Table of Content

Similar documents
Table of Content LT 5165-UL

Safe Enclosure Cooling

Instruction manual Control cabinet cooling unit CONTROL CABINET COOLING UNIT OC-4540E

Instructions for installation

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

TTV 4500 / TTV 4500 HP / TTV 7000

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

INSTRUCTION AND MAINTENANCE MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

½ Monitored Pneumatic Valves On Series Ported Manifold

235L G. Original-Gebrauchsanleitung V1/1115

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Monitored Pneumatic Valves On Series Ported Manifold

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T15 Model

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

T-Series Air Conditioner T20 Model

Operating Instruction

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

½ Monitored Pneumatic Valve Patented Technology

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTRUCTION MANUAL (English version) Water still

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Mastro GmbH Hüserstraße Hamm / Germany +49 (0)2381/ (0)2381/

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

USER S MANUAL ATH WH220

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Operating Instructions

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

USER MANUAL. Platinum Refrigerator & Freezer Range

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Operating Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

V80-H Multistage Pump Instruction Manual

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Gobi II. English. Condensate Pump Instruction manual Gobi II

Installation and operating instructions. DK energy storage and DK energy buffer

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Instructions for the fan motor control system with integrated wiring terminals SILVER C

USER-MANUAL Tamson Cool Cube Immersion Cooler

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

USER AND MAINTENANCE MANUAL

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KK70 Silent. Installation and Operating Instructions L V001

Contour TM Screw Compressors

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Spare Parts Catalogue AC176

Inverter Swimming Pool Heat Pump

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Installation & Operation Manual

TopTherm Chiller 3318.XXX 3319.XXX 3320.XXX 3334.XXX 3360.XXX. Assembly and operating instructions

CARIBBEAN REFRIGERATED TOPPERS

Transcription:

Table of Content 43402001 1. User manual... 2 2. Legal regulations... 2 3. Safety instructions... 3 4. Technical information... 4 5. Functional principle... 5 6. Technical data... 6 7. Mounting... 7 8. Mounting Principle... 8 9. Dimensions (H x W x D)... 9 10. Electrical connection... 10 11. Wiring diagram... 10 12. Taking into operation... 12 13. Trouble shooting... 12 14. Maintenance & Cleaning... 12 15. Transport & Storage... 13 16. Parts supplied... 13 1 / 13

1. User manual This instruction manual contains information and instructions to enable the user to work safely, correctly and economically on the unit. Understanding and adhering to the manual can help one: Avoid any dangers. Reduce repair costs and stoppages. Extend and improve the reliability and working life of the unit. PLEASE ENSURE TO USE THE RIGHT VERSION OF THE INSTRUCTION MANUAL SUITABLE FOR YOUR UNIT. Conditions of use The unit is to be used exclusively for the dissipation of heat from control cabinets and enclosures in order to protect temperature sensitive components in an industrial environment. To meet the conditions of use, all the information and instructions in the instruction manual must be adhered to. General danger Indicates compulsory safety regulations which are not covered by a specific pictogram such as one of the following. High electric voltage Indicates electric shock danger. Important safety instruction Indicates instructions for safe maintenance and operation of the unit. Attention Indicates possible burns from hot components. Attention Indicates possible damage to the unit. Instruction Indicates possible danger to the environment. 2. Legal regulations Liability The information, data and instructions contained in this instruction manual are current at the time of going to press. We reserve the right to make technical changes to the unit in the course of its development. Therefore, no claims can be accepted for previously delivered units based on the information, diagrams or descriptions contained in this manual. No liability can be accepted for damage and production caused by: 2 / 13

