State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

Similar documents
Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Modeling and Simulation on Temperature Control System of Farm Products Baking Equipment. Liu Jun, Jia Zhenwei, Guo Rongxing

GPPS-2017-Put 4 digit paper number here

Experimental study of fan coil assisting radiant floor heating system

Design of Humidity Monitoring System Based on Virtual Instrument

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

CFD Analysis of Fire Characteristics on Subway Junction Station

Analysis to speed up of the start-up of steam boiler OP-380

The Mode of Urban Renewal Base on the Smart City Theory under the Background of New Urbanization

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

Experimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

Study on an environmental simulation system of low/high temperature. for great space

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Experimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss

THE CHARACTERISTICS ON THE GENERATION OF URBAN FORM OF HANGZHOU COMBINING WITH THE HIGH SPEED URBANIZATION

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

Study on the North China Rural Water Supply Project O&M Cost Standard Rating

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

A design of automatic boiler intelligent alert system based on the wireless AD hoc network

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Home appliances simulator for smart home systems testing

Design of Intelligent Humidity Sensing Watering System Based on MCU

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Improving Boiler Stability Through Advanced Regulatory Control

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

Simulation of Full-scale Smoke Control in Atrium

Study on Greenway Network Planning Based on Big Data Social Behavior and Urban Potential Space Framework

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort

Research control strategy of hot air blower de-icing system for MW. wind turbine blade

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Study in Step by Step Electric Energy Meter Connection Detection Method

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Research Progress on Plant Selection of Roof Greening. Shuang Liu+*, Chang-Cun Yuan +,Ting Xuan and Zi-Ya Chen

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b

CONTROLLING BOILER SWELL AND SHRINK

AUTOMATION OF BOILERS USING LABVIEW

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Intensive Use of Urban Land in New Urbanization for China: Issue and Solution

Analysis of Eccentric Wear of Sucker Rod and Design of Multi-Stage Flexibility Stabilizer

An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

The Study of Evacuation Times from the Multiplex Theatres

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

The Development of Automatic Fire Alarm Standards and Related Products in China

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

A study of Transient Performance of A Cascade Heat Pump System

Applications and Discussions of Arc Flash Protection Relay as a Main Busbar Protection in MV Switchboards

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Design and Implementation of Sewage Treatment Control System

Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions

Suzhou Delan Energy Science & Technology Co., Ltd. Focus on control valve for 23 years

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

MODULATING CONTROL OF LOW NO X BURNERS

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

A Design Method Based on Inherent Testability of Remote Control and Monitoring System for Marine Main Engine

Design of Multi-Sensors Cooperation Control System for Intelligent Building

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

Simulation of Evacuation Process in a Supermarket with Cellular Automata

号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd

CHAPTER 3 BASIC STEAM CYCLE

Green Energy Engineering, Inc.

Study on the Protection and Reuse of Industrial Heritage in Resourse-Based Cities DaQing

Transcription:

2017 Joint International Conference on Materials Science and Engineering Application (ICMSEA 2017) and International Conference on Mechanics, Civil Engineering and Building Materials (MCEBM 2017) ISBN: 978-1-60595-448-6 Research on Design Method of Coordination Control System for Ultra Supercritical Power Generation Unit Based on Condensate Throttling Security Control Strategy Jian-Gen HU 1,a, Feng YIN 1,b, Xiao-Qiang CHEN 2,c, Yan-Ni LIU 3,d,* and Zi-Qiang WANG 1,e 1 State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, 310012, China 2 Hangzhou Yi Neng Electric Power Technology Co., Ltd, Hangzhou, 310012, China 3 Zhejiang Gongshang University, Hangzhou, 310018, China a ctgsimon@sohu.com, b wangbing197901@gmail.com, c chenweiming81@163.com, d 499739279@qq.com, e lds1118@zjgsu.edu.cn *Corresponding author Keywords: Condensate throttling, Security control strategy, Ultra supercritical power generation unit. Abstract. Condensate throttling security control strategy is introduced for the problems existing in ultra supercritical power generation unit. Its load and control method are analyzed and discussed. The related results show that this control strategy not only solves the unit pressure fluctuate wildly as well as but also improve the unit operation efficiency. Introduction In recent years, with the rapid development of large capacity and high parameters of supercritical and ultra supercritical units in China, different types of manufacture and control technologies of boilers in the world are introduced by the major equipment manufacturing plants [1]. However, the supercritical unit storage is small and non linear, and in the operation, the unit pressure fluctuates violently and the load response is slow, which needs to be figured out urgently. Based on the analysis of design and debugging experience of ultra supercritical unit coordinated control system which have been put into operation, this paper proposed a design method of coordination control system for ultra supercritical power generation unit based on condensate throttling security control strategy. It can make the actual power changes meet the power requirements, improve the ultra supercritical unit boiler combustion condition, and reduce the number of over temperature and excess pressure significantly. Literature Review Coordinated control system is the core of the production process control of the modern thermal power plant. Based on the calculation of the load instruction and the main steam pressure deviation parameters, the coordinated control system can generate boiler combustion output instructions and hydraulic turbine control flow instructions, which can maintain the energy balance between input and output of boiler and turbine. Due to the inertia of pulverizing system of thermal power unit, internal heat release and spread in a thermodynamic system, and time required for new steam generation, the response of the unit to the steam turbine is much faster than that of the boiler [2]. That is to say, when the power system requires the unit to change the power output rapidly, the power response of the unit is difficult to meet the requirements of the grid in the early stage, which is more prominent in ultra supercritical DC units.

