Leadax B.V. Covenant K93792/02. Leadax

Similar documents
CPVC solvent cements for CPVC pipes and fittings

Vulcanised rubber products for cold and hot drinking water applications

Number K4126/06 Replaces K4126/05. Issued Dated Valid until Indefinite Page 1 of 6

Check valves, family E, type B

Sanitary tapware: mechanical mixers

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Approval Requirements 136

BRL-K602. Datum Evaluation Guideline

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK

Villeroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap.

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 69-1

Evaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

EFFISUS BRAZE MEMBRANE

Evaluation Guideline

Evaluation Guideline. for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water

BRL-K Evaluation Guideline

SPIDER P SPIDER P mineral

Firetect C. Fire protective products: Fire protective board

Viega Technology GmbH & Co. KG

BRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water

RG1,5SA Self Adhesive

BRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

Firestone Lining Systems. Dependable Performance in Demanding Environments

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

Evaluation Guideline. for the KOMO (technical approval-with-) product certificate for

GASTEC QA. Approval Requirements 7. for the GASTEC QA product certificate for bendable gas meter connection pipes. KE 7 March 2012

KQ July 1, Evaluation Guideline

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

BRL-K619/ Evaluation Guideline. for the Kiwa product certificate for WC-pans

SPECIAL SPECIFICATION 3687 Impermeable Liner

Kiwa Regulations for Certification in accordance with the CPR

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Geomembranes that work

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

BRL-K Evaluation Guideline. for the Kiwa product certificate for products used for treatment and / or production of drinking water

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

The Laboratory is qualified to update standards identifying the test procedures.

0014-L-16/1 2 March Test report. EPDM Quickgoot system

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

INSPECTION REPORT Nr IDD/S-09/922

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

European Technical Assessment ETA-14/0176

The Laboratory is qualified to update standards identifying the test procedures.

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

Geomembranes that work

GEOMEMBRANE FIELD INSTALLATION

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

Coatings for protection of FRP structures with heavy rain erosion loads

National technical assessment NTĮ :2013

See product BS EN :2010

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology

DECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK

Declaration of Performance

Fire Protection Scover

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

design BRL-K Evaluation Guideline

DECLARATION OF PERFORMANCE

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

fixed dry aerosol fire extinguishing components FirePro Systems Ltd.

Visqueen Vapour Control Tapes

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

DECLARATION OF PERFORMANCE

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania

Geosynthetic Institute GSI GRI GT13(b) ISO Version

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

DECLARATION OF PERFORMANCE

The Laboratory is qualified to update standards identifying the test procedures. Test procedure/ method identification

Urban Drainage Geomembrane (UDG)

DECLARATION OF PERFORMANCE

INTERNATIONAL STANDARD

Firestone GeoGard EPDM Review of Technical Performances

FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION. Specially developed for use in offshore and industrial environments

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

Declaration of Performance

Introduction. Declaration of performance (DoP) CE marking

Transcription:

561/170522 Covenant K93792/02 Uitgegeven 2017-12-01 Vervangt K93792/01 Pagina 1 of 5 VERKLARING VAN KIWA With this Covenant, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa declares that legitimate confidence exists that the products supplied by B.V. as specified in this product certificate and marked with the Kiwa -mark in the manner as indicated in this product certificate may, on delivery, be relied upon to comply with Kiwa Covenant manual K15013 dated 01-01-2016. Luc Leroy Kiwa Publication of this certificate is allowed. Advice: consult www.kiwa.nl in order to ensure that this certificate is still valid. Kiwa Nederland B.V. Sir Winston Churchilllaan 273 Postbus 70 2280 AB RIJSWIJK Tel. 088 998 44 00 Fax 088 998 44 20 info@kiwa.nl www.kiwa.nl Leverancier B.V. Vlijtweg 4 8191 JP WAPENVELD Tel. +31 (0)85-0653746 info@leadax.com www.leadax.com

page 2 of 5 1 Scope of the Covenant 1.1 Definition of the product Lead Free Flashing, made of recycled Polyvinylbutyral (PVB) Specification nominal value: Length: 6,0 m Width: 15-100 cm Thickness: 3,0 mm Delivered: on roll Intended use of can be used as a water barrier in (cavity) walls and under casings; At the intersection between chimney bases and roof tiles; At chimney flashings to provide a water barrier; can be applied to the base of dormers and skylights as a waterproofing layer and at the joint between dormer side walls and tiled roofs; As a watertight connection between an outside wall and an extension. Use masonry clips to attach to masonry joints; can be used as valley gutters and waterproofing on the ridges of (tiled) roofs. 1.2 Assumed working life of the product The provisions and the verification and assessment methods included or referred to in this Kiwa Covenant have been written based upon the assumed working life of the waterproofing system for the intended use of at least the life expectance of waterproofing system of 20 *) years. These provisions are based upon the current state of the art and the available knowledge and experience. *) Remark: The expected life time is 30 years, confirmation tests under extreme conditions are running. Assumed working life" means that, when an assessment following the Kiwa Covenant provisions is made, and when this working life has elapsed, the real working life may be, in normal use conditions, considerably longer without major degradation affecting the requirements. The indications given as to the working life of the construction product can not be interpreted as a guarantee given by the product manufacturer or his representative or Kiwa Nederland B.V. issuing the Kiwa Covenant, but are regarded only as a means for choosing the appropriate products in relation to the expected economically reasonable working life of the works. 2 Fitness for use 2.1 Meaning of fitness for use Fitness for (the intended) use of the flashing system means that the products have such characteristics that, when properly designed and built, satisfies the requirements of this Kiwa Covenant and is fit for its intended use and in this connection satisfies the requirements of this Kiwa Covenant, when properly installed. 2.2 Assessment of fitness for use The relevant characteristics of the waterproofing system for its fitness for use (requirements) and the required verification methods to be employed are given in chapter 3, as well as the actual performed assessment of fitness for use and proven conformance to the relevant characteristics of the waterproofing system and its components. 3 Relevant characteristics of the product, the required verification and the assessments of fitness for use 3.1 Dimensions Length EN 1848-2 6,0 m Width EN 1848-2 15 100 cm Thickness EN 1849-2 3,0 mm Mass / m2 EN 1849-2 3,85 kg/m 2 Visual defects EN 1850-2 No visible defects Dimensional stability EN 1107-2 0,0 %