Disregarding the instruction manual Operating error Inappropriate work on or with the unit The use of non-specified spare parts and accessories Unauthorised modifications or changes to the unit by the user or his personnel The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main contractual agreement. Claims for damages on any grounds are excluded. 3. Safety instructions Upon delivery the unit is already meeting current technical standards therefore it can be safely taken into operation. Only trained specialists are allowed to work on the unit. Unauthorised personnel must be prohibited from working on the unit. Operating personnel must inform their superiors immediately if any malfunction of the unit becomes apparent. Please note that before starting to work on or with the unit, a procedure must be carried out inside the cabinet on which the unit is to be mounted. Before commencing work inside the cabinet, the control cabinet manufacturer's instruction must be read with regards to: Safety instructions. Instructions on taking the cabinet out of operation. Instructions on the prevention of unauthorised cabinet reconnection. The electric equipment meets the valid safety regulations. One can find dangerous voltages (above 50 V AC or above 100 V DC) Behind the control cabinet doors. On the power supply in the unit housing. The unit has to be fused according to the type plate and the wiring diagram, and must be protected externally from overloading and electrical faults via suitable protective devices such as ground fault protection breakers. Danger through incorrect work on the unit The unit can only be installed and maintained by technical competent and qualified personnel, using only supplied material according to the supplied instructions. Danger from electrical voltage Only specialised personnel are allowed to maintain and clean the unit. The personnel must ensure that for the duration of the maintenance and cleaning, the unit is disconnected from the electrical supply. Attention Damage to the unit through the use of inappropriate cleaning materials. Please do not use aggressive cleaning material. Instruction Damage to the environment through unauthorised disposal. All spare parts and associated material must be disposed according to the environmental laws. 3 / 13

4. Technical information The cooling unit is intended to be used as a complementary accessory to larger industrial equipment. The unit is used where heat needs to be dissipated from electrical control cabinets or similar enclosures in order to protect heat sensitive components. It is not intended for household use. The unit has two completely separate air circuits which ensure that the clean cabinet air does not come into contact with the ambient air which may well be dirty or polluted. Control cabinet cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclosures into the ambient air and at the same time reduce the cabinet internal temperature to below that of the ambient air. The unit can function without problems in extreme ambient conditions (e.g. dusty and oily air) with a standard operating temperature ranging between +10 C and +55 C. Units can be ordered with an additional electrical cabinet heater. For the cooling capacities and evironmental ratings please refer to the type plate data. Controller The unit is equipped with a temperature controller which regulates the function of the air-conditioning cycle. At normal working conditions the display shows the temperature inside the enclosure. The cooling set point for the interior of the enclosure (parameter St / St1) is pre-set at 35 C and can be adjusted between +20 C and +50 C. To change the cooling set point St/St1: 1. 2. 3. Press Set till St/St1 appears on the display. Press the Up/Down buttons to adjust the temperature setting. Press Set to save the new setting. To change the heating set point St2 (Units with internal heater only): 1. 2. 3. 4. Press Set till St1 appears on the display and release the button. Press again Set till St2 appears on the display. Press the Up/Down buttons to adjust the temperature. Press set to save the new setting. Important Note: when changing settings ensure that: (St2 + 5K) < St1 The unit also has a potential free high temperature alarm relay (normally closed configuration) that is pre-set to switch when the enclosure temperature exceeds 55 C. If necessary the alarm relay configuration and the set point can be changed via the controller s parameters. Kindly contact your nearest service / sales partner for further details on how to change these parameters. 4 / 13

5. Functional principle The cooling unit for enclosures works on the basis of a refrigeration circuit consisting of four main components: compressor (1), evaporator (2), condenser (3) and expansion device (4). The circuit is hermetically sealed and R134a refrigerant circulates inside it (R134a is chlorine free and has an Ozone Destruction Potential [ODP] of 0 and a Global Warning Potential [GWP] of 1430). The compressor compresses the refrigerant (thus taking it to high pressure and high temperature), and pushes it through the condenser, where it is cooled by ambient air thus passing from the gas to the liquid state. At the liquid state it then passes through the capillary pipe being a much lower pressure the refrigerant arrived to the evaporator where it absorbs the necessary heat to change from liquid to gas state. The gas is then drawn back into the compressor completing the cycle. Condensation management In environments with humidity and low internal enclosure temperatures, condensation may form on the evaporator coil. Standard cooling units 43XXX0XXX have a drain socket towards the bottom of the unit for connection of the drain pipe. Cooling units 43XXX1XX include an internal condensate evaporator based on self-regulating PTC cartridges. Condensate is drained to an internal recipient where it evaporates when in contact with the cartridge surface. Resulting steam is directed towards the condenser. The PTC heater cartridge is permanently connected, and condensate evaporator has an approximate evaporation capacity of 250ml/hr. The recipient has an overflow socket at the bottom of the unit. A drain pipe is supplied to connect to overflow socket. 5 / 13