The scholars in foreign countries have begun to study the thermal energy storage technology since the 60s of last century, which can release the energy from the thermal system of the unit, and meet the requirements on the quick change of power that power grid to power system. Since the beginning of 90s of last century, the improved coordination control system based on the technology of condensate throttling has been used in foreign thermal power plants gradually, which achieved good results [3]. At the conference on power grid and power plant control that was hold in 1997 in Beijing, Gehard K. Lausterer who works in SIEMENS Company introduced the use of the coordinated control system based on condensate throttling technology in the German thermal power plant in detail. With the rapid increase of ultra supercritical unit in power grid installed capacity in China, the Chinese scholars have begun to study the condensate throttling technology gradually. Shanghai East China Electric Power Research Institute improved the existing coordinated control system by using condensate throttling technology, which made the condensate throttling technology integrate into the coordinated control system [4]. It also carried out some relevant tests in a plant of Shanghai Waigaoqiao with 2x1000MW unit [5]. And it achieved a rapid change of power when the steam turbine governing valves were fully open. Ultra supercritical units have been the main units of power grid in Zhejiang province. They still adopt the traditional coordinated control system now. Therefore, it s significant to carry out a research on the energy-saving coordinated control system based on condensate throttling. Condensate Throttling Strategy Ultra supercritical unit energy-saving coordinated control was implemented in No. 3 unit of Yuhuan Power Plant. Due to the difficulty in lifting load and simplicity in shedding load, the condensate throttling load adjustment module is simplified. That is to say, only the shedding of condensate throttling load was taken into consideration. The target valve position of No. 3 unit in Yuhuan Power Plant when it s under steady condition is 50%. In the process of variable load, if the load is reduced, the accuracy and space of load control when the steam turbine governing valve is down from 50% are guaranteed as long as the boiler feed forward is basically properly. However, in the process of increasing load, if the steam turbine governing valve starts from 50%, in general, the unit load-increasing trend will be slow immediately when it increases to 65% or more, even if the steam turbine governing valve continues to increase. If the actual main steam pressure drops, it is likely that the actual unit load will reduce while the steam turbine governing valve increases. Thus, the Yuhuan No. 3 unit condensate water load only increases not reduce. From Figure 1 we can see that when the condensate-throttling module receives the load regulation instructions sent by the coordinate module, it would turn into the corresponding condensate to reduce flow rate. After the frequency conversion of No. 3 unit in Yuhuan power plant, the water main valves on the deaerator remain open, and the water is controlled by condensate pump through frequency conversion. The level control of traditional deaerator is controlled by three-impulse regulation. The main part controls water level and the deputy part controls the flow of coagulation tube. Under steady conditions, the main output is equal to the hydrophobic flow of deaerator in different levels. Once the condensed water throttle signal is triggered, according to instructions sent by coordinated control, condensed water throttle module will transfer them to the corresponding decrement of condensate flow rate. And it also remains the original water level control output of deaerator. After the superposition of the two values, the setting value of condensate water flow control will be formed. In order to speed up the response of condensed water throttle load adjustment, calculate the condensed water flow changes and condensate pump speed output, and form feed forward component of condensate pump frequency control of condensed water flow. When the condensed water throttle withdraws, its components reduce slowly to zero at a certain rate. This is to avoid that if the components recover fast, the actual pipe flow will increase rapidly and the actual unit load will decrease immediately, which will affect the unit coordinated load control.

