Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Similar documents
Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Principle of Operation:

Toll Free:

Toll Free:

Self-regulating Roof Heat and Gutter Trace Cable

Self-regulating Roof Heat Cable

Toll Free:

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

XL-Trace System Application and Design Guide

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

Drexan Energy Systems Inc.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

NELSON HEAT TRACING SYSTEMS INSTALLATION

INDUSTRIAL HEAT TRACE

Heating cable solutions for temperature-related problems

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

PLSRR Heat Trace Cable Data Sheet

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Design Guide and Installation Details for Self-Regulating Heating Cable

Commercial and Residential Self-Regulating Heating Products

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

Fire Sprinkler Freeze Protection Design / Install Guide

Freezer Frost Heave Prevention

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

SELF-REGULATING PIPE TRACING HEATER CABLE

SERGE BARIL GTKB GUT TRACE KIT BAG

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

FreezGard. Self-regulating crankcase heater. Product Overview

XL-Trace System Installation and Operation Manual

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

CATALOG. Toll Free:

NELSON HEAT TRACING SYSTEMS

F1202 TRACE HEATING. Road & Ramp

Consignes d installation

KE-Series Constant-Wattage Heating Cable

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

First Trace Heating Product Details

RUE Selection Guide and Product Data. RUE Selection Guide

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI)

Roof and Gutter De-Icing

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

CATALOG. Toll Free:

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

HS-TSPLICE - HEATSHRINK TEE / SPLICE. Installation Instructions

NELSON HEAT TRACING SYSTEMS

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Comfort. Description. Applications

Domestic Hot Water Application manual

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Toll Free:

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Flexible Power Cable DLO

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

C Electrical Connection Kit

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

1SC-SSC Splice Connection Kit Installation Instructions

Technical Databook for Industrial Heating Systems

ComfortTile Floor Heating Systems

Cartridge Heaters. Components. Application Guidelines

Installation & Maintenance

Installation, Operation and Maintenance Instructions

Documentation. Parallel Heating Cable. Type: ELP

AKOCABLE Heating Cable Solutions Electrical Tracing

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

NELSON HEAT TRACING SYSTEMS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

AKOCable Heating Cable Solutions Electrical Tracing

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Frost Heave Protection System Installation and Operation Manual

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

H908 WinterGard Plug-in Power Connection Kit with End Seal

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Multi-Use Freeze Protection for Pipes, Tanks and Vessels of All Types and Sizes.

RayClic Connection System

Hot Water Temperature Maintenance Product Selection and Design Guide

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Description. Applications

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Transcription:

Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection D E C B A Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Freeze Protection Applications Cut to Length in Field Can be ingle Overlapped elf Regulating Freeze Protection of Fire Protection ystem Piping Industrial Grade, 16 AWG Buss Wire tandard Braid and Optional Overjacket Circuit Lengths, Up to 660 Ft. 3, 5 and 8 W/Ft., Volt From tock Approximate ize 3/8"W x 1/8"H Minimum Bend Radius 1-1/8" For Use on Metal and Plastic Pipes Description Chromalox RF cable is ideal for keeping metal and plastic pipes warm in commercial construction and institutional buildings, some industrial freeze protection applications. RF cable is constructed of a self-regulating polymer core that varies its output along its entire length, saving energy and eliminating hot spots along the pipe. Parallel construction makes it easier to install than zone or series types of cable since it can be cut-to-length at any point on the pipe. Features Energy efficient, self-regulating RF uses less energy when less heat is required. Easy to install, RF can be cut to any length (up to max. circuit length) in the field. Field splices can be performed easily in minutes with no scrap or wasted cold sections. RF can be overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps. Because RF is self-regulating, over-temperature conditions are minimized. Chromalox termination, splice, tee and end seal kits reduce installation time. Construction A Twin 16 AWG Copper Buss Wires Provide high electrical current capability. B emiconductive Polymer Core Matrix its electrical resistance varies with temperature. As process temperature drops, the core's heat output increases; conversely, as process temperature rises, the heat output decreases. C Polyolefin Jacket Flame retardant, electrically insulates the matrix and buss wires. Also provides resistance to water and some inorganic chemical solutions. D Tinned Copper Braid The braid covering the jacket provides additional mechanical protection in any environment and a positive ground path. E High TPR Overjacket (optional) The TPR overcoat protects the braid and provides resistance to certain inorganic chemical solutions. Approvals UL Listed for ordinary areas. UL Listed for fire protection system piping CA Certified for ordinary areas. WARNING A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping. G-38 Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com

Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF Application & election Guidelines Commercial Freeze Protection RF Cable election Charts These charts are designed to speed selection of the appropriate wattage of cable when used for freeze protection. Find the diameter of pipe below and cross reference with the expected minimum ambient temperature for the recommended cable. elections suitable for and 208 to 277V applications. Design based on straight runs of cable or pipe. piralling is not required. Heat loss is based on 40 F maintenance temperature and Fiberglas insulation k = 0.25 at 50 F. Non-metallic pipe heat losses are based on using Chromalox AT-1 aluminum tape for improving heat transfer. Only 3 W/Ft. rating is UL Listed for nonmetallic pipe applications, however, 5W/Ft. and 8 W/Ft. can be used. Metal Pipe Cable Rating # Runs Plastic Pipe Each block specifies cable rating and # of runs for metal pipe (dark) and plastic pipe (light). For larger pipe sizes, refer to the Technical section in the back of this catalog or contact your Local Chromalox ales office. Note AT-1 Aluminum tape must be used on plastic pipe installation 0.50" Pipe 0.5 0" Pipe 0.5 0" Pipe 0.5 4.00" Pipe 0.5 FREEZE PROTECTION 0" Pipe 5.00" Pipe 0.5 0.5 Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com G-39

Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF Application & election Guidelines (cont d.) 6.00" Pipe 0.5 8.00" Pipe 10.00" Pipe 10" Pipe 14.00" Pipe 16.00" Pipe 18.00" Pipe 20.00" Pipe G-40 Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com

Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection (cont d.) Thermal Ratings on Insulated Metal Pipe 1 14 13 12 11 10 Heat (W/Ft.) 9 8 7 6 5 4 3 2 1 8 W/Ft. Cable vs. 5 W/Ft. 3 W/Ft. 0 10 20 30 40 50 60 70 80 90 100 110 130 140 150 Pipe ( F) Note 1 Thermal output is determined per IEEE 515-2011 tandard for testing, design installation, and maintenance of electrical resistance heat tracing section 4.1.11 Method C. Thermal Ratings on Plastic Pipe with Aluminum Tape Heat (W/Ft.) 9 8 7 6 5 4 3 2 1 Cable vs. 0 10 20 30 40 50 60 70 80 90 100 110 130 140 150 Pipe ( F) Wattage at Alternate Voltages (W/Ft.) Model 208V In 220V In 277V In RF 3 2.4-20 2.6-13 3.4 +15 RF 5 4.1-18 4.5-10 5.6 +13 RF 8 6.88-14 7.28-9 8.96 +12 FREEZE PROTECTION Circuit Breaker election (Max. Circuit Lengths in Ft.) Cable 40 F tart-up (Ft.) 0 F tart-up (Ft.) Rating 20A 30A 40A 20A 30A 40A RF 3-1C 350 360 NR 270 360 NR RF 3-2C 660 NR NR 555 660 NR RF 5-1C 230 270 NR 180 270 NR RF 5-2C 450 540 NR 360 540 NR RF 8-1C 180 215 NR 145 215 NR RF 8-2C 330 420 420 265 395 420 NR = Not Required. Maximum circuit length has been reached in a smaller breaker size. Note Thermal magnetic circuit breakers are recommended since magnetic circuit breakers could "nuisance trip" at low temperature. Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com G-41

Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection (cont d.) Ordering Information (W/Ft.) Volts Model tock PCN at Rated Voltage 3 @ 50 F RF 3-1C RF 3-2C 386943 386951 5 @ 50 F RF 5-1C RF 5-2C 386960 386978 8 @ 50 F RF 8-1C RF 8-2C 386986 386994 With Optional Overcoat (CR) 3 @ 50 F RF 3-1CR RF 3-2CR 386100 386118 5 @ 50 F RF 5-1CR RF 5-2CR 386142 386150 8 @ 50 F RF 8-1CR RF 8-2CR 386062 386070 Wt./1000' (Lbs.) Accessories Accessories U eries DL EL Power Connection Heat trace to electrical service connection UPC RTPC K plice & Tee UMC RTT RT-RT End eal For terminating cable UE RTE RT-RE Thermostat Ambient air sensing thermostat UA RTA THL/TXL Line sensing mechanical thermostat UBC RTBC THR/TXR General Application & Installation Accessories such as tape, pipe straps, warning labels, etc., refer to the U eries and DL & EL General Application Accessories page at the end of this section. Ordering Information To Order Complete the Model Number using the Matrix provided. Model RF elf-regulating Medium elf-regulating, Freeze Protection Code 3 Three 5 Five 8 Eight (W/Ft.) Code Voltage 1 2 Code C Braid and Overcoat Options tandard tinned-copper metallic braid for additional protection and ground path CR TPR overjacket over braid for protection against certain inorganic chemical solutions RF 5 1 C Typical Model Number G-42 Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com