AGZ 010A 034A Field Wiring Data, Single Point Power AGZ UNIT SIZE Volts HZ. Maximum Terminal Amps (1) Wiring to Standard Power Block Terminal Connector Wire Range (Copper Wire Only) (3) Wiring to Optional Disconnect Switch Disconnect Size (2) Connector Wire Range (Copper Wire Only) (3) 208 175 14 GA 2/0 100 8 GA 2/0 010A 230 175 14 GA 2/0 100 8 GA 2/0 60 460 175 14 GA 2/0 63 14 GA 1 GA 575 175 14 GA 2/0 63 14 GA 1 GA 208 175 14 GA 2/0 100 8 GA 2/0 013A 230 175 14 GA 2/0 100 8 GA 2/0 60 460 175 14 GA 2/0 45 14 GA 4 GA 575 175 14 GA 2/0 63 14 GA 1 GA 208 175 14 GA 2/0 175 6GA 300 kcmil 017A 230 175 14 GA 2/0 175 6GA 300 kcmil 60 460 175 14 GA 2/0 45 14 GA 4 GA 575 175 14 GA 2/0 63 14 GA 1 GA 208 175 14 GA 2/0 200 6GA 300 kcmil 020E 230 175 14 GA 2/0 200 6GA 300 kcmil 60 460 175 14 GA 2/0 160 8 GA 1/0 575 175 14 GA 2/0 160 8 GA 1/0 208 175 14 GA 2/0 200 6GA 300 kcmil 025A 230 175 14 GA 2/0 200 6GA 300 kcmil 60 460 175 14 GA 2/0 160 8 GA 1/0 575 175 14 GA 2/0 160 8 GA 1/0 208 175 14 GA 2/0 200 6GA 300 kcmil 029E 230 175 14 GA 2/0 200 6GA 300 kcmil 60 460 175 14 GA 2/0 160 8 GA 1/0 575 175 14 GA 2/0 160 8 GA 1/0 208 335 6 GA 400 kcmil N/A ----- 034A 230 335 6 GA 400 kcmil 200 6GA 300 kcmil 60 460 175 14 GA 2/0 175 6GA 300 kcmil 575 175 14 GA 2/0 175 6GA 300 kcmil NOTES: 1. "Size" is the maximum amperage rating for the terminals or the main electrical device. 2. "Size" is the disconnect part number and not the amperage rating for the terminals or the main electrical device. 3. "Connection" is the range of wire sizes that the terminals on the electrical device will accept. See page 18 for additional Electrical Notes. IOMM AGZ1 AGZ 010A through 034A 17

Notes for Electrical Data Single Point" 1. Field Fuse Size for recommended and maximum is based on use of a time-delay fuse. 2. Unit wire size ampacity (MCA) is equal to 125% of the largest compressor-motor RLA plus 100% of RLA of all other loads in the circuit including the control transformer. 3. Since the control transformer is furnished, no separate 115v power is required. 4. If a separate 115V power supply is used for the control circuit, then the wire sizing amps is 2 Amps. 5. Recommended power lead wire sizes for 3 conductors per conduit are based on 100% conductor ampacity in accordance with NEC. Voltage drop has not been included. Therefore, it is recommended that power leads be kept short. All terminal block connections must be made with copper (type THW) wire. 6. Single conductors should be used for power connections as listed under Recommended Power Lead Wire Size. 7. Recommended Fuse Sizes are selected at approximately 150% to 225% of the largest compressor RLA, plus 100% of all other loads in the circuit. 8. Maximum Fuse Sizes are selected at approximately 225% of the largest compressor RLA, plus 100% of all other loads in the circuit. 9. The recommended power lead wire sizes are based on an ambient temperature of 86 F. Ampacity correction factors must be applied for other ambient temperatures. Refer to the National Electrical Code Handbook. Power Limitations: 1. Voltage within 10% of nameplate rating. 2. Phase imbalance within 3%. Notes for Compressor and Condenser Fan Amp Draw : 1. Compressor RLA values are for wiring sizing purposes only but do not reflect normal operating current draw at rated capacity. Notes for Field Wiring Data - Single Point Power: 1. Single point power supply requires a single disconnect to supply electrical power to the unit. This power must be fused. 2. All field wiring to unit power block or non-fused disconnect switch must be copper. 3. All field wire size values given in table apply to 75 C rated wire per NEC. 18 AGZ 010A through 034A IOMM AGZ1

