Ultrasonic Level Measurement nivopuls FDU 10 S

Similar documents
Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Micro/Ultra Filtration System StamoClean CAT 430

Micro/Ultra Filtration System StamoClean CAT 430

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Liquiphant T FTL20H. Technical Information

Liquiphant S, Nivotester FDL60/61, FTL670

Vibracon LVL-A* Level limit switch for liquids, compact design

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Technical Data. Dimensions

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

PEPPERL+FUCHS GmbH

SET-2000 Oil/Sludge 12 VDC

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rinse connection adapter CPR 40

Gas cylinder scale Model GCS-1

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Technical Data. Dimensions

Rosemount 3100 Series Ultrasonic Level Transmitters

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Rotameter series 250 metal tube variable area flowmeter

Technical Information OUSTF10

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

OPTIBAR DP 7060 Supplementary Instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Instruction Manual September 2010 SITRANS LVL200S

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Inductive slot sensor

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

IECEx Certificate of Conformity

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Technical Data. General specifications. Rated operating distance s n 5 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET-1000 (12 VDC)

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

Rosemount 3100 Series Ultrasonic Level Transmitters

Soliphant M with electronic insert FEM52

Temperature Measurement Transmitters for field mounting

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Prosonic S FDU91/91F/92/93/95/96

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Safety instrumented systems

Model 144H. Product Data Sheet , Rev DB February Content

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Instruction Manual September 2010 SITRANS LVL200S

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Technical Data. Dimensions

Level Measurement Continuous level measurement Ultrasonic transmitters

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Process Alarm Module RTA 421

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Engineering Guideline. pac- Carriers Type Universal

OPTIBAR P 1010/2010 C Supplementary instructions

Manual Isolating Barrier D461R1 (Revision 01)

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Assembly. Host Sub-D Alarm

AO Annunciator Module

DICTATOR Hold-Open Systems for Hazardous Areas

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Software Version 2.01 LEVEL MONITOR MODEL 220

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

MANUAL Oil Level Sensor

SET Installation and Operating Instructions. Level switch for one sensor

Indoor/outdoor resistance thermometer Model TR60

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

FAHM Co. Temperature Transmitter PTT74 Series

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

SET-2000 Hi Level/Oil

U5300 Industrial Pressure Transducer

Magnetostrictive sensor For bypass level indicators Model BLM

Proservo NMS5- / NMS7-

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

Dräger Polytron 7000 Fixed gas detector

Thermal Management Products & Accessories for Enclosures

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

Level gauges Series LS Level indicator, switch and transmitter for liquids

DB5 Intrinsically Safe Sounder Type DB-5

UV Flame Supervision System

for relative humidity and temperature

Transcription:

Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous areas Nivopuls FDU 10 S Application The Nivopuls FDU 10 S is a level limit switch for thin liquids, suspensions and emulsions, which is attached externally to the vessel wall and has a separate electronics unit. It is not suitable for liquids which tend to build-up and applications in which a gas film adheres to the inside wall. Gas bubbles within the liquid have no effect on measurement. The measurement method is suitable for metal, enamelled, glass and plastic vessels, not, however, vessels made of PVDF or PTFE, with double walls or with plastic linings. Features and Benefits Limit detection through the vessel wall: simple installation no process connection measurement independent of process pressure No contact with the product: no corrosion suitable for sanitary applications, e.g. foodstuffs and pharmaceuticals For thin liquids: viscosity up to 100 mm 2 /s (cst), temperature up to 100 C Separate electronics unit for mounting up to 2 m from measuring point Certificate: EEx ia IIC T6 EEx ia IIB T6 Endress +Hauser The Power of Know How

