SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

Similar documents
SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Air Conditioning. Air conditioning. Overview

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

System architecture. Air treatment Index

HT V2 HT Split

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Modular Air-cooled Chillers

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

H4T R410A. refrigerant

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOG WATER SOURCE HEAT PUMPS

SyScroll Air EVO NEW

KPSW CONSOLE TERMINAL UNIT

Neosys Product catalogue

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

THE CARRIER COMFORT LINE


WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SyScroll 40 to 75 Air NEW

Packaged air conditioners vertical units

Air Cooled Chillers & Heat Pumps WinPACK HE-A

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

High temperature air-to-water heat pumps

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

PRODUCT GUIDE

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

HIWARM COMPACT kw

UniTrane Ductable Units D-line and B-Line

Advance Split

LZT High efficiency air to water heat pumps with E.V.I. compressors

SyScroll 20 to 35 Air NEW

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Blue Box Epsilon Echos +

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

CLIMACIAT AIR COMPACT

Modular Air Cooled Scroll Chillers

Galletti Water chillers and heat pumps catalogue

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TCHE-THHE TCEE

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Vapor-Compression Refrigeration

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

SIMPLICITY FULL MODULARITY?

1

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Transcription:

Air Conditionné Chillers & Heat Centrales Pumps de Water traitement terminals d air Ventilateurs Rooftops Close Sécurité control incendie Water Grilles source et heat Diffusion pumps Composants Direct expansion de réseaux Water cooled SYSEFTYS - SYSHRW Water Source Heat Pumps Range Refrigerant R407C from 2.1 to 30.0 kw from 2.7 to 38.1 kw co m ple m entary range In line with BREEAM requirements! models. VERY HIGH ENERGY EFFICIENCY! (Très Haute Efficacité énergétique) N E W

SYSEFTYS - SYSHRW Water Source Heat Pumps SYSEFTYS 2000-3000 The SYSEFTYS - SYSHRW water source heat pumps range was born from our considerable product experience and our awareness of the market, all combined with a technology based on the energy efficiency of machines, in order to provide a market offer for units with the highest performance in terms of COP and EER. This range has been designed for installation in specifically designed false ceilings or in technical rooms. SYSEFTYS 3 sizes : 2000, 2500 and 3000 (EC motor as standard) 4 versions : Cooling and Heating (RC), cooling only (ST), Cooling and Heating or electrical heating (SH), Cooling and electrical heating (RH) Cooling capacity from 2.1 to 3.0 kw Heating capacity from 2.7 to 3.6 kw com plem entary range In line with BREEAM requirements! models. VERY HIGH ENERGY EFFICIENCY SYSHRW 19-120 SYSHRW 10 sizes : from 19 to 120 4 versions : Cooling and Heating (RC), cooling only (ST), Cooling and Heating or electrical heating (SH), Cooling and electrical heating (RH) 2 models : Standard or (Very High Efficiency) Cooling capacity from 5.3 to 30.0 kw Heating capacity from 5.8 to 38.1 kw EC versions on request! (Très Haute Efficacité énergétique) N E W All of our SYSEFTYS and SYSHRW water source heat pumps equipped with EC fans have this label «Green ventilation». It features all Systemair products with a high energy saving potential. Products labelled with «Green ventilation» combine energy economy with energy efficiency. Advantages High EER/COP With the new models, each size of the SYSHRW range is now in line with BREEAM requirements : - SFP < 750 W/m 3 /s (SFP 2 cat. according to EN13779) - COP > 4,2 - EER > 4,0 Refrigerant charge < 5kg. Low sound levels as standard. Easy access to the compressor, fan and electronic control box, through wide removable panels. L*, U*or in-line air blowing. Condensate drain pan with anti-corrosion treatment. Heat exchanger with brazed stainless steel plates (SYSHRW) / coaxial (SYSEFTYS) for an increased efficiency. Differential pressure switch for antifreeze protection as standard. Bi-Flow thermostatic expansion valve for a wide operating range. Stand-alone regulation by a STORM 2 electronic board which can be configured to 4 operating modes using the RCL user remote control, which comprises a digital display and essential control keys. The μbms mini-supervision station, available as an optional extra, enables 32 units in 15 zones to be monitored and managed with global or individual area programming. * depending on the sizes SYSEFTYS Air filter SYSHRW Fan-motor Fan-motor Coaxial heat exchanger Liquid receiver Finned coil Liquid tank Bi-Flow expansion valve Air filter Cycle reversal valve Finned coil Capillary expansion device Condensate drain pan Cycle reversal valve Electrical box with the STORM 2 electronic board Water/refrigerant plate-type heat exchanger Compressor installed on rubber anti-vibration mounts Condensate drain pan Electrical control box with the STORM 2 electronic board