Figure 7, AGZ 010A through AGZ 034A, Typical Field Wiring Diagram DISCONNECT (BY OTHERS OR FACTORY OPTION) UNIT MAIN TERMINAL BLOCK GND LUG 3 PHASE POWER SUPPLY TO COMPRESSOR(S) AND FAN MOTORS FUSED CONTROL CIRCUIT TRANSFORMER 120 VAC DISCONNECT (BY OTHERS) TB1-20 N OPTIONAL REMOTE 120 VAC CONTROL POWER 10A FUSE TB1 SEPARATE EVAPORATOR HEATER POWER OPTION 120VAC (BY OTHERS) N DISCONNECT (BY OTHERS) (BY OTHERS) 10A FUSE (BY OTHERS) 1 2 6 15 CONTROL CIRCUIT FUSE MJ MJ IF SEPARATE EVAPORATOR HEATER POWER OPTION IS USED - REMOVE MECHANICAL JUMPER BETWEEN TB1-5 AND TB1-6 & TB1-15 AND TB1-16 ALARM BELL OPTION FIELD WIRED ALARM BELL RELAY CHW PUMP RELAY (BY OTHERS) 120 VAC 1.0 AMPS MAX 12 17 11 N 120 VAC 120 VAC REMOTE STOP (BY OTHERS) CHW FLOW SWITCH --MANDATORY-- (BY OTHERS) TIME OFF CLOCK AUTO ON MANUAL 17 GND TB2 25 843 35 IF REMOTE STOP CONTROL IS USED, REMOVE LEAD 843 FROM TERM 25 TO 35. NOR. OPEN PUMP AUX. CONTACTS (OPTIONAL) 26 36 4-20 MA FOR CHW RESET (BY OTHERS) 22 ICE MODE SWITCH (BY OTHERS) OFF AUTO ON MANUAL 33 34 28 38 GND Rx-/Tx- Rx+/Tx+ J11 1 2 * COMMUNICATION PORT 330258401 GND 3 Note: See control and power wiring diagrams on unit control panel for specific unit information. IOMM AGZ1 AGZ 010A through 034A 19

.. Dimensional Data Figure 8, AGZ 010A through 017A ACCESS PANEL 3.00 (78.20) QTY. 2 EVAP. INLET EVAP. OUTLET 31.70 (805.18) 11.27 (286.26) Z 5.11 (129.79) 0.875 (22.23) POWER ENTRY KNOCKOUT (OTHER SIDE) 0.875 (22.23) CONTROL ELECTRICAL KNOCKOUT 39.63 (1006.6) 24.00 (609.6) AIR FLOW 46.14 AIR (1171.96) FLOW CONTROL PANEL ACCESS DOORS ACCESS DOOR POWER ENTRY AIR FLOW 51.00 (1295.40) 14.59 (370.59) Y 73.57 (1868.68) 49.06 (1246.12) 46.20 (1173.48) 21.12 (536.45) 3.88 (98.55) MOUNTING HOLES QTY. 4 01.00 30.91 (785.11) 7.75 MOUNTING (196.85) HOLES X AGZ Unit Size Center of Gravity Inches (mm) Evaporator Connection Size Inch Victaulic X Y Z AGZ 010 27.8 (706.1) 22.7 (576.6) 19.2 (487.7) 2 AGZ 013 24.3 (617.2) 22.5 (571.5) 19.1 (485.1) 2 AGZ 017 24.4 (619.8) 22.4 (569.0) 19.1 (485.1) 2 Figure 9, AGZ 020A through 034A ACCESS PANEL 3.00 (76.20) QTY. 2 EVAP. INLET EVAP. OUTLET 31.70 (805.18) 11.27 (286.26) Z 5.11 (129.79) 0.875 (22.23) POWER ENTRY KNOCKOUT (OTHER SIDE) A 0.875 (22.23) CONTROL ELECTRICAL KNOCKOUT B AIR FLOW AIR FLOW CONTROL PANEL ACCESS DOORS ACCESS DOOR 46.14 (1171.96) POWER ENTRY AIR FLOW C 14.59 (370.59) Y 49.0 (1246.12) MOUNTING HOLES QTY. 6 01.00 (25.40) 106.15 (2696.21) 49.06 (1246.12) 46.20 (1173.48) 21.12 (536.45) 3.88 (98.55) 30.91 (785.11) 7.75 MOUNTING (196.85) HOLES X AGZ Unit Size Dimensions Inches (mm) Center of Gravity Inches (mm) Evaporator Connection Size Inch Victaulic A B C X Y Z AGZ 020 24.0 (609.6) 39.6 (1006.6) 51.0 (1295.4) 33.8 (858.5) 22.4 (569.0) 20.2 (513.1) 2 AGZ 025 24.0 (609.6) 39.6 (1006.6) 51.0 (1295.4) 33.7 (856.0) 22.2 (564.0) 20.1 (510.5) 2 AGZ 029 33.0 (838.2) 47.6 (1209.8) 59.0 (1498.6) 36.5 (927.1) 23.1 (586.7) 22.6 (574.0) 2 AGZ 034 33.0 (838.2) 47.6 (1209.6) 59.0 (1498.6) 35.0 (889.0) 23.1 (586.7) 21.4 (543.6) 2 20 AGZ 010A through 034A IOMM AGZ1