Figure 1. Condensate throttling control. Condensate Throttling Security Control After the movement of condensate throttling, the condensed water flow decreased rapidly, and the deaerator water level declined rapidly. In addition, with the decrease of condensed water flow and cryogenic fluids, the low water level will rise. The water level of heater should be taken into consideration. Besides, the water level of hot well should be taken into consideration. When the condensed water flow decreases, the water level of hot well will increase. Moreover, the condensed water entrance pressure of condensate water treatment system shall not be less than 1.2 MPa, otherwise the condensate water will withdraw. It can be seen from Figure 1 that in order to avoid the occur of fault conditions such as the exit of heater which caused by the low pressure of condensed water pipe and the excess of heater water level during condensed water throttle, the loop value in condensate throttling will be set according to condensed water pipe pressure, water level of deaerator, and change of water level of hot well. If it excesses a certain range, then the condensate throttling range should be controlled partly. The tests results show that the effect of condensate throttling on the deaerator liquid level is the largest. Others like the control of heater and hot well level can be improved by increasing feed-forward and differential element, so as to ensure the liquid level control in a safe range. In order to ensure the safety of the deaerator liquid level, the effect of condensate throttling on the deaerator liquid level should be calculated, or the different space provided by the deaerator when it drops form different liquid level. This can be calculated on the basis of the physical size of the deaerator, the water saturation density of deaerator.

Figure 2. The structure of deaerator. It can be seen from Figure 2 that both sides of section are semicircle and the middle is a rectangle when overlooked at any height. And the length of the rectangle can be known directly from the structure diagram. So the key is to calculate the width of the rectangle that is also the diameter of the semicircle. From the side view we can see that the width is dependent on the section and the height of geometric center. Also it can be seen that the deaerator is round and the radius can be known directly. So if the section and the height of geometric center are known, the width of the section can be calculated. At this point, the surface area of any section of deaerator can be calculated based on the distance of geometric center line of the deaerator. The deaerator liquid level changes within a certain range. if it doesn t exceed the geometric center line, that is to say, the liquid level changes within upper or lower level of geometric center line, the results can be figured out with the method mentioned above. Otherwise the results should be figured out by two parts with geometric center line as the boundary and add finally. Thus, the water volume change of deaerator liquid level generated at any range can be calculated. Then according to the real-time pressure and temperature, we can calculate the real-time density. Finally, the condensate throttling, condensed water flow variation and the duration, and the deaerator liquid level fluctuation range can be determined. Conclusion Aiming at the existing problems in the ultra supercritical unit coordinated control system; this paper introduces the condensate throttling security control strategy and makes an analysis and discussion on the load and control methods. The related results show that the control strategy can not only solve the severe fluctuation of unit load pressure, slow response and other issues, but also effectively improves the running efficiency of the unit, which is of great practical significance. Acknowledgement This research was financially supported by the science and technology project of Zhejiang Province (Number. 2012C31G6130003) as well as Hangzhou science and technology project (No. 20152011A09).

References [1] Gu Junjie, Ji Nailiang, Cao Xiaowei, Yang Yang. Method research and model analysis in the coordinated control of supercritical pressure power unit, Journal of North China Electric Power University, 2013, 40(2): 73-76. [2] Conley A., Salgado M. E. Gramian based interaction Measure, Proceeding of IEEE Conference on Decision and Control, Sydney, Australia, 2000. [3] Niu, Liquan. Application of adjacent unit-provided heating system in supercritical unit, Huadian Technology, 2015, 37(8): 56-59. [4] Zhang Qin, Wei Xiaohong. Analysis of Failure of Supercritical DC Recirculation Pump Motor and Treatment of Actual Fault, Journal of Taiyuan University, 2011, 12(3): 133-135. [5] Fang Fang, Liu Jizhen. Nonlinear control for the coordinated system of generating unit, Electric Power, 2004, 37(7): 61-65.