AHJ Field Inspector Guide For: AES-IntelliNet Private Radio Network Installation Sites

Similar documents
AHJ Resource Guide. Authority Having Jurisdiction (AHJ)

AHJ Resource Guide. Authority Having Jurisdiction (AHJ)

AES IntelliTAP. Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device. Version Installation Guide CONTENTS

7706-ULF Integrated Fire Monitoring System. Installation, Operation & Programming Manual

Conventional Releasing Control Panel

Claremont Fire Department

D7053. Installation Instructions Multiplex Input/Output Module

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

FireNET Plus Wiring Instructions

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Notification Appliance Circuit Module

DS7400Xi Addressable Control/ Communicator

Fire Control/Communicator

Full Service Central Station Fire Alarm Listing Evaluation

Installation & Operation Manual

D7044. Installation Instructions Multiplex Single Input Module

Helios W.E.S & 2000 (Wireless Emergency Stop) User Guide. E6, Version 1.2. Helios Global Tech Ltd.

D2412 Control / Communicator Installation Manual

FMR Installation Instructions. Addressable Fire System Controller

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

FIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y

D7052. Installation Instructions Multiplex Dual Input Module

Installation Guide. Control/Communicator

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MANUAL RESET ALARM RELEASE

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

APPLICATION NOTE. Introduction. Contents DMP DATA NETWORK CERTIFICATES APPLICATION NOTE

MANUAL RESET ALARM RELEASE

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Fire Operator Workstation (Fire OWS) User s Guide

Addressable NAC Output Module D327A

4100U City and Relay Cards Installation Instructions

D2071A. Operation & Installation Guide Fire Alarm Control Panel

D2071A Fire Control/Communicator Digital Alarm Communicator Transmitter (DACT)

FIRE & LIFE SAFTEY STANDARD

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

DGC-500 DIGITAL GENSET CONTROLLER

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

RELEASE DEVICE CONTROLS

CERTIFICATION BULLETIN

MODEL B2 INSTALLATION MANUAL

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

ERS-3600B. PERS-3600B Personal Emergency Reporting System

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

MANUAL RESET ALARM RELEASE BOX

Control/Communicator

FIRE ALARM SYSTEM INSPECTION

These instructions detail procedures to follow in order to avoid damage to equipment.

StarLink SLE Commercial Series Dual-Path Alarm Communicators INSTALLATION INSTRUCTIONS

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

OJD ITB No Attachment E Duress Alarm Equipment Specifications

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

Fire Alarm System Inspection and Testing Report

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

PERMACONN PM1030 Includes DI300. Installation Manual

Division 28 - Electronic Safety and Security

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

TrueAlarm Analog Sensing

Doc. No Part No Rev. U * T*

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Model 17A00 Expansion Enclosure

TECHNICAL DATA OBSOLETE

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

July 14, 1999 DF C-100.

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

Version /17. Honeywell Gamewell-FCI Honeywell Security and Fire 12 Clintonville Road Northford, CT 06472

June 10, 2002 DF C S2424

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

DGC-1000 DIGITAL GENSET CONTROLLER

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

EVO192 v3.0 Fire and Burglary What s New

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

MODEL 5128/29. Installation Manual. Fire Slave Communicator. Trim Line. Part Number D, 06/02

2000 Series. Program Entry Guide. Control Panels

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

D1255RB/D1256RB/D1257RB

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ARCHITECT AND ENGINEER SPECIFICATIONS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

Transcription:

AHJ Field Inspector Guide For: AES-IntelliNet Private Radio Network Installation Sites Where to Find AES-IntelliNet in NFPA-72 Code Identifying UL Subscriber Model is UL 864, Ed 9 Listed for Fire Alarm Communications Validating That the Subscriber Meets Multiple Path Requirements UL Subscriber Programming Options Required for UL Compliance Subscriber AC Power Requirements and Trouble Supervision Requirements Remote Antenna Options No UL Restrictions Safety Considerations: All equipment must be installed in accordance with National Electric Code, NFPA-70, NFPA-72 and local building codes.

NFPA-72 Compliance Sections Year 2002 8.5.3.5 Table on A.8.5.1 Year 2007 8.6.3.5 Table on A.8.6.1 Year 2010 26.6.3.2 Table on A.26.6.3.3.2

U.L. Listings AES Corp UL File # S5103 UOJZ.S5103 Control Units, System 7705i, 7170 CS RU Central Station System (Receiving Unit) P RU Proprietary System Type (Receiving Unit) RS RU Remote Station System Type (Receiving Unit) 1W RF Radio Frequency (one-way private radio)