page 3 of 5 3.2 Reaction to fire Reaction to Fire EN 13501-1+A1:2009 Class E 3.3 Functional properties Water tightness EN 1928 - B 500 kpa Water tightness of joints (Hot air) EN 1928 - B 10 kpa Water absorption M.O.A.T 66 1,06 % Water tightness (After 2400 hrs UVB test) EN 1928 B 500 kpa Water Vapour Transmission EN 1931 Density moisture flow rate (g): 5,26.10-8 kg.m-2.s-1 Moisture resistance factor (µ ): 2360 Water Vapour Transmission after thermal ageing EN 1296 + EN 1931 Density moisture flow rate (g): 5,20.10-8 kg.m-2.s-1 Moisture resistance factor (µ ): 2370 3.4 Mechanical properties Tensile properties: Maximum tensile force length direction EN 12311-2 500 N/50 mm Maximum tensile force width direction EN 12311-2 1200 N/50 mm Elongation at break length direction EN 12311-2 80 % Elongation at break inwidth direction EN 12311-2 15 % Tear resistance length direction EN 12310-1 400 N Tear resistance width direction EN 12310-1 400 N Static loading (method B) EN 12730 20 kg Impact resistance (method B) EN 12691 2000 mm Hail resistance (hard support) EN 13583 44 m s -1 Resistance to peel (concrete) M.O.A.T 66 162 N/50 mm Resistance to peel (concrete) after thermal ageing at 80 C, 12 weeks M.O.A.T 66 143 N/50 mm Low temperature foldability EN 495-5 -70 ⁰C Low temperature foldability after thermal ageing at 80 C, 12 weeks EN 495-5 -70 ⁰C 3.5 Raw materials Raw materials are inspected upon arrival according to procedures laid down in ISO 9001:2015 3.6 Joint strength ( Sealant) Peel resistance: Length direction EN 12316-2 250 N/50mm Width direction EN 12316-2 250 N/50mm Shear resistance: Length direction EN 12317-2 500 N/50mm Width direction EN 12317-2 1200 N/50mm

page 4 of 5 3.7 Joint strength (Hot air) Peel resistance: Length direction EN 12316-2 300 N/50mm Width direction EN 12316-2 400 N/50mm Shear resistance: Length direction EN 12317-2 500 N/50mm Width direction EN 12317-2 1200 N/50mm 3.8 Chemical resistance Chemical resistance to lime milk (Ca(OH) 2) EN 1847 Pass 3.9 Compatibility Compatibility with bitumen BRL 1511-1 Pass Compatibility with PVC BRL 1511-1 Pass 4 Initial inspection and continuous surveillance by Kiwa 4.1 Initial inspection During an initial inspection the IQC-scheme is audited, testing is witnessed and samples are taken for verification. Continuous surveillance will be performed two times a year, during which the process, the IQC-scheme is inspected. 4.2 Continuous surveillance Test frequency Characteristic Method Test frequency Length EN 1848-2 once per batch Width EN 1848-2 once per batch Thickness EN 1849-2 once per batch Mass / m 2 EN 1849-2 once per batch Visual defects EN 1850-2 once per batch Chemical resistance (Lime milk) EN 1847 Low temperature foldability EN 495-5 once per 5 years Impact resistance EN 12691 once per 5 years Tensile strength EN 12311-2 once per month Elongation at break EN 12311-2 once per month Static loading EN 12730 once per 5 years Hail resistance EN 13583 Reaction to fire EN 13501-1:2007+A1:2009 Water tightness EN 1928 once per 5 years

page 5 of 5 Peel resistance of joints EN 12316-2 Shear resistance of joints EN 12317-2 Peel resistance (concrete) M.O.A.T 66 Peel resistance (concrete) after thermal ageing M.O.A.T 66 Tear resistance EN 12310-1 once per month *) In case of unchanged materials and or unchanged production process the frequency may be expanded to 10 years. 5 Conditions under which the fitness for the intended use is assessed 5.1 Manufacture of the product is produced from a combination of materials according to written specifications as documented in the formulation. The formulation is part of the IQC-scheme and of the audits performed by Kiwa. The production facility is situated in Wapenveld, The Netherlands. The product is produced in rolls: Nominal thickness 3 mm; Nominal length 6 m; Nominal width 15 100 cm; Each roll shall carry a batchnr.; Each roll shall carry the Kiwa word mark: Kiwa, the certificate number or the applicable logo. 5.2 General conditions for product application, storage and transport For current application instructions refer to the packaging. 5.3 Recommendations for customers Check at the time of deliver whether: the supplier has delivered in accordance with the agreement; the mark and the marking method are correct: the products show no visible defects as a result of transport etc. If you should reject a product on the basis of the above, please contact: BV And, if necessary, Kiwa Nederland B.V. Consult the suppliers processing guidelines for the proper storage and transport methods.