Quick selection guide SYSEFTYS Cooling and Heating capacities (kw) EER* COP* Nominal air flow (m 3 /h) Dimensions LxWxH (mm) 2000 2.1 2.7 3.88 4.12 451 2500 2.4 3.0 4.13 4.17 503 900 x 530 x 240 3000 3.0 3.6 3.85 4.30 605 SYSHRW Cooling and Heating capacities (kw) EER* COP* Nominal air flow (m 3 /h) Dimensions LxWxH (mm) 19 5.3 5.8 4.00 4.20 1250 900 x 600 x 439 27 7.4 8.3 3.93 3.97 1185 27 7.5 9.3 4.18 4.30 1180 30 8.7 9.8 9,8 3.85 3.78 1490 1050 x 660 x 460 30 8.9 10.0 4.45 4.80 1500 36 10.1 11.0 3.86 3.63 1580 36 11.1 12.2 4.44 4.38 1580 42 11.4 14.4 3.81 4.35 2040 42 12.5 14.5 4.43 5.02 2040 48 13.0 14.9 4.20 4.50 2750 60 14.3 16.1 3.52 3.81 2840 1250 x 705 x 513 60 16.7 18.9 4.96 4.49 2840 1250 x 705 x 583 72 17.2 21.5 3.48 3.59 3570 1250 x 705 x 513 72 20.6 22.6 4.62 4.21 3800 96 21.7 26.6 3.94 3.75 4700 96 24.5 28.5 4.75 4.51 4700 1680 x 955 x 770 120 30.0 38.1 4.18 4.28 5600 * COP and EER Compressor Perfect for offices, hotels, industries and shopping centers Confluence Shopping center McArthurGlen Provence Outlet For a complete solution, think also Lyon, France Miramas, France about our Rooftop units 50 water source heat pumps SYSHRW 160 water source heat pumps SYSHRW HAN SysAer

SYSEFTYS - Technical features SYSEFTYS 2000 2500 3000 Total cooling capacities (1) W 2057 2405 2983 Sensible cooling capacities (1) W 1686 1983 2346 Heating capacities (2) W 2706 2997 3558 COP compressor (2) 4.12 4.17 4.30 EER compressor (1) 3.88 4.13 3.85 COP Total 3.84 3.82 3.85 EER Total 3.65 3.71 3.39 Ventilation Nominal air flow m³/h 451 503 605 Power input - ventilation W 65 66 105 Air filter - Number / Efficiency 1 / G2 Hydraulic circuit Number of heat exchanger 1 Maximum water pressure bar 31 Nominal water flow l/h 419 456 623 Water pressure drop at nominal water flow kpa 11 13 23 Water pressure drop at nominal water flow with valve kpa 27 30 44 Hydraulic connections - Inlet/Outlet inches Male ISO G 1/2 INT Condensate outlet - External Ø mm 16 Refrigerant circuit Number of circuit 1 Compressor type Rotary Electrical data Electrical power supply V / Ph / Hz 230V / 1~ / 50Hz Electric heater power input (3) 1200 1600 2000 Compressor nominal current (4) A 2.8 3.0 4.0 Compressor starting current (5) A 16 16 18.9 Acoustical data (LS/MS/HS) Sound Power - Return + Radiated db(a) 55/57/59 56/58/60 56/58/62 Sound Power - Discharge db(a) 53/55/56 54/56/58 58/61/65 Sound Pressure* db(a) 34/36/38 35/37/40 37/40/44 NR* 30/32/34 31/34/36 34/37/42 Weight Weight - Operating kg 48 48 48 (1) Nominal cooling capacities based on entering air temperature of 27 C dry bulb, 19 C wet bulb with entering water temperature of 30 C. (2) Nominal heating capacities based on entering air temperature of 20 C dry bulb, 15 C wet bulb with entering water temperature of 20 C. (3) Electric heating coil is available for SH & RH versions. (4) Nominal currents are given at +/- 5%. (5) Starting currents are given at +/- 10%. * Informative data, considering an hypothetical sound attenuation of the room and installation of 21 db.

