Energy Audit- Spice Powder Making. Plot 2, 1 G, Leela Infopark, Technopark, Trivandrum , Kerala, India. Tel:

Similar documents
Installation, Operation, and Maintenance Information

Save energy with oil-free water-cooled compressors. Energy recovery solutions (ER )

CAMAIR THE LEADER IN DRY AIR TECHNOLOGY

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com

Thermax Consultancy Services

ENERGY CONSERVATION IN COMPRESSED AIR SYSTEMS BEE KNOWLEDGE EXCHANGE PLATFORM PULP & PAPER SECTOR

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

ENERGY EFFICIENCY IN PRODUCTION OF EXTRUDED FEED

Largo & Allegro. Air Compressors LARGO & ALLEGRO

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Energy Impacts of Compressed Air

SERVICE BULLETIN A

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

Rollair. Air Compressors. Rollair 15-40E

electric, 150 r/h, left>right Dishwashing Dishwashing Multi-rinse Rack Type Dishwasher with Energy Saving Device, electric, 150 r/h, left>right

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

SCK. Air Compressors SCK 3-40 & ALLEGRO 8-11

ITC HOTELS LTD. Project Titles

HEATING AND VENTILATION

green&clean multi-rinse Rack Type, Energy Saving Device, medium

ENERGY CONSERVATION IN COMPRESSED AIR SYSTEMS

electric, 150r/h, R>L Warewashing Warewashing green&clean multi-rinse Rack Type, Energy Saving Device, large dryer, electric, 150r/h, R>L

Let us first understand how costs / savings are calculated. We know that, Boiler Efficiency ( η ) =

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

Daikin Direct Expansion (DX) Cooling Coils

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

Switch your compressor into an energy source

Page 1 of Relevant Provincial Jurisdictional legislation.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

NEW CHILLER SCHEDULE

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS).

UNIT 4: REFRIGERATION PRINCIPLE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

A new concept at refueling CNG stations

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Ashirwad Carbonics (India) Private Limited

Compressed Air Systems

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS

Compressed Air Systems. Scott Wetteland, CEM, DNV GL July 2018

PAPER MACHINE ENERGY FINGER- PRINT. Carl-Fredrik Lindberg 1, Kevin Starr 2, Robert Horton 2, Naveen Bhuthani 3

PRS outlet set at 3.5-4Kg/cm2 of all machines 1Ton /day steam saving Conversion of Condensate pumps from Air to Steam -50 CFM/Hour Air saving

Enhancing Black liquor Evaporation capacity through Process Reengineering

Water cooled VRV IV W-series

Checklists LAUNDRY GREENKEYGLOBAL.COM

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

YOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011

Largo & Allegro. Rotary Screw Compressors LARGO & ALLEGRO

1 - This title will copy onto other forms Date

A Cover. steam & hot water ENERGY EFFICIENT

HVAC Water chiller selection and optimisation of operation

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Dossier on Energy Saving Measures

POWER GENySYS P ROJECT E XPERIENCE I NFORMATION - D ISTRIBUTED G ENERATION

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

DIVISION 15 MECHANICAL

Largo & Allegro. Rotary Screw Compressors LARGO & ALLEGRO 23-36

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Appendix 13. Categories of Cooling and Heating systems

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Rollair. Rotary Screw Compressors ROLLAIR E-50E (V)

PART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM

Rollair. Rotary Screw Compressors ROLLAIR AND ROLLAIR V

Steam Trap Inspection Methods And Steam Cost Analysis

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Sustainable Techniques in Refrigerated Space

ER N ITIO D N O C STARCH CONDITIONING

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Case Study: Mass Balance and Energy Consumption

Genesis Series 5,5 to 22 kw. Compressed air at your service

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Installation, Start-Up and Service Instructions

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Element D Services Heating, Ventilating, and Air Conditioning

September 23rd, Function Description Voltage Size Mfr. Model Add'l info Status Price Molding Machines

CONDENSERS AND CONDENSING UNITS

SIGMA 3 ENGINEERING LIMITED

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

ESN Screw Compressors kw 50 Hz

FT900BD FLIGHT-TYPE DISHWASHER

AHRI Certification Program Scopes - COOLING

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

VertiCool Aurora Engineering Guide

Beneficial Electrification: Exploring the Aggregation of Water Heaters

Transcription:

Energy Audit- Spice Powder Making Plot 2, 1 G, Leela Infopark, Technopark, Trivandrum 695581, Kerala, India. Tel: + 91 47 2700050 1

April-May 2014 A look into Electrical bills... Zone Unit cost(rs) Unit consumed Total cost % cost Normal 4.60 49790 229034.00 51.31 Peak 6.90 16000 110400.00 24.73 Off Peak 3.45 31010 106984.00 23.96 Total cost 96800 446418.00 100.00 Recommendations Identify non critical loads like cleaning, packing etc. Shift non-electrical loads to off-peak hours and bring down the consumption less than 20% Expected cost saving per unit of electrical energy is 50%. 2

A check on Automatic Power Factor Controller... A check on each capacitor showed that one 5 KVAr is derated and not working Recommendation A log sheet as shown below should be maintained and once in 15 days the capacitors must be checked for their current out put. 1 KVAr = 1.33 A, if the de-rating is more than 25% replace the capacitor Date Location 21/5/14 AFC Panel Rating (KVAr) A Rating/P h. A ( Actual) R Y B % De-rating Remark 5 6.65 0 0 0 100 Replace the Capacitor 3