[Ex ia] CH1 T CH1 [Ex ia] CH1 CH2 T CH3 CH1 CH2 CH3 Measuring System Components The measuring system comprises the Nivopuls FDU 10 S, attached to the vessel at a position suitable for minimum or maximum level detection, the separate electronics unit as well as a Nivotester FTL 320, or FTL 370/372, FTL 375 P switching unit with relay. Nivopuls units with certificate can be used in explosion hazardous areas; the Nivotester must always be installed in a safe area. Electrical Connection The Nivotester supplies the Nivopuls measuring cell with direct current via a two-wire cable and receives a frequency from there, which signals whether the limit level has been reached or not. The supply current is superimposed with current pulses (PFM signals) with a pulse width of approx. 200 ms and an amperage of approx. 10 ma by the transmitter. Note Using the FTL Nivotester can affect the maximum length of the lead. This is dependent on where the measuring cell is used (hazardous area/ non-hazardous area) and the certificate required for this area. The following apply for using the Nivopuls FDU in hazardous areas: Nivotester FTL supply current Nivopuls FDU input current Nivopuls FDU 10 S with Nivotester for hazardous areas Observe maximum lead length Nivopuls Certificates acc. to product structure (p. 10) Max. input current FDU 10 S B EEx ia IIC 150 ma Nivotester Maximum output current Io or Ik 96 ma FTL 320/370/372/375 P 77 ma Nivopuls FDU 10 S ENDRESS+HAUSER NIVOPULS Max. lead length * 12,5 Ω at 0.75 mm² per wire 0m 450 m 2

[Ex ia] CH1 T CH1 1A 1B 1A 1B 250 V/6A~ 250 V/6A~ [Ex ia] CH1 CH2 T CH3 CH1 CH2 CH3 Nivopuls FDU 10 S with Nivotester FTL 3xx for hazardous areas Observe maximum lead length Nivopuls Certificates acc. to product structure (p. 10) Max. input current FDU 10 S 2 EEx ia IIB 77 ma Nivotester Maximum output current Io or Ik FTL 320/370/372/375 P 77 ma Nivopuls FDU 10 S FTL 370 FTL 372 FTL 375 P FTL370 ENDRESS+HAUSER NIVOPULS FTL 320 ENDRESS + HAUSER NIVOTESTER FTL 320 Max. lead length * 25 Ω at 0.75 mm² per wire 0m 900 m Nivopuls FDU 10 S with Nivotester FTL 3xx for non-hazardous areas Observe maximum lead length Nivopuls Certificates acc. to product structure (p. 10) FDU 10 S 1 Non-hazardous area Nivotester FTL 320/370/372/375 P Maximum output current Io or Ik 96 ma 77 ma FTL 370 FTL 372 FTL 375 P FTL 370 Nivopuls FDU 10 S FTL 320 ENDRESS + HAUSER NIVOTESTER FTL 320 ENDRESS+HAUSER NIVOPULS Max. lead length * 25 Ω at 0.75 mm² per wire 0 m 900 m 3

Measurement Principle Tank empty: long ringing time Tank full: short ringing time Basic principle of ultrasonic resonance method Ultrasonic Resonance Principle The Nivopuls FDU 10 S operates on the ultrasonic resonance principle. The sensor, which is acoustically coupled to the vessel wall by means of a coupling paste, generates a short ultrasonic pulse, which causes a local resonance in the vessel wall. When the pulse ends, the resonance dies away, whereby the ringing time depends upon whether or not liquid is to be found immediately behind the sensor. The sensor, which now operates as a receiver, measures the ringing time and generates an empty or full signal as appropriate. The signal is evaluated by a Nivotester FTL switching unit. 4

Operating and Display Elements Operation The user interface of the Nivopuls is of simple design. The operating elements include: Two keys within the housing, which allow an empty and full calibration, in any order, when the vessel is filled to the appropriate level. A DIP switch which determines the evaluation mode and function of the LED display. 1 2 3 4 Sensor LED Operating mode Calibration full empty Signal strength The display elements are clearly visible, even with closed housing. A yellow sensor LED indicates the state of the sensor: on = uncovered, off = covered A green LED chain indicates the signal strength in normal operation or the calibration status during calibration. Operating and display elements Step Key LEDs 1 Reset 5s after 5 s 2 Empty calibration 3 Full calibration 4 Operation 1s 1s 1-2 min. 3-4 min. Calibration sequence LED off LED LED on LEDs light sucessively during calibration 5