SYSEFTYS - Units Designation and Dimensions FT30. RC. STD AV. 230V/1~/50Hz. R407C. SYSTEMAIR. EC. $. STORM2. RCL. $F. $ + CR. IND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 Description Size Version Configuration Electrical Power Supply Refrigerant Brand Fan type Filter Control FT20 : SYSEFTYS size 2000 FT25 : SYSEFTYS size 2500 ST : Cooling only RH : Cooling and electrical heating STD AV : Standard Aeraulic, frontal hydraulic connections STD LT : Standard Aeraulic, lateral hydraulic connections 230V/1~/50Hz R407C SYSTEMAIR : Systemair EC : EC low energy consumption fan motor STD AV and STD LT configurations $ : Without air filter G2M1 : G2M1 filter STORM2 : STORM2 STORM2+MODBUS : STORM2+MODBUS FT30 : SYSEFTYS size 3000 RC : Cooling and Heating SH : Cooling and Heating or electrical heating MI AV : Mirror Aeraulic, frontal hydraulic connections MI LT : Mirror Aeraulic, lateral hydraulic connections EC-VI : EC low energy consumption fan motor MI AV and MI LT configurations LON : LON AUTRE : Other 10 Remote control $ : Without module μbms : Supervision module RCL : Local control module IR : Infrared module 11 Air return $F : Frontal without plenum RFØ200 : Frontal with plenum + Ø200 nozzle RFØ200 ANØ100 : Frontal with plenum + Ø200 Ø100 nozzles RFØ200 ANØ125 : Frontal with plenum + Ø200 Ø125 nozzles $L : Side without plenum RLØ200 : Side with plenum + Ø200 nozzle RLØ200 ANØ100 : Side with plenum + Ø200 Ø100 nozzles RLØ200 ANØ125 : Side with plenum + Ø200 Ø125 nozzles 12 Air blowing $ : Without plenum SFØ200 : With frontal plenum + Ø200 nozzle SLØ200 : With lateral plenum + Ø200 nozzle 13 Option CR : Quick connection RD : Sum alarm DIS : Circuit breaker SOND : Room sensor 14 Packing IND : Individual INDP : Individual with plenum GR : Bundled GRP : Bundled with plenum External dimensions Hydraulic connections Air duct connection - Return side Air duct connection - Discharge side

com plem entary range In line with BREEAM requirements! models. VERY HIGH ENERGY EFFICIENCY! (Très Haute Efficacité énergétique) N E W SYSHRW - Technical features SYSHRW 19 27 27 30 30 36 36 42 42 48 60 60 72 72 96 96 Total cooling capacities (1) W 5278 7419 7520 8691 8910 10138 11060 11366 12500 12965 14344 16700 17174 20600 21743 24500 29951 Sensible cooling capacities W 4257 5824 5600 6315 6676 7278 9070 8849 9542 10051 10988 13900 13536 17700 17986 19500 24413 Heating capacities (2) W 5826 8342 9252 9759 9960 11036 12200 14422 14450 14904 16147 18800 21500 22600 26637 28500 38109 COP compressor (2) 4.20 3.97 4.30 3.78 4.80 3.63 4.38 4.35 5.02 4.5 3.81 4.49 3.59 4.21 3.75 4.51 4.28 EER compressor (1) 4.00 3.93 4.18 3.85 4.45 3.86 4.44 3.81 4.43 4.2 3.52 4.96 3.48 4.62 3.94 4.75 4.18 COP Total 4.40 3.69 4.21 3.50 4.30 3.38 4.28 3.84 4.36 4.25 3.33 4.20 3.15 4.23 3.54 4.46 4.25 EER Total 4.20 3.72 4.00 3.77 4.15 3.77 4.31 3.44 4.00 4.03 3.23 4.44 3.26 4.74 3.84 4.61 4.21 Ventilation Nominal air flow m³/h 1250 1185 1180 1490 1500 1580 1580 2040 2040 2750 2840 2840 3570 3800 4700 4700 5600 Power input - ventilation W 230 230 230 400 400 418 418 601 601 733 911 911 1350 820 796 796 1360 Air filters - Number / Efficiency 2 / G2 Hydraulic circuit Number of plate heat exchanger 1 Maximum water pressure bar 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 Nominal water flow l/h 921 1540 1620 1764 1800 2030 2306 2592 2600 2822 3348 3550 3924 4300 4860 4960 6408 WPD at nominal water flow kpa 13 17 13 23 20 25 21 33 28 34 40 35 61 50 55 55 80,5 WPD at nominal water flow with valve kpa 16 23 16 33 28 39 30 55 42 60 77 63 112 87 133 130 250 Hydraulic connections - Inlet / Outlet inches ISO G 3/4 INT ISO G ISO G 1 1/4 3/4 INT ISO G 1 1/4 Condensate outlet - External Ø mm 19 22 Refrigerant circuit Number of circuit 1 Compressor type Rotary Scroll Electrical data Electrical power supply 230V / 1~ / 50Hz ±10% 400V / 3~ / 50Hz +Neutre Electric heater power input (3) 2250 3750 3750 3750 3750 4500 4500 5500 5500 6500 7500 7500 9000 9000 13000 13000 16000 Compressor nominal current (4) A 6,6 3.7 3.7 4.5 4.5 5.4 5.4 5.7 5.7 7.0 7.5 7.5 15 15 15.9 15.9 19.6 Compressor starting current (5) A 33.0 32.0 32.0 40.0 40.0 46.0 46.0 51.5 51.5 54.0 65.5 65.5 101 101 111 111 118 Acoustical data (Configuration A) Lw radiated casing only (LS) db(a) 51 54 54 53 53 53 53 54 54 55 55 55 57 55 70 70 72 Lw radiated casing only (MS) db(a) 54 56 56 54 54 56 56 56 56 59 59 59 60 59 69 69 69 Lw radiated casing only (HS) db(a) 58 57 57 57 57 58 58 58 58 63 63 63 63 62 68 68 70 Weight Weight of the unit (approx.) kg 85 100 112 115 115 120 133 133 135 140 144 149 150 253 255 259 280 (1) Nominal cooling capacities based on : entering air temperature of 27 C dry bulb, 19 C wet bulb with entering water temperature of 30 C. (2) Nominal heating capacities based on : entering air temperature of 20 C dry bulb, 15 C wet bulb with entering water temperature of 20 C (3) Electric heating coil is an optional feature available for SH & RH versions. (4) Nominal currents are given at +/- 5%. (5) Starting currents are given at +/- 10%. 120 Configuration A

