New Generation KBF 240 series

Similar documents
Constant climate chambers

Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

KMF Environmental test chamber for constant climate

Constant climate chambers

Plant growth chambers

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with humidity

Constant climate chambers

Constant climate chambers

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Constant climate chambers

Model KBF 240 Constant climate chambers with large temperature / humidity range

BINDER Industrial. Product Catalog

BINDER Scientific Product Catalog

Vacuum drying oven for non-flammable solvents

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBWF 240 Growth chambers with light and humidity

VD 53 - Vacuum drying oven for non-flammable solvents

Model KBWF 720 Growth chambers with light and humidity

Vacuum drying VD VDL series

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Drying and heating chambers

CO₂ incubators. C CB series

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Safety vacuum drying oven for flammable solvents

Vacuum drying chambers. VD VDL series

Drying and heating chambers. Series ED FD FED FP M

BINDER Product catalog

CO₂ incubators. C CB series

Model C 170 CO 2 incubators with hot air sterilization

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Environmental Chambers

Translation of the original operating manual

Ultra low temperature freezers

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

ULTRA.GUARD ultra low temperature freezer

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

ICH750L. Climate Chamber. Product specification

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Translation of the original operating manual. Constant climate chambers with program control

Environmental Chambers

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Chromatographic Air circulated Refrigerator, two-door TC 603

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory thermostatic chambers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Laboratory Refrigerator/Deep Freezer TC 802

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

FITOCLIMA 600 & 1200 PHARMA

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Stability Testing according to GMP & FDA

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Key benefits. Why Condair CP3?

NEW GENERATION. Efficient use of valuable space INCUBATORS

FITOCLIMA 600 & 1200 STABILITY

Reproducible Climate...

FITOCLIMA 600 & 1200 STABILITY

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Protect your research

Humidity Controller Specification and Installation Instructions. Model HRO20

Model Model version Art. No. Model Model version Art. No. BD V 9010/ FD V 9010/ BD 56

ß-Aerosolmonitor FHT 59 C

Environmental Chambers Series: reach-in & benchtop capacities

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Translation of the original operating manual. Alternating climate chambers with program control

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Thermo Scientific Heraeus Heating and Drying Ovens

Long Term Storage Cabinet

ZL Laboratory freezers

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Manufacturer since

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

www

plus a wide temperature range

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Stability Testing GMP- and FDA-Compliant Reliable Solutions for the Pharmaceutical Industry

Transcription:

Constant climate chambers New Generation 240 series The constant climate chamber is the expert for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its large reserve capacity and wide range of climate area, it is designed to meet future challenges for many years to come. 1 2 3 VE Performance features and equipment: - Electronically controlled APT.line preheating chamber technology - Temperature range: -10 ºC to 100 ºC (14 ºF to 212 ºF) (without humidity) - Humidity range: 10 % - 90 % RH - MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments - User-friendly LCD screen - Easy-to-read menu guide - Integrated electronic chart recorder - Variety of options for the graphic display of process parameters - Real-time clock - Electronically controlled humidification and dehumidification system with capacitive humidity sensor - Suitable for stability tests in accordance with the ICH guideline Q1A - Heated door, inner glass door with sealing - Environmentally friendly refrigerant R 134a - Independent adjustable temperature safety device, Class 3.1 (DIN 12880) with optical and acoustic alarm - Access port with silicone plug, Ø 30 mm (1.2 inch), left side - Complete safety connection kit for water supply incl. water hose and drain (total length 6 m / 19.7 ft) - Ethernet interface for communication software APT-COM DataControlSystem - 2 stainless steel racks - BINDER test certificate

