Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Similar documents
Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

READ AND SAVE THESE INSTRUCTIONS

Easy installation in both new construction and retrofit

Bathroom Exhaust Fan

Easy installation in both new construction and retrofit

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Heater/Exhaust Fan/Light User s Guide

breeze easytm model # F100-1W

Easy installation. T080LP ENERGY STAR Lo Profile Ventilation Fan INSTALLATION GUIDE

HUMIDITY SENSING BATH FAN

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN / LED LIGHT

READ AND SAVE THESE INSTRUCTIONS

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

PLEASE READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Pro Ventilation Hood Liners

Humidity and Thermostat control box for Attic Fan

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

Please Read and Save These Instructions Safety Information

Use, Care, and Installation Guide

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

READ AND SAVE THESE INSTRUCTIONS

Insulated Ventilators. Operating Instructions & Parts Manual

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

High Power Range Hood

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Installation Instructions Exhaust Fan With Light

CONTENTS WIRING DIAGRAM

UNDER CABINET RANGE HOOD

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

Ceiling Fan Installation Instructions

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

INSTALLATION INSTRUCTIONS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

INSTALLATION MANUAL AND USER GUIDE

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Ceiling Fan Installation Instructions

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Use and Care & Installation Guide

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Installation Instructions Remote Blowers

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Cooktop Chimney Ventilation Hoods

Ceiling Fan Installation Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Use, Care, and Installation Guide

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Ceiling Fan Installation Instructions

Installation Electric Dryers Instructions 01

Installation Instructions

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Self-Cleaning Range Hoods

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Ceiling Fan Installation Instructions

Installation Instructions

VENTILATION FAN WITH BLUETOOTH SPEAKER

LONG BEACH 52" outdoor fans

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Transcription:

READ AND SAVE THESE INSTRUCTIONS EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE Easy installation Table of Contents Warnings and Cautions Operation Cleaning and Maintenance Troubleshooting Typical Installation Installation in New Construction Service Parts -7 7 8

Page WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into a ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower (in the ceiling only) when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. CAUTION. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.. DO NOT install this unit onto an acoustic ceiling panel.. When installed in a sloped ceiling, the duct connector must point up.. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 5. Please read specification label on product for further information and requirements. NOT FOR USE IN A COOKING AREA Do not install above or inside this area Operation To Operate Fan Use an ON/OFF switch or speed control to operate this ventilator. WARNING Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Cleaning and Maintenance To Clean For quiet and efficient operation, long life and attractive appearance, remove Grille and vacuum interior of unit with a dusting brush attachment. The Motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the Motor. Troubleshooting Symptom: The fan does not run. Check for an open fuse or circuit breaker in the building s service panel. Check that the plug-in connection for the Motor is seated firmly in place. Check that the Blower Wheel spins freely. Symptom: The fan runs erratically. Check that the Blower Wheel is firmly attached to the Motor shaft and both spin freely. Symptom: The fan seems noisy. Check that the back draft damper in the fan s Duct Connector pivots freely. Screws used to attach the ducting to the Duct Connector may be preventing the damper from opening. Check that the back draft damper in the wall or roof cap pivots freely. These dampers are sometimes mistakenly painted shut or obstructed by bird and insect debris. Typical Installation POWER CABLE* INSULATION* (Place around and over Fan Housing.) FAN HOUSING ROOF CAP* (with built-in damper) Keep duct runs short. Floor 5 5 Cooking Equipment Seal gaps around Housing. *Purchase separately. ROUND DUCT* Seal duct joints with tape. OR ROUND ELBOWS* CEILING INSTALLATION SHOWN WALL CAP* (with built-in damper) The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow. -inch round rigid metal duct is recommended for best performance.

Page Tools needed Phillips screwdriver (recommended) Hammer Safety glasses Pencil Tape Measure Drywall saw Materials needed " round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance. Roof cap or wall cap (built-in damper recommended) Tape to seal duct connections Drywall screws, sheet metal screws (optional) Electrical wiring and supplies per local code requirements Remove from Packaging Punch out Template from packaging. See Step. Prepare the Housing Unplug blower and remove blower from housing. Loosen blower screws. Remove wiring cover.

