Frequently Asked Questions

Similar documents
Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

ASHRAE JOURNAL ON REHEAT

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Comfort and health-indoor air quality

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Open Cooling Tower. Equipment Layout Guide

Heat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

Packaged Air Conditioning Custom Build Solutions

80-6-ISD A Better Solution for Proper Space Air Distribution

Use this Construction/HVAC Glossary to answer the questions below.

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Dehumidification Systems

Water Intrusion, Vapor Transport and Vapor Diffusion in Buildings. Mark Scott P.E. LEED ap Wiss Janney Elstner Associates

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

- Murdoch University, Western Australia.

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS

CTI Sponsored Educational Program

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

ThermoSaver TM Hot Gas Defrost System

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

Technical Data Ducted Three Phase Split System Air Conditioner

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

GeyserWise MAX. Instruction manual. All in one hot water management

There are (at least) four reasons why you need to understand moisture and humidity in building physics:

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

Heat Recovery Units. Heat Recovery 1

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

How to Take Basic Readings to Show Energy Efficiency

Optimize Evaporative Cooler

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Executive Summary

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Figure 1: Overview of CO 2 evaporator types

Steam System Best Practices Document No. 11

Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award

Highly Efficient,Powerful Heating and Cooling.

WATER HAMMER something that never should occur in a steam system

How to improve air cooler vacuum steam condensers performance in the field

OIL AND GAS INDUSTRY

Refrigeration Systems and Accessories

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

E U R O V E N T CERTIFIED PERFORMANCE

Importance of a Draught Regulator

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

Pressure Enthalpy Charts

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

About Daikin: WARNINGS:

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

Adding More Fan Power Can Be a Good Thing

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Custom Duct Heaters. Special Applications

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

1.1 This section applies to air handling units for HVAC Systems.

Flexible and efficient: Close Climate Control for IT equipment

ThermoSaver TM Hot Gas Defrost System

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

A Waterless Trap from Des Champs Technologies LLC ELIMINATES NEED TO CONSTANTLY MONITOR DRAIN TRAPS FOR DRY OUT AND FREEZING

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

48PGD/E/F/L/M/N PG20-28

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

Effects of Kitchen Ventilation on Residential Dwellings

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

EqUIPMENT LAYOUT MANUAL

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

LQE(E,G,S) Air heater for hot water

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Performance Rating of Active Chilled Beams

Medupi Unit 6 ACC hot cleaning: Method and results

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

KLIMA Active Chilled Beams

PRINCIPLES OF REFRIGERATION ~ CHILLER EFFICIENCY & CONDENSATION by PM Husband

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Transcription:

Frequently Asked Questions Why does the temperature in my office vary so much from its setting? There are a number of reasons that this can occur. Most temperzone controllers have fairly close differentials, and control to plus or minus 0.5 to 1.0 C. However: - 1. Oversized If the unit has been oversized then in the mid-season i.e. spring and autumn when the cooling or heating load is light the unit becomes significantly oversized for the room load. The unit may even swing from heating to cooling cycles and back again during the day. It is probable that the minimum run timer and anti-rapid cycle timer that protect the compressor from short cycling and possible damage are having an influence and keeping the compressor on or off longer than the controller desires. 2. Design Criteria Most cooling design temperatures are based on the design temperature being exceeded at 3.00 pm for approx 10 days a year on average. If the unit is correctly sized, the indoor temperature may rise a degree or two for a few hours on the days when the design temperature is exceeded. It is rare that hot conditions last more than a few days at a time. It does not make sense to oversize a unit for a few days of the year. This is the one reason why units should be selected as close as possible to the estimated cooling load whilst also meeting the heating requirement. Over sizing units is more troublesome than under sizing. Generally undersizing by 5% should not cause too many complaints. This is one reason why units should be selected as close as possible to the room cooling AND/OR heating load. 3. Diffusers Drafts from wrongly placed supply air diffusers could be affecting the temperature sensor built in to the wall plaque, correcting the placement or changing to a return air sensor could solve this issue.

4. Drafts Drafts up the cable duct at the back of the controller surprisingly have been found to be responsible on many occasions for a poorly sensing controller. 5. Stratification Stratification of the air within the room can give a false operation, the room needs good air circulation otherwise the controller does not read the temperature correctly and also the supply air may be short circuiting back to the return air. Why does my Nominal 10 kw unit not seem to deliver the heating when I need it most? Undersized on Heating Air Conditioning units are often selected by contractors to meet the cooling load without considering the heating load. It is strongly recommended by temperzone that the heating load also be considered as sometimes it could be higher than the cooling load which means the unit could be at a disadvantage right from day one. 6. Heating Capacity at Design The heating duty is totally reliant on the outdoor temperature and how much heat it contains. Therefore the heating performance does reduce as the outside temperature falls, though at all times the kw heat pump output is greater than the kw input. As the outside temperature falls then the heat losses through the walls, floor and ceiling increase and so the heating duty requirement increases. The heating load should be at least considered at the lowest ambient temperatures generally expected, not necessarily the one day in the year it is even lower! Residential design temperatures are lower than commercial design temperatures because they cover 24hours.