Technical specification 240 series 240 Exterior dimensions Width (mm/inch) 905/35.6 Height (incl. castors) (mm) 1458/57.4 Depth (mm/inch) 767/30.2 Plus door handle, I-triangle, connection (mm/inch) 52/2.0 Wall clearance rear (mm/inch) 100/3.9 Wall clearance side (mm/inch) 100/3.9 Steam space volume (l/qu.ft.) 338/11.9 Number of doors 1 Number of inner glas doors 1 Interior dimensions Width (mm/inch) 650/25.6 Height (mm/inch) 785/30.9 Depth (mm/inch) 470/18.5 Interior volume (l/qu.ft.) 240/8.5 Racks (number standard/max.) 2/9 Load per rack (kg/lbs.) 30/66 Permitted total load (kg/lbs.) 100/221 Weight (empty) (kg/lbs.) 185/408 Temperature data Temperature range without humidity ( C/ F) -10-100/14-212 with humidity ( C/ F) 10-90/50-194 Temperature variation without humidity at 25 C/77 F (± C) 0.2 at 40 C/104 F (± C) 0.3 Temperature variation with humidity 2) at 25 C(77 F)/60%RH (± C) 1.5 Temperature fluctuation with or w/o humidity at 25 C(77 F)/60%RH 0.1 to 1.0 Heating up time from 25 C (77 F) to 40 C (104 F) (min.) 15 Cooling down time from 40 C (104 F) to 5 C (41 F) (min.) 90 Recovery time after doors were open for 30 sec. at 25 C (77 F)/60 % RH (min.) 15 at 40 C (104 F)/75 % RH (min.) 18 Humidity fluctuation 2), 3) at 25 C/60% RH (± RF %) 2 Electrical data Housing protection acc. to EN 60529 IP 30 Nominal voltage (+ 5%/-10 %) 50/60 Hz (V) 200 240 Nominal power at 240 V (kw) 2.7 Energy consumption at 40 C(104 F)/75%RH 434 Temperature-humidity chart 240 Humidity % RF 240 03/08 Temperature C The light area indicates the control range of temperature and relative humidity. The hatched area indicates the control range of temperature and relative humidity without condensation. Heat Compensation 240 W 400 350 300 250 200 150 100 240 4/08 50 0-10 -5 0 5 10 15 20 25 30 35 40 Temp/ C You can operate your 240 with water from three different sources: 1 1 Tap water [municipal] with a max. hardness of 8.0 dh = 1.4285 mmol/l (the hardness can be established from the water analysis of your water supplier) 2 We recommend the BINDER Pure Aqua Service for longer maintenance intervals, regardless of water quality. 2 3 Demineralized or deionized water available at the customer s location. 3 VE 1) up to 98 % of the set value 2) value without illumin. 3) upon door opening > ± 1.5 RH %, recovery time approx. 20 min All technical data are specified for units with standard equipment at an ambient temperature of 25 C (77 F) and a voltage fluctuation of ± 10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times. BINDER GmbH PO BOX 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen Contact: Tel.: +49 (0) 7462/2005-0 Fax: +49 (0) 7462/2005-100 info@binder-world.com www.binder-world.com

Constant climate chambers series: Environmental simulation chambers for constant climatic conditions The series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its large reserve capacity and many optional features, it is designed to meet future challenges for many years to come. Performance features and equipment: - Electronically controlled APT.line preheating chamber technology - Temperature range: -10 ºC to 100 ºC (14 ºF to 212 ºF) (without humidity) - Humidity range: 10 % - 90 % RH - MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments - User-friendly LCD screen - Easy-to-read menu guide - Integrated electronic chart recorder - Variety of options for the graphic display of process parameters - Real-time clock - Electronically controlled humidification and dehumidification system with capacitive humidity sensor - Suitable for stability tests in accordance with the ICH guideline Q1A - Automatic defrosting device for long-term operation - Inner glass door - Environmentally friendly refrigerant R 134a - Collecting pan for condensate on the door - Independent adjustable temperature safety device, Class 3.1 (DIN 12880) with optical and acoustic alarm - Access port with silicone plug, Ø 30 mm (1.2 inch), right side - Complete safety connection kit for water supply incl. water hose and drain (total length 6 m / 19.7 ft) - RS 422 interface for communication software APT-COM DataControlSystem - 2 stainless steel racks - BINDER test certificate