Page Mark Ceiling Using Template JOIST CENTER LINE OF INSTALLATION For retrofit installations: Place this edge against ceiling framing. (See installation instructions.) Position template over existing fan with arrow on center line. 8¼ MAX. 8 MAX. C L LOCATION OF NEW FAN S DUCT CONNECTOR Make sure existing fan is no larger than 8 x 8¼. ¼ Mark center line of existing fan on ceiling. 0¾ JOIST CENTER LINE OF INSTALLATION For retrofit installations: Place this edge against ceiling framing. (See installation instructions.) LOCATION OF NEW FAN S DUCT CONNECTOR Trace around outside of template with a pencil. C L Cut Ceiling Opening & Remove Old Fan JOIST JOIST Use a drywall saw to cut out ceiling material where marked. WARNING Be careful to avoid cutting through electrical wiring or ductwork. Disconnect electrical wiring and ductwork - then remove existing fan.

Page 5 5 Install New Housing Lift new fan housing up into enlarged rectangle in ceiling material. Hold housing firmly up against ceiling material and carefully tighten clamps with a Phillips screwdriver. When turned clockwise (with a Phillips screwdriver), clamps will spin outward from housing and move downward on top of ceiling material to properly secure housing in place. Minimum ceiling thickness to be /. NOTE: Do not overtighten clamps with a power driver. Ceiling material may become deformed and prevent proper installation. 6 Connect Ductwork Put duct connector into opening and fasten to housing with tab and screw provided. Adjust ductwork into housing and use duct tape to attach it to duct connector. Rigid duct may have to be cut to fit prior to housing installation. For ductwork, use the to reducer (provided). See below. " Ducting É " to " Reducer (provided) Tape É Tape " Duct Connector

Page 6 EZ80N n Installation Guide 7 WARNING Connect Electrical Wiring 9 Install Grille TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: If unfamiliar with electrical wiring, secure the services of a qualified person to connect wiring according to all applicable codes and standards. Connect house wiring to wiring plate with UL approved connector. Connect wiring as shown in diagrams. Attach wiring plate and wiring cover to inside of housing with screws provided. BLK Squeeze grille springs and insert into slots in blower. BLK ON/OFF SWITCH M WHT BLK 0 VAC WHT LINE IN GRD WHT GRD SWITCH BOX BLACK WHITE ON/OFF SWITCH (purchase separately) UNIT GROUND (green or bare) RECEPTACLE SWITCH BOX KNOCKOUT PLATE 0 VAC LINE IN 8 Replace Blower Plug blower into receptacle and re-install blower. Tighten blower screws. Push grille up against ceiling.

Page 7 Installation in New Construction Remove from Packaging (See Page ) Prepare the Housing (See Page ) Install Fan Housing & Connect Ductwork Push duct connector into opening and fasten to housing with tab and screw provided. Position fan against ceiling framing with bottom edge of housing flush with finished ceiling. Use screws to attach housing to framing. Optional for additional support: After ceiling is finished, rotate the tightening clamps as described in Step 5. In new construction (before ceiling is finished): Attach housing to " x 6" or greater ceiling joists. Use additional blocking as needed. JOISTS I-JOISTS TRUSSES ADDITIONAL BLOCKING Use duct tape to connect ductwork to duct connector. For ductwork, use the to reducer (provided). See below. Tape Tape " Ducting É É " to " Reducer (provided) " Duct Connector 5 6 See Connect Electrical Wiring on Page 6. See Replace Blower on Page 6. See Install Grille on Page 6.

Page 8 Service Parts 5 6 7 8 9 Key No. Part No. Description 79058 to Reducer 97096 Wiring Plate 770097 Capacitor 77007 Tightening Clamps (includes screws & clamps) 5 9709006 Wire Cover Assembly 6 770077 Duct Connector Assembly 7 97000 Blower Assembly 8 7900 Grille Spring ( included) 9 970955 Grille Assembly (includes grille springs) Order replacement parts by Part No., not by Key No. Discover a comprehensive collection of RV hardware on our website.