Performance Assessment on Air compressors... Performance at a glance... Type Pow er (HP) Rated cfm Run hr Actual cfm Generat ion eff. Operati ng Pr Actual power Internal Leakage Screw Type 50 170 cfm 24 hr 154 90.58 9 30 10 cfm Reciprocati ng 20 80 cfm Stand by 56 69 8 14 Nil A Leaking Valve is set right during performance testing 4

Performance Assessment on Air compressors... Recommendations... Arrest internal leakages in screw compressors by checking valves and flanges. Remove extra valves in the receiver and air lines and cap the pipe to arrest leakages Unused valves in receiver cause leakages 5

Performance Assessment on Air compressors... Replace inefficient reciprocating compressor with energy efficient screw compressor and save power consumption up to 15% Present consumption 14 kw will reduce to 12 kw Replace GI air pipes with Aluminimum Modular pipes for compressed air network to arrest 100% leakage and reduce pressure drop. Al. Modular Piping Replace inefficient reciprocating compressor, Reduce energy consumption and maintenance cost 6

Performance Assessment on Air compressors... Isolate high pressure air line from cleaning system and group the cleaning locations. Use a small compressors for cleaning at low pressure of 2 bar to reduce power consumption to generate high pressure area. Present consumption is 24 kw. Small compressor of 5.5 kw will consume 4.5 kw. The saving would be 19.5kW. Group the Cleaning Locations & use low pressure air 7

Hidden in-efficiency in Pepper Dryer... Hot Air blower and cold air blowers suction line is.80% chocked No significant air flow measured in these blowers Flow rate from dryer was measured at 551 k/hr Cooler surfaces are insulated Chocked Steam heater coil attached with Hot air blower Cold air suction placed near steam trap and covered 8

Cooler Hidden in-efficiency in Pepper Dryer... Recommendations Regular cleaning of steam heater coil and improve air flow Remove the insulation from cooler surfaces Isolate dryer area from cooler area by providing partitions strips One cooler having the suction near steam trap fan can be removed Clean the suction filter of 2 nd cooler fan and improve the air flow. This flow can be split and connected to the cooler Improve dryer productivity to 1000 kg/r and reduce blower energy consumption by 1.5 kw. Disconnect this blower Blow er Chocked Steam heater coil attached with Hot air blower Cold air suction placed near steam trap and covered Suggested scheme 9

Hidden in-efficiency in Pepper Dryer... Recommendations The steam heater is placed at suction end of the hot air blower. It is recommended to place the steam heater on the delivery side of the steam heater. The higher velocity of air at deliver end of the blower will enhance the heat transfer rate and improve efficiency of heat utilization At present the blower handles hot air thus reducing flow rate due to hot gas. If the blower handles cold air the specific energy consumption will decrease and floe rate will increase Steam heater before suction Steam heater at delivery end EXISTING PROPOSED 10

Improve Boiler Performance... Steam requirement 3.00 Ton/shift (375 kg/h) Boiler utilization is, 20% of its capacity ( 2 ton/h capacity) Condensate left unutilized at the rate of 1.9KL/shift at 75 o C, equivalent to 100 kg of fuel per day Manual fuel feeding is a bottle neck to use low capacity boiler (1 t/h) Recommendations Recover and reuse condensate to save water and fuel Install material handling system for semi automatic feeding of fuel Use low capacity boiler save fuel 11

Reduce cooling tower fan power consumption... Cooling tower fan runs for 24 hrs irrespective of outside temperature and water outlet temperature Fan power consumption 2.5 kw Recommendations Install commercially available cooling tower energy saver and reduce fan power consumption by 15% Cooling tower fan Commercial cooling tower fan controller 12

Monitoring and analysis of energy consumption Install our energy monitoring and analysis software and integrate with production monitoring system Allocate energy cost to each department/mill Bench mark energy cost for utility and production in terms of kwh/ton of production Bench mark CO 2 emission in terms of tco 2/ ton of production Present CO 2 emission related to grid power consumption is 0.93 tco 2 /MWh Plant Lipids CO2 emission = 90 tco 2 /month Expected reduction @5% = 4.5 tco 2 /month 13

Instruments used for this study... PORTABLE MEASURING INSTRUMENTS 14

Triassic Solutions.. Development, installation, integration and commissioning of the complete energy management system Provide solutions for efficient use of compressed air system through improving piping network to arrest air leakage and pressure drop through Al-Modular air piping Consulting the design, installation and commissioning of semiautomatic fuel feeding system for boilers Design, installing and commissioning of condensate recovery system 15

Our approach- Bottom-Up BOTTOM-UP APPROACH Environmental Impact Solution for Sustainability (Policy & Sustainability Indicators) Contribution to GDP EE Technology Application of Mathematical tools to critically evaluate the Drivers and Barriers Policy Measures Identification of Drivers and Barriers for efficiency Improvement Analysis of Inefficiency and scope for improvement Achievable Energy Intensity Energy Intensity Material In EQ-1 EQ-1 EQ-1 EQ-1 Product Energy Carrier 16

How to reach TRIASSIC? Plot 2, 1 G, Leela Infopark, Technopark, Trivandrum 685581 Kerala, India Tel: + 91 471 2700050 Fax: + 91 471 2700050 sales@triassicsolutions.com www.triassicsolutions.com 17