Technical specification series 115 720 Exterior dimensions Width (mm/inch) 834 / 32.8 1234 / 48.6 Height (incl. feet/roller) (mm/inch) 1022 / 40.2 1816 / 71.5 Depth (mm/inch) 646 / 25.4 867 / 34.1 Plus door handle, I-triangle, connection (mm/inch) 100 / 3.9 100 / 3.9 Wall clearance rear (mm/inch) 100 / 3.9 100 / 3.9 Wall clearance side (mm/inch) 160 / 6.3 160 / 6.3 Steam space volume (l/cu.ft.) 158 / 5.6 855 / 30.2 Height of water connections (± 3 mm / 0.12 inch) 84 / 3.3 190 / 7.5 Number of doors 1 2 Number of inner glass doors 1 2 Interior dimensions Width (mm/inch) 600 / 23.6 1000 / 39.4 Height (mm/inch) 480 / 18.9 1168 / 46.0 Depth (mm/inch) 400 / 15.8 600 / 23.6 Interior volume (l/cu.ft.) 115 / 4.1 700 / 24.7 Racks (number standard/max.) 2 / 5 2 / 14 Load per rack (kg/lbs.) 20 / 44 45 / 99 Permitted total load (kg/lbs.) 50 / 110 120 / 265 Weight (empty) (kg/lbs.) 115 / 254 278 / 614 Temperature-humidity chart Humidity % RH Temperature data 10/06 Permissible ambient temperature range (ºC/ºF) 5) 18-32/64.4-89.6 18-32/64.4-89.6 without humidity (ºC/ºF) -10-100/14-212 -10-100/14-212 Temperature C with humidity (ºC/ºF) 10-90 / 50-194 10-90 / 50-194 Temperature variation without humidity The light area indicates the control at 10 ºC (50 ºF) (± ºC) 0.4/- 0.4/- range of temperature and relative at 37 ºC (98.6 ºF) (± ºC) 0.3/- 0.4/- humidity. The hatched area indicates Temperature variation with humidity 2) the control range of temperature and at 25ºC (77 ºF) (± ºC) 1 1 Temperature fluctuation from 5 ºC (9 ºF) above ambient relative humidity without condensation. temperature 2) (± ºC) 0.1 0.1 Temperature fluctuation when refrigeration system is in operation (± ºC) 0.5 0.5 Heating up time at 37 ºC (98.6 ºF) (Min.) 23 28 1) up to 98 % of the set value Cooling down time from room temp. 2) value without illumin. at 10 ºC (50 ºF) (Min.) 35 35 3) upon door opening or water Recovery time after doors were open for 30 sec. ex change in humidity cylinder: at 37 ºC (98.6 ºF) (Min.) 5 5 > ± 1.5 RH %, recovery time at 50 ºC (122 ºF) (Min.) 4 4 approx. 20 min Humidity fluctuation 3) (± RH%) 1.5 1.5 4) these energy consumption values can be used upon calculation of air Electrical data conditioning systems Housing protection acc. to EN 60529 IP 20 IP 20 5) Recommended ambient Nominal voltage (± 10 %) 50/60 Hz (V) 230 230 temperature 20 ºC Nominal power (W) 1300 2800 Energy consumption 4) at 37 ºC/40 ºC (W) 530 610 tap water with conductivity of approx. 200 500 μs/cm tolerance + 300 150 μs/cm, total hardness 4º 8 ºdH, content of chloride < 100mg/l (the hardness can be established from the water analysis of your water supplier) By introducing in a humidity source to the inner chamber the minimal humidity range is affected. A water tap (1 10 bar/14.5 145 psi) with normal tap water (conductivity of 200 500 μs/cm tolerance + 300 150 μs/cm, total hardness 4º 8 ºdH, content of chloride < 100mg/l) is necessary for the installation of the humidifying and dehumidifying system. Furthermore, a 40 mm (1.6 inch) water drain with descending gradient is required. All technical data are specified for units with standard equipment at an ambient temperature of 20 ºC (68 ºF) and a voltage fluctuation of ± 10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times. BINDER Inc. 3500 Sunrise Highway Suite D214 Great River NY 11739, USA Contact: Phone: +1 631 224 4340 Tollfree: +1 866 885 9794 Fax: +1 631 224 4354 us-sales@binder-world.com www.binder-world.us

Options/accessories 240 series BINDER Pure Aqua Service Our efficient, flexible water purification system delivers top water quality and extends the maintenance period. Special feature: Our system uses a disposable purification cartridge and also has a water quality indicator. 240 Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50, 100 mm diameter. APT-COM DataControlSystem Edition Software Software for control, programming and documentation. Permits networks of up to 40 units and/or controllers. Calibration certificate Measurement in the center at specified values. Additional measuring points or test values according to your specification. for photostability tests Photosensitive materials require extensive inspection and testing. In order to meet all of these requirements, we offer special light spectra and BINDER light measurement LQC. ICH/ LQC BINDER GmbH PO BOX 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen Contact: Tel.: +49 (0) 7462/2005-0 Fax: +49 (0) 7462/2005-100 info@binder-world.com www.binder-world.com

Options/accessories 240 series 115 240 720 Access port with silicone plug Rack, stainless steel Rack, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of rack securings (max. 70 kg / 154 lbs.) Independent adjustable temperature safety device, Class 3.3 (DIN 12880) Analog output, 4-20 ma for temperature and humidity with 6-pin DIN socket (Outputs are adjusted automatically as the controller is adjusted) Potential free alarm outputs for temperature and humidity, accessible via 6-pin DIN socket, with acoustic signal that can be switched off (maximum power 24 V AC/DC, 2.5 A) Interior lighting (W) 15 15 30 Lockable door Built-in 2-channel chart recorder, with digital display for the documentation of temperature and humidity Waterproof interior socket 230 V (maximum 500 W) Safety kit for water connection. Pre-mounted assembly of reflux prevention device and hose burst protection device BINDER Pure Aqua Service Exchange cartridge for BINDER Pure Aqua Service Vertically adjustable castors Temperature measurement according to DIN 12880 Calibration certificate for temperature and humidity Extension for calibration certificate (additional values) Fanfold chart paper, 1 set Disposable felt tips, 1 set Stable table on wheels with locking brake option not available Technical specifications subject to change BINDER Inc. 3500 Sunrise Highway Suite D214 Great River NY 11739, USA Contact: Phone: +1 631 224 4340 Tollfree: +1 866 885 9794 Fax: +1 631 224 4354 us-sales@binder-world.com www.binder-world.us