System Maintenance General On initial start-up and periodically during operation, it will be necessary to perform certain routine service checks. Among these are taking electric leg readings. Some readings are readily available on the MicroTech II display. Lubrication No routine lubrication is required on the AGZ units. The fan motor bearings are of the permanently lubricated type and require no lubrication. Electrical Terminals WARNING Electric shock hazard. Turn off all power before continuing with following service. Normal heating and cooling of the wire will cause terminals to loosen. Retighten all power electrical terminals every six months. Condensers Condensers are air-cooled and constructed with 3/8 (9.5mm) O.D. internally finned copper tubes bonded in a staggered pattern into slit aluminum fins. No maintenance is ordinarily required except the occasional removal of dirt and debris from the outside surface of the fins. Use locally purchased foaming condenser coil cleaners for periodic cleaning of the coil. Condenser cleaners may contain harmful chemicals, be careful when using cleaners. Care should be taken not to damage the fins during cleaning. All chemical cleaners should be thoroughly rinsed from the coils. Refrigerant Sightglass Observe the refrigerant sightglass monthly. A clear glass of liquid indicates adequate sub-cooled refrigerant charge in the system to ensure proper feed through the expansion valve. Bubbling refrigerant in the sightglass indicates the system is short of refrigerant charge. Sub-cooling should be verified to prevent overcharging. Refrigerant gas flashing in the sightglass could also indicate an excessive pressure drop in the line, possibly due to a clogged filter-drier or a restriction elsewhere in the system. The sightglass indicates what moisture condition corresponds to a given element color. If the sightglass does not indicate a dry condition after about 12 hours of operation, the refrigerant or oil should be tested for moisture. IOMM AGZ1 AGZ 010A through 034A 21

Standard MicroTech II Controller Table of Contents Overview...23 General Description...23 Compressor Motor Description...23 FanTrol Head Pressure Control...23 Inputs/Outputs...24 Setpoints...24 Equipment Protection Alarms...26 Limit Alarms...26 Unit Enable...26 Unit Mode Selection...27 Low Ambient Start...27 Automatic Adjusted Range Limits...28 Compressor Staging Parameters...28 Using the Controller...30 Display and Keyboard...30 Getting Started...30 Menu Screens...31 Menu Matrix...33 View Screens Defined...34 Alarm Screens Defined...36 Set Screens Defined...36 22 AGZ 010A through 034A IOMM AGZ1

Overview MicroTech II s state-of-the-art design will not only permit the chiller to run more efficiently, but will also simplify troubleshooting if a system failure occurs. Every MicroTech II controller is programmed and tested prior to shipment to contribute to a trouble-free start-up. Operator-friendly The MicroTech II menu structure is separated into three distinct categories, which provide the operator or service technician with a full description of current unit status, control parameters, and alarms. Security protection prevents unauthorized changing of the setpoints and control parameters. MicroTech II continuously performs self-diagnostic checks, monitoring system temperatures, pressures and protection devices, and will automatically shut down a compressor or the entire unit should a fault occur. The cause of the shutdown will be retained in memory and can be easily displayed in plain English for operator review. The MicroTech II chiller controller will also retain and display the time the fault occurred. In addition to displaying alarm diagnostics, the MicroTech II chiller controller also provides the operator with a warning of limit (pre-alarm) conditions. Staging The two scroll compressors are staged on and off as a function of leaving chilled water temperature. Lead/lag is automatic and switched every ten starts. General Description Compressor Motor Protection