Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Similar documents
Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Duct Cable GYTS-144B1.3

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Ø 1000 * 588 mm 50 kg

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

HELKAMA. Optical Fibre Cables

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

Fibre Specification Standards

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

DNVGL-CP-0402 Edition February 2016

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

SPECIAL ELECTRICAL AND OPTICAL CABLES

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Flame Retardant Overall Screened Instrumentation Cables (multicore)

High Performance LSZH Fire Resistant Cable

Fibre Optic Cable. Catalogue.

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fiber Optic Patch Cord and Pigtails

Fiber Optic Distribution Cables (6-144 Fibers)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Special Provision No. 683S28 December 2017

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Caledonian Flame Retardant Coaxial Cables

Traction Cable Radox 3 GKW

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This document is a preview generated by EVS

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Introduction.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Catalogue Telecommunication Cables INTRODUCCIÓN

PRODUCT CATALOGUE Norröna

Fibre optic media options and trends

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

fire resistant cables

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FIRE RESISTANT CABLES FP400

The Quality Connection. BETAflam Fire Resistant Safety Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

industry solutions: military

Photovoltaic Cables EN H1Z2Z2-K

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

FIRE RESISTANT CABLES FP300

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

ENHANCED FIRE PERFORMANCE CABLE

Lloyd s Register Type Approval System Test Specification Number 3

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

FIRE RESISTANT CABLES

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Cable technology for highest safety requirements

LSOH Flexible Cables

FIRE PERFORMANCE CABLE

Fire Resistant Cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Telecommunication Cables

DNVGL-CP-0401 Edition February 2016

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

INTERNATIONAL STANDARD

Single core cables with reduced wall thickness

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

DNVGL-CP-0399 Edition March 2016

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

WG Buried Fibre Cable Long Perimeter Detection System

STANDARDS INSTALLATION. Certificate No 077m

Havells Fire Survival Cables

BS /1000V XLPE Insulation LSZH Sheath Cables

Catalogue Power Cables

INTERNATIONAL STANDARD

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Total Fire Solutions. Includes BS 8519 and the updated BS :

STANDARD CONFORMANCE

FIRST-CLASS IN TRAINS

Transcription:

OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST 1X24E9/125 Application and installation The application of this cable is circumstances where a very high degree of fire safety is required as the cable will function during a fire, has limited fire spread, has limited smoke generation and is halogen free. The typical installation environment is indoor and indoor/outdoor in and between public buildings, in tunnels, metro lines and other places where one need very high degree of fire safety and support for critical communication. This cable is also suitable for shipboard application. The steel tape armouring makes the cable rodent proof. The primary means of installation are on cable ladders, raceways and cable trays. The cable may however also be directly buried. The cable may also be installed outdoor in the open, as the cable sheath is UV stabilised. However we do recommend the cable to be covered in order avoid tampering. The UV stabilisation of the cable sheath insure more than 15 years of safe operation in the open when installed in Northern Europe or the UK. Standards ISO 11801, EN 50173, IEC 60794-1, IEC 60794-2- Fire rating Fire resistance tests IEC 60331-25 (120) Fire resistance: 120 minutes at 750 C (No fibre break) EN 50200 PH 120 Fire resistance with fire and impact 120 minutes 830 C (No fibre break) EN 50200 ANNEX E PH 30 Fire resistance until 15 minutes of fire and impact alone, followed by 15 minutes of fire, impact and water spray at 830 C (No fibre break) BS 8434-2 Fire resistance until 60 minutes of fire and impact alone, followed by 60 minutes of fire, impact and water spray at 930 C (No fibre break) Flame retardant tests IEC 60332-1-2 Single vertical wire test Flame propagation test IEC 60332-3-24 = Vertically-mounted bunched wires and cables IEC 332-3C Halogen acid & gas tests IEC 60754-1 No halogens IEC 60754-2 No acid matters Smoke emission tests Page 1 of 3

OFC-UT-CST Fire resistant Armoured IEC 61034-2 No dense smoke Construction Loose tube Ø4.0 mm jelly filled loose tube green colored with up to 2-24 fibres Fibre colour code 1 Red 13 Yellow w/mark per 100 mm 2 Green 14 White w/mark per 100 mm 3 Blue 15 Grey w/mark per 100 mm 4 Yellow 16 Turquoise w/mark per 100 mm 5 White 17 Orange w/mark per 100 mm 6 Grey 18 Pink w/mark per 100 mm 7 Brown 19 Yellow w/mark every 50 mm 8 Violet 20 White w/mark every 50 mm 9 Turquoise 21 Grey w/mark every 50 mm 10 Black 22 Turquoise w/mark every 50 mm 11 Orange 23 Orange w/mark every 50 mm 12 Pink 24 Pink w/mark every 50 mm Fire barrier Tape(s) Strength member Water blocked E-Glass fibre elements Ripcord 1 Inner sheath 2.5 mm red LSHF-FR sheath according to EN 50290-2-27, UV stabilised Armouring Coated and corrosion protected corrugated steel tape (CST), thickness 0.15 mm Ripcord 1 Outer sheath 1.4 mm red LSHF-FR sheath according to EN 50290-2-27, UV stabilised Print legend Draka Firetuf by Prysmian Group FO I/O CT CST LSHF-FR 2.0 kn <Fibre count> <Fibre type><fibre brand><item No>22<Batch Number<Meter mark> Physical properties Property Test method Value Nominal outer diameter - 17 mm Nominal weight - 351 kg/km Maximum installation tensile strength E1 3500 N (Δl/l fibre 0.5%, Δ reversible) * IEC 60794-1 Compressive strength (crush) E3 5000 N / 100 mm, max 5 min (Δ reversible ) * Impact E7 50 Nm, No fibre break, 3 impacts, r=300mm, Torsion E7 5 cycles 1 turn Kink E10 The cables do not form a kink when a loop is drawn together to a diameter of 20xD (Cable diameter) mm Min. bending radius, unloaded E11 R = 255 mm Min. bending radius, loaded - R = 340 mm Temperature range F1 Storage: -40 C to +80 C Installation: 0 C to +50 C Operation: -40 C to +70 C. (Δ 0.05 db /km)** Water penetration F5B No water leakage after 24 hour, sample=3m, water=1m, * Values for single-mode fibres, all optical measurements performed at 1550 nm, ** Values for multi-mode fibres, all optical measurements performed at 850 nm or 1300 nm with 0.10 db as threshold (tensile and crush will not be performed for MM fibres) Page 2 of 3

