KHM800 Professional 800w haze machine

Similar documents
Kam StarWash Multicolour wash effects with green & red star cluster laser

QTFX-LF900 Low-Level Fog Machine User Manual

SW-2 SNOW MACHINE. Item ref: UK User Manual

Antari Low Fog Machine

800W DMX smoke machine with HF remote control and Timer USER GUIDE December 2009 Version 1.0

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

Antari X-310 ORDERCODE 60663

QTFX-900 mkii Fog Machine. Item ref: UK User Manual

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Manual. Fazer DFZ-800

Manual. Snow machine S-2

MIC-WKT and MIC-WKT-IR Installation Manual

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual Model: IM03A

Z-350 Fazer Machine User Manual English

HLS-2C Active Hearing Loop Panel

3KW ELECTRIC FAN HEATER

PORTABLE AIR CONDITIONER MODEL NO: AC9000

TAQ ENGLISH / ENGLISH

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

SF Owner s Manual FOG MACHINE. 1

Vivid Fogger Grey ORDERCODE Black ORDERCODE 60655B Orange ORDERCODE 60655O Red ORDERCODE 60655R Blue ORDERCODE 60655U Yellow ORDERCODE 60655Y

Vintage Desk Fan. Model: SF1010 (all colours) Helpline. v1.1

Operating Instructions

SH3020 USER INSTRUCTIONS

100W Powered Subwoofer SUB-80

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

Antari Z-300 ORDERCODE 60661

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Read the entire manual before using this Machine.

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

TAQ ENGLISH / ENGLISH


PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

Whynter Portable Ice Maker 33 lb capacity - White

DMX fog machine User manual

Operating Instructions. Caution: Before attempting to connect or operate this product, please read the label on the bottom. CAUTION: BACK).

Important Notes: Please read carefully before installing your refrigerator.

Portable Air Conditioner USER MANUAL

User Manual. Product Code: TJHC6. T: F: Page 1 of 9 PRODUCT #: TJHC6

USER MANUAL WATER DISPENSER WITH ICE MAKER

5KW ELECTRIC FAN HEATER

Z-Stream Fog Machine User Manual English

LEC L6014W/S User Manual

CS-1600 OWNERS MANUAL

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

CS-1800 OWNERS MANUAL

TAQ-90062KBLUE/PINK. ENGLISH / ENGLISH

POLYMIX PX-IG 2000 Operating Instructions

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

Operation Manual NOVA LIVE S

TAQ-10182MK2. ENGLISH / ENGLISH

ORIGINAL INSTRUCTIONS

2.8KW ELECTRIC FAN HEATER

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

Operating Instructions

SRK-PSE90. Installation Instructions. Stud Rail Kit for PSE90 Manual Wall Bracket. Issue 001

Instructions manual DEHUMID HP50

Read the entire manual before using this Machine.

User Instruction Manual

USER INSTRUCTION MANUAL ACR Alarm Clock Radio Instruction Manual (Read before proceeding)

Aquamax KF Oil Evaporator. User Manual

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

HOT WASHER MODEL NO: KING150

Klipsch Icon Series. Owner's Manual


Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Manual. Hazer DHZ-450

DIESEL/PARAFFIN HEATERS

X T1220 LED FOG MACHINE USER MANUAL

VHF-3005 Dual-Channel VHF Dual Wireless Microphone System

Water Boiler. Instruction manual. Model: GL346-A/GL347-A/GL348-A/GL349-A

Steam Bug. World's smallest steam iron great for travel

RX550i Electric Pressure Washer

Installation & Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

ELECTRIC ASH CAN Model: CVACASH500 Part No:

CHIME & SIREN 2 ICS-8103

FWC153, FWC304, FWC604 & FWC624

Instruction Manual KC93E. Alarm Clock Radio

IMPORTANT SAFETY INSTRUCTIONS

Fog 1550 FT USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

Table of Contents TABLE OF CONTENTS. Cumulus User Manual Rev. 4

DMX fog machine User manual

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

HAZE 500 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

Instruction Manual JLCHDD601/JLCHDD901 60cm/90cm Cooker hood

INSTRUCTIONS MANUAL INDUSTRIAL WALL FAN (20, 26, 30 ) WITH REMOTE CONTROL

PARAFFIN/DIESEL HEATER

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

Transcription:

KHM800 Professional 800w haze machine M A N U A L V E R S I O N 2. 0 0 6-1 1-1 2 Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product from the Kam website at www.kam.co.uk For the latest updates and information on the entire Kam range visit: www.kam.co.uk Kam products are manufactured by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ Telephone: (+44) (0)1582 690600 Fax: (+44) (0)1582 690400 Email: mail@lambaplc.com Web: www.lambaplc.com Due to continuous product development, specifications and appearance are subject to change. Copyright Lamba plc 2012. E&OE. M A D E I N C H I N A

Thank you for purchasing this Kam product, we are sure that it will serve you for many years to come. To optimise the performance of this product, please read these operating instructions carefully to familiarise yourself with the basic operations of this unit. Please retain them for future reference.this unit has been tested at the factory before being shipped to you. To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time. When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To prevent fire hazard, the openings should never be blocked or covered. If the unit is powered by the mains, always handle the power cable by the plug. Never pull out the plug by pulling on the cable. Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an electrical shock. Check the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again. Contact your retailer for a replacement. The voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit. The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons. Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 95ºF / 35ºC). Unpacking and safety Please unpack your new product carefully. Your new product should reach you in perfect condition. Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use the device. Always disconnect the unit from the mains supply when carrying out any cleaning of the unit. Manufacturer declarations In compliance with the following requirements: RoHS Directive (2002/95/EU) and WEEE Directive (2002/96/EU). If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal. CE declaration of conformity R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage Directive (2006/95/EU). The declarations are available on application from certification@lambaplc.com Before putting the devices into operation, please observe the respective country-specific regulations.