AGZ 013 034: The solid-state compressor motor protector module incorporates a 2-minute timeoff relay utilizing the bleed-down capacitor principle. Any time the protection system opens or power to the module is interrupted, the 2-minute time-off delay is triggered and the module will not reset for two minutes. Once the 2-minute period has passed the motor protector contacts M1 and M2 reset, provided the protection system is satisfied and power is applied to the module. Note: If the power circuit is broken once the 2-minute period is passed, the pilot circuit will reset without delay when power is reapplied. AGZ 010: The model AGZ 010 compressor has internal line breakage with automatic reset. FanTrol Head Pressure Control FanTrol is the standard method of head pressure control that automatically cycles the condenser fan motors in response to condenser pressure. This function is controlled by the microprocessor, maintains head pressure and allows the unit to run at low ambient air temperatures down to 35 F (1.7 C). Fans are staged as follows: Table 8, Fan Staging Pressures Fan Two-Fan Unit Three-Fan Unit Stage #1 On 150 psig, Off with unit On 150 psig, Off with unit Stage #2 On 290 psig, Off 170 psig On 290 psig, Off 170 psig Stage #3 On 310 psig, Off 180 psig Note: Fan #1 is on with first compressor above 75 F (24 C). IOMM AGZ1 AGZ 010A through 034A 23

Inputs/Outputs Table 9, Inputs and Outputs Analog Inputs # Description Signal Source Range 1 Reset of Leaving Water Temperature 4-20 ma Current 0-(10 to 80 F) 2 Evaporator Refrigerant Pressure 0.1 to 0.9 VDC 0 to 132 psi 3 Condenser Refrigerant Pressure 0.1 to 0.9 VDC 3.6to 410 psi 4 Leaving Evaporator Water Temperature Thermister (10k at 77 F, 25 C) -58 to 212 F 5 Outside Ambient Temperature Thermister (10k at 77 F, 25 C) -58 to 212 F Analog Outputs # Description Output Signal Range 1 None Digital Inputs # Description Signal Signal 1 Unit OFF Switch 0 VAC (Stop) 24 VAC (Auto) 2 Remote Start/Stop 0 VAC (Stop) 24 VAC (Start) 3 Evaporator Water Flow Switch 0 VAC (No Flow) 24 VAC (Flow) 4 Motor Protection 0 VAC (Fault) 24 VAC (No Fault) 5 Ice Mode Switch 0 VAC (Normal) 24 VAC (Ice) 6 Phase Voltage Fault 0 VAC (Fault) 24 VAC (No Fault) 7 Open 8 Open Digital Outputs # Description Load Output OFF Output ON 1 Alarm Alarm Indicator Alarm OFF Alarm ON 2 Evaporator Water Pump Pump Contactor Pump OFF Pump ON 3 Liquid Line Solenoid Cooling OFF Cooling ON 4 Motor Control Relay #1 Starter Compressor OFF Compressor ON 5 Motor Control Relay #2 Starter Compressor OFF Compressor ON 6 Condenser Fan #1 Fan Contactor Fan OFF Fan ON 7 Condenser Fan #2 Fan Contactor Fan OFF Fan ON 8 Condenser Fan #3 Fan Contactor Fan OFF Fan ON Setpoints The setpoints shown in Table 10 are battery-backed and remembered during power off, are factory set to the Default value, and can be adjusted within the value shown in the Range column. The PW (password) column indicates the password level that must be entered in order to change the setpoint. Passwords are as follows: O = Operator [0100] M = Manager, M level settings are not normally changed for chilled water air-conditioning applications. 24 AGZ 010A through 034A IOMM AGZ1