OFC-UT-CST Fire resistant Armoured Product codes ordering information Prysmian group material code Prysmian Group material description Draka Material code Fibre count Fibre type Fibre data sheet Delivery form: Wooden drum with protection. Standard delivery length: 4 km with a tolerance of -+ 5%. PRYSMIAN GROUP 2011, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group. Page 3 of 3

C03 Properties of cable with standard Enhanced SM fibre ESMF, low water peak single mode fibre G652D, OS2 General and application The optical fibres are made of a high grade doped silica core surrounded by a silica cladding. They are coated with a dual layer, UV cured acrylate based coating. This enhanced single mode fibre provides improved performance across the entire 1260 nm to 1625 nm wavelength spectrum due to its low attenuation in 1383 nm, the water-peak region. Standards and Norms IEC / EN 60793-2-50 Category B.1.3 ITU-T Recommendation G.652.D and C, B, A IEEE 802.3 2002 incl. 802.3ae EN 50 173-1:2007, cat. OS2 and OS1 ISO / IEC 11801:2002, cat. OS2 and OS1 ISO / IEC 24702: 2006, cat. OS2 and OS1 Optical properties Mode field diameter at 1310 nm µm 9.0 ± 0.4 IEC/EN 60793-1-45 Mode field diameter at 1550 nm µm 10.1 ± 0.5 Chromatic dispersion coefficient: IEC/EN 60793-1-42 In the interval 1285 nm 1330 nm ps/km nm 3 At 1550 nm ps/km nm 18.0 At 1625 nm ps/km nm 22.0 Zero dispersion wavelength, λ 0 nm 1300-1322 Zero dispersion slope ps/(nm 2 km) 0.090 Cut-off wavelength IEC/EN 60793-1-44 λ cc nm 1260 * Polarisation mode dispersion (PMD) coefficient IEC/EN 60793-1-48 ps/ km 0.5 PMD Q Link Design Value (computed with Q=0.01%, N=20) IEC/EN 60794-3 ps/ km 0.2 * guaranteed value according to the ITU-T (ATM G650) method Attenuation Maximum attenuation value of cable in the interval 1310 nm 1625 nm IEC/EN 60793-1-40 db/km 0.39 Maximum attenuation value of cable at 1550 nm IEC/EN 60793-1-40 db/km 0.25 Local discontinuity at 1310 and 1550 nm IEC/EN 60793-1-40 db Max. 0.1 Attenuation variation vs Bending 100 turns on a R=25 mm mandrel at 1310 & 1550 nm IEC/EN 60793-1-47 db 0.05 100 turns on a R=30 mm mandrel at 1625 nm IEC/EN 60793-1-47 db 0.05 C03_en / Version 11.1 Issued 2012-04-06 / Page 1 of 2

C03 Group index of refraction Attribute Measurement method Units Values 1310 nm IEC/EN 60793-1-22-1.467 1550 nm IEC/EN 60793-1-22-1.468 1625 nm IEC/EN 60793-1-22-1.468 Geometrical properties Cladding diameter IEC/EN 60793-1-20 µm 125.0 ± 0.7 Cladding non-circularity IEC/EN 60793-1-20 % 0.7 Core (MDF) -cladding concentricity error IEC/EN 60793-1-20 µm 0.5 Primary coating diameter ColorLock XS and natural IEC/EN 60793-1-21 µm 242 ± 7 Primary coating non-circularity IEC/EN 60793-1-21 % 5 Primary coating-cladding concentricity error IEC/EN 60793-1-21 µm 12 Mechanical properties Proof stress level IEC/EN 60793-1-30 GPa 0.7 ( 1 %) Strip force (peak) IEC/EN 60793-1-32 N 1.2 F peak.strip 8.9 Dynamic fatigue resistance aged and unaged IEC / EN 60793-1-33 (N d ) 20 Static fatigue, aged IEC / EN 60793-1-33 (N s ) 23 All measurements in accordance with ITU-T G650 recommendations PrysmianGroup 2012, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by PrysmianGroup: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of PrysmianGroup. The information is believed to be correct at the time of issue. PrysmianGroup reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by PrysmianGroup. C03_en / Version 11.1 Issued 2012-04-06 / Page 2 of 2