ENDRESS+HAUSER NIVOPULS Installation The remote electronics unit is mounted on a wall or pipe (with mounting set). The sensor housing can be attached to the vessel wall or pipe by means of: adhesive or a tension band The most suitable mounting method for each application can be found in the table below. D separate electronics unit switch point If required, tension band (assembly kit Part. No. 942676-0000) sensor with sensor housing and plug cable length 2 m switching unit FTL 3xx Mounting the measuring system Pipe/tank dimensions Material Sensor housing fastening D adhesive tension band Selection table for mounting method Pipes + tanks ø 200 Steel + glass yes up to 2 m Pipes + tanks ø 200 Plastic yes up to 2 m Adhesive Suitable adhesive is supplied. For the sensor housing, this may be replaced by any other appropriate type. For the sensor itself, however, any substitute must ensure good acoustic coupling. Two-component and moisture-curing adhesives are not suitable (bubble formation). Electronics Unit Mount the remote electronics unit at a suitable location close to the sensor the sensor cable is 2 m long the operating temperature of the electronics unit is 20 C...+80 C. There are two possibilities for mounting: wall mounting, see page 6 for dimensions pipe mounting using pipe mounting set, comprising bracket, backing plate and screws, PN 942676-1100, see diagram. Note! Note! Extending or shortening the sensor cable will detrimentally affect the electromagnetic compatibility of the measuring system. 6

Installation sensor housing sensor TNC connector apply adhesive to feet and housing wings nose protective sleeve clamping screw Fastening with adhesive clasp self-adhesive band holder sensor housing cable tie sensor hook nose Fastening with tension band and adhesive Tension band mounting set Part No. 942676-0000 clamping plate clamping screw TNC connector with protective sleeve 2" pipe base plate holes for wall mounting with (M4) screws mounting bracket screws M4 Installing the electronic housing with pipe mounting set Pipe mounting set Part No. 942676-1100 7

Technical Data Electronics unit 86 127 77 Screws M4 8 127 116 ENDRESS+HAUSER NIVOPULS ENDRESS+HAUSER NIVOPULS 66 Housing cover can be removed to access operating elements cable length 2 m 60 48 29 70 Sensor housing with sensor and mounted plug 102 Dimensions in mm Application Manufacturer Endress+Hauser Designation Nivopuls FDU 10 S Application Level limit switches measuring from outside for thin liquids with separate electronics unit (but not fluids subject to build up) Function and System Design Measurement principle Ultrasonic resonance principle Measuring system Nivopuls ultrasonic sensor, electronics unit, with switching unit Nivotester FTL 320, 325 P or Nivotester FTL 370/372, 375 P Operating frequency Type 1: 0.9...1.6 MHz; Type 2: 0.7...1.2 MHz; Type 3: 0.25...0.45 MHz, see Product Structure Input Measured variable Level limit detected by the ringing time of a short ultrasonic pulse, compared to one obtained with empty and full vessel Output Output signal Status full or empty as pulse frequency modulated signal for switching unit Output on alarm PFM signal adopts alarm status (recognised by Nivotester) Accuracy Reference conditions Temperature T = +20 C, operating pressure pe = 1 bar, flat, vertical metal wall Response time Less than 3 s for liquids with viscosity approx. 50 mm 2 /s (cst); less than 1 s for liquids with viscosity approx. 5 mm 2 /s (cst) Switch point Determined by mounting position of sensor, however, always in lower half of sensor head. Measured error ± 5 mm of absolute position Reproducibility ± 3 mm of absolute position Effect of ambient temperature ± 7 mm of absolute position over operating temperature range 8

