Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Similar documents
for relative humidity and temperature with calibration certificates

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

QPM21 Series Duct CO 2 and Air Quality Sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

for relative humidity and temperature

Room Temperature Sensors

Duct Air Quality Sensors

for relative humidity and temperature

Duct Temperature Sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Air Quality Sensors

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Room air quality sensors

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Powers Controls Low Temperature Detection Thermostat

SCC Inc. FLMTR Series Natural Gas Flow Meter Kits for Boiler Commissioning or Flow Totalization. Technical Instructions

Powers TM Controls ET 134 Line Voltage Room Thermostats

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Active Infrared Multi Beam Sensors

Dual Input ph/orp Analyzer

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Snifter ATEX22 VERSION. User Manual. Distributor

Differential pressure sensors

Hygro/hygrothermal transducers (hygrometric)

Active Infrared Multi Beam Sensors. R Series

Hygro/hygrothermal transducers (hygrometric)

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Dual Input Toroidal Analyzer

Dual Input ph/conductivity Analyzer

POWERS TM Controls HU 186 Room And Duct Hygrostats

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SAFETY INFORMATION AND WARNINGS

Predator Controller Hardware Family

Snifter. User Manual. Distributor

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

POWERS CONTROLS Pneumatic Thermostat Covers

Oxygen (O2) Single-Point Gas Detection System

Room Temperature Controller

Free Chlorine Measuring System

Flame Rod Manual. Publication Rev A

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Sintrol Snifter A1+ Manual. Version 1.2.2

Installation Guide IM 1248

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

LC1350 Level Controller

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Heating Element. Building Technologies HVAC Products

Room Temperature Sensors

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Room Temperature Sensors QAA20 Series /913/914 E-9

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

PRODUCT PRODUCT CODE SPECIFICATION SHEET PAGE #

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

POWERS Pneumatic Thermostat Covers

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

C7232A,B Sensor and Controller

Sensepoint XCL Fixed Gas Detector

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Two-Channel Gas Controller

Duct Humidity/Temp Sensor

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

LC2200 Level Controller Installation and Maintenance Instructions

BC3250. Blowdown Controller

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Outside Air Humidity & Temperature Sensor

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Analog Room Pressure Monitor RPC Series

MP 601A Humidity Probe INSTRUCTION MANUAL

Cooktop Chimney Ventilation Hoods

CP CP

Schneider Electric Erie T155 Series

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Duct and Rough Service Carbon Monoxide Sensor

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

PA ma Loop Powered Level Preamplifier

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Transcription:

Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air monitor and transmit changes in humidity and temperature to the building control systems. Operating voltage 24 Vac/13.5 to 35 Vdc Signal output /4 to 20 ma for relative humidity and temperature Very high measuring accuracy across the entire measuring range Capacitive humidity measurement Precise, stable humidity sensing Available in 2% and 2%, certified models Optional display Recalibration service available (QFA41 Series only) The Q-Series Outdoor Air rh and rh/t Sensors are for use in HVAC applications where high accuracy and short response times for measuring relative humidity are required. The measuring range covers the entire humidity range of 0 to 100%. Some application examples: Storage and production facilities in the paper, textile, pharmaceutical, food, chemical and electronics industry, etc. Laboratories Hospitals Computer and EDP centers Greenhouses Outdoor use requires AQF3100 Outdoor Mounting Kit

Document Number 155-755 Q-Series Outdoor Air and Critical Environment Relative Humidity and Relative Humidity & Temperature Sensors Product Numbers Table 1. Product Number Accuracy Display Temperature Measuring Range Temperature Signal Output Humidity Measuring Range Humidity Signal Output Operating Voltage QFA3100 QFA3101 QFA3160 QFA3160D QFA3171 QFA3171D QFA4160 QFA4160D QFA4171 QFA4171D 2% 2%, certified Field selectable: 32 F to 122 F (0 C to 50 C), -31 F to 95 F (-35 C to 35 C), or -40 F to 158 F (-40 C to 70 C) 4 to 20 ma 4 to 20 ma 0 to 100% 4 to 20 ma 24 Vac or 13.5 to 35 Vdc 13.5 to 35 Vdc 24 Vac or 13.5 to 35 Vdc 4 to 20 ma 13.5 to 35 Vdc 24 Vac or 13.5 to 35 Vdc 4 to 20 ma 13.5 to 35 Vdc Accessories 74 662 01040 US rigid 1/2-inch conduit adapter Outdoor Mounting Kit AQF3100 AQF3101 AQF3150 AQF4150 AQF3100 Warning/Caution Notations Sensor filter cap (replacement) Replaceable, 2% sensor tip Replaceable, certified sensor tip Outdoor Mounting Kit (including sun shield) The Outdoor Mounting Kit consists of: One wall mounting bracket complete with sun shield Four Phillips-head screws, K35 12 One grommet M 16 1.5 with O-ring and nut M 16 1.5 for closing off the sensor's cable entry hole if not required. WARNING: CAUTION: Personal injury, or loss of life may occur if you do not perform a procedure as specified. Equipment damage may occur if you do not perform a procedure as specified. Page 2