Setup: 1. Unpack the haze machine. 2. Open the door on the rear of the machine and slide the fluid tank out of the unit 3. Unscrew the top cap of the tank and remove to fill with the haze fluid. 4. Screw the cap on securely ensuring the pipe is fed down to the bottom of the bottle so a consistent flow of fluid is supplied to the machine Replace the bottle and close the door 5. Connect the remote control. 6. Connect the IEC mains plug and power up. 7. Heat up time is usually 90 seconds. Please ensure no button is pressed during the heat up time. When the machine is ready the LED light on the machine and remote control will illuminate 8. Press the button (3) on the remote control for 5 seconds so the fluid has a chance to flow through the heater block making it ready to use. 9. After this you will be able to use the haze machine. It is recommended to produce haze with small pauses in between so that the temperature is maintained and the thermostat doesn t switch off. Mounting instruction: The fixture may be mounted in any position provided there is adequate room for ventilation and the fluid won t leak. It is important never to obstruct the front of the machine, fan or vents. Mount the fixture using a clamp. Adjust angle of the fixture loosening both knobs and tilting the fixture. After finding desired position, re-tighten both knobs. When selecting installation location, take into consideration refilling the tank and routine maintenance. Safety cables must always be used. Never mount in a place where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Caution! For your safety, please kindly pay attention to all of the warnings listed below: Always plug in the power plug last and disconnect from the mains when the device is not in use or before cleaning. Do not install and operate the device in rain or extreme heat, moisture or dusty environments. This device is for indoor use only Do not switch on immediately but wait until it reaches to room temperature if the device has been exposed to drastic temperature fluctuations. Do not use solvents or aggressive detergents to clean the device. Use a soft and clean cloth. Do not modify the unit in any way Clean the machine regularly using distilled water or smoke/haze cleaning fluid Connect with power supply The ground wire must be connected: Wire Connection International signal Brown Live L Blue Neutral N Yellow / Green Earth Quick Trouble Shooting: If the unit is not functioning properly Check if main power is on and fuse hasn t blown The remote control is plugged in correctly in to the socket Check there is fluid in the tank Check that the pipe is pushed down to the bottom of the tank Check the correct fluid has been used. If there is a block use distilled water or haze machine cleaning fluid. Replacing a fuse: Disconnect from the main power supply first, then remove the fuse holder above the IEC Socket to reveal the fuse. Replace the correct fuse rating as stated in user guide. Then, lock the fuse holder cover back into place.

General maintenance: To maintain optimum performance and minimize wear, the item should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned after use to avoid dust build-up and blockages. Which can result in poor performances, overheating and failure. Disconnect from the mains supply before conducting maintenance. Clean the external case when the fixture is cold with a dry cloth Flushing the unit and internal pipes, this should be done once every 2 months to ensure continuing high performance. use only distilled water or haze machine cleaning fluid, empty the tank, fill with distilled water or haze cleaning fluid and run 2 complete tank fulls through the machine, when complete refil with haze fluid Rear View: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. IEC Power socket Fuse holder Power switch On/Off Back door (Removable fluid tank inside) Remote control socket DMX In DMX Out Ready indicator Dipswitches for DMX address DMX indicator

Timer controller: 1. Timer on/off button 2. Continuous output 3. Manual override button 4. Timer LED indicator (Illuminated Yellow when timer active) 5. Manual ready indicator (Illuminates Green when ready) 6. Power indicator (Illuminates red when power is on) 7. Adjust the amount of Haze released (between 0 100%) NOTE: The below controls are only used when in timer mode 8. Adjust the interval gap between each release of Haze (between 0 30 Min approximately) 9. Adjust the duration the Haze / Haze is released at each interval (between 0 15 seconds approximately) For best results select continuous and adjust output to achieve desired effect, DMX controlling: DMX channel DMX scale Detail function CH 1 000-255 0% - 100% haze input CH 2 000-255 0% - 100% fan speed Dipswitch addressing To set the DMX address please see the example table below. (Note: 1 = On, 0 = Off). DMX Address Dipswitches 1 2 3 4 5 6 7 8 9 1 1 0 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 0 3 1 1 0 0 0 0 0 0 0 It is possible to use the dipswitches to activate the haze machine without a DMX controller Turn dipswitch 10 on. Select switch 1-4 to activate pump. Select switch 5-9 for fan speed (5 = slow, 9 = fast.)

Features Haze output: 1,200 Cu ft/min Relay temperature controlled for constant temperature control and longer life span Uniquely designed nozzle for reduced condensation build up in the pipes True constant haze output Variable output angle Timer output remote control included Easy to transport and portable 2 Channel DMX (output level and fan speed) Removable tank for easy maintenance Technical specifications Power supply: 230V AC, 50Hz Fuse: 5A Power: 800w Heating time: 90 seconds Haze Output: 1,200 Cu Ft per minute Tank capacity: 2.5 Litres Dimensions (WxHxD): 280 x 350 x 295mm Weight: 8Kg