MT300 Series Dehydrators

Similar documents
ID SERIES CABLE DRYER USER MANUAL. Bulletin AE01B-A Date: 6 FEB 07

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

MODEL MW200 MODEL MW600 AIR DRYER

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units)

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

PARAGON Commercial Refrigeration Controls

SERVICE MANUAL FOR MODEL RM-10

SERVICE MANUAL FOR MODEL RM-49

Hoshizaki America, Inc.

SAHARA SERIES DryLine DEHYDRATOR USER MANUAL

SERVICE MANUAL FOR MODEL RM-26

SAHARA2A-HP SERIES DryLine DEHYDRATOR USER MANUAL

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

Installation Instructions

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

2 PREPARE THE OPENING

2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections, before turning on power

Rev B, 9/2/2009. Kodiak Chiller Overview

CU0415, CU0715 and CU0920 Service Parts

REF5-BB Undercounter Blood Bank Refrigerator

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Installation Instructions 30 French Door Built-in Wall Ovens

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Installation Instructions

Installation Instructions

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

Air Heater. Air Top 3500 Diesel. Supplemental Installation Instructions for: Van Body Vehicles

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com

Helpful Tip: NOTE:

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.

R11C R12C R21C R22C/H R23C/H R24C/H

-30 C Undercounter Plasma Freezer

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

2 Wire Nuts (or other approved wire connectors) (Field-supplied) Push Button(s) Phillips Head Screwdriver (Field-supplied) Control-R Module

WM3000 WIRELESS MODULES

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

REF Series Undercounter Refrigerator

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

MODELS SSB-3E/5E/10EF, (2)SSB-3E/5E/10EF, SSB-3G/5G/10GF, (2)SSB-3G/5G/10GF

Reach-In Refrigerators and Freezers Service Manual

P4200PM / P5000PM Remote Air Dryer User s Guide

SKR series Steam Humidifier with SDU module (Patent Pending)

Dometic Manual Refrigerators

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

INSTALLER S & OWNER S MANUAL

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

HR150 SERIES DEHYDRATOR USER MANUAL

ELECTRONIC COMMUNICATING THERMOSTAT

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

Installation Instructions Wall Ovens

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

ARM SERIES Switching Relays With Priority

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Model R11C. Replacement for: Westinghouse "RB" Series Chassis R21C. Replacement for: Climate Master (Friedrich) 701 Series R23C R23H.

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

REF Series Undercounter Refrigerator

Wiring Diagrams DIAGRAM INDEX

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Dual Column Dehydrating Breather Manual

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Installation Instructions

Service Manual. Model Number: DFR2651L. UL Part Number

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

Installation, Operating, and Maintenance Manual

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

BUNN TECHNICAL TRAINING ICB

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

CytoTherm. 110 Sewell Ave. Trenton NJ USA Tel or Fax Web

T-Series Air Conditioner T15 Model

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Parts and Service Manual

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA

REPLACEMENT PARTS MANUAL

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Transcription:

INSTALLATION ADDENDUM MT00 Series Dehydrators.0 Introduction Page Installation Recent design improvements have been introduced on the MT00 Series Dehydrator that are not detailed in the printed manual. The following addendum lists the changes that apply to the unit you have received. Page Dehydrator Control, Indicators and Connectors. Rack Mounted unscrew the four rubber feet from the bottom of the dehydrator and replace with the four / x 0 PPH machine screws from the cloth bag attached to the dehydrator. Wall Mounted A template drawing (AE0B-D0-00) is provided to help in locating the positions for drilling holes in the wall. Page Installation The ac power cords are no longer "hard wired" to the dehydrator chassis. Now they plug into an IEC receptacle on the chassis and they are secured with a clamping metal strain relief. Page Installation NOTE: An alarm terminal strip and label have been added to the MT00 chassis (front view) and the low pressure alarm cable has been deleted (rear view). Customer connections for the low pressure alarm on an MT00 Dehydrator are made at a terminal block located at the front of the chassis. A label in front of the strip identifies the alarm terminal strip functions.

7 8 9 7 8 9 0 0 GRN GRY YEL PUR TB-0 TB-9 TB-8 TB-7 TB- TB- TB- TB- TB- TB- MT00 SERIES DEHYDRATOR ADDENDUM Page 9 Schematic Diagrams Wiring for the new version MT00 is shown below. There are wire color, wire routing and component changes. MT00-XX0XX NO NC C or 0 0 9 9 8 8 7 7 GRY LOW PRESSURE ALARM SWITCH N G L ON/OFF SWITCH S L L M M FAN 0 SEC TIMER GRN CHASSIS MT00-XXXX NC NO C LOW PRESSURE ALARM SWITCH GRY -ALARM BOARD GRN/YEL OR POWER RELAY PR M HOUR METER IEC CONNECTOR G L N HUMIDITY SENSOR ELEMENT ON/OFF SWITCH S PRESS SWITCH L M L M PS QMS B FAN 0 SEC TIMER GRN CHASSIS E

MT00 SERIES DEHYDRATOR ADDENDUM Compressor 7. MFD 7. MFD GRN/YEL GRN/YEL VAC./COMP. MOTOR 0 VAC CONNECTION DIAGRAM CAPACITOR C INCLUDED WITH MOTOR VAC./COMP. MOTOR 0 VAC CONNECTION DIAGRAM CAPACITOR C INCLUDED WITH MOTOR VAC (-XXXX) 0 VAC (-XXXX) Triple Alarm Option: This optional assembly is designed to provide the additional Excess Run, High Humidity and Power Fail alarms to Andrew Dehydrators. All alarms are Form C dry contacts and are factory set for continuity at alarm. The external alarm monitoring system (not included) is connected to the terminal strip located at the top of the chassis. A small slotted screwdriver is necessary to make the connections. The connections to the alarm strip are as follows, and refer to Figure for correct locations and colors of the wires on the terminal strip.