Q-Series Outdoor Air and Critical Environment Technical Instructions Relative Humidity and Relative Humidity & Temperature Sensors Document Number 155-755 Ordering Information Equipment Combinations Technical Design Relative Humidity Temperature The AQF3100 outdoor mounting kit listed under Accessories must be ordered as a separate item. The circular connector with its screwed plug is delivered uninstalled (QFA4160). The Q-Series Relative Humidity and Relative Humidity & Temperature Sensors can be used with all types of systems and devices that can acquire and handle the sensor s 0 to 10 Vdc or 4 to 20 ma output signal. The sensor acquires relative humidity via its capacitive sensing element; the capacitance varies as a function of the relative humidity of the ambient air. An electronic circuit converts the sensor's signal to a continuous or 4 to 20 ma signal, which corresponds to a relative humidity of 0 to 100%. The sensor acquires the temperature via its sensing element; the electrical resistance varies according to the temperature of the ambient air. This variation is converted to an active or 4 to 20 ma output signal, corresponding to a temperature range of 32 F to 122 F, -31 F to 95 F, or -40 F to 158 F (0 C to 50 C, -35 C to 35 C, or -40 C to 70 C). The measuring range is selected by repositioning factory-supplied jumpers. Resistive Load Diagram Figure 1. Output Signal, Terminal I1/I2. Mechanical Design The room sensor consists of housing, printed circuit board, connection terminals and measuring rod. The housing consists of two parts: base and removable cover (screwed). The QFA4160 also has a circular connector. The measuring circuit and the setting element are located inside the cover of the printed circuit board; the connection terminals are in the base. The housing and measuring rod are screwed together. The sensing elements are located at the end of the measuring rod and are protected by a screw-on filter cap. For the QFA31 Series, the M16 cable entry gland supplied with the sensor can be screwed into the bottom of the base. If the sensor is used outdoors, that opening must be closed off and the prepared hole on the opposite side of the base knocked out. For the QFA41 Series, the cable entry is made via the circular connector, which consists of a coupling piece with M16 thread and a connector with a screwed plug. The coupling piece is secured to the housing and internally wired. The sensor is designed for wall mounting. Page 3

Document Number 155-755 Q-Series Outdoor Air and Critical Environment Relative Humidity and Relative Humidity & Temperature Sensors Setting Element Figure 2. Configuring the Jumpers. The setting element is located inside the cover. It consists of six pins and a jumper. They are used to select the required temperature measuring range and to activate the test function. The different jumper positions have the following meanings: Behavior in the Event of a Fault Calibration Certificates (QFA41 Series only) Engineering Notes Cable Routing and Cable Selection For the active (0 to 10V or 4 to 20 ma) temperature measuring range with the jumper in the: Left position (1) = -31 F to 95 F (-35 C to 35 C) Mid position (2) = 32 F to 122 F (0 C to 50 C) (factory setting) Right position (3) = -40 F to 158 F (-40 C to 70 C) For the active test function: Jumper in the horizontal position: See Figure 2. Jumper Settings for Signal Output Ranges for the values available at the signal output. If the temperature sensor is faulty, the voltage at signal output U2 (I2) is 0V (4 ma) after 60 seconds. The humidity signal at signal output U1 (I1) increases to 10V (20 ma). If the humidity sensor is faulty, the voltage at signal output U1 (I1) is 10V (20 ma) after 60 seconds. The temperature signal remains active The sensor and its exchangeable AQF4150 measuring tip are numbered, registered and calibrated prior to delivery. The associated calibration certificates are supplied with the sensor. Use a safety extra low-voltage (SELV) transformer with separate windings designed for 100% duty. Observe all local and national safety regulations when sizing and protecting the transformer. Take the sensor's power consumption into consideration when sizing the transformer. See the devices' Installation Instructions for the sensor's electrical connection. Observe the maximum permissible cable lengths. Electrical interference increases the longer the cables run parallel and the smaller the distance is between them. Use shielded cables if necessary. Twisted pairs of cables are required for the secondary supply lines and the signal lines. Page 4