SYSHRW - Units Designation and Dimensions SYSHRW 27.. ST. 400V/3N~/50Hz. R407C. SYSTEMAIR. SL. $. SECT 1 2 3 4 5 6 7 8 9 Description 1 2 3 4 5 6 7 8 Size Model Version Electrical Power Supply Refrigerant Brand Air blowing Filter SYSHRW 19 : size 19 SYSHRW 27 : size 27 SYSHRW 30 : size 30 SYSHRW 36 : size 36 SYSHRW 42 : size 42 <vide> : Standard : Very High Efficiency ST : Cooling only RH : Cooling and electrical heating 230V/1~/50Hz 400V/3N~/50Hz R407C SYSTEMAIR : Systemair SL : Standard (In-line) SE : Perpendicular (sizes 19 to 60) $ : Without filter G3M1 : G3M1 filter SYSHRW 48 : size 48 SYSHRW 60 : size 60 SYSHRW 72 : size 72 SYSHRW 96 : size 96 SYSHRW 120 : size 120 RC : Cooling and Heating SH : Cooling and Heating or electrical heating SE : Perpendicular (sizes 72 to 120) G2M1 : G2M1 filter 9 Option ALAR : Sum alarm SOND : Room sensor MODBUS : Modbus VAN MOT : Motorised valve SECT : Cut off switch µbms : Supervision module RCL : Local control module SYSHRW 19 to 72 B A C 30 Return air 30 M K 47* J D F D F 30 Perpendicular blowing E G H E In-line air blowing (standard configuration) SYSHRW 72-96- 96-120 1680 955 Return air 770 617 349 349 230 230 Perpendicular blowing A 151 B A In-line air blowing (standard configuration) 419 1196,5 SYSHRW 19 to 72 A B C D E F G H J K M 19 900 600 439 249 249 102 117 160 345 582 280 27-27 - 30-30 - 36 1050 660 460 299 249 109 144 196 365 682 331 36-42 - 42 1250 705 513 299 249 124 165 259 419 882 331 60 1250 705 583 299 349 166 110 215 514 882 331 48-60 - 72 1250 705 513 299 349 166 110 215 419 882 331 * 21 mm for the 60 version SYSHRW 72 to 120 A B 72 317 345 96 317 345 96-120 403 259

Systemair AC SAS Route de Verneuil 27570 Tillières-sur-Avre France Tel +33 02 32 60 61 00 Fax +33 02 32 32 55 13 Systemair srl Via XXV Aprile, 29 20825 Barlassina (MB) Italy Tel +39 0362 680 1 Fax +39 0362 680 693 Systemair AC SAS LEAF SYSEFTYS - SYSHRW-8P-S-1GB(02.17) www.systemair.com www.systemair.com