6. Technical data Order Number 43402001 Cooling capacity L35L35 4 kw @ 50 Hz 4 kw @ 60 Hz Cooling capacity L35L50 3.18 kw @ 50 Hz 3.36 kw @ 60 Hz Compressor Rotary piston compressor Refrigerant / GWP R134a / 1430 Refrigerant charge 810 g / 28.6 oz High / low pressure 28 / 6 bar 406 / 88 psig Temperature range +10 C - +55 C Air volume flow (system / unimpeded) Ambient air circuit: 1050 / 1500 m³/h Cabinet air circuit: 860 / 1200 m³/h Mounting External Housing Material Mild steel, powder coated Dimension HxWxD 1,230 x 500 x 340 mm Weight 70 kg Cut out dimensions 1,130 x 430 mm Voltage / Frequency 400/460 V ~ 50/60 Hz 3~ Current L35L35 3.4 A @ 50 Hz 3.5 A @ 60 Hz Starting current 8.5 A Max. current 3.8 A / 4.3 A Nominal power L35L35 1.67 kw @ 50 Hz 2.07 kw @ 60 Hz Max. power 2.16 kw @ 50 Hz 2.67 kw @ 60 Hz Fuse 8 A (T) Connection Connection terminal block Ingress protection External circuit: IP 24 Internal circuit: IP 54 Approvals CE, curus, RoHS 6 / 13

7. Mounting The power supply rating on unit rating plate must comply with mains rating. Always disconnect the power supply before opening the unit. The heat load to be dissipated from enclosure should not exceed specific cooling output of the unit at any condition. At cooling unit selection always cater for a safety margin of at least 15% extra cooling output in the worst conditions. Air inlets and outlets must be completely free from obstruction. Ensure that flows of air leaving and entering the cooling unit, internal and external, are not obstructed. Cooling unit enclosure air suction hole must be installed in the highest possible point. When installing the unit on a door ensure it can take the weight. Before drilling the enclosure ensure the fixing elements and couplings will not interfere with the equipment inside the enclosure itself. Disconnect power before starting any work inside the enclosure. Following this 1:1 Scale Drilling Template drill the holes and make the required cuts on the enclosure. This template may have been affected by storage conditions, please check this template by verifying values of the largest dimensions before drilling. Fit the sealing strip on the cooling unit on the side connected to the enclosure and follow the installation diagram. Note: In case of 19" rack mounted units please ignore the above mounting instructions. 7 / 13

8. Mounting Principle 1 2 3 4 5 6 M6 screws M6 flat washers M6 toothed washers Cabinet Sealing tape Cooling unit 8 / 13

9. Dimensions (H x W x D) 9 / 13

10. Electrical connection Door Switch The unit can be switched on and of via a door contact switch. When delivered the door contact terminals are bridged on the female connector. To connect the door contact switch remove the bridge and connect door contact switch. The contact must be closed when the cabinet door is closed. 11. Wiring diagram C Controller CE Condensate evaporator COMP Compressor SA Surge arrester #1 2nd ambient fan 4340XXX #2 Models with condensate evaporator PSM Phase sequence module AT Autotransformer EB External blower IB Internal blower PC 9 pole connector CC 7 core cable CC2 6 core cable CC3 8 core cable PC2 4 pole connector PC CONNECTIONS 1 L1 2 L2 3 L3 4 Earth 5 400V TR 6 Common 7 460V TR PC2 CONNECTIONS 1 Alarm P1 2 Alarm P2 3 Door contact T1 4 Door contact T2 For 400V supply bridge contacts 5 & 6, for 460V supply bridge contacts 6 & 7. 10 / 13