MT00 SERIES DEHYDRATOR ADDENDUM Alarm Definitions: Excess Run: User settable run time to be set in accordance with the normal run time for the particular application. Selectable times are 0, 0, 0 and 0 minutes. See Figure for location of JP. Power Fail: Activates when power is removed from the dehydrator. This includes turning the power off at the switch. High Humidity: Activates when system or dehydrator output humidity rise above 7.% relative humidity. At initial installation, this alarm will continue to alarm until the system has been properly purged. Changing Alarm Outputs: The alarm outputs are factory set to prouide continuity on alarm. To change the Low Pressure alarm to NO, switch the push-on terminals on the alarm switch (center terminal is NO, bottom terminal is NC). Jumpers are provided on the triple alarm board for changing the contacts on the alarm relays. Terminal JP is for mains power fail alarm, JP is for the excess run time alarm, and JP is for the humidity alarm. See Figure for jumper locations. Both terminals are marked for the NC and NO options. Checking Alarm Operation: Checking correct alarm operation can be verified the most efficiently by using a continuity meter at the terminals of the alarm strip located on the front side of the unit. All contacts are form C dry contacts and will indicate an open or closed condition based on the jumpers set in the previous section. All contacts are preset at the factory for continuity on alarm. Humidity Alarm: At first power up, check the humidity alarm, because as the unit runs into the system or open air, the humidity alarm will clear, and the unit will have to sit idle in ambient air for a period of time in order for the humidity level in the internal parts to rise above the trigger point. Power Fail: Power fail is verified by alternating the power switch on the front of the unit from the ON to the OFF position and vice versa. Excess Run: The alarm timer is preset at the factory to 0 min, and this check will take the most time. It is recommended to check the excess run alarm during the initial run to purge the system.

MT00 SERIES DEHYDRATOR ADDENDUM Replacement Parts (Back Page) The complement of replacement parts has changed for the new MT00. Use the following list to identify and order replacement parts. DESCRIPTION TYPE NUMBER DESCRIPTION TYPE NUMBER Compressor AE0J-A9-00 Kit AE0K-D08-00 Power Switch (S) Vac AE0J-A09-00 0 Vac AE0J-A09-00 Circuit Breaker (CB) EBREK-7 Triple Alarm Circuit Board AE0J-B08-00 Fuse (Triple Alarm Board) AE0J-A9-00 Power Relay (PR) Vac ERLYP- 0 Vac ERLYP-8 Pressure Switch (PS) ESWPR-00 Pressure Switch (PS) AE0J-A07-00 Time Delay Module, 0 sec. (QMS) Vac ETMDM-00 0 Vac ETMDM-00 Dehydrator Overhaul Kit AE0K-C098-0 Coalescing Filter EFLTA-00 (complete assembly) Coalescing Filter Bowl EFLTA-8000 Coalescing Filter Element EFLTA-900 Water Filter, complete assembly EFLTA-00 Water Filter Bowl EFLTA-900 Water Filter Element EFLTA-900 Air Intake Filters, bag of AE0K-B08-00 Air Intake Filter EFLTR-00 (complete cartridge assembly) Back Pressure Regulator EVLVR-000 Evaporator Pan AE0A-C089 Evaporator Pan Tube Fitting EFTGS-0 Cooling Fan (sound deadened unit) Vac AE0J-A09-00 0 Vac EFANS-0 /" Tubing, clear, specify feet ETUBE-00 /" Tubing, black, specify feet - /8" Tubing, black, specify feet AE0K-D080-0 Pressure Gauge EGAUG-00 Compressor Isolators AE0J-A098-0 Power Cable Vac, UL/CSA Plug AE0J-A078-00 0 Vac, bare leads AE0J-A078-00 Power Cable Strain Relief (clamping) Vac AE0J-A078-0 0 Vac AE0J-A078-00 Heat Exchanger AE0M-D0-00 High Temperature Hose EHOSE-00 (compressor to heat exchanger, specify / foot) Low Temperature Hose EHOSE-00 (heat exchanger to water filter, specify foot) Hose Clamp ECLMP-0090 (High and Low Temperature hoses) Front Door Fasteners, bag of AE0K-D088-00 Rubber Feet, bag of AE0K-D088-00 / x 0 Machine Screws, bag of AE0K-D088-00

MT00 SERIES DEHYDRATOR ADDENDUM Andrew Corporation 000 West rd Street Orland Park, IL U.S.A. 0 www.andrew.com Telephone: 708/9-00 FAX (U.S.A.): -800-9- Customer Service, hours: North America: -800--79 U.K.: 0800 00 Europe, Africa & Middle East: + 9 78 AE0B-A0-00 Rev: B