Operating Conditions Installation Position Vessel material Wall thickness Vertical on flat walls or standing cylinders Horizontal on horizontal cylinders Sensor head in contact with wall (adhesive or tension band) Acoustic coupling through adhesive Metal, enamelled metal, glass and plastic vessels, however, not for materials PVDF and PTFE, double-walled vessels and vessels with plastic linings Metal and glass: 2...15 mm; Plastic and fibreglass-reinforced plastic 1...10 mm Environment Ambient temperature Sensor: 20 C...+60 C for adhesive supplied; Electronics: 20 C...+80 C Limiting temperature range Sensor: 20 C...+60 C, dependent on adhesive Electronics: 20 C...+80 C Storage temperature Sensor and electronics: 40 C...+100 C Climatic class IEC 68, Part 2-38 as Fig. 2a Ingress protection Electronics: IP 65 with housing closed, IP 20 with housing open for calibration Vibrational strength IEC 68, Part 2-6 Electromagnetic compatibility Interference emission to EN 61326, Electrical Equipment Class B Interference immunity to EN 61326, Annex A (Industrial) and NAMUR recommendation NE 21 (EMC) Medium Limiting product temperature Viscosity 20 C...+100 C, for adhesive supplied 20 C...+60 C 20 C...+60 C for sensor version for plastic vessels Thin liquids, emulsions, suspensions and liquefied gas, up to 100 cst Mechanical Construction Design See diagram, page 8 Weight Sensor with housing: approx. 0.12 kg Electronics unit housing: approx. 0.5 kg Material Sensor housing: plastic PBT-FR; sensor: PEEK Electronics unit housing: PBT-FR; base plate: PPS Tension band (with accessories): 1.4301 Pipe mounting set: 1.4301 Electrical connection Two-wire cable with plug connection, li 77 ma: max. length 900 m or max. resistance 25 Ω per wire li 150 ma: max. length 450 m or max. resistance 12,5 Ω per wire User Interface Operation 2 keys for empty and full calibration Display 1 status LED 1 LED chain, consisting of 5 LEDs, for signal strength Power supply Power supply Provided by Nivotester FTL 320, 325 P or FTL 370/372, FTL 375 P switching unit Certificates and Approvals Explosion protection Europe: EEx ia IIC/IIB CE Mark By attaching the CE Mark, Endress+Hauser confirms that the Nivopuls FDU 10 S fulfils all legal requirements of the relevant EU directives Ordering Information Ordering information See Product Structure, page 10 9

Product Structure Application for lead lengths up to 900 m Nivopuls FDU 10 S Certificate 1 For non-hazardous area use 2 ATEX II 2 G, EEx ia IIB T6 li = 77 ma, not for use with 9 Special version Housing 1 Plastic housing 9 Other housing Mounting Plate 1 Plastic PPS, ø min. 200 mm 9 Other mounting plate Sensor: Vessel Material and Wall Thickness 1 Metal and glass, 2...3 mm und 4...7 mm 2 Metal and glass, 3...4 mm und 7...15 mm 3 Plastic 1...10 mm 9 Other sensor FDU 10 S Product designation Product Structure Application for lead lengths up to 450 m Nivopuls FDU 10 S Certificate B ATEX II 2 G, EEx ia IIC T6 li = 150 ma 9 Special version Housing 1 Plastic housing 9 Other housing Mounting Plate 1 Plastic PPS, ø min. 200 mm 9 Other mounting plate Sensor: Vessel Material and Wall Thickness 1 Metal and glass, 2...3 mm und 4...7 mm 2 Metal and glass, 3...4 mm und 7...15 mm 3 Plastic 1...10 mm 9 Other sensor FDU 10 S Product designation 10

Accessories Tension band set (hook and clasp, clamping plates and band), also required for rail mounting Part-No.: 942676-0000 Pipe mounting set (mounting bracket, base plate, screws) Part-No.: 942 676-1100 Supplementary Documentation Nivopuls FDU 10 System-Information SI 025F/00/en Nivopuls FDU 10 C Compact version Technical Information TI 248F/00/en Level limit switch Nivotester Technical Information TI 350F/00/en Switching Unit Nivotester FTL 370/372 Technical Information TI 198F/00/en Switching Unit Nivotester FTL 320 Technical Information TI 203F/00/en Level limit switch Nivotester FTL 375 P Technical Information TI 360F/00/en 11

Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 9 75-02 Fax (07621) 975-345 http://www.endress.com info@ii.endress.com Endress +Hauser The Power of Know How 08.99/MTM TI 275F/00/en/04.02 SL/CV5