11 / 13

12. Taking into operation Attention! The unit can be damaged by lack of lubricant. To ensure that the compressor is adequately lubricated the oil, which has been displaced during transport, must be allowed to flow back into it. The unit must therefore be allowed to stand for at least 30 min. before being connected to the mains and taken into operation. Upon connection the internal fan will start working. If the temperature inside the enclosure is higher than the set value of the controller both the compressor and external air fan start working. Once the air inside the enclosure reaches the set temperature the compressor and external fan will stop. The unit is pre-set at 35 C, which is suitable for most of the electronic devices. 13. Trouble shooting Failure Condition Cause Solution Internal fan does not work Power not connected. Verify power supply Internal fan works, external fan Enclosure temperature is below Verify values of parameter and compressor don't work setting temperature (St) "St" Unit doesn't cool Unit doesn't cool Door switch contact is open Verify door switch Controller doesn't work Replace controller Internal fan works, external fan The sequence of the phases and compressor don't work. inside the power supply Display shows alternating OFF connector is incorrect and temperature Change phases inside power supply connector External and internal fan work, compressor does not work Have compressor replaced by qualified service technician Compressor motor electrical failure Capacitor for compressor failed Replace capacitor Compressor works, external fan External fan needs to be doesn't work replaced Replace external fan Compressor and fans (external and internal) work all the time Cooling unit undersized Enclosure needs a cooling unit with with higher capacity Thermal compressor protector triggered Verify if ambient temperature is too high,clean condenser Refrigerant leakage Contact dealer/service center Ambient air gets into the enclosure Ensure door is closed, add a door switch and connect it to controller Enclosure IP protection class is below IP54 Seal all openings of the enclosure Enclosure temperature Compressor and external fan too hot work in alternating mode (ON / OFF) Enclosure door open Excessive condensate Enclosure door closed Damaged or misplaced sealing Repair sealing strip strip accordingly 14. Maintenance & Cleaning Always switch power supply off before starting any maintenance on the unit. The cooling unit is generally maintenance free and can be operated without filters in most environments. For units with filters these should be checked, cleaned and if necessary replaced on a regular basis. In addition the unit should have regular functional tests (approx. every 2,000 hours depending on the grade of ambient pollution). Disposal The unit contains R134a refrigerant and small quantities of lubricating oil. Replacement, repairs and 12 / 13

final disposal must be done according to the regulations of each country for these substances. 15. Transport & Storage Malfunction due to transport damage On delivery the carton box containing the unit must be examined for signs of transport damage. Any transport damage to the carton box could indicate that the unit itself has been damaged in transit which in the worst case could mean that the unit will not function. The unit can only be stored in locations which meet the following conditions: temperature range: - 40 C to + 70 C Relative humidity (at 25 C): max. 95 % Returning the unit To avoid transport damage the unit should be returned in the original packing or in a packing case and must be strapped to a pallet. If the unit cannot be returned in the original packing please ensure that: A space of at least 30 mm. must be maintained at all points between the unit and the external packing. The unit must be shipped in the same position as it was mounted. The unit must be protected by shock resistant padding (hard foam corner pieces, strips or cardboard corner pieces). 16. Parts supplied 1 x Cooling unit with individual packaging 1 x Plastic bag containing: 1 x Instruction manual with techn. information 1 x CE declaration of conformity 1 x Drilling template in 1:1 scale 8 x M6 bolts 8 x washers 8 x locking washers 1 x 10 x 3 mm self-adhensive sealing strip 1 x Flexible drain pipe 1 x Female connector with bridged door contact Seifert Systems GmbH Haßlinghauser Str. 156 Seifert Systems Ltd. HF09/10 Hal-Far Industrial Estate 58285 Gevelsberg Birzebbuga, BBG 3000 Germany Malta Tel. +49 (0) 2332 55124-0 Tel. +356 2220 7000 Fax +49 (0) 2332 5512429 Fax +356 2165 2009 info.de@seifertsystems.com info@seifertsystems.com Seifert Systems AG Wilerstrasse 16 Seifert Systems Inc. 75 Circuit Drive North Kingstown 4563 Gerlafingen RI 0285 Switzerland USA Tel. +41 (0) 32 675 35 51 Tel. +1 401-294-6960 Fax +41 (0) 32 675 44 76 Fax +1 401-294-6963 info.ch@seifertsystems.com info.us@seifertsystems.com Seifert Systems Pty Ltd. 105 Lewis Road Wantirna South 3152 Victoria Australia Tel. +61 (3) 98 01 19 06 Fax. +61 (3) 98 87 08 45 info@seifertsystems.com.au 13 / 13