Q-Series Outdoor Air and Critical Environment Technical Instructions Relative Humidity and Relative Humidity & Temperature Sensors Document Number 155-755 Mounting Notes Interior Mounting for QFA31 Series without AQF3100 Mounting Position Mounting Instructions Outdoor Mounting for QFA31 Series with AQF3100 Mounting Location Mounting Position Mounting Instructions Commissioning Notes Recalibration Service (QFA41 Series only) Services Provided Mount on an inside wall (not on outside wall) of the room to be air-conditioned. Do not mount in recesses, shelves, behind curtains, above or close to heat sources; or on walls behind which a chimney is located. Do not expose the sensor to direct sunlight. Install the sensor in an occupied space approximately five feet (1.5 m) above the floor and at least 20 inches (50 cm) from the next wall. CAUTION: Do not remove the seal between the housing and cover. The degree of protection IP 65 will be no longer ensured if the seal is removed. Avoid any impact while mounting. The sensing elements inside the measuring rod are sensitive to shock and impact. The sensor must be mounted with the measuring rod pointing downward for the QFA41 Series or the QFA31 Series (without the AQF3100 Outdoor Mounting Kit). Installation Instructions are printed on the sensor's packaging Mount on an exterior wall, preferably on the north or northwest side of the building. If possible, mount in the middle of the wall, at least 8 feet (2.5 meters) above the ground. Do not mount above or below windows, above doors or ventilation shafts, or below balconies or eaves. The sensor and AQF3100 must be mounted in a vertical position (with the sun shield at the top). NOTE: When using the AQF3100 outdoor mounting kit, the sensor's cable entry hole must be closed off with the grommet and the prepared M16 cable entry on the opposite side knocked out. Installation Instructions are printed on the sensor's packaging Check the wiring before switching on power. Select the required temperature measuring range on the sensor. provides a recalibration service for used sensors. Recalibration should be performed at 12-month intervals under normal conditions (that is within the comfort range for humidity and temperature and at air contamination levels that are not above average). Recalibration requires the purchase of a new sensor tip (part number AQF4150). The recalibration service includes the following: Delivery and invoicing of the new AQF4150 measuring tip, complete with calibration certificate. Delivery of a calibration certificate for the (old) measuring tip returned to Siemens Building Technologies, Inc. enabling the customer to assess the time of usage of the measuring. Page 5

Document Number 155-755 Q-Series Outdoor Air and Critical Environment Relative Humidity and Relative Humidity & Temperature Sensors Specifications Power Supply Operating voltage Frequency Power consumption 24 Vac + 20% or 13.5 to 35 Vdc 50/60 Hz at 24 Vac < 1 VA Humidity element Operating range 0 to 100% rh Measurement range 0 to 95% rh Accuracy at room temperature (73 F [20 C]) + 2% rh, 0 to 95% rh Time constant Approx. 20 s in moving air Output signal, linear (terminal U1) = 0 to 100% rh Max. + 1 ma Operating temperature -40 F to 158 F (-40 C to 70 C) Temperature effect < 0.1% per degree Celsius Sensing element Capacitive humidity sensing element Output signal (rh only units) 4 to 20 ma or, 0 to 100% linear, proportional Output signal (rh/t units) 4 to 20 ma or, 0 to 100% linear, proportional Polarity protection Temperature element (for combination rh/t units only) Operating temperature, jumper selectable Time constant @ 32 F to 122 F (0 C to 50 C) and 10 to 80% rh 32 F to 122 F (0 C to 50 C) or -31 F to 95 F (-35 C to 35 C), -40 F to 158 F (-40 C to 70 C) Approximately 20 s in moving air Accuracy @ 32 F to 122 F (0 C to 50 C) + 1.8 F (+ 1 C) @ -31 F to 95 F (-35 C to 35 C) + 1.4 F (+ 0.8 C) @ 32 F to 158 F (0 C to 70 C) + 1.8 F (+ 1 C) Output signal 4 to 20 ma or, 0 to 100% linear, proportional Calibration adjustments General Installation 18 AWG cable length shared in conduit with other sensor wiring. 750 ft (229 m) maximum Connections Screw terminals Dimensions Outdoor air probe 6" OD 3.3" L (15 mm 84 mm) Outdoor air housing 3.1" L 2.3" W 1.5" D (80 mm 60 mm 40 mm) Shield (mounted) 3.43" H 3.5" W 4.1" D (87 mm 89 mm 104 mm) Voltage requirement 13.5 to 35 Vdc Material type Polycarbonate plastic Protection class rating IP 65 (NEMA 4) Agency certification Conforms to EMC Directive 89/336/EEC UL Listing UL873 XAPX cul Listing Canadian Standard C22.2 No. 24-93 Conforms to Australian EMC Radio Communication Act 1992 Framework Radio Interference Emission AS/NZS 3548 Standard Page 6

Q-Series Outdoor Air and Critical Environment Technical Instructions Relative Humidity and Relative Humidity & Temperature Sensors Document Number 155-755 Wiring Terminals QFA3100 QFA3101 QFA3160/QFA3160D/ QFA4160/QFA4160D Figure 3. Wiring Terminals. QFA3171/QFA3171D/ QFA4171/QFA4171D QFA4160/QFA4160D Front View: Connector fitted, body removed Figure 4. Connectors. QFA4171/QFA4171D Front View: Connector fitted, body removed Dimensions Figure 5. QFA31 Series Sensors with AQF3100 Dimensions in Inches (Millimeters). Page 7

Document Number 155-755 Q-Series Outdoor Air and Critical Environment Relative Humidity and Relative Humidity & Temperature Sensors Dimensions, Continued Figure 6. QFA31 Series Dimensions in Inches (Millimeters). Figure 7. QFA41 Series Sensors Dimensions in Inches (Millimeters). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2013 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 USA + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com Document No. 155-755 Printed in the USA Page 8