Table 10, Setpoints Description Default Range PW Unit Unit Enable OFF OFF, ON O COOL Unit Mode COOL COOL w/glycol ICE w/glycol O TEST Control Source SWITCHES SWITCHES, KEYPAD, NETWORK O Available Modes COOL COOL COOL w/glycol COOL/ICE w/glycol M TEST Display Units F/psi F/psi O Language ENGLISH ENGLISH, O Evap LWT (COOL & GLYCOL) 44. 0 F 20.0 to 60.0 F O Ice LWT (ICE) 40. 0 F 20.0 to 40.0 F O Evap Delta T 10. 0 F 6.0 to 16.0 F O Startup Delta T 2.0 F 1.0 to 10.0 F O * Condenser Fans Stages 2 2,3 M * Phase Voltage Protection N N,Y M * SpeedTrol Option N N,Y M Staging Stage Up Delay 120 20 to 240 sec M Stage Down Delay 30 10 to 60 sec M Timers Evap Flow Proof 5 sec 3 to 120 sec M Low Evap Pressure Delay 30 sec 15 sec to 30sec M Start-Start 15 min 10 to 60 min M Stop-Start 5 min 3 to 20 min M Alarms Evaporator Freeze 36.0 F 18 to 42 F M Low Evap Pressure 58 psi 30 to 60 psi M Low Evap Pressure-Hold 59 psi 31 to 65 psi M Low Evap Pressure-Unload 59 psi 31 to 65 psi M High Condenser Stage Down 370 psi 365 to 375 psi M High Condenser Pressure 380 psi 380 to 390 psi M * Low Ambient Lockout 35.0 F 2 to 60 F M Condenser Fans Fan Stages 2 2-3 Stage #1 On 150psi 140 to 200 psi M Stage #2 On 290 psi 230 to 330 psi M Stage #3 On 310 psi 230 to 330 psi M Stage #1 Off Off Off with Stage #1 M Stage #2 Off 170 psi 150 to 200 psi M Stage #3 Off 180 psi 150 to 200 psi M Sensor Offsets Evaporator Refrig Press Sensor Offset 00.0 psi -20.0 to 20.0 psi Condenser Refrig Press Sensor Offset 00.0 psi -20.0 to 20.0 psi Leaving Evaporator Water Temp Sensor 0.0 F -5.0 to 5.0 F Outside Ambient Temperature Sensor 0.0 F -5.0 to 5.0 F (*) These items are factory set prior to shipment. IOMM AGZ1 AGZ 010A through 034A 25

Equipment Protection Alarms Equipment protection alarms execute rapid compressor shutdown. The following table identifies each equipment protection alarm, gives the condition that causes the alarm to occur, and states the action taken because of the alarm. If the alarm is auto-clearing, the reset condition is shown below. Otherwise, the alarm is manually reset, requiring the operator to clear the alarm. Table 11, Shutdown Alarms Description No Evaporator Water Flow Low Evaporator Pressure High Condenser Pressure Motor Protection Phase Voltage Protection (opt) Occurs When: Evap Pump State = RUN and Flow Switch Digital Input = No Flow and time greater than Evap Flow Proof SP Evaporator Press < Low Evap Pressure SP start Low Evap Pressure Time Delay if after Time Delay if Evap Press > SP continue else stop Condenser Press > High Condenser Pressure SP Digital Input = High Motor Temperature On Power Up Delay 150 Sec. before checking If Phase Voltage Protection = Y, Then Digital Input = Phase/Voltage Problem Action Taken Rapid Stop Rapid Stop Rapid Stop Rapid Stop Rapid Stop Reset Flow Switch Closes Manual Manual Manual Phase/Voltage Input Returns to Normal Low Ambient Restart Fault Failed three consecutive low ambient start attempts Rapid Stop Manual Evaporator Freeze Protect Evap LWT < Evaporator Freeze SP Rapid Stop Manual Leaving Evaporator Water Temperature Sensor Fault Sensor shorted or open Rapid Stop Manual Evaporator Pressure Sensor Fault Sensor shorted or open Rapid Stop Manual Condenser Pressure Sensor Fault Sensor shorted or open Rapid Stop Manual Outside Ambient Temperature Sensor Fault Sensor is open or shorted Rapid Stop Manual NOTE: SP=SetPoint Limit Alarms The following alarms limit the operation of the chiller in some way as described in the Action Taken column. These alarms are auto-clearing based on reaching the conditions in the reset column. Table 12, Limit Alarms Description Occurs When: Action Taken Reset Condenser Pressure Stage Down Pressure > High Condenser Stage Down setpoint Shutoff Stage #2 Condenser Press drops below (SP 100psi) Low Ambient Lockout Any compressor is running AND Outside Ambient < Low Amb Lockout SP Shutoff Stages #1 & #2 Outside Ambient > Low Amb Lockout (SP + 5ºF) Low Evaporator Pressure < Low Evap Pressure Hold