7. Effect of De-Ice When the outdoor temperature falls below about 4.0 C ice may start to form on the outdoor coil, the higher the moisture content of the air the more ice that may occur and in fact more icing occurs when the outdoor temperature is between zero and 4.0 C than below zero. Heat Pump units have de-icing cycles built in to dispose of the ice but this usually means reversing the cycle for a few minutes during which time there is no heating and in fact a little cooling occurs. This is why at lower outdoor temperatures units have a Gross and Nett heating duties shown, the difference between Gross and Nett being the allowance for de-ice cycles. 8. Night Set Back If the heat pump is switched off at night to save energy, and that of course is a sensible thing to do, then on start up in the morning (or at any time) in heating mode then the room temperature will have fallen, how far being dependant on the outside temperature. To reach the desired temperature requires the unit to raise the existing temperature of the air, structure and furniture (thermal mass) to that level. This is known as a pull up load which is often ignored when units are selected. A temperature controller with night set back would be the answer, this would keep the system in operation but allow the temperature to be maintained a few degrees lower (or higher in summer). Not as energy efficient as turning the system off but allowing the unit to respond faster when needed and some level of comfort is maintained during the set-back period.

In a new building why does it take some days before the Air Conditioning Heat Pump unit seems to work properly? Any new building, especially a commercial building, has a large amount of concrete and other structural materials that are generally cold and full of moisture. This is most evident in the winter when trying to heat the building from scratch. This load can be huge, consider a shopping centre built in mid-winter in the South Island with the inside of the building open to the elements. It may take a week or more when the system starts up to heat up all this material and draw out all the moisture before the space air temperature starts to feel the effect. This also often results in heavy icing of the outdoor coils which cannot be de-iced because there is little or no available heat in the space from which to draw the necessary heat to melt the ice. This can then lead to compressor failure due to liquid slugging during or shortly after the start up/commissioning period. Units need some nursing through this period and should not be left to their own devices. Crushed outdoor coil pipes caused by repeated freezing without a complete de-ice, are another symptom of this. Why is my Unit Spitting or Leaking Water? Water spitting from a unit down the duct or dripping from underneath could be a result of a number of issues, we will list these in the order that they are most likely: - 1. Poor Drain Trapping From past experience nearly 90% of the complaints received about water leaking from a unit or water spitting down the duct are found to be caused by poor/ incorrect trapping or venting of the drain pipe or the drain pipe not sloping correctly. We recommend that the drain trap/vent/slope be investigated first before moving on to other possible issues. Temperzone have a detail drawing of the trap/vent/slope requirements on all unit Installation and Maintenance sheets. Not all units have identical trapping/venting requirements; check the unit installation detail pertinent for your unit.

2. Water Carry-Over This is dependent on many factors: -the face velocity across the indoor coil, the relative humidity of the air, the actual moisture content of the air, the dew point temperature of the air, the surface temperature and associated sensible heat ratio of the coil, the fin spacing of the coil, the number and position of fans, space between them and the ease of fan entry. Therefore it is a very subjective issue, hard to define, and people s expectations vary considerably. At fairly normal return air conditions, say 21.0 to 24.0 C and at 50% RH, and with a nominal room sensible heat ratio of say 0.75 to 0.85 the maximum air velocity across a cooling coil should be 2.5 m/s. This should pretty well insure no water carry over would occur. Exceeding this can be problematic and can vary from unit to unit. However, with the addition of fresh air load the %RH of the air on to the coil will increase and add more moisture load therefore the air flow/velocity should proportionally decrease as the fresh air quantity increases until for a Full Fresh Air system we would recommend the cooling coil face velocity be no more than 2.0 m/s. This should also be considered (along with protection for the compressor) on any units with economisers fitted especially if the fresh air damper is controlled by a CO2 sensor and the compressors could remain operational with high/full fresh air. It is also a good reason why enthalpy/wet bulb control of the economisers free cooling is far superior to simple temperature control. With High Sensible Heat Applications the velocity could be up to 2.8 m/s without water carry over as so little moisture is condensed on the coil. 3. Water Ingress Through Fresh Air Dampers and Weatherhoods temperzone takes great care in designing fresh air dampers and accompanying weatherhoods to try to prevent air velocities at the entries that would manage to entrap falling raindrops passing the entry. However units are often located in situations where localised wind velocities can be extreme, raindrops hitting the ground can bounce back and of course there is no accounting for almost horizontal rain in storms. It becomes an almost impossible task to design something that is 100% weatherproof for every situation. Temperzone will not guarantee 100% weatherproof weatherhoods.

It may be necessary under some circumstances to discard the standard weather hood and replace this with something more suitable for the site and its localised conditions. Another interesting issue that some contractors seem to forget; when the system is being commissioned and the air flow balanced and set, this is usually done with full return air and minimum fresh air. The fresh air damper then needs to be set so that its maximum open position achieves the same air flow quantity as with full return air. Ignoring this step results in the air volume and velocity increasing substantially when the fresh air damper is opened and again is a possible cause for rainwater to become entrained leading to water carry-over. 4. Water Ingress Through Panel Seals Often this is as a result of the system negative static pressure exceeding the design capability of the unit structure. Generally panel seals are designed for approximately 500 Pa to 600 Pa negative pressure. We have had reported incidences of leakage into units where the negative static has been found to be upwards of 800 Pa. Is It True Economisers Can Add Load To A Space? Absolutely. Economisers are intended to use free cooling as an energy saving method for the first stage of cooling before starting compressors. However most economisers are controlled by temperature alone and ignore the moisture content of the air. It sounds good to open the economiser when the air outside is a degree cooler than the inside but it could actually add substantial total heat to the space. As an example, consider a space controlled at 22.0 C db 50%RH; the total heat content is 8.22 g/kg. The outside air is 21.0 C 80%RH (perhaps it is raining), under temperature control the economiser would be open adding outside air to the space with a total heat content of 12.46 g/kg. That is a serious amount of extra load. The best method of control is by enthalpy or wet bulb, that way the total heat content of the outside air must be lower than the inside air before the economiser can open. temperzone ltd December 2009