U.L. Listings AES Corp UL File # S5103 UOXX.S5103 Control Unit Accessories, System Dialer Interface Module 7067 IntelliTap, 7794 IntelliPro, Fire 7770 FireTap One-Way RF Transceivers 7744-F, and 7788-F Fire Transceivers are listed to provide primary alarm communications when connected to any FACP that is capable of providing dry contact outputs for alarm, trouble and supervisory conditions. Product also serves as a repeater within the AES mesh network

UL Fire Installation Site Requires that either a 7788-F or 7744-F AES-IntelliNet Subscriber be connected to a UL listed FACP The following is a Hand Held Display of U.L. Fire Basic Requirements: Press Shift F4 on Handheld Programmer Validation that AES Model # on Top Line of Handheld is 7788-F, or 7744-F

AES-IntelliNet Multi Path Concept Each protected premise outfitted with an AES subscriber is linked to the AES-IntelliNet network by this subscriber unit. The network allows distant subscribers to relay alarm messages to the network receiver hub. Signals follow options at that moment, ensuring fast, reliable alarm communications.

Multiple Path Validation All fire alarm installations require 2 paths which is validated on AES-IntelliNet with a Netcon reading of 5. To validate that an AES subscriber has multiple paths of communications available, conduct the following with your handheld (HH) programmer: Step 1 Connect HH programmer to subscriber unit Step 2 Press F4, or CTRL T to view routing table Step 3 Netcon 5 confirms multiple paths are present AES technician of installing company will be pleased to provide this data for your inspection.

In-Depth Netcon Explanation Understanding the Main display will help in confirming the transmission path that the unit is using to communicate The Term NETCON is used to describe the NETWORK CONNECTIVTY To satisfy NETCON the subscriber has establish a minimum of 2 unique paths from its installation location. Below are examples that describe the differences: NETCON 7 The Subscriber has found no stable transmission route NETCON 6 The Subscriber has only (1) established route NETCON 5 The Subscriber has established (2) two separate routes thus satisfying UL requirements for 2 routes

AES Reference Definitions Link Layer Level on handheld programmer; indicates number of hops from protected premise to network receiving hub. Link layer 1 is directly connected, Link layer 2 connects through 1 subscriber unit, etc NETCON NETwork CONnectivity is the internal rating function used by AES-IntelliNet radio units to maintain place in network. Rating of 5 indicates multiple paths are in place to the dispatch center RT 1 Refers to first route, primary route in routing table Dynamic Routing Table Provides real time peer list of network devices that this site communicates through to pass data to dispatch center

Programming Options Required for UL 864 Compliance NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, certain programming features or options must be limited to specific values or not used at all as indicated below: Program Group Permitted in Feature or Option UL 864 (Y/N) Settings permitted in UL 864 Timing Parameters (24 hour check-in) Y AC Fail Report Delay Y R (Random) or 0-60 (Minutes) Reporting Delay Y 10 20 Seconds Zone Programming Fire/Trouble PKT Y Y Zone Programming Y If zone is in use F If not in use B Restoral Y R Set Modes Enable Repeating Y Y Suppress AC Fail N N By Remote programming only Acknowledge Delay * Y Not greater than 60 Seconds * Acknowledge delay is used in detecting the existence of a functional antenna and therefore affects antenna cut detection.

UL - 24 hour Timer Confirmation Confirm 24 hour requirement using a Handheld programmer using the ( Control + F2) Hour Setting For Timer Test The approved timer test interval is ( 24 hours Max)

UL Points of Protection Set to F on the Subscriber Using the handheld programmer confirm zone types ( Control + F3) Confirm that all zones being used for fire are programmed in as ( F ) All Zones being used for Fire system transmission must be defined as ( F ) Confirm all zones used provide a restore signal as shown ( R ) Zone set for restoral

AC Power Requirements Note AC power wiring must be physically protected and have the following Transformer Enclosure Part #AES 1640-ENCL With Transformer Power In: 16.5VAC, 40VA, Class 2 (dry) source only Use AES P/N 1640, or AMSECO P/N XF1640 The transformer shall be secured with the attachment screw

Local Supervision of Subscriber Trouble Conditions For RF Type 6 Fire Alarm Systems, and Central Station Burglar Alarm Systems The J4 will change state when the AES unit has a trouble condition or loss of RF network connectivity may be present. The connection from the J4 must be electronically supervised by either a Piezo with instructions to call, or a trouble output to the FACP Annunciator. The Form C relays are wired Failed Secure to ensure proper 24 hour supervision and immediate annunciation at the protected premise

Remote Antennas Use of Remote Antennas With 7788-F are UL Approved There is no UL restriction on the type of antenna Antennas must be installed in accordance with National Electric Code and local building code. A protective surge arrestor, AES P/N 52-0054 must be installed with any type of Remote Antennas Coax Cable to Antenna Must Be Protected in Conduit (7788-F manual see page #12 for conduit notation)

Thank You For Your Attention Any Questions?