Hold @ Evap Press rises above Pressure Hold Low Evaporator Pressure Unload NOTE: SP = Set Point setpoint Pressure < Low Evap Pressure Unload setpoint Stage 1 Shutoff Stage 2 (SP + 8psi) Evap Press rises above (SP + 10 psi) Unit Enable Enabling and disabling the chiller is controlled by the Unit Enable Setpoint with options of OFF and ON. This setpoint can be altered by the Unit Off Input, Remote Input, keypad entry, or BAS request. The Control Source setpoint determines which source can change the Unit Enable setpoint with options of SWITCHES, KEYPAD, or NETWORK Changing the Unit Enable Setpoint can be accomplished according to the following table. 26 AGZ 010A through 034A IOMM AGZ1

Table 13, Unit Enable Conditions Unit Off Control Source Input Set Point Remote Input Keypad Entry BAS Request Enable OFF x x x x OFF x SWITCHES OFF x x OFF ON SWITCHES ON x x ON ON KEYPAD X OFF x OFF ON KEYPAD X ON x ON ON NETWORK x x OFF OFF On NETWORK OFF x x OFF ON NETWORK ON x ON ON NOTE: An x indicates that the value is ignored Unit Mode Selection The overall operating mode of the chiller is set by the Unit Mode Setpoint with options of COOL, COOL w/glycol, ICE w/glycol, and TEST. This mode setting can be altered by the keypad, BAS, and Mode input. Changes to the Unit Mode Set Point are controlled by two additional setpoints. Available Modes Setpoint: Determines the operational modes available at any time with options of COOL, COOL w/glycol, COOL/ICE w/glycol, and TEST. Control Source Setpoint: Determines the source that can change the Unit Mode Set Point with options of KEYPAD, NETWORK, or SWITCHES. Changing the Unit Mode Setpoint can be accomplished according to the following table. Table 14, Unit Mode Selection Control Source Mode BAS Available Modes Keypad Entry Set Point Input Request Set Point Unit Mode x x x x COOL COOL x x x x COOL w/glycol COOL w/glycol SWITCHES OFF x x COOL/ICE w/glycol COOL w/glycol SWITCHES ON x x COOL/ICE w/glycol ICE w/glycol KEYPAD x COOL w/glycol x COOL/ICE w/glycol COOL w/glycol KEYPAD x ICE w/glycol x COOL/ICE w/glycol ICE w/glycol NETWORK x x COOL COOL/ICE w/glycol COOL w/glycol NETWORK x x ICE COOL/ICE w/glycol ICE w/glycol x x x x TEST TEST NOTE: An x indicates that the value is ignored. Low Ambient Start If SpeedTrol = N, the unit will start in the normal operation. If the SpeedTrol = Y then starting will follow table below. This step will bypass the Low Evaporator Pressure alarm until Low Ambient Start is completed. Low Ambient Start Method Table 15, Low Ambient Start Sequence Description Occurs When: Action Taken Check #1 After 15 Seconds after starting Lead Compressor, If the Rapid Stop See Low Ambient Evap Press is < 28 take Action or else continue Re-Start below Check #2 After 15 Seconds after Check #1, If the Evap Press is < 38 Rapid Stop See Low Ambient take Action or else continue Re-Start below Check #3 After 15 Seconds after Check #2, If the Evap Press is < 48 Rapid Stop See Low Ambient take Action or else continue Re-Start below Check #4 After 15 Seconds after Check #3, If the Evap Press is < Low Evap Pressure SP take Action or else continue in normal operation Rapid Stop See Low Ambient Re-Start below Low Ambient Restart If the Evap Pressure fails during the low-ambient start, the controller will wait until the anti-cycle timers expire then try to restart. It will allow unit to attempt to start 3 times. If the unit starts successfully, the counter is reset. If it fails to start on the third attempt, the Low Ambient Restart Alarm Fault (Manual Reset) will be activated. IOMM AGZ1 